MAXFORCE ROACH KILLER GEL
002 07/25/00 MAXFORCE ROACH KILLER GEL
************************************************************************ SECTION I PRODUCT IDENTIFICATION ************************************************************************
PRODUCT NAME: MAXFORCE ROACH KILLER GEL
MSDS #: P13887V
DATE ISSUED: 03/97
SUPERCEDES: 05/96
ISSUED BY: 006516
SECTION I PRODUCT
TRADE NAME: Maxforce Professional insect control roach killer bait gel
EPA REGISTRATION NO.: 64248-5 Hydramethylnon Gel Maxforce Insect Control Systems
Manufacturer Maxforce Insect Control Systems 1221 Broadway Oakland, CA 94612
Emergency Telephone No. For Medical Emergencies, Call: Rocky Mountian Poison Center (800) 446-1014
For Transportation Emergencies Chemtrec (800) 424-9300
DESCRIPTION: Thick brown gel, sweet odor
************************************************************************ SECTION II HEALTH HAZARD DATA ************************************************************************
Maxforce Bait Gel is minimally irritating to the eyes and skin following prolonged direct contact. It is not acutely toxic upon oral or dermal exposure. Untoward effects resulting from over exposure are not anticipated to occur from use of the Bail Gel. Follow the precautions outlined below.
PRACTICAL TREATMENT: If swallowed, drink two glasses of water and induce vomiting by touching back of throat with finger. Do not induce vomiting or give anything by mouth to an unconscious person. Get medical attention.
No known health conditions are aggravated by exposure to this product.
************************************************************************ SECTION III HAZARDOUS INGREDIENTS ************************************************************************
INGREDIENT: Hydramethylnon CAS NO.: 67485-29-4 CONCENTRATION: 2.15% WORKER EXPOSURE LIMIT: 1.4 mg/m3 (TWA) *
None of the ingredients in this product are on the IARC, OSHA or NTP carcinogens lists.
* American Cyanamid PEL
************************************************************************ SECTION IV SPECIAL PROTECTION AND PRECAUTIONS ************************************************************************
HYGIENIC PRACTICES: Avoid contact with skin and clothing. Wash skin with soap and water if contact. Remove contaminated clothing and launder before re-wearing.
ENGINEERING CONTROLS: Use general ventilation to minimize exposure.
KEEP OUT OF THE REACH OF CHILDREN.
************************************************************************ SECTION V TRANSPORTATION AND REGULATORY DATA ************************************************************************
U.S. DOT HAZARD CLASS: Not restricted.
U.S. DOT PROPER SHIPPING NAME: Insecticide, non-toxic, solid - not restricted.
USDA: Authorized by USDA for use in Federally inspected meat, poultry, and shell egg grading plants. Approved F2: Residual pesticide.
EPA CERCLA/SARA TITLE III SUPERFUND AMENDMENT AND REAUTHORIZATION ACT: This product contains no CERCLA/SARA TITLE III materials.
************************************************************************ SECTION VI SPILL OR LEAK PROCEDURES ************************************************************************
Non-hazardous waste.
Place in a container for disposal.
Dispose in accordance with local, state and federal regulations.
************************************************************************ SECTION VII REACTIVITY DATA ************************************************************************
Stable under normal use and storage conditions. Product will stain porous surfaces.
************************************************************************ SECTION VIII FIRE AND EXPLOSION HAZARD DATA ************************************************************************
Not flammable or explosive.
************************************************************************ SECTION IX PHYSICAL DATA ************************************************************************
APPEARANCE: Thick yellow gel DENSITY: 8.75 - 9.58 lbs/gal pH: Not applicable
For emergency assistance involving chemicals, call CHEMTREC - (800) 424-9300 Univar USA 6100 Carillon Point, Kirkland WA 98033 - (425) 889-3400
Univar USA expressly disclaims all express or implied warranties of merchantability and fitness for a particular purpose, with respect to the product or information provided herein, and shall under no circumstances be liable for incidental or consequential damages.
All information appearing herien is based upon data obtained from the manufacturer and/or recognized technical sources. While the information is believed to be accurate, Univar USA makes no representations as to its accuracy or suffiency. Conditions of use are beyond Univar USA's control and therefore users are responsible to verify this data under their own operating conditions to determine whether the product is suitable for their particular purposes and they assume all risks of their use, handling, and disposal of the product, or from the publication or use of, or reliance upon, information contained herein. This information relates only to the product designated herein, and does not relate to its use in combination with any other material or in any other process.
We welcome your Feedback! By using this Web site, you agree to be bound by our usage policies to learn more see Copyright© 1998, Univar USA