SECTION 07610 METAL ROOFING

Display hidden notes to specifier. (Don't know how? Click Here)

Copyright 2016 - 2017 ARCAT, Inc. - All rights reserved

PART 1 GENERAL

1.1 SECTION INCLUDES

1.A. Concealed fastener metal roofing, trim and accessories: 1.A.1. Gulf Lok Metal Roofing System. 1.A.2. Gulf Lok HR Metal Roofing System. 1.A.3. Gulf Seam Metal Roofing System. 1.A.4. Gulf Snap Metal Roofing System. 1.A.5. Versaloc Metal Roofing System. 1.A.6. Megaloc Metal Roofing System.

1.B. Exposed fastener metal roofing, trim and accessories: 1.B.1. Gulf Rib Metal Roofing System. 1.B.2. 5V Metal Roofing System. 1.B.3. PBR Metal Roofing System. 1.B.4. Gulf Wave Metal Roofing.

1.2 RELATED SECTIONS

2.A. Section 05120 - Structural Steel: Primary framing system.

2.B. Section 05400 - Cold Formed Framing: Secondary framing system.

2.C. Section 061500 - Wood Decking: Substrate attachment.

1.3 SUBMITTALS

3.A. Submit under provisions of Section 01300. 07610-1 3.B. Product Data: Manufacturer's data sheets on each product to be used, including: 3.B.1. Storage and handling requirements and recommendations. 3.B.2. Installation methods.

3.C. Shop Drawings: Include materials, anchors, details of construction, including relationship with adjacent construction.

3.D. Selection Samples: For each finish product specified, two color charts representing manufacturer's full range of available colors and patterns.

3.E. Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square representing actual product, color, and patterns.

1.4 QUALITY ASSURANCE

4.A. Manufacturer Qualifications: Minimum 5 year experience manufacturing similar products.

4.B. Installer Qualifications: Minimum 2 year experience installing similar products.

4.C. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship. 4.C.1. Finish areas designated by Architect. 4.C.2. Do not proceed with remaining work until workmanship is approved by Architect. 4.C.3. Refinish mock-up area as required to produce acceptable work.

1.5 PRE-INSTALLATION MEETINGS

5.A. Convene minimum two weeks prior to starting work of this section.

1.6 DELIVERY, STORAGE, AND HANDLING

6.A. Deliver and store products in manufacturer's unopened packaging bearing the brand name and manufacturer's identification until ready for installation.

6.B. Handling: Handle materials to avoid damage.

1.7 PROJECT CONDITIONS

7.A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.

1.8 SEQUENCING 07610-2 8.A. Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.

PART 2 PRODUCTS

2.1 MANUFACTURERS

1.A. Acceptable Manufacturer: Gulf Coast Supply & Manufacturing, which is located at: 14429 SW 2nd Place, Suite G30; Newberry, FL 32669 ; Toll Free Tel: (888) 393-0335; Tel: (352) 498- 0778; Fax: (352) 498-7852; Email: request info ([email protected]); Web: http://www.gulfcoastsupply.com

1.B. Substitutions: Not permitted.

1.C. Requests for substitutions will be considered in accordance with provisions of Section 01600.

2.2 GULF LOK METAL ROOFING SYSTEM

2.A. Product: Gulf Lok as manufactured by GulfCoast Supply & Manufacturing. 2.A.1. Design: Concealed fastener snap lock seam with nailing flange. Application over continuous roof deck. 2.A.2. Performance: 2.A.2.a. HVHZ/Miami-Dade Approval 14-0520.03. 2.A.2.b. FL Product Approval No. 11651. 2.A.2.c. Miami Dade NOA 14-0520.03 (Miami Dade Product Approval). 2.A.2.c.1) Construction: Minimum 26ga. (0.45 mm) GulfLok, maximum 16 inches (406 mm) Wide Snap Lock Metal Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 2.A.2.d. FL#11651.2 R2 (NON HVHZ Metal Roof Florida Product Approval). 2.A.2.d.1) Construction: minimum nominal 0.032 inch (0.8 mm) GulfLok, maximum 16 inches (406 mm) Wide Snap Lock Aluminum Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 2.A.2.e. FL#11651.9 R2 (NON HVHZ Metal Roof Florida Product Approval). 2.A.2.e.1) Construction: minimum 24ga. (0.61 mm) GulfLok, maximum 16 inches (406 mm) Wide Snap Lock Metal Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 2.A.2.f. FL#11651.15 R2 (HVHZ Metal Roof Florida Product Approval). 2.A.2.f.1) Construction: minimum 26ga. (0.45 mm) GulfLok, maximum 16 inches (406 mm) Wide Snap Lock Metal Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 2.A.2.g. FL#11651.16 R2 (NON HVHZ Metal Roof Florida Product Approval). 2.A.2.g.1) 07610-3 Construction: Minimum 26ga. GulfLok, maximum 16 inches (406 mm) Wide Snap Lock Metal Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 2.A.3. Coverage: 12 inches (305 mm) Net Coverage. 2.A.4. Coverage: 16 inches (406 mm) Net Coverage. 2.A.5. Seam Height: 1 inch (25 mm). 2.A.6. Profile Configuration: Flat (no mini ribs or striations between major ribs). 2.A.7. Profile Configuration: With double mini ribs between major ribs. 2.A.8. Profile Configuration: With striations. 2.A.9. Steel: 24 Gauge (0.61 mm). 2.A.10. Steel: 26 Gauge (0.45 mm). 2.A.11. Aluminum: nominal 0.032 inch (0.8 mm). 2.A.12. Aluminum: nominal 0.040 Inch (1.0 mm). 2.A.13. Minimum Slope: 3:12 (lower with evaluation from manufacturer and written approval) 2.A.14. Deck Substrate: 15/32 inch (11.6 mm) CDX (minimum). 2.A.15. Concealed Anchoring Clip: Coastal Clip as engineered and manufactured by Gulf coast Supply and Manufacturing. UL-90 performance. 2.A.16. Finish: ______. 2.A.17. Substrate/Warranty: 2.A.17.a. AZ-50 Gulfalume / 35/30 Year Premium Paint Finish. 2.A.17.b. AZ-50 Gulfalume / 40/30 Year Standard Paint Finish Warranty. 2.A.17.c. AZ-55 Gulfalume / 25 Year Unpainted Mill Finish Warranty. 2.A.17.d. 25/20 Year OceanGuard Salt Water Warranty.

2.3 GULF LOKHR METAL ROOFING SYSTEM

3.A. Product: Gulf LokHR as manufactured by GulfCoast Supply & Manufacturing. 3.A.1. Design: Concealed fastener snap lock seam with nailing flange. Application over continuous roof deck. 3.A.2. Performance: 3.A.2.a. FL Product Approval No. 11651. 3.A.2.b. FL Product Approval No. 18473.1 3.A.2.b.1) Construction: Minimum 24ga. (0.6 mm) GulfLokHR, maximum 15 inches (381 mm) Wide Snap Lock Metal Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 3.A.3. 07610-4 Coverage: 15 inches (381 mm) Net Coverage. 3.A.4. Seam Height: 1.5 inch (38 mm). 3.A.5. Profile Configuration: Flat (no mini ribs or striations between major ribs. 3.A.6. Profile Configuration: With double mini ribs between major ribs. 3.A.7. Profile Configuration: With striations. 3.A.8. Steel: 24 Gauge (0.6 mm). 3.A.9. Minimum Slope: 3:12 (lower with evaluation from manufacturer and written approval) 3.A.10. Deck Substrate: 15/32 inch (11.6 mm) CDX (minimum). 3.A.11. Finish: ______. 3.A.12. Substrate/Warranty: 3.A.12.a. AZ-50 Gulfalume/35/30 Year Premium Paint Finish. 3.A.12.b. AZ-55 Gulfalume/25 Year Unpainted Mill Finish Warranty.

2.4 GULF SEAM METAL ROOFING SYSTEM

4.A. Product: Gulf Seam as manufactured by GulfCoast Supply & Manufacturing 4.A.1. Design: Concealed fastener clip lock seam with clip attachment. Application over continuous deck or deck + purlin framing. 4.A.2. Performance: 4.A.2.a. FL Product Approval No. 11651. 4.A.2.b. FL Product Approval No. 16646. 4.A.2.c. FL#11651.10 R2 (NON HVHZ Metal Roof Florida Product Approval). 4.A.2.c.1) Construction: minimum 24ga. (0.61 mm) GulfSeam maximum 16 inch (406 mm) Wide Metal Roof Panels installed over 1x4 Wood Purlins over minimum 15/32 inch (11.6 mm) Plywood. 4.A.2.d. FL#11651.11 R2 (NON HVHZ Metal Roof Florida Product Approval). 4.A.2.d.1) Construction: minimum 24ga. (0.61 mm) GulfSeam maximum 18 inch (457 mm) Wide Metal Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 4.A.2.e. FL#16646.5 R1 (NON HVHZ Metal Roof Florida Product Approval). 4.A.2.e.1) Construction: minimum 24ga. (0.61 mm) GulfSeam maximum 18 inch (457 mm) Wide Metal Roof Panels installed over 1x4 Wood Purlins over minimum 15/32 inch (11.6 mm) Plywood. 4.A.2.f. FL#16646.2 R1 (NON HVHZ Metal Roof Florida Product Approval). 4.A.2.f.1) Construction: minimum .032" Aluminum (0.81 mm) GulfSeam maximum 18 inch (457 mm) Wide Metal Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 07610-5 4.A.2.g. FL#16646.3 R1 (NON HVHZ Metal Roof Florida Product Approval). 4.A.2.g.1) Construction: minimum .032" Aluminum (0.81 mm) GulfSeam maximum 16 inch (406 mm) Wide Metal Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 4.A.3. Coverage: 12 inches (305 mm) Net Coverage. 4.A.4. Coverage: 14 inches (356 mm) Net Coverage. 4.A.5. Coverage: 16 inches (406 mm) Net Coverage. 4.A.6. Coverage: 18 inches (457 mm) Net Coverage. 4.A.7. Seam Height: 1-3/4 inches (44.5 mm). 4.A.8. Profile Configuration: Flat (no mini ribs or striations between major ribs. 4.A.9. Profile Configuration: With double mini ribs between major ribs. 4.A.10. Profile Configuration: With striations. 4.A.11. Steel: 24 Gauge (0.61 mm). 4.A.12. Aluminum: nominal 0.032 inch (0.8 mm). 4.A.13. Aluminum: nominal 0.040 Inch (1.0 mm). 4.A.14. Minimum Slope: 3:12. (lower with evaluation from manufacturer and written approval) 4.A.15. Deck Structure: minimum 15/32 inch (11.6 mm) CDX (minimum). 4.A.16. Deck Structure: minimum 15/32 inch (11.6 mm) CDX (minimum) decking with 1x4 wood purlins installed over. 4.A.17. Concealed Anchoring Clip: Clip as engineered by Gulfcoast Supply and Manufacturing. UL-90 performance. 4.A.18. Finish: ______. 4.A.19. Substrate/Warranty: 4.A.19.a. AZ-50 Gulfalume / 35/30 Year Premium Paint Finish. 4.A.19.b. AZ-55 Gulfalume / 25 Year Unpainted Mill Finish Warranty. 4.A.19.c. 25/20 Year OceanGuard Salt Water Warranty.

2.5 GULF SNAP METAL ROOF PANEL

5.A. Product: Gulf Snap as manufactured by GulfCoast Supply & Manufacturing 5.A.1. Design: Concealed snap lock seam. Application over continuous deck. 5.A.2. Performance: 5.A.2.a. FL Product Approval No. 11651. 5.A.2.b. FL#11651.3 R2 (HVHZ). 07610-6 5.A.2.b.1) Construction: minimum 24ga. (0.61 mm) GulfSnap 1 inch (25 mm) Rib Hgt. X maximum 17 inches (432 mm) Wide Standing Seam Metal Roof Panel installed over minimum 15/32 inch (11.6 mm) Plywood. 5.A.2.c. FL#11651.6 R2 (HVHZ). 5.A.2.c.1) Construction: minimum 24ga. (0.61 mm) GulfSnap 1.5 inches (38 mm) Rib Hgt. X maximum 16 inches (407 mm) Wide Standing Seam Metal Roof Panel installed over minimum 15/32 inch (11.6 mm) Plywood 5.A.3. Coverage: 12 inches (305 mm) Net Coverage. 5.A.4. Coverage: 16 inches (407 mm) Net Coverage. 5.A.5. Coverage: 17 inches (432 mm) Net Coverage. 5.A.6. Seam Height: 1 inches (25 mm). 5.A.7. Seam Height: 1-1/2 inches (38 mm). 5.A.8. Profile Configuration: Flat (no mini ribs or striations between major ribs. 5.A.9. Profile Configuration: With double mini ribs between major ribs. 5.A.10. Profile Configuration: With striations. 5.A.11. Steel: 24 Gauge (0.61 mm). 5.A.12. Minimum Slope: 3:12. (lower with evaluation from manufacturer and written approval) 5.A.13. Deck Structure: 15/32 inch (11.6 mm) CDX (minimum). 5.A.14. Concealed Anchoring Clip: Clip as engineered by Gulfcoast Supply and Manufacturing. UL-90 performance. 5.A.15. Finish: ______. 5.A.16. Substrate/Warranty: 5.A.16.a. AZ-50 Gulfalume / 35/30 Year Premium Paint Finish. 5.A.16.b. AZ-55 Gulfalume / 25 Year Unpainted Mill Finish Warranty.

2.6 VERSALOC METAL ROOFING SYSTEM

6.A. Product: Versaloc as manufactured by GulfCoast Supply & Manufacturing. 6.A.1. Design: Concealed clip mechanical lock seam. Application over continuous wood or steel deck. 6.A.2. Performance: 6.A.2.a. HVHZ/Miami-Dade Approval (w/1-1/2 inches (38 mm) seam hgt.) NOA #14-0520 6.A.2.b. FL Product Approval No. 11651. 6.A.2.c. Miami Dade NOA # 14-0520.05 (Miami Dade Product Approval). 6.A.2.c.1) Construction: minimum 24ga. Versaloc with 1.5 inches (38mm) seam hgt x 07610-7 20 inches (508 mm) maximum width mechanically seamed metal roofing panel installed over minimum 15/32 (11.6 mm) inch thick plywood 6.A.2.d. Miami Dade NOA # 14-0520.06 (Miami Dade Product Approval). 6.A.2.d.1) Construction: minimum .032 inch Versaloc with 1.5 inches (38mm) seam hgt x 20 inches (508 mm) maximum width mechanically seamed metal roofing panel installed over minimum 15/32 (11.6 mm) inch thick plywood 6.A.2.e. Miami Dade NOA # 14-0520.07 (Miami Dade Product Approval). 6.A.2.e.1) Construction minimum 24ga. Stainless Steel Versaloc with 1.5 inches (38mm) seam hgt x 20 inches (508 mm) maximum width mechanically seamed metal roofing panel installed over minimum 15/32 (11.6 mm) inch thick plywood 6.A.2.f. Miami Dade NOA # 14-0520.08 (Miami Dade Product Approval). 6.A.2.f.1) Construction minimum 16 ounce Copper Versaloc with 1.5 inches (38mm) seam hgt x 16 inches (406 mm) maximum width mechanically seamed metal roofing panel installed over minimum 15/32 (11.6 mm) inch thick plywood 6.A.2.g. FL#11651.4 R2 (HVHZ). 6.A.2.g.1) Construction: minimum 24ga. Versaloc SR 1 inch ( 25.4 mm) Rib Hgt. X 16.5 inches (419 mm) Wide Mechanical Seam Metal Roofing Panel installed over minimum 15/32 (11.6 mm) inch thick plywood. 6.A.2.h. FL#11651.5 R2 (HVHZ). 6.A.2.h.1) Construction: minimum .032 inch Aluminum Versaloc SR 1 inch ( 25.4 mm) Rib Hgt. X 16 inches (406 mm) Wide Mechanical Seam Metal Roofing Panel installed over minimum 15/32 (11.6 mm) inch thick plywood. 6.A.2.i. FL#11651.7 R2 (HVHZ). 6.A.2.i.1) Construction: minimum 24ga. Versaloc 1.5 inch (38 mm) Rib Hgt. X 16 inches (406 mm) Wide Mechanical Seam Metal Roofing Panel installed over minimum 15/32 (11.6 mm) inch thick plywood. 6.A.3. Coverage: 12 inches (305 mm) Net Coverage. 6.A.4. Coverage: 14 inches (356 mm) Net Coverage. 6.A.5. Coverage: 16 inches (406 mm) Net Coverage. 6.A.6. Coverage: 18 inches (457 mm) Net Coverage. 6.A.7. Coverage: 20 inches (508 mm) Net Coverage. 6.A.8. Seam Height: 1 inches (25 mm). 6.A.9. Seam Height: 1-1/2 inches (38 mm). 6.A.10. Profile Configuration: Flat (no mini ribs or striations between major ribs. 6.A.11. Profile Configuration: With double mini ribs between major ribs. 6.A.12. Profile Configuration: With striations. 6.A.13. Steel: 24 Gauge (0.61 mm). 07610-8 6.A.14. Stainless Steel: 24 Gauge (0.62 mm). 6.A.15. Copper: 16 ounce. 6.A.16. Aluminum: 0.032 inch (0.8 mm). 6.A.17. Aluminum: 0.040 Inch (1.0 mm). 6.A.18. Minimum Slope: 1/4:12. 6.A.19. Deck Structure: 15/32 inch (11.6 mm) CDX (minimum). 6.A.20. Concealed Anchoring Clip: Clip as engineered by Gulfcoast Supply and Manufacturing. UL-90 performance. 6.A.21. Finish: ______. 6.A.22. Substrate/Warranty: 6.A.22.a. AZ-50 Gulfalume / 35/30 Year Premium Paint Finish. 6.A.22.b. AZ-50 Gulfalume / 40/30 Year Standard Paint Finish Warranty. 6.A.22.c. AZ-55 Gulfalume / 25 Year Unpainted Mill Finish Warranty. 6.A.22.d. 25 Year OceanGuard Salt Water Warranty. 6.A.22.e. 20 Year Water Tightness Warranty.

2.7 MEGALOC METAL ROOFING SYSTEM

7.A. Product: Megaloc as manufactured by GulfCoast Supply & Manufacturing. 7.A.1. Design: Concealed clip mechanical lock seam. Application over continuous wood or steel deck or Steel Purlins 7.A.2. Performance: 7.A.2.a. Miami-Dade Approval NOA #14-0520 7.A.2.b. FL Product Approval No. 11650 & 11651 7.A.2.c. Miami Dade NOA # 14-0520.09 (Miami Dade Product Approval).. 7.A.2.c.1) Construction: minimum 24ga. Megaloc with 2 inches (51mm) seam hgt x maximum 22.5 inches (508 mm) maximum width mechanically seamed metal roofing panel installed over minimum 22 gauge steel decking 7.A.2.d. Miami Dade NOA # 14-0520.10 (Miami Dade Product Approval). 7.A.2.d.1) Construction: minimum .032 inch aluminum Megaloc with 2 inches (51mm) seam hgt x maximum 22.5 inches (508 mm) maximum width mechanically seamed metal roofing panel installed over minimum 22 gauge steel decking 7.A.2.e. FL#11650.1 R2 (non-HVHZ). 7.A.2.e.1) Construction: minimum 24ga. Megaloc 2 inch (51 mm) Rib Hgt. X maximum 18 inches (457 mm) Wide Mechanical Seam Metal Roofing Panel installed over minimum 16ga. Steel Purlins. 07610-9 7.A.2.f. FL#11651.8 R2 (non-HVHZ). 7.A.2.f.1) Construction: minimum 24ga. Megaloc 2 inch (51 mm) Rib Hgt. X maximum 18 inches (457 mm) Wide Mechanical Seam Metal Roofing Panel installed over minimum 15/32 (11.6 mm) inch thick plywood. 7.A.3. Coverage: 12 inches (305 mm) Net Coverage. 7.A.4. Coverage: 14 inches (356 mm) Net Coverage. 7.A.5. Coverage: 16 inches (406 mm) Net Coverage. 7.A.6. Coverage: 18 inches (457 mm) Net Coverage. 7.A.7. Coverage: 20 inches (508 mm) Net Coverage. 7.A.8. Coverage: 22.5 inches (572 mm) Net Coverage. 7.A.9. Seam Height: 2 inches (51 mm). 7.A.10. Profile Configuration: Flat (no mini ribs or striations between major ribs. 7.A.11. Profile Configuration: With double mini ribs between major ribs. 7.A.12. Profile Configuration: With striations. 7.A.13. Steel: 24 Gauge (0.61 mm). 7.A.14. Aluminum: 0.032 inch (0.8 mm). 7.A.15. Aluminum: 0.040 Inch (1.0 mm). 7.A.16. Minimum Slope: 1/4:12. 7.A.17. Deck Structure: 15/32 inch (11.6 mm) CDX (minimum). 7.A.17.a. Deck Structure: minimum 22 gauge steel decking. 7.A.18. Open Framing Structure: minimum 16ga purlins. 7.A.19. Concealed Anchoring Clip: Clip as engineered by Gulfcoast Supply and Manufacturing. UL-90 performance. 7.A.20. Finish: ______. 7.A.21. Substrate/Warranty: 7.A.21.a. AZ-50 Gulfalume / 35/30 Year Premium Paint Finish. 7.A.21.b. AZ-50 Gulfalume / 40/30 Year Standard Paint Finish Warranty. 7.A.21.c. AZ-55 Gulfalume / 25 Year Unpainted Mill Finish Warranty. 7.A.21.d. 25 Year OceanGuard Salt Water Warranty. 7.A.21.e. 20 Year Water Tightness Warranty.

2.8 GULF RIB METAL ROOFING SYSTEM

8.A. 07610-10 Product: GulfRib as manufactured by GulfCoast Supply & Manufacturing 8.A.1. Design: Exposed fastener lap seam panel. Application over continuous deck structure. 8.A.2. Performance: 8.A.2.a. Miami-Dade Approval No. 14-0520. 8.A.2.b. FL Product Approval No. 11651 & 16646. 8.A.2.c. Miami Dade NOA # 14-0520.01 (Miami Dade Product Approval). 8.A.2.c.1) Construction: minimum 26 Ga. (0.45 mm) GulfRib over minimum 15/32 inch (11.6 mm) Plywood 8.A.2.d. Miami Dade NOA # 14-0520.04. 8.A.2.d.1) Construction: minimum 26 Ga. (0.45 mm) Gulf Rib over minimum 1x4 Wood Purlins over minimum 15/32 inch (11.6 mm) Plywood. 8.A.2.e. FL#11651.21 R2 (NON HVHZ Metal Roof Florida Product Approval). 8.A.2.e.1) Construction: minimum 26 Ga. (0.45 mm) GulfRib over minimum 1x4 Wood Purlins over minimum 15/32 inch (11.6 mm) Plywood. 8.A.2.f. FL#11651.22 R2 (NON HVHZ Metal Roof Florida Product Approval). 8.A.2.f.1) Construction: minimum 26 Ga. (0.45 mm) GulfRib over minimum 15/32 inch (11.6 mm) Plywood. 8.A.2.g. FL#11651.23 R2 (HVHZ Metal Roof Florida Product Approval). 8.A.2.g.1) Construction: minimum 26 Ga. (0.45 mm) GulfRib over minimum 15/32 inch (11.6 mm) Plywood. 8.A.2.h. FL#11651.24 R2 (HVHZ Metal Roof Florida Product Approval). 8.A.2.h.1) Construction: minimum 26 Ga. (0.45 mm) GulfRib over minimum 1x4 Wood Purlins over minimum 15/32 inch (11.6 mm) Plywood. 8.A.2.i. FL#11651.25 R2 (NON HVHZ Metal Roof Florida Product Approval). 8.A.2.i.1) Construction: 29 Ga. (0.34 mm) GulfRib over 1x4 Wood Purlins over 15/32 inch (11.6 mm) Plywood. 8.A.2.j. FL#11651.26 R2 (NON HVHZ Metal Roof Florida Product Approval). 8.A.2.j.1) Construction: minimum 29 Ga. (0.34 mm) GulfRib over minimum 15/32 inch (11.6 mm) Plywood. 8.A.2.k. FL#11651.27 R2 (NON HVHZ Metal Roof Florida Product Approval). 8.A.2.k.1) Construction: minimum 29 Ga. (0.34 mm) GulfRib over minimum 1x4 Wood Purlins over minimum 7/16 inches (11 mm) O.S.B. 8.A.2.l. FL#11651.28 R2 (NON HVHZ Metal Roof Florida Product Approval). 8.A.2.l.1) Construction: minimum 29 Ga. (0.34 mm) GulfRib over minimum 7/16 inches (11 mm) O.S.B. 8.A.2.m. FL#16646.1 R1 (NON HVHZ Metal Roofing Florida Product Approval. 8.A.2.m.1) 07610-11 Construction: minimum 29 Ga. (.34 mm) GulfRib over minimum 15/32 inch (11.6 mm) Plywood. Fasteners through high points of ribs. 8.A.3. Panel Coverage: 36 inches (914 mm) Net Coverage. 8.A.4. Profile Height: 3/4 inch (19 mm) trapezoidal shaped ribs 9 inches (229 mm) apart with two intermediate striations. 8.A.5. Steel: 24 Gauge (0.61 mm). 8.A.6. Steel: 26 Gauge (0.45 mm). 8.A.7. Steel: 29 Gauge (0.34 mm). 8.A.8. Minimum Slope: 3:12. (lower with evaluation from manufacturer and written approval) 8.A.9. Deck Structure: minimum 15/32 inch (11.6 mm) CDX (minimum) 8.A.10. Deck Structure: minimum 15/32 inch (11.6 mm) CDX plywood with minimum #2 1x4 Yellow Pine purlins 8.A.11. Deck Structure: minimum 7/16 inch (11 mm) OSB minimum with minimum #2 1x4 Yellow Pine purlins 8.A.12. Deck Structure: minimum 7/16 inch (11 mm) O.S.B. 8.A.13. Finish: ______. 8.A.14. Substrate/Warranty: 8.A.14.a. AZ-50 Gulfalume / 35/30 Year Premium Paint Finish. 8.A.14.b. AZ-50 Gulfalume / 40/30 Year Standard Paint Finish Warranty. 8.A.14.c. AZ-55 Gulfalume / 25 Year Unpainted Mill Finish Warranty.

2.9 5V METAL ROOFING SYSTEM

9.A. Product: 5V Crimp as manufactured by GulfCoast Supply & Manufacturing 9.A.1. Design: Exposed fastener lap seam panel. Application over continuous deck structure. 9.A.2. Performance: 9.A.2.a. Miami-Dade Approval No. 14-0520. 9.A.2.b. FL Product Approval No. 11651. 9.A.2.c. Miami Dade NOA # 14-0520.02 9.A.2.c.1) Construction: minimum 26ga (0.45 mm) 5V Crimp 24 inches (610 mm) Wide Metal Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood 9.A.2.d. FL#11651.1 R2 (NON HVHZ Metal Roof Florida Product Approval). 9.A.2.d.1) Construction: minimum nominal 0.032 inch (0.8 mm) 5V Crimp 24 inches (610 mm) Wide Aluminum Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 9.A.2.e. FL#11651.12 R2 (HVHZ Metal Roof Florida Product Approval). 07610-12 9.A.2.e.1) Construction: minimum 26ga. (0.45 mm) 5V Crimp 24 inches (610 mm) Wide Metal Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 9.A.2.f. FL#11651.13 R2 (NON HVHZ Metal Roof Florida Product Approval). 9.A.2.f.1) Construction: minimum 26ga. (0.45 mm) 5V Crimp 24 inches (610 mm) Wide Metal Roof Panels installed over minimum 15/32 inch (11.6 mm) Plywood. 9.A.2.g. FL#11651.14 R2 (NON HVHZ Metal Roof Florida Product Approval) 9.A.2.g.1) Construction: minimum 26ga. (0.45 mm) 5V Crimp 24 inches (610 mm) Wide Metal Roof Panels installed over minimum 1x4 Wood Purlins over minimum 15/32 inch (11.6 mm) Plywood. 9.A.3. Panel Coverage: 24 inches (610 mm) Net Coverage. 9.A.4. Profile Height: 7/16 inch (11 mm) alternating single and double ribs 12 inches (305 mm) apart. 9.A.5. Profile Configuration: Flat (no mini ribs or striations between major ribs. 9.A.6. Profile Configuration: With single mini ribs between major ribs. 9.A.7. Profile Configuration: With striations. 9.A.8. Steel: 26 Gauge (0.45 mm). 9.A.9. Steel: 29 Gauge (0.34 mm). 9.A.10. Aluminum: 0.032 inch (0.8 mm). 9.A.11. Aluminum: 0.040 Inch (1.0 mm). 9.A.12. Minimum Slope: 3:12 (lower with evaluation from manufacturer and written approval). 9.A.13. Deck Structure: 15/32 inch (11.6 mm) CDX (minimum) or #2 1x4 Yellow Pine. 9.A.14. Finish: ______. 9.A.15. Substrate/Warranty: 9.A.15.a. AZ-50 Gulfalume / 35/30 Year Premium Paint Finish. 9.A.15.b. AZ-50 Gulfalume / 40/30 Year Standard Paint Finish Warranty. 9.A.15.c. AZ-55 Gulfalume / 25 Year Unpainted Mill Finish Warranty. 9.A.15.d. 25 Year OceanGuard Salt Water Warranty.

2.10 PBR METAL ROOFING SYSTEM

10.A. Product: GulfPBR as manufactured by GulfCoast Supply & Manufacturing 10.A.1. Design: Exposed fastener lap seam panel. Application over continuous deck structure. 10.A.2. Performance: 10.A.2.a. 07610-13 FL Product Approval No. 11651. 10.A.2.b. FL Structural Product Approval No. 11650. 10.A.2.c. FL#11650.2 R1 (HVHZ Florida Product Approval) 10.A.2.c.1) Construction: minimum 24ga. (0.61 mm) GulfPBR 36 inches (914 mm) Wide PBR Metal Roofing Panel installed over minimum 16ga. Open Framing 10.A.2.d. FL#11650.3 R1 (NON-HVHZ Florida Product Approval) 10.A.2.d.1) Construction: minimum 26 Ga. (0.45 mm) GulfPBR 36 inches (914 mm) Wide PBR Metal Roofing Panel installed over minimum 16ga. Open Framing 10.A.2.e. FL#11651.17 R1 (NON-HVHZ Florida Product Approval) 10.A.2.e.1) Construction: minimum 26 Ga. (0.45 mm) GulfPBR 36 inches (914 mm) Wide PBR Metal Roofing Panel installed over minimum 15/32 inch (11.6 mm) Plywood 10.A.2.f. FL#11651.18 R1 (HVHZ Florida Product Approval) 10.A.2.f.1) Construction: minimum 26 Ga. (0.45 mm)GulfPBR 36 inches (914 mm) Wide PBR Metal Roofing Panel installed over minimum 1x4 Wood Purlins over minimum 15/32 inch (11.6 mm) Plywood 10.A.2.g. FL#11651.19 R1 (HVHZ Florida Product Approval) 10.A.2.g.1) Construction: minimum 26 Ga. (0.45 mm) GulfPBR 36" Wide PBR Metal Roofing Panel installed over minimum 15/32 inch (11.6 mm) Plywood 10.A.2.h. FL#11651.20 R1 (NON-HVHZ Florida Product Approval) 10.A.2.h.1) Construction: minimum 26 Ga. (0.45 mm)GulfPBR 36" Wide PBR Metal Roofing Panel installed over minimum 1x4 Wood Purlins over minimum 15/32 inch (11.6 mm) Plywood 10.A.3. Panel Coverage: 36 inches (914 mm) Net Coverage. 10.A.4. Profile Height: 1-1/4 inches (32 mm) trapezoidal shaped ribs 12 inches (305 mm) apart with two intermediate striations. 10.A.5. Steel: 24 Gauge (0.61 mm). 10.A.6. Steel: 26 Gauge (0.45 mm). 10.A.7. Minimum Slope: 1/2:12. 10.A.8. Deck Structure: minimum 15/32 inch (11.6 mm) CDX, minimum 1x4 purlins over minimum 15/32 inch (11.6 mm) or minimum 16ga. Open Framing. 10.A.9. Finish: ______. 10.A.10. Substrate/Warranty: 10.A.10.a. AZ-50 Gulfalume / 35/30 Year Premium Paint Finish. 10.A.10.b. AZ-50 Gulfalume / 40/30 Year Standard Paint Finish Warranty. 10.A.10.c. AZ-55 Gulfalume / 25 Year Unpainted Mill Finish Warranty.

07610-14 2.11 GULFWAVE METAL ROOFING

11.A. Product: GulfWave as manufactured by GulfCoast Supply & Manufacturing 11.A.1. Design: Exposed fastener lap seam panel. Application over continuous deck structure. 11.A.2. Performance: 11.A.2.a. FL Product Approval No. Pending. 11.A.3. Panel Coverage: 32 inches (813 mm) Net Coverage. 11.A.4. Profile Height: 3/4 inch (19 mm) continuous wave corrugations. 11.A.5. Steel: 24 Gauge (0.61 mm). 11.A.6. Steel: 26 Gauge (0.45 mm). 11.A.7. Steel: 29 Gauge (0.34 mm). 11.A.8. Minimum Slope: 3:12 (lower with evaluation from manufacturer and written approval). 11.A.9. Deck Structure: 15/32 inch (11.6 mm) CDX (minimum). 11.A.10. Finish: ______. 11.A.11. Substrate/Warranty: 11.A.11.a. AZ-50 Gulfalume / 35/30 Year Premium Paint Finish. 11.A.11.b. AZ-50 Gulfalume / 40/30 Year Standard Paint Finish Warranty. 11.A.11.c. AZ-55 Gulfalume / 25 Year Unpainted Mill Finish Warranty.

2.12 METAL TRIM

12.A. Ridge Caps: Provide manufacturer's standard units based on roof configuration and pitch and as indicated on the Drawings.

12.B. Eave Drip: Provide manufacturer's standard units based on roof configuration and pitch and as indicated on the Drawings.

12.C. Gable Flashings: Provide manufacturer's standard units based on roof configuration and pitch and as indicated on the Drawings.

12.D. Valleys: Provide manufacturer's standard units based on roof configuration and pitch and as indicated on the Drawings.

12.E. Sidewall: Provide manufacturer's standard units based on roof configuration and pitch and as indicated on the Drawings.

12.F. Endwall Flashing: Provide manufacturer's standard units based on roof configuration and pitch and as indicated on the Drawings.

07610-15 12.G. Transition Flashing: Provide manufacturer's standard units based on roof configuration and pitch and as indicated on the Drawings.

12.H. Gambrel Flashing: Transition Flashing: Provide manufacturer's standard units based on roof configuration and pitch and as indicated on the Drawings.

12.I. Chimney Flashing: Provide manufacturer's standard units based on roof configuration and pitch and as indicated on the Drawings.

2.13 ACCESSORlES

13.A. Pipe Boots: Provide manufacturer's standard units based on roof configuration.

13.B. Electrical Boots: Provide manufacturer's standard units based on roof configuration.

13.C. Peel and Seal Tape: Provide manufacturer's standard seals.

13.D. Touch-up Paint: Provide manufacturer's standard touch-up paint.

13.E. Butyl tape: Provide manufacturer's standard products.

13.F. Titebond: Provide manufacturer's standard products.

13.G. Low Profile Insulation: Provide manufacturer's standard units based on roof configuration and pitch and as indicated on the Drawings.

13.H. Pancake Screws: Provide manufacturer's standard products.

13.I. Exposed Fasteners: Provide manufacturer's standard products. 13.I.1. Long-life Zinc-Aluminum cap screws. 13.I.2. Long-life Stainless Steel cap screws. 13.I.3. Non-warranted screws.

13.J. Stainless Rivets: Provide manufacturer's standard products.

13.K. Lap Screws: Provide manufacturer's standard products. 13.K.1. Long-life Zinc-Aluminum cap screws. 13.K.2. Long-life Stainless Steel cap screws. 13.K.3. Non-warranted screws.

PART 3 EXECUTION

07610-16 3.1 EXAMINATION

1.A. Do not begin installation until substrates have been properly prepared.

1.B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

3.2 PREPARATION

2.A. Clean surfaces thoroughly prior to installation.

2.B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3.3 INSTALLATION

3.A. Install in accordance with manufacturer's instructions.

3.4 PROTECTION

4.A. Protect installed products until completion of project.

4.B. Touch-up, repair or replace damaged products before Substantial Completion.

END OF SECTION