9.3.3 Centre or mixed use code

9.3.3.1 Application

1.1 This code applies to assessing a material change of use or building work if: self-assessable or assessable development where this code is an applicable code identified in the assessment criteria column of a table of assessment for a material change of use (section 5.5), building work (section 5.7) or a neighbourhood plan (section 5.9); or impact assessable development for a use of a commercial or retail nature.

2.1 When using this code, reference should be made to section 1.5 and section 5.3.3.

Editor's note—For a proposal to be self-assessable, it must meet all the self-assessable outcomes of this code and any other applicable code. Where it does not meet all self-assessable outcomes, the proposal becomes assessable development and a development application is required. Where a development application is triggered, only the specific acceptable outcomes that the proposal fails to meet needs to be assessed against the corresponding assessable acceptable outcomes or performance outcomes. Other self-assessable outcomes that are met are not assessed as a part of the development application.

Note—Development for a multiple dwelling or the multiple dwelling component of a mixed use development is also assessed against the Multiple dwelling code and any prescribed secondary code.

Note—Enclosure of car parking areas extending more than 1m above ground level is considered assessable development.

Note—Where this code includes performance outcomes or acceptable outcomes that relate to: air quality assessment, guidance is provided in the Air quality planning scheme policy; crime prevention through environmental design, guidance is provided in the Crime prevention through environmental design planning scheme policy; design for the reduction of graffiti, guidance is provided in the Graffiti prevention guidelines planning scheme policy; the Independent design advisory panel, guidance is provided in the Independent design advisory panel planning scheme policy; infrastructure design and construction works, guidance is provided in the Infrastructure design planning scheme policy; noise impacts assessment, guidance is provided in the Noise impact assessment planning scheme policy; the selection of planting species, guidance is provided in the Planting species planning scheme policy; refuse and recycling, guidance is provided in the Refuse planning scheme policy; structure planning, guidance is provided in the Structure planning planning scheme policy; transport, access, parking or servicing provisions, guidance is provided in the Transport, access, parking and servicing planning scheme policy; significant vegetation, guidance is provided in the Vegetation planning scheme policy.

9.3.3.2 Purpose

(1) The purpose of the Centre or mixed use code is to assess the suitability of development to which this code applies.

3.1 The purpose of the code will be achieved through the following overall outcomes:

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 (a) Development involving a new use in an existing building is appropriate for its location and does not negatively impact on the amenity of the local area or adjoining residents.

Development is tailored to the location of the site considering its intensity of activity, range of uses and proximity to higher capacity public transport services, government services, community facilities and other infrastructure and presents a coordinated and integrated building, open space and landscaping response to the street and adjoining public spaces.

Development involving new premises contributes to the economic activity and vitality of the location and is appropriate to its relative catchment and expected hours of operation.

Development ensures that the site area and frontage is sufficient for the scale and form of development and is sufficient to manage the impacts to a lower intensity use or a sensitive use in and adjoining the development.

Development contributes to the overall structure and integration of the site with the local area and: does not isolate or negatively impact on the development potential of adjoining sites; provides opportunities for the integration of pedestrian access and parking across adjoining sites, to enhance permeability, legibility, safety, convenience and comfort for all users.

Development provides physical and visual connections to high-frequency transport nodes, contributing to the overall pedestrian network to support an enduring pedestrian-oriented environment.

Development intensity, bulk, scale and form is:

(i) consistent with the intended function, spatial arrangement and type of centre or corridor, as expressed in the zone, zone precinct and neighbourhood plan outcomes;

(ii) articulated and detailed to achieve a positive streetscape outcome.

Development provides adaptable and flexible space, particularly on the lower levels of a building, to support use and activity changes over time.

Development for a building exhibits subtropical design elements and a visually appealing street edge that continues local character form such as traditional strip shopfronts, where appropriate, to contribute to Brisbane's character and identity.

Development ensures that the design of buildings reflects an intense urban form while providing open space and landscaping appropriate to the use and scale of the development, and which positively contributes to the streetscape character and local identity.

Development provides a range of public, communal and private open spaces on site to support both public usage and building occupant needs which are distinct and afforded the appropriate level of access and privacy. Development provides high quality on-site landscaping that contributes to the subtropical landscape character and microclimate of the locality and site with deep- planting areas for the protection of significant vegetation and establishment of large, subtropical shade trees.

Development provides car parking which is legible and clearly distinct for the different user groups of a mixed use development such as customers and staff, residents and visitors.

Development provides safe, convenient and accessible on-site vehicle parking that does not adversely impact on the quality and amenity of an adjoining streetscape, public space or residents.

Development provides an active frontage and integrated streetscape interface that creates a pedestrian-scaled, comfortable, attractive, sheltered and safe public realm, and supports pedestrian activity on Brisbane's subtropical streets.

Development uses side boundary setbacks and built form height transitions in or adjoining a low density residential area to manage the interface with those areas and reflect the amenity, privacy, form and character of those areas.

Development manages visual, air, odour and noise impacts through appropriate use mix, siting and building design, to achieve a level of amenity consistent with the zone, zone precinct and neighbourhood plan outcomes, and recognising that residential amenity in a centre and mixed use area will not be to the same level that might be expected in residential zones and areas.

Development, particularly on landmark sites, retains and supports site features, such as views, heritage, significant vegetation and significant corner sites, and provides character and design elements to strengthen local identity and city distinctiveness.

9.3.3.3 Assessment criteria

The following table identifies the assessment criteria for self-assessable and assessable development.

Table 9.3.3.3.A—Criteria for self-assessable and assessable development Performance outcomes Acceptable outcomes Section A—If for self-assessable or assessable development PO1 AO1.1 Development: Development: 4.1 has hours of operation which are (a) for accommodation activities, dwelling unit controlled so that the use does not or emergency services has unlimited hours of detrimentally impact on the amenity of operation; adjoining residents; 6.1 for a club, if licensed, function facility, 5.1 where not located in a Special hotel or nightclub entertainment facility entertainment precinct identified in a does not generate noise which is clearly neighbourhood plan, does not result in audible and detectable, or impacts on the noise emissions that exceed the noise amenity of a resident, in a dwelling or (planning) criteria in Table 9.3.3.F low other sensitive use; frequency noise criteria in Table Note—Development for a club, if licensed, function facility, 9.3.3.3.G and night-time noise criteria in hotel or nightclub entertainment facility is not expected to Table 9.3.3.3.H in a sensitive zone or a achieve this outcome.

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 nearby sensitive use. 7.1 for any other use: Note—A noise impact assessment report prepared in 8.1 where in the Principal centre zone or accordance with the Noise impact assessment planning Major centre zone has unlimited hours of scheme policy can assist in demonstrating achievement of operation; this performance outcome. 9.1 where in the District centre zone, Neighbourhood centre zone or Mixed use zone: 10.1has hours of operation, including for deliveries, which are limited to 6am to 10pm; or 11.1does not generate noise which is clearly audible and disturbing in a dwelling or other sensitive use; 12.1where in any other zone: (A) has hours of operation, including for deliveries, which are limited to 6am to 8pm; or 13.1does not generate noise which is clearly audible and disturbing in a dwelling or other sensitive use. AO1.2 Development ensures mechanical plant or equipment is acoustically screened from an adjoining sensitive use. Note—Mechanical plant includes generators, motors, compressors and pumps e.g. air-conditioning, refrigeration or cold room motors

PO2 AO2 Development protects the visual amenity of the Development including mechanical plant, refuse centre, public realm and any adjacent residential and recycling area, vent and exhaust is not visible use. from: (a) a street or public space; 14.1an adjacent residential use. Note—Mechanical plant includes generators, motors, compressors and pumps e.g. air-conditioning, refrigeration and coldroom motors. PO3 AO3.1 Development: Development ensures that air pollutants, including (a) avoids or minimises air emissions; odour, are not released external to the development except where complying with AO3.2 (b) complies with the air quality (planning) and AO3.3. criteria in Table 9.3.3.3.I and odour criteria in Table 9.3.3.3.J in a sensitive zone or sensitive AO3.2 use. Development ensures that if food and cooking Note—An air quality impact report prepared in accordance odour is released, exhaust vent outlets are with the Air quality planning scheme policy can assist in discharged vertically and directed away from any demonstrating achievement of this performance outcome. sensitive use with the following constraints: (a) separated by a minimum of 6m from a sensitive use, including any outdoor air intake of a sensitive use; (b) does not cause an odour or air emission which is detectable and disturbing at a sensitive use. AO3.3 Development ensures that exhaust vents from any car park or bus station are separated from any sensitive use by a minimum of 15m. PO4 AO4.1 Development for outdoor lighting: Development provides for outdoor lighting: (a) does not have an adverse impact on any (a) with technical parameters, design, person, activity or fauna because of light installation, operation and maintenance which emissions, either directly or by reflection; comply with the requirements of AS 4282- 15.1ensures that the external appearance of 1997 Control of the obtrusive effects of the premises is similar to adjoining non- outdoor lighting; residential premises with lighting that 16.1which maintains a minimum of 20lux at does not impact adversely on centre the footpath level where in a zone in the amenity and the public realm. centre zones category or the Mixed use zone. Note—The effect of outdoor lighting is to be mitigated where a window of a habitable room of a nearby dwelling will be illuminated beyond maximum permissible values outlined in AS 4282-1997 Control of the obtrusive effects of outdoor lighting. AO4.2 Development ensures that floodlighting is restricted to types that do not produce an upward component of light where mounted horizontally such as a full cut off luminar. AO4.3 Development facade has no flashing lights. PO5 AO5 Development for urban purposes is serviced Development provides for all lots to be provided adequately with: with reticulated water supply and sewerage. (a) water supply which meets the stated standard of service for intended use and fire-fighting purposes; 17.1waste disposal. Additional criteria for development if for a food and drink outlet PO6 AO6 Development mitigates impacts on residential Development provides for external dining or amenity in or adjoining the building through: entertainment areas to be: (a) providing an outdoor dining area that is (a) located in or directly adjacent to the public appropriately located; realm; (b) ensuring external dining and entertainment (b) visually and acoustically screened from an areas are visually and acoustically screened adjoining dwelling. from an adjoining dwelling.

Additional criteria for development if for a garden centre or hardware and trade supplies PO7 AO7.1 Development contributes to the creation of a Development provides for the gross floor area for vibrant and attractive public realm and centre any individual tenancy to be no greater than amenity. 1,500m2 if in the Centre frame zone precinct of the Mixed use zone or the Corridor zone precinct of the Mixed use zone. AO7.2 Development:

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 (a) is not located on land identified as active frontage – primary; or 18.1if located on land identified as active frontage – primary, is located behind a highly active non-residential use. AO7.3 Development if located on an active frontage – secondary: (a) ensures that: (i) separate tenancies do not amalgamate to create a frontage wider than 20m; 19.1windows are not obscured with signage or fixtures; 20.1the tenancy interior is able to be viewed from the street; or 21.1is located behind active non-residential uses. Additional criteria if for development if a shop or shop component of a shopping centre PO8 AO8 Development contributes to the creation of a Development provides for a gross floor area of no vibrant and attractive public realm and centre greater than 1,500m2 for any individual tenancy in amenity. the Centre frame zone precinct of the Mixed use zone or Corridor zone precinct of the Mixed use zone. Additional criteria for development if for a showroom PO9 AO9.1 Development contributes to the creation of a Development provides a gross floor area of no vibrant and attractive public realm and centre greater than 1,500m2 for any individual tenancy if amenity. in the Centre frame zone precinct of the Mixed use zone or the Corridor zone precinct of the Mixed use zone. AO9.2 Development located on an active frontage – primary: (a) ensures that: (i) separate tenancies do not amalgamate to create frontages wider than 10m; 22.1windows are not obscured with signage or fixtures; 23.1the tenancy interior is able to be viewed from the street; or 24.1is located behind active non-residential uses. Note—Highly active non-residential uses are required on an active frontage – primary to create the greatest degree of pedestrian activity and interaction. These uses are mostly accommodated in small individual tenancies with narrow building frontages, such as shops, restaurants and cafes. Section B—If for assessable development involving demolition PO10 AO10 Development provides that a vacant development Development for the demolition of a building, site presents an attractive temporary parkland and where redevelopment is delayed for more than 3 does not impact adversely on the visual amenity months, ensures the site is: of the centre or mixed use area or the public (a) cleared of all rubble, debris and demolition realm. materials; 25.1turfed so it can be mowed; 26.1landscaped with perimeter planting consisting of advanced specimens of fast-growing species in compliance with the Planting species planning scheme policy; 27.1provided with drainage to prevent ponding; 28.1maintained so that there is no sediment run-off onto adjacent premises, roads or footpaths; 29.1provided with public access where public safety can be maintained; 30.1provided with at least 50% transparent street-front fencing if fenced; 31.1maintained to ensure no nuisance or amenity impacts to adjacent premises, residents, roads or footpaths. Section C—If for assessable development PO11 AO11 Development ensures that the site is of sufficient Development ensures that: area and frontage width to: (a) the site area and frontage width is in (a) achieve convenient and safe vehicle, compliance with the requirements identified pedestrian and cyclist access; in a neighbourhood plan; or 32.1minimise traffic hazard and 40.1if no neighbourhood plan applies, or the inconvenience; neighbourhood plan does not address the 33.1achieve sufficient car parking and site area and frontage width, the site area 2 manoeuvring on site for short-term and is a minimum of 800m and has a long-term use by customers, building minimum frontage width of 20m. occupants, residents, visitors and service Note—The site frontage is measured at the boundary line on providers; the primary road. 34.1accommodate adequate services areas to minimise adverse impacts on neighbours; 35.1allow service providers convenient access to service areas; 36.1minimise the proportion of frontage dedicated to driveways; 37.1manage building bulk, scale and form; 38.1accommodate sufficient areas of deep planting and landscaping for amenity and recreation and to contribute to an attractive subtropical public realm; 39.1allow room for useable open space to promote casual surveillance and good public realm interface. PO12 AO12 Development does not isolate or negatively Development ensures that: impact on the development potential or future (a) the site area and frontage width of an amenity of an adjoining site. adjoining site within a zone in the centre zones category or the Mixed use zone: (i) complies with the minimum requirements

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 set out in a neighbourhood plan; or 41.1does not isolate lots less than 800m2 in area or with a frontage width less than 20m or prohibit access to an existing access easement arrangement or laneway; or 42.1a concept plan for the development demonstrates that development can be physically achieved on an adjoining site at a later stage, commensurate with the intent of the zone and zone precinct or neighbourhood plan requirements. PO13 AO13 Development enhances the role and function of Development is in accordance with: the centre or mixed use area as a place of (a) the structure outlined in a neighbourhood economic and community activity considering its plan, an existing development approval or a strategic location, form and character intent and preliminary approval; or the catchment which it services, through its 53.1if no neighbourhood plan applies, or the overall structure and integration in its location neighbourhood plan does not address with use and site planning including building, overall structure requirements, no open space, landscape and parking which: acceptable outcome is prescribed. (a) retain or respect valued site features; 43.1reflect local valued streetscape forms, features and character; 44.1contribute to the desired character and form of the local area; 45.1align buildings and towers to the street pattern and respects the continuity of street facades; 46.1are transit supportive; 47.1connect with the neighbourhood or local structure; 48.1provide direct and convenient site access for pedestrians and cyclists to local transport networks, key destinations and public transport facilities; 49.1provides for safe vehicle access; 50.1provides opportunities for integrated access and parking with adjoining developments; 51.1locates uses to minimise impacts on adjoining residents; 52.1assists with mitigation of air and noise quality impacts on the health and amenity of building occupants and residents. Refer to Figure a. Note—A structure plan prepared in accordance with the Structure planning planning scheme policy can assist in demonstrating achievement of this performance outcome. PO14 AO14 Development adjoining or in the vicinity of a Development frontage is treated as an active railway or busway station is transit supportive to: frontage–primary where within 200m walking (a) facilitate safe, logical and direct pedestrian distance of a dedicated public pedestrian access access to the railway and busway station point of a railway or busway station. entry points; 54.1activate public space and the edges of the railway or busway station environment; 55.1create vibrant and attractive street environments; 56.1enable casual surveillance of streets, public spaces and the immediate station environment entries and platform; 57.1provide a high level of personal and community safety, and physical and visual integration with the station. Refer to Figure b. PO15 AO15.1 Development protects, provides or supports as Development provides public spaces and links, appropriate public spaces and structuring including public roads and verges, parks or urban elements within the centre or mixed use area and common and cross block links, in the locations site to: identified in: (a) provide pedestrian and cycle connections to (a) an overlay; or key public transport facilities, community (b) a neighbourhood plan; or facilities or services and the surrounding (c) an existing development approval; or neighbourhood; (d) a preliminary approval; or 58.1create a permeable and interconnected activity centre or corridor; (e) as otherwise identified as part of a structure planning process as part of development. 59.1provide sufficient open space for pedestrian activity and use by building Note— occupants, residents, customers and Refer to the Streetscape hierarchy overlay and code for visitors. further information.

Refer to the Park planning and design code for the design of parks.

Refer to the Infrastructure design code for further guidance on the design of public infrastructure.

AO15.2 Development provides publicly accessible spaces and links (privately owned), including plazas, arcades, pedestrian pathways, shelters and queuing areas for public transport, in the locations identified in: (a) an overlay; or 60.1a neighbourhood plan; or 61.1an existing development approval; or 62.1a preliminary approval; or 63.1as otherwise identified as part of a structure planning process as part of development. AO15.3 Development for a park, public open space or plaza, is co-located with community services and civic facilities. PO16 AO16 Development provides a land use mix which: Development provides a land use mix or maximum gross floor area or plot ratio for

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 (a) supports the intended function of the centre particular uses that: or mixed use area; (a) is in compliance with any limit set in a 64.1does not prevent commercial or neighbourhood plan; or employment growth; 69.1if no neighbourhood plan applies, or no 65.1includes: requirements are specified in a (i) complementary uses such as retail, neighbourhood plan: employment, residential and community (i) is no more than 50% residential in a facilities; Principal centre zone or Major centre 66.1uses that provide for the everyday needs zone; of the local community; 70.1or otherwise no acceptable outcome is 67.1a fine grain of uses particularly on active prescribed. frontages and adjoining public footpaths and spaces; 68.1residential uses in centres including live– work configurations. PO17 AO17 Development for a residential use does not Development for a residential use is not located compromise the economic function or activity of on the ground floor where in a zone in the centre a centre and street level activation. zones category or the Mixed use zone, except if: (a) located behind an active frontage with a non- residential use; or 71.1located in the Frame zone precinct of a zone in the centre zones category or Corridor zone precinct of a zone in the centre zones category and providing a transition to adjoining lower intensity or residential neighbourhoods; or 72.1in a Mixed use zone the ground floor of which includes adaptable building design; or 73.1short-term accommodation that has a foyer or a non-residential use providing a minimum of 50% active frontage to the street or public space. PO18 AO18 Development minimises the adverse impact of a Development provides: use on building occupants and residents in or (a) co-location of low impact commercial adjoining the site through appropriate land use activities where air or noise impacts are not mix. detectable and disturbing in a dwelling or Note—Low impact commercial activities are shops, banks, other sensitive use; offices and similar. 74.1co-location of uses with potential air or noise impacts away from sensitive uses; 75.1mitigation of impacts resulting from co- location of food and drink outlet uses such as a restaurant with residential uses in the same building; 76.1that nightclub entertainment facilities are not co-located with residential or other sensitive development within the same building; 77.1that the location of exhaust or ventilation outlets from food outlets, drycleaners, salons, car parks and bus stations as far from a sensitive use as practicable; 78.1adequate separation distances between service stations and any sensitive use; 79.1dwelling balconies and windows do not overlook ventilation stacks and bulk waste bin storage areas. PO19 AO19 Development ensures that the building bulk and Development is contained within the building scale is consistent with the intended form and envelope for the site by applying: character of the centre, mixed use or local area (a) the maximum building height; considering: (b) building height transition requirements, (a) existing buildings to be retained; where required; (b) existing significant vegetation; 84.1front, rear and side setback requirements; 80.1significant infrastructure constraints; 85.1building separation requirements; 81.1adjoining existing and proposed building 86.1car parking setback requirements; heights; 87.1active frontage requirements for stand- 82.1adjoining existing and proposed building alone shopping centres or shops or for setbacks and separation of buildings development in traditional strip centres necessary to ensure impacts on amenity or corridors. and privacy are minimised; Refer to Figure c and Figure d examples. 83.1building height transitions where required. Note—The building envelope must include all requirements from any applicable overlay codes or a neighbourhood plan.

Note—This can be demonstrated by a building envelope plan, elevations and sections. PO20 AO20 Development ensures that the building height is Development ensures that the maximum building consistent with the centre or mixed use area intent height is in compliance with: and local and street context considering: (a) a neighbourhood plan; or (a) the size of the lot; 95.1if no neighbourhood plan applies or no 88.1the scale of development reinforcing the requirements are specified in the preferred city-wide form; neighbourhood plan, the requirements in 89.1proximity to high-frequency public Table 9.3.3.3.B. transport services; Note—The building height is determined by the number of 90.1the height of existing adjoining buildings storeys rather than metres except where varied by a and proposed heights; neighbourhood plan. Some neighbourhood plans may also specify a maximum height of buildings in metres. 91.1street conditions such as street width; 92.1the topography of an area and site slope; Note—Roofs are excluded from the calculation of maximum height of buildings to encourage interesting subtropical roof 93.1view points and corridors; forms able to respond to solar orientation and site context. 94.1solar access to key public spaces. PO21 AO21.1 Development where identified in a neighbourhood Development where identified in a neighbourhood plan as a building height transition, or where plan as a building height transition or where sharing a common boundary with, or located sharing a common boundary with premises in the fronting a minor road that is opposite, premises in Low–medium density residential zone, Low the Low–medium density residential zone, Low density residential zone or Character residential density residential zone or Character residential zone provides a building height transition which zone provides buildings that are reduced in bulk complies with: and form to provide a transitional built form of a (a) a neighbourhood plan; or; compatible scale which protects the amenity of 98.1if no neighbourhood plan applies, or no lower density residential areas bordering centre or requirements are specified in the mixed use areas by: neighbourhood plan, the following: (a) stepping down in height and scale; (i) the building height within 10m of the 96.1minimising impacts including those from common boundary is no more than 1

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 overlooking and visual dominance; storey greater than the maximum 97.1maintaining adequate levels of natural acceptable outcome for building height ventilation and light penetration to a on the adjoining site; habitable room, balcony and private open 99.1the building height within 20m of the space. common boundary is no more than 2 storeys greater than the maximum acceptable outcome for building height on the adjoining site; 100.1 all structures, except adjoining boundary fences, are set back a minimum of 4m from the common boundary; 101.1 an acoustic and visual screen fence of 2m height is provided on the common boundary. AO21.2 Development where located fronting a minor road that is opposite premises in the Low–medium density residential zone, Low density residential zone or Character residential zone provides a building height transition which complies with: (a) a neighbourhood plan; or 102.1 if no neighbourhood plan applies or no requirements are specified in the neighbourhood plan, the following: (i) the building height within 10m of the front boundary is no more than 2 storeys greater than the maximum acceptable outcome for building height on a site located on the opposite side of the minor road; 103.1 all structures, except boundary fences, are set back a minimum of 4m from the front boundary; 104.1 buildings are provided with modulation and articulation with variations in the wall and roof plane every 10m. Note—Minor road is defined in the Transport, access, parking and servicing planning scheme policy. Where mixed residential and non-residential development, site access may be provided from a minor road for the residential component of the development. PO22 AO22 Development ensures that the front boundary Development ensures that the front boundary setbacks: setback for non-residential and residential (a) positively define the street edge; development in a zone in the centre zones category or the Mixed use zone are in compliance 105.1 relate to the existing streetscape with: and setback pattern and reinforce the preferred character and form intent; (a) a neighbourhood plan; or 106.1 provide for connections 112.1 if no neighbourhood plan between footpaths, public spaces and applies or no requirements are specified private entries where level differences in the neighbourhood plan, the are proposed; requirements in Table 9.3.3.3.C. 107.1 provide for the queuing of patrons at entertainment venues; 108.1 consider waiting areas at bus stops, taxi ranks and display windows; 109.1 where a residential use and outside the core of a centre, takes on a more residential interface with the street; 110.1 where facing lower intensity development or a residential neighbourhood provide for an appropriate interface and transition; 111.1 provide for deep-planting areas and landscaping where a built to the front boundary edge is not required. PO23 AO23 Development ensures that the rear boundary and Development ensures that the rear and secondary secondary street setbacks: street boundary setbacks for non-residential and (a) provide for deep-planting areas; residential development in a centre or mixed use or for a centre activity or mix of uses are in 113.1 support building separation to compliance with: provide visual and acoustic privacy without screening where residential uses (a) a neighbourhood plan; or are adjoining or proposed; 116.1 if no neighbourhood plan 114.1 maximise the opportunity to applies or no requirements are specified retain and protect existing mature in the neighbourhood plan, the vegetation; requirements in Table 9.3.3.3.C. 115.1 enable a suitable frontage treatment to be presented where there is a transition to a residential neighbourhood. PO24 AO24 Development ensures that the side boundary Development ensures that side boundary setbacks setbacks: for non-residential and residential development in (a) minimise the impact of development on the a centre or mixed use or for a centre activity or amenity and privacy of adjoining existing mix of uses are in accordance with: residents; (a) a neighbourhood plan; or 117.1 contribute to the rhythm and 120.1 if no neighbourhood plan pattern of the streetscape in keeping with applies or no requirements are specified the intended neighbourhood character; in the neighbourhood plan, the 118.1 provide for breezes and sunlight requirements in Table 9.3.3.3.C. where a residential use is included on upper levels above podium levels; 119.1 consider future development. PO25 AO25.1 Development ensures that the separation of Development ensures that the building separation buildings within a site and to an adjoining existing within a site and to adjoining buildings is in or future building which includes a residential compliance with Table 9.3.3.3.E. dwelling: Note—This is demonstrated by a site context plan that (a) is consistent with the form and character includes adjoining and adjacent buildings and strategies to intent for the local area; address separation issues. 121.1 is located to provide residential AO25.2 amenity including access to natural light, Development ensures that the building separation sunlight and breeze; to an adjoining residential building: 122.1 provides a degree of visual (a) complies with Table 9.3.3.3.E; or privacy via site planning and design

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 without a reliance on fixed screening; 124.1 positions the primary balcony or 123.1 reasonably addresses and private open space to street or rear; considers the amenity of adjoining 125.1 offsets balconies or habitable residents and future development rooms so they are positioned outside the potential. cone of vision of existing or approved habitable rooms or outdoor spaces; or 126.1 uses moveable or adjustable screening to regulate privacy between lots or dwellings which do not exceed balcony screening acceptable outcomes. Note—Separation distances are intended to protect amenity and provide for private open spaces on upper levels that do not require full screening for privacy.

Note—Considered site planning and design and strategies such as offsetting balconies, the location of private space, selective screening and other design elements can reduce the boundary separation requirements. PO26 AO26 Development is of an intensity that supports both Development has a gross floor area or plot ratio the strategic and local role and function of the which: centre or mixed use area and the development of a (a) complies with a neighbourhood plan; or vibrant public realm considering the capacity of 127.1 if no neighbourhood plan infrastructure. applies or a neighbourhood plan does not specify a gross floor area or plot ratio, is provided for in a building contained within the building envelope that does not exceed the maximum building footprint for the site. PO27 AO27 Development has a building footprint or site cover Development provides a maximum building which: footprint or site cover which: (a) is of an appropriate form and intensity for the (a) complies with the requirements in a activity centre or mixed use location; neighbourhood plan; 128.1 balances built form with open 131.1 if no neighbourhood plan space, parking and landscaping at ground applies or no requirements are specified level; in a neighbourhood plan, the maximum 129.1 limits areas of external surface building footprint or site cover is 90%. car parking; Note—The building footprint or site cover includes at-grade 130.1 provides for landscaping and car parking areas that are covered with shelter. Enclosed car deep planting areas. parking areas are included if they protrude more than 1m above ground level. PO28 AO28.1 Development ensures that the podium building Development with podium design including forms: setback: (a) positively contribute to centre or mixed use (a) complies with the requirements in a character; neighbourhood plan; 132.1 are consistent with the local or 137.1 if no neighbourhood plan street form and character intent; applies, or if no requirements are 133.1 are proportional to the total specified in the neighbourhood plan: height; (i) is set back in accordance with 134.1 do not negatively impact on the Table 9.3.3.3.C and Table 9.3.3.3.D if streetscape; parking is included in a podium; 135.1 do not negatively impact on the 138.1 is not built to the boundary on a boundary where a building height amenity of adjoining residents or transition is required; building occupants; 139.1 provides a continuous frontage 136.1 are set back considering the built to the alignment where continuity height, length, degree of enclosure and with adjoining buildings is important; treatment of walls. 140.1 is of a height that matches to the existing streetscape and to neighbouring buildings; 141.1 does not exceed 3 storeys, if no podium or parapet line is established in the immediate streetscape. AO28.2 Development ensures that podium walls: (a) are built to the side or rear boundary of an allotment; 142.1 are blank; 143.1 have no windows or openings. PO29 AO29 Development ensures that built to boundary walls Development ensures that its built to boundary do not negatively impact on the amenity of walls are: adjoining residents or building occupants. (a) not located on a boundary adjoining land located within the Low density residential zone or Character residential zone; 144.1 not located on a boundary where a building height transition is required; 145.1 not located in front or rear setbacks; 146.1 constructed with pre-finished and low- maintenance materials. PO30 AO30 Development for a building in a centre or mixed Development includes a minimum floor-to-ceiling use area provides for adaptable use over time, in height of 4.2m on the ground storey if: particular on the ground storey and lower levels (a) identified as an active frontage in a with: neighbourhood plan; or (a) a mix of adaptable floor plates at ground 148.1 in the Principal centre zone, storey and podium levels; Major centre zone, District centre zone 147.1 higher floor-to-ceiling heights, or Mixed use zone; or capable of accommodating commercial, 149.1 within 200m walking distance retail or other non-residential uses at of a dedicated public pedestrian access different stages of the building’s life point of a railway or bus station. cycle. PO31 AO31.1 Development ensures that building bulk and scale: Development ensures that the length of a uniform (a) is consistent with the form and character treatment of an elevation above ground level intent for the local area and street; without variation, substantial articulation or openings is no more than 30m. 150.1 is reduced by design elements to provide: Note—Substantial articulation is a full break of 6m or a change in building line of 2m plus or minus for a length not (i) visual interest and contribution to the less than 5m. character of the centre or mixed use area; 151.1 reflection of valued local form AO31.2 elements such as podium or parapet Development reduces building bulk by a heights in traditional strip shopping combination of: centres; (a) balconies orientated towards the street;

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 152.1 adequate amenity for building 156.1 variation in materials, colours, occupants and residents in terms of or textures including between levels; access to natural light and ventilation; 157.1 recessions and projections in the 153.1 a comfortable and attractive roof and wall plane; pedestrian environment; 158.1 variations in the building form. 154.1 a building base which exhibits a AO31.3 human-scale and fine-grain building rhythm; Development maximises recessed forms and openings around the building perimeter to allow 155.1 variations in horizontal and external space to merge with the interior of the vertical profile. building, except where they would compromise safety and security. AO31.4 Development of the lower 3 storeys of the building includes: (a) awnings and sun-protection devices; 159.1 operable elements within the facade; 160.1 elements of a finer scale than the main structural framing; 161.1 display windows, showcases or public art where identified as an active frontage. Refer to Figure l. PO32 AO32.1 Development of buildings is finished with high- Development: quality materials, selected for their durability and (a) respects and reflects the architectural theme the contribution they make to the character of the in the area; centre or mixed use area. 162.1 respects the traditional frontages, facades, architectural qualities and traditional materials of buildings within the area; 163.1 does not necessarily imitate historical architectural styles. Refer to Figure l. AO32.2 Development provides materials and finishes which are all easily maintained and do not readily stain, discolour or deteriorate. PO33 AO33.1 Development for a building exhibits subtropical Development includes ventilation in and around a design elements to support a building’s occupant, building through strong sectional and facade resident and user comfort and outdoor activities articulation, breezeways, open courtyards and and living. landscaped areas. AO33.2 Development includes weather protection and sun shading to: (a) all pedestrian entries; 164.1 shopfronts; 165.1 publicly accessible pedestrian connections; 166.1 external doors and windows to habitable rooms; 167.1 outdoor spaces intended for cafe or restaurant use. AO33.3 Development: (a) incorporates deep recesses, eaves and sun- shading devices on the north-facing building facades; (b) is shaded and incorporates elements such as adjustable screens, awnings or pergolas, green walls or planting on the west-facing building facades.

PO34 AO34.1 Development for rooftops and building caps: Development provides rooftops and building caps (a) is interesting, subtropical and contextually which: and climatically appropriate in form; (a) contribute to the architectural distinction of 168.1 is responsive to orientation and the building and roofs; solar access; 170.1 include combinations and 169.1 is attractive and not marred by a variations of forms created through cluttered display of plant and equipment. pitches, gables, skillions or other features. Note—The building height is determined by the number of storeys and excludes roofs, except where varied by a AO34.2 neighbourhood plan, to encourage interesting, subtropical Development for rooftops and building caps are and contextually appropriate roof forms. designed to: (a) incorporate and screen service structures, lift motor rooms, mechanical plant and equipment as architectural features; 171.1 enable the future inclusion of service structures, lift motor rooms and mechanical plant and equipment, such as satellite dishes and telecommunications facilities, in an unobtrusive manner.

AO34.3 Development where rooftops are used for open space, ensures plant and equipment is visually and acoustically screened from the communal open space. PO35 AO35.1 Development provides shelter for pedestrian Development for a pedestrian shelter is provided movement: by an awning which: (a) on a street frontage; (a) is consistent with the character of the centre; 172.1 through a site with a cross block 174.1 abuts footpaths; link; 175.1 is provided and maintained by 173.1 to key building entrances or the building owner on their premises; publicly accessible parts of the site. 176.1 protects the normal flow of pedestrians; 177.1 is continuous across the frontage of a site; 178.1 aligns to provide continuity with shelter on an adjoining premises; 179.1 is a minimum of 3.2m and is generally not more than 4.2m above

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 pavement height; 180.1 extends from the face of the building or the premises line; 181.1 does not extend past a vertical plane 1.5m inside the kerb line to enable street trees to be planted and grow; 182.1 has a 0.5m clearance to any tree trunk and main branches; 183.1 aligns with existing awnings if the verge has been widened; 184.1 is cantilevered from the main building with any posts within the verge being non load bearing; 185.1 uses materials that provide appropriate shade. Refer to Figure m. AO35.2 Development for an awning over a footpath is lit with a lighting system which: (a) is in compliance with AS/NZS 1158.3.1:2005 Lighting for roads and public spaces, Category P3 and AS 4282-1997 Control of the obtrusive effects of outdoor lighting 186.1 provides a minimum of 20lux at ground level. PO36 AO36.1 Development provides site entrances which: Development entrances are clearly visible from (a) define the threshold between public and the street, and are not obscured by fencing, walls, private space; advertising or dense landscaping. 187.1 provide safe, secure and AO36.2 convenient access to the site for building Development provides for: occupants and visitors; (a) a clear path of travel from the public footpath 188.1 provide a sufficiently scaled and to building entry; sheltered entry and meeting space; 192.1 activity generators adjacent to 189.1 provide clear building signage the entrance; and numbering for emergency access; 193.1 seating or other facilities such 190.1 provide lighting; as short-term bicycle parking near the 191.1 provide conveniently located entry. mailboxes. AO36.3 Development provides: (a) signage and cues to distinguish between public areas, publicly accessible private areas and private areas; (b) street numbers and building names which are clearly identifiable from the street for pedestrians and emergency access. Note—Cues to differentiate territory may include fences, vegetation, lighting, footpath detailing and changes in level.

PO37 AO37.1 Development of buildings defines the street edge Development provides a front building elevation and reinforces the desired character of the centre that is parallel or nearly parallel to the street or corridor through: frontage. (a) orientation to the street; AO37.2 194.1 minimal front boundary Development is orientated to overlook streets and setback; other public spaces with windows and balconies 195.1 providing overlooking and located on upper levels, designed to provide casual surveillance from upper level casual surveillance opportunities. balconies and windows; Refer to Figure l. 196.1 clearly defined building AO37.3 entrances; Development for a building which is not located 197.1 high-quality finishes at the on the front boundary, ensures the setback: ground-storey pedestrian level. (a) is open and accessible for pedestrians along its entire length and width; 198.1 is clear of columns and other obstructions; 199.1 has a pavement matching the gradient of the adjoining pavement and connecting pedestrian areas on neighbouring sites; 200.1 connects without any lip or step to adjoining pavements or abutting pedestrian areas on neighbouring sites. Refer to Figure m. AO37.4 Development for steps, escalators, ramps or lifts is set back 1.2m from the main building line to maximise pedestrian flow and safety and allow for adequate waiting space. PO38 AO38 Development for a building 8 storeys and over Development provides wind mitigation for a ensures that the design mitigates the impacts of building which is 8 storeys to 15 storeys that: ground-level wind acceleration on pedestrians and (a) is in accordance with a neighbourhood plan; building occupants, considering the site context or and neighbouring structures. 201.1 if a neighbourhood plan does not specify any criteria, uses at least 2 of the following strategies: (i) building orientation, plan shape, massing and facade articulation to avoid tall and wide facades that face prevailing winds; 202.1 a podium and tower building form with a tower set back at least 10m from all streets above the podium level to deflect wind downdrafts from penetrating to street level (but a podium is not suitable for communal or private open space); 203.1 canopies and awnings to protect pedestrians; 204.1 trellis structures and a dense network of trees at ground or podium level. Note—This is demonstrated by submission of a wind impacts report from a suitably qualified professional.

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 PO39 AO39.1 Development provides car parking which: Development provides car parking which is: (a) minimises the impact on the quality of (a) not visible from the street, other public adjoining streetscapes or public spaces or the spaces or adjoining properties; or amenity of adjoining residents in terms of 210.1 located below ground or behind location, bulk, form and amenity impacts dwellings or active uses for the full street including noise, light or odours; frontage; 205.1 takes account of the following: 211.1 set back from front, rear and (i) the location of active frontages and side boundaries in compliance with a public spaces; neighbourhood plan or if no (ii) setback distances to mitigate impacts; neighbourhood plan applies or no requirements are specified in a 206.1 the proximity of dwelling neighbourhood plan, the requirements in houses or existing multiple dwellings on Table 9.3.3.3.D. adjoining sites; 207.1 the scale and detail of any Note—Car parking which extends 1m above ground level will be counted in the maximum height and will be subject to the parking structure walls when viewed relevant boundary setback requirements. from the street and adjoining properties; 208.1 the visual impact of open car AO39.2 parking and vehicle movement areas on Development does not provide a basement the street and adjoining properties; parking structure which: 209.1 convenient, safe and legible (a) extends above ground level forward of the vehicle access and car parking for users. main building line; 212.1 impacts on connections between the public footpath or space and the development. AO39.3 Development only provides car parking located above ground if: (a) it is fully integrated within the building design and is sleeved by development to required active frontages; or 213.1 it offers short-term car parking for customer, visitors or service providers, that is a portion of the total required car parking, and does not impact on active frontage requirements; or 214.1 it is located to the side or rear of the site away from the primary street or active frontage. Refer to Figure e. AO39.4 Development for a multistorey or podium car park: (a) is not located on the street frontage and is behind smaller uses to create an active frontage and avoid long blank walls particularly adjacent to a primary entrance from a key pedestrian connection; or 215.1 includes building facade details that extend to disguise the car parking floors; or 216.1 is screened to become a visually interesting structure. Refer to Figure f. AO39.5 Development ensures that visitor or customer car parking is: (a) clearly signposted; 217.1 lit at night; 218.1 not located behind a security barrier. Note—The detailed design is in accordance with the Transport, access, parking and servicing code and planning scheme policy. PO40 AO40.1 Development for a publicly accessible plaza, Development provides for pedestrian and cyclist arcade and pathway provided as part of movement adjoining and through a site at street development is easily accessed, attractive and level or at-grade. supports personal safety. Note—Grade-separated pedestrian movement systems, such Refer to Figure k. as an overhead bridge or underpass, are avoided because they are less attractive and safe for users. AO40.2 Development for a plaza, arcade, pathway and other external area in the site which is intended for public access at night complies with: (a) AS/NZS 1158.3.1:2005 Lighting for roads and public spaces Category P3; 219.1 AS 4282-1997 Control of the obtrusive effects of outdoor lighting PO41 AO41.1 Development for a plaza: Development for a plaza identified in a (a) promotes pedestrian and cyclist movement; neighbourhood plan, approved centre concept plan, structure plan or where proposed as a part of 220.1 links with transport development: interchanges; (a) is provided in the location identified; 221.1 provides opportunities for the flexible use of the space by the 223.1 is of a regular shape and has a community; minimum frontage to a road of 10m; 2 222.1 provides an edge which 224.1 has a minimum size of 400m ; contributes to the plaza’s character and 225.1 is integrated with surrounding activation. development; 226.1 has a minimum dimension of 20m; 227.1 is located at the level of the ground storey of adjoining buildings; 228.1 is suitable for pedestrian and cyclist access; 229.1 includes a minimum of 50% hard-paved area; 230.1 includes a minimum of 20% deep- planting area to accommodate subtropical shade trees; 231.1 is a minimum 75% open to the sky. AO41.2 Development ensures that a minimum of 50% of

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 the adjacent building frontages to a plaza contain active frontages and building entries. AO41.3 Development does not provide for a vehicle entry, driveway, car parking, bin storage or servicing in a plaza. AO41.4 Development does not provide for a mechanical ventilation outlet or vent on a frontage adjoining a plaza. AO41.5 Development for a plaza: (a) is publicly accessible during the hours of operation of the use; 232.1 provides equitable access to and movement in the plaza in accordance with AS 1428.1-2009 Design for access and mobility; 233.1 has a dominant ground level that is less than 1m above or below the dominant adjacent street level; 234.1 is designed such that the majority of the plaza space, that is an area which is more than 50%, is visible from the dominant adjacent public street. PO42 AO42 Development for an arcade: Development for an arcade identified in a (a) provides public access and connection to neighbourhood plan, approved centre concept facilitate direct, convenient, comfortable and plan, structure plan or where proposed as a part of safe access with centre or mixed use areas or development: developments to key destinations; (a) provides pedestrian access during hours of 235.1 has a strong street presence and operation of the use; clear entry; 239.1 integrates with adjoining 236.1 has an active frontage and use; buildings; 237.1 has high-quality finishes and 240.1 links established pedestrian materials; networks, parking and public transport facilities; 238.1 addresses public safety. 241.1 has a minimum corridor width Note—An arcade is a publicly accessible privately owned of 6m, including a minimum connection. unobstructed pavement width of 3m; 242.1 has an active use edge; 243.1 is finished with high-quality materials considering public safety; 244.1 is provided at-grade with an adjoining public area and connects safely without any lip or step; 245.1 incorporates crime prevention through environmental design principles to maximise safety; 246.1 has signage at each end identifying the connection provided; 247.1 is straight and allows for visual connection to the other end. Note—Crime prevention principles can be found in the Crime prevention through environmental design planning scheme policy.

Note—Development for cross block links is addressed in the Streetscape hierarchy overlay code. PO43 AO43 Development provides and maintains a Development for a pedestrian connection within continuous, accessible, attractive, direct, the site which is publicly accessible (privately convenient and legible connection and pathway owned): for pedestrians and cyclists. (a) is clearly delineated and separated from parking bays; 248.1 provides direct convenient connection to entries; 249.1 is suitable for all users; 250.1 is properly illuminated at all times; 251.1 is covered or shaded where open; 252.1 is finished in different materials or colour to parking bays; 253.1 has a width which complies with a neighbourhood plan, approved centre concept plan or structure plan or is otherwise a minimum of 3m wide; 254.1 includes a separate bikeway if appropriate; 255.1 is designed in compliance with the Infrastructure design planning scheme policy. PO44 AO44 Development for public toilets is located Development for a publicly accessible toilet: sensitively so that: (a) is located near spaces or pathways with high (a) the use is supported; pedestrian activity and use; 256.1 public surveillance is provided; 258.1 has amenity that is visible from 257.1 the development is not visually the spaces or pathways with high intrusive. pedestrian activity and use; 259.1 is not visually intrusive; 260.1 is accessed via a direct legible pathway that is consistently lit in compliance with AS/NZS 1158.3.1:2005 Lighting for roads and public spaces Category P3; 261.1 has high mounted vandal- resistant luminaires for external lighting, and lighting in compliance with AS 4282-1997 Control of the obtrusive effects of outdoor lighting, Table 2.1, Illuminance in the vertical plane, Curfewed hours. PO45 AO45 Development for pedestrian access and movement Development for mixed use restricts access from is defined and controlled to ensure privacy and the street or publicly accessible areas of the site to security. private residential dwellings or communal open

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 space. PO46 AO46.1 Development supports pedestrian movement and Development for fencing is not located between pedestrian access which is barrier free to a the front boundary and main building line. building entry and a publicly accessible space. Note—If residential development is located on the ground storey and includes fencing, it is provided in accordance with the Multiple dwelling code. AO46.2 Development for fencing on common side or rear boundaries to a public space is a maximum of: (a) 1.2m, where fence construction is solid or less than 50% transparent; 262.1 1.5m, where fence construction is at least 50% transparent. AO46.3 Development for a retaining wall is: (a) stepped to minimise impact on the streetscape and pedestrian environment; 263.1 a maximum of 0.6m in height if directly abutting the verge and footpath. PO47 AO47 Development for an ATM or vending machine is Development for an ATM or vending machine: located to avoid obstructing the footway with (a) is set back a minimum of 1.5m from street loitering queues, through their siting away from furniture, street trees and garden beds; drinking fountains, seating or public telephones. (b) includes a visually permeable barrier located in the development site to prevent queues forming across a footpath or pedestrian way. PO48 AO48.1 Development for a stand-alone shopping centre or Development involving a new premises or an a shop positively contributes to a neighbourhood extension of a stand-alone shopping centre or structure with built form and active frontage to the shop: street providing direct connection for pedestrians (a) is in compliance with a neighbourhood plan; into the centre or shop without the need to or navigate any surrounding car parking. 264.1 if no neighbourhood plan applies, or a neighbourhood plan does not specify, provides an active frontage – primary for a minimum of 1 street frontage. Refer to Figure g. AO48.2 Development for a stand-alone shopping centre or shop with more than 1 street frontage ensures that: (a) a primary frontage is treated as an active frontage – primary; 265.1 the extent of active frontage treatment on the other frontages is a minimum of 25%. AO48.3 Development for a stand-alone shopping centre or shop located on an arterial road, provides for: (a) a minimum of 25% active frontage connection to this street front; 266.1 a strong internal pedestrian oriented ‘street’ with an active frontage. PO49 AO49 Development within an existing traditional strip Development within an existing traditional strip centre or corridor: centre or corridor provides a streetscape which: (a) contributes to the existing character and (a) is in compliance with a neighbourhood plan; structure; or 267.1 provides a continuous 268.1 if no neighbourhood plan pedestrian environment at street level. applies or a neighbourhood plan does not specify requirements for a streetscape, ensures that the development: (i) has a minimum of 1 active frontage – primary; 269.1 is set back in keeping with existing adjoining uses; 270.1 locates large-format retail or employment uses at ground floor behind smaller uses and tenancies to the street; 271.1 is consistent in height with existing development; 272.1 maintains a consistent street edge with parapet height and awnings at the base of the building with upper levels set back from the front alignment. Refer to Figure h. PO50 AO50.1 Development contributes to the role of the street Development which requires an active frontage – or public space as the focus for vibrant primary, identified in a neighbourhood plan, commercial activity and community life and approved centre concept plan, structure plan, or as provides active frontages through: a part of the development provides: (a) intensive activation of the ground storey with (a) a continuous built form to the street at the highly active non-residential uses which nominated setback; encourage the greatest degree of pedestrian 278.1 a ground storey fully occupied activity and interaction; by highly active non-residential uses; 273.1 strong physical and visual 279.1 a 1st and 2nd storey featuring integration between the ground storey windows or balconies promoting and the adjoining verge or public space interaction with and surveillance of the to seamlessly integrate indoor and street; outdoor spaces; 280.1 awnings for the full building 274.1 building design which provides frontage; a visually interesting, interactive and 281.1 lighting of publicly accessible continuous built form and rhythm to the areas including the underside of street; awnings; 275.1 richly detailed, human-scaled 282.1 at least 1 pedestrian entry and and fine-grained building frontages; exit for every 10m of building frontage; 276.1 a safe, enjoyable and 283.1 a minimum of 50% transparent continuous pedestrian environment external wall materials up to a height of without obstruction or interruption from 2.5m above pavement level; vehicular crossovers and manoeuvring; 284.1 a minimum ground-storey 277.1 a subtropical urban design and height of 4.2m. built form which encourages outdoor lifestyles and engagement with the Note—Non-residential uses must be continuous along the public realm. active frontage – primary. Note—Highly active non-residential uses create the greatest Note—If a neighbourhood plan identifies an active frontage, but not whether it is primary or secondary, active frontage –

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 degree of pedestrian activity and interaction and are mostly primary criteria apply. accommodated in small individual tenancies with narrow AO50.2 building frontages, such as shops, restaurants and cafes. Development which requires an active frontage – secondary, identified in a neighbourhood plan, approved centre concept plan, structure plan, or as part of the development provides: (a) a continuous built form to the street at the nominated setback; 285.1 a ground storey substantially occupied by active non-residential uses; 286.1 a 1st and 2nd storey featuring windows and balconies promoting interaction with and surveillance of the street; 287.1 provides at least 1 pedestrian entry/exit for every 20m of building frontage; 288.1 a minimum 30% transparent external wall materials up to a height of 2.5m above pavement level; 289.1 a minimum ground-storey height of 4.2m. Note—Non-residential uses need not be continuous along an active frontage – secondary but should be located to activate critical locations such as intersections and pedestrian entries to buildings.

Note—If a neighbourhood plan identifies an active frontage, but not whether it is primary or secondary, active frontage – primary criteria apply. PO51 AO51.1 Development of vehicle access and parking does Development which requires an active frontage – not impact on an active frontage in a centres and primary, identified in a neighbourhood plan, mixed use area. approved centre concept plan, structure plan, or as part of the development, ensures that vehicle and service access is: (a) not located on this active frontage – primary; 290.1 from a secondary frontage or from an adjoining premises if a shared driveway and access arrangement is established. AO51.2 Development which requires an active frontage – primary or active frontage – secondary identified in a neighbourhood plan, approved centre concept plan, structure plan or as part of the development, ensures that parking is not located adjacent to the frontage or is not visible from the street. PO52 AO52 Development provides building entries that Development of foyer space on an active support active frontage outcomes. frontage: (a) occupies a minimal proportion and subordinate part of the building frontage; 291.1 is publicly accessible during normal business hours and visible from adjoining verges or public space; 292.1 contains activities and spaces such as reception desks, seating areas, cafes, shopfront galleries and display spaces that attract people. PO53 AO53 Development provides landscaping on site to: Development provides landscaping that: (a) contribute positively to the subtropical (a) integrates with site layout and building character, amenity and microclimate of the design at ground, podium, balcony and site and the centre or mixed use area; rooftop levels; 293.1 support the retention of existing 301.1 is sited to retain and protect significant vegetation and large existing significant vegetation; subtropical shade trees; 302.1 buffers adjoining residential 294.1 support the establishment of uses or areas, with advanced trees and a subtropical streets and planting; minimum of 2 tiers to achieve screening 295.1 contribute to site amenity for and visual softening; building occupants, users, residents and 303.1 supports building height adjoining residents; transitions, where required; 296.1 balance the bulk and scale of 304.1 is accessible for watering and the building and minimise impact to maintenance; adjoining residents, uses and streetscape; 305.1 screens or buffers driveways, 297.1 reduce the area of impervious service and loading areas, plant rooms or surfaces and support stormwater quality; other utilities; 298.1 reduce glare and manage heat; 306.1 allows for the overlooking of 299.1 contribute to the mitigation of the street and pedestrian entry areas from noise, air and visual impacts of major the building; transport infrastructure; 307.1 emphasises clear pedestrian 300.1 contribute to a safe and useable entry points. pedestrian environment. Note—No overall percentage of open space and landscaping is prescribed for non-residential development.

Note—This is demonstrated in a landscape concept plan.

Note—Landscape design incorporates planting in accordance with the Planting species planning scheme policy.

Note—The location, design and provision of communal and private open space for residential uses must be in compliance with the Multiple dwelling code. PO54 AO54.1 Development incorporates deep planting which: Development locates deep-planting areas: (a) supports the retention and protection of (a) to retain and protect existing significant existing significant vegetation and large vegetation and large subtropical shade trees; subtropical shade trees; 314.1 to buffer adjacent residential 308.1 provides for the establishment areas; of vegetation to contribute to the 315.1 to support building height landscape character of the centre or transitions, where required; mixed use area; 316.1 to provide an entry statement; 309.1 is grouped with deep-planting 317.1 to shade publicly accessible areas on adjacent sites to maximise areas, private outdoor and communal contiguous areas of deep planting; open space. 310.1 is open to the sky with access to AO54.2 light and rainfall and into the natural ground with no underground Development: development; (a) provides for a minimum 10% of the site area 311.1 is planted with large subtropical for deep planting;

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 tree species that at maturity are 318.1 ensures that each deep-planting complementary in scale and height to the area has a minimum area of 25m2 and a building form; minimum dimension of 4m in any 312.1 is capable and supported to direction. grow and at maturity provide effective AO54.3 shade or screening to buildings, outdoor Development provides deep-planting areas that spaces or adjoining uses; are: 313.1 balances hard-stand areas and (a) exclusively for landscaping; provides shade and informal recreation spaces that are directly accessible from 319.1 not containing vehicle residences, building tenancies or the manoeuvring areas, pedestrian paths, street frontage. surface structures or infrastructure, sub- surface structures or infrastructure; 320.1 able to accommodate trees planted in natural ground with no development underneath; 321.1 100% open to the sky; 322.1 able to be accessed for maintenance purposes. AO54.4 Development provides trees in deep-planting areas which: (a) are capable of growing to a minimum canopy diameter of 5m and/or a minimum height of 5m within 5 years of planting; 323.1 are subtropical tree species consistent with the Planting species planning scheme policy. Note—Tree species should be chosen to respond to particular site location or design needs. Where site circumstances permit, tree species that are complementary in scale and height to the building form should be selected.

Note—Tree height and canopy spread will be dependent on species. AO54.5 Development provides a minimum of 25% of all trees as advanced stock. PO55 AO55.1 Development for an open air car park is Development for an open air car park at or above landscaped to: ground level provides that setbacks are densely (a) contribute positively to the landscape planted with a minimum of 1.5m wide character of the centre or mixed use area; landscaping. 324.1 reinforce and support pedestrian Note—Front setback is to be treated to address streetscape movement; interface issues and requirements. 325.1 provide a comfortable AO55.2 environment for pedestrians; Development for a ground-level open-air car park 326.1 reduce glare and heat; is designed with trees planted: 327.1 reduce impervious areas; (a) in a minimum 5.2m x 2.4m landscaped area 328.1 establish shade cover within a between every 6 car parking spaces with a period of 5 years. permeable surface treatment either side of the landscape area; or 329.1 at 6m intervals in a minimum 2.5m-wide landscaped bed, swale or other water sensitive urban design device adjacent to parallel car parking spaces; 330.1 at a minimum rate of 1 shade tree for every 6 car parking spaces. AO55.3 Development ensures that trees planted in an open air car park area achieve a minimum 50% shade cover along internal pedestrian paths within 5 years of certification. Note—Further requirements are contained in the Landscape works code and the Planting species planning scheme policy. AO55.4 Development uses landscaping to delineate safe pedestrian movement through open-air car parks. PO56 AO56 Development which is not located on an active Development setback from the road, where not frontage provides landscaping on the street including an active frontage treatment or the part frontage to: of the frontage not treated as an active frontage, is (a) contribute to the centre or mixed use area or provided with: development's landscape character and the (a) a minimum of 2m wide landscaping with development of Brisbane's subtropical advanced trees and low-level planting along streetscapes and public spaces; the full street or public space frontage or 331.1 provide shade and pedestrian balance part, excluding any driveway comfort and visual amenity; crossover and pedestrian access; or 332.1 contribute to the subtropical 335.1 a minimum of 3m wide character of the streetscape and public landscaping with advanced trees and realm; low-level planting, to establish a positive landscaped street edge where a service 333.1 not impede the establishment of station or outdoor sales use. active frontages where required; 334.1 maintain views from the street Note—It is envisaged that landscaping will be primarily located on frontages to arterial roads that are not suitable for to the building and frontage and consider active frontages. personal safety. PO57 AO57 Development for a building must not incorporate Development ensures that any reflective glass any type of glass or other surface likely to reflect material has: specular rays that could create undue nuisance, (a) a level of light reflectivity not greater than discomfort or hazard to the surrounding locality. 20%; 336.1 a level of heat transmission not less than 20%. PO58 AO58 Development minimises direct overlooking No acceptable outcome is prescribed. between buildings and to adjoining residential Note—Screening and fencing for a residential use is designed uses not located within the centre or mixed use in accordance with the Multiple dwelling code. area through site planning, building design, screening and landscaping. PO59 AO59 Development for residential uses in a zone in the No acceptable outcome is prescribed. centre zones category or the Mixed use zone Note—Screening and fencing for a residential use is designed maximises privacy and amenity for residents, in accordance with the Multiple dwelling code. taking into consideration the mix of uses within the area. Note—Residential development in a zone in the centre zones category or the Mixed use zone is not afforded the same level of visual privacy or amenity as within a residential area.

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 PO60 AO60.1 Development of garages, driveways and parking Development for a car park: structures minimise impacts on the amenity of (a) provides a 2m-high acoustic fence and a neighbouring dwellings. landscaped area 1.5m wide where located adjacent to a neighbouring dwelling; 337.1 is acoustically screened where the car park is used at night and where located adjacent to a neighbouring dwelling. AO60.2 Development for a driveway or vehicle movement area is screened by a 2m-high acoustic fence along the side or rear boundary if located adjacent to a residential dwelling. PO61 AO61.1 Development provides refuse and recycling Development is designed and constructed to collection and storage facilities that: ensure refuse and recycling collection and storage (a) are located conveniently in an unobtrusive facilities comply with the Refuse planning scheme dedicated storage room or separate screened policy. structure; AO61.2 338.1 are located and managed so that Development is designed and constructed to adverse impacts on building occupants, ensure refuse and recycling collection and storage neighbouring properties and the public facilities do not have any odour, noise or visual realm are minimised; impacts which are detectable and disturbing at the 339.1 provide for refuse and recycling site or adjoining sites. including source separation; Note—Refer to the Refuse planning scheme policy for further 340.1 are of a design which allows guidance. low-frequency service collection; 341.1 minimise ongoing building management cost for occupants. PO62 AO62 Development creates a safe environment by Development incorporates the key elements of incorporating the key elements of crime crime prevention through environmental design in prevention through environmental design. its layout, building or structure design and landscaping by: (a) facilitating casual surveillance opportunities and including good sightlines to publicly accessible areas such as car parks, pathways, public toilets and communal areas; 342.1 defining different uses and ownerships through design and restricting access from non-residential uses into private residential dwellings; 343.1 promoting safety and minimising opportunities for graffiti and vandalism through exterior building design and orientation of buildings and use of active frontages; 344.1 ensuring publicly accessible areas such as car parks, pathways, public toilets, communal areas are well lit; 345.1 including way-finding cues; 346.1 minimising predictable routes and entrapment locations near public spaces such as car parks, public toilets, ATMs, communal areas. Note—For guidance in achieving the key elements of crime prevention through environmental design refer to the Crime prevention through environmental design planning scheme policy. PO63 AO63 Development minimises the potential for graffiti Development design and landscaping incorporates and vandalism through appropriate design and graffiti and vandalism prevention techniques landscaping which controls access, reduces which: canvas and allows for easy maintenance selection. (a) deny access to potential canvas using access control techniques; 347.1 reduce potential canvases using canvas-reduction techniques; 348.1 ensure graffiti can be readily and quickly removed through easy maintenance selection techniques. Note—For guidance on graffiti and vandalism prevention techniques refer to the Graffiti prevention planning scheme policy. PO64 AO64 Development does not adversely impact the Development demonstrates that it will not result structural integrity or ongoing operation and in any impact on existing or planned sub-surface maintenance of sub-surface transport transport infrastructure through the submission of infrastructure which is an existing or endorsed an engineering and geological report and proposed tunnel. certification or consent provided by the relevant infrastructure owner. If identified in a neighbourhood plan PO65 AO65.1 Development minimises visual impacts to view Development ensures building placement and corridors of local significance and enhances design does not impact on a view corridor opportunities for observation of key vistas and identified in a neighbourhood plan. views from identified view points. Note—A neighbourhood plan may identify view corridors and may or may not identify any specific view points from which they are observed. AO65.2 Development creates opportunities for views and vistas from a view point identified in a neighbourhood plan. Note—A neighbourhood plan may identify view points and may or may not identify any specific view corridor that they observe. PO66 AO66.1 Development on a significant corner site provides Development is designed to emphasise the corner a prominent visual reference and contribution to setting of a significant corner site identified in a the neighbourhood’s public realm by: neighbourhood plan and provides: (a) accommodating high levels of pedestrian (a) building entries on both street frontages; movement at the corner and enhancing the 354.1 a single main entry at the pedestrian experience; corner. 349.1 emphasising the corner setting AO66.2 through building form, expression, silhouette, scale, materials and Development provides a corner land dedication on a significant comer site identified in a landscaping; neighbourhood plan, adjacent to the existing 350.1 reinforcing a sense of arrival to verge area which:

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 the neighbourhood plan area, precinct or (a) is configured and provided in the form sub-precinct through marking a node, an identified in Figure i or Figure j and intersection or connection point in the dimensions identified in the neighbourhood neighbourhood; plan; 351.1 respecting the prominence of (b) accommodates a deep-planted large feature any adjoining or nearby heritage places, tree in compliance with the road corridor traditional character buildings or local design section of the Infrastructure design landmarks; planning scheme policy; 352.1 if a corner land dedication is (c) is embellished in compliance with the road required: corridor design section of the Infrastructure (i) accommodating a deep-planted feature design planning scheme policy. tree within the dedication area; Note—A neighbourhood plan may indicate if a corner land 353.1 providing a building envelope dedication is to be truncated or inverted. If the configuration which acknowledges and respects the is not specified, a truncated land dedication is to be provided presence of the large feature tree canopy. where the building or podium is 2 storeys or fewer. Where an inverted corner land dedication is provided, the building Note—A neighbourhood plan will indicate whether or not a design accommodates the feature tree canopy at maturity. land dedication is required. AO66.3 Development ensures that any part of the building including the basement but excluding awnings is outside the corner land dedication area. Note—A neighbourhood plan may indicate if a building is able to volumetrically extend into the corner land dedication area. PO67 AO67.1 Development on a landmark site provides a Development: prominent visual reference and contribution to the (a) emphasises a landmark site identified in a city’s public realm by: neighbourhood plan and its setting; (a) exhibiting subtropical architectural 361.1 addresses all elevations, with excellence through design, treatment and front, side and rear facades all displaying articulation; a high level of modulation and 355.1 defining the site and its setting articulation; through building form, expression, 362.1 both vertically and horizontally silhouette, scale, materials and articulates building form and mass with landscaping; proportions compatible with the height, 356.1 reinforcing a sense of arrival to scale and setting of the building; the neighbourhood plan area, precinct or 363.1 provides an interesting and sub-precinct through marking a node, an varied skyline and silhouette; intersection or major connection point in 364.1 uses high-quality and durable the city; materials and finishes; 357.1 respecting the prominence of 365.1 integrates landscaping, building any adjoining or nearby heritage place or entries and the public realm at the local landmark; ground plane. 358.1 if a corner land dedication is required: Note—The Council’s Independent design advisory panel may be invited to provide advice on developments in accordance (i) accommodating a deep-planted large with the provisions of the Independent design advisory panel feature tree within the dedication area; planning scheme policy. 359.1 providing a building envelope AO67.2 that acknowledges and respects the presence of the large feature tree canopy; Development provides a corner land dedication adjacent to the existing verge area which: 360.1 accommodating high levels of pedestrian movement and enhancing the (a) is configured and provided in the form pedestrian experience. identified in Figure i or Figure j; 366.1 complies with any dimensions Note—A neighbourhood plan may indicate whether or not a land dedication is required. identified in a neighbourhood plan; 367.1 accommodates a deep-planted feature tree in compliance with the Infrastructure design planning scheme policy; 368.1 is embellished in compliance with the Infrastructure design planning scheme policy. Note—A neighbourhood plan may indicate if a corner land dedication is to be truncated or inverted. If the configuration is not specified, a truncated land dedication is to be provided where the building or podium is 2 storeys or fewer. Where an inverted corner land dedication is provided, the building design accommodates the feature tree canopy at maturity. PO68 AO68 Development of a landscape buffer is provided in Development provides a landscape buffer along particular locations to facilitate: the boundaries of the site identified in a (a) visual privacy to and between sites; neighbourhood plan, which consists of: 369.1 visual amenity; (a) 3 tiers of planting; 370.1 shading and occupant amenity; 372.1 a combination of rounded canopy and columnar trees; 371.1 local habitat. 373.1 a maximum spacing of 1 tree for every 6m; 374.1 trees capable of growing to a minimum height of 8m; 375.1 shrubs and ground covers. Note—A neighbourhood plan will indicate the boundaries where the landscape buffer is to be provided and the dimensions of the area. Table 9.3.3.3.B—Building heights Zone Zone precinct Maximum building height (storeys) Major centre Not applicable 10 District centre District 4 Corridor 5 Neighbourhood centre Not applicable 3 Mixed use Inner-city 5 Centre frame 5 Corridor 4

Note—Building height is measured in storeys unless a neighbourhood plan or overlay identifies a specific height in metres. Table 9.3.3.3.C—Boundary setback requirements Height of Land use Minimum boundary setback (m) building/wall Front/street (m) Side (m) Rear (m) Active Arterial Adjacent frontage road or if to lower (except setback is intensity on required residential arterial for site road) use or pedestria n movement Ground-floor Non- 0 3 3 0 if blank 0

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 storey and to residential 2m 4.5m otherwise Residential NA 6 6 to wall 1.5 4.5 Podium or up Non- 0 3 4 to 0 if blank 6 to 5 storeys residential/ balcony/ 3m if non- Residential 6 to wall habitable 5m if habitable or to balconies Tower – Non- 3 6 8 6 10 Above 5 residential storeys to 15 Residential 6 8 6 to 6 10 storeys balcony/ 8 to wall

Notes—

For development located on a site with 2 or more street frontages, a primary street frontage will be nominated.

For a site with 2 or more street frontages, all common boundaries with adjoining lots are considered side boundaries.

Building height transition and building separation requirements to a residential development may vary boundary setback requirements.

Car parking is to comply with the siting requirements in Table 9.3.3.3.D.

Roofing of terrace areas created on car parking structures is to comply with boundary setback requirements for balconies specified in Table 9.3.3.3.C.

Front boundary setbacks are generally not influenced by building separation requirements.

Table 9.3.3.3.D—Siting requirements for car parking Height of wall or parking Minimum boundary setback to parking or parking Car parking configuration structure (m) Front/ street Side/rear – If a Side/rear – If zone in the not a zone in centre zones the centre category or the zones category Mixed use zone or the Mixed use zone and adjoining a residential zone Below ground level or above ground level 0 if below 0 0 by less than 1m and enclosed ground level 4 if above ground by less than 1m Above ground level by less than 4.5m and 6 0 1.5 enclosed Above ground level between 4.5m and 2 6 0 3 storeys or 7.5m and enclosed 3 if partially open Above ground level between 7.5m and 3 6 0 6 storeys or 10.5 m and enclosed 6 if partially open Above ground level by greater than 3 No acceptable outcome is prescribed storeys and 10.5m Above ground level by less than 4.2m and 2 1.5 2 open

Notes—

Height is to the highest point of the car parking structure including any roofing or shelter to the car parking area, measured above ground level at any point on the site.

The height also includes fences, balustrades or podium planters located above the enclosed car parking structure.

Where a terrace area is created on a car parking structure, any roofing is to comply with the boundary setback requirements for a balcony in Table 9.3.3.3.C.

A number of car parking configurations and wall heights relative to ground level may occur on a site. The impact of refuse collection is to be considered in the design of car parking if refuse storage is located in a parking area or structure.

Table 9.3.3.3.E—Building separation requirements Building height Minimum building separation (m) (storeys and m) Facing habitable Habitable rooms or Non-habitable rooms rooms with windows balconies facing non- with windows or or balconies habitable rooms with blank walls windows or blank walls Ground 3 1.5 0 if blank with no to 4.5m windows 1.5 if non-habitable with windows 2 storey 9 6 0 if blank with no to 7.5m windows 3 if non-habitable with windows 3 to 5 storeys 12 9 0 if blank with no windows 6 if non-habitable with windows 6 to 8 storeys 18 12 9 9+ storeys 24 18 12 Podium or roof terraces Located to achieve separation in accordance with the relative level of the podium or roof location as above, along with design elements to ensure the privacy and amenity of residents within the site and on adjoining or adjacent sites. Table 9.3.3.3.F—Noise (planning) criteria Criteria location Intrusive noise criteria Acoustic amenity criteria

Day, evening and night Day, evening and night LAeq,adj,T are LAeq,adj,T are not greater not greater than the values in the than the RBL plus the columns below for the relevant value in this column for criteria location, where T equals: the relevant criteria day – 11hr location, where T equals: day – 11hr evening – 4hr

evening – 4hr night – 9hr

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 night – 9hr

Day Evening Night

Low density residential zone 3dB(A) 55dB(A) 45dB(A) 40dB(A) boundary Low–medium density 3dB(A) 55dB(A) 45dB(A) 40dB(A) residential zone boundary Medium density residential 3dB(A) 55dB(A) 50dB(A) 45dB(A) zone boundary High density residential zone 3dB(A) 55dB(A) 50dB(A) 50dB(A) boundary Character residential zone 3dB(A) 50dB(A) 45dB(A) 40dB(A) boundary Tourist accommodation zone 3dB(A) 55dB(A) 50dB(A) 50dB(A) boundary At sensitive use in the Principal 5dB(A) 60dB(A) 55dB(A) 50dB(A) centre zone At a sensitive use in the Major 5dB(A) 60dB(A) 55dB(A) 50dB(A) centre zone At a sensitive use in the 5dB(A) 60dB(A) 55dB(A) 50dB(A) District centre zone At a sensitive use in the 5dB(A) 55dB(A) 50dB(A) 50dB(A) Neighbourhood centre zone At a sensitive use in the 5dB(A) 55dB(A) 50dB(A) 50dB(A) Specialised centre zone Emerging community zone 5dB(A) 55dB(A) 50dB(A) 45dB(A) boundary Environmental management 0dB(A) 40dB(A) 40dB(A) 40dB(A) zone boundary Conservation zone boundary 0dB(A) 40dB(A) 40dB(A) 40dB(A) At a sensitive use in the Mixed 5dB(A) 60dB(A) 55dB(A) 50dB(A) use zone At a sensitive use in the Rural 5dB(A) 55dB(A) 50dB(A) 45dB(A) zone At a sensitive use in the Rural 5dB(A) 50dB(A) 45dB(A) 40dB(A) residential zone At a sensitive use in the 5dB(A) 55dB(A) 45dB(A) 40dB(A) Township zone

Notes—

LAeq,adj,T: The adjusted A-weighted equivalent continuous sound pressure level of the development during the time period T, where T is an 11-hour day (7am–6pm), 4-hour evening (6pm–10pm) and 9-hour night (10pm–7am), determined in accordance with the methodology in the Noise impact assessment planning scheme policy.

RBL: Rating background level determined in accordance with the methodology in the Noise impact assessment planning scheme policy. dB(A): A-weighted decibels

Table 9.3.3.3.G—Low frequency noise criteria Criteria location Day LCeq,adj,11hr is Evening LCeq,adj,4hr Night LCeq,adj,9hr is not greater than is not greater than not greater than the following the following the following values at the values at the values at the relevant criteria relevant criteria relevant criteria location location location Low density residential zone 65dB(C) 65dB(C) 60dB(C) boundary Low–medium density residential 65dB(C) 65dB(C) 60dB(C) zone boundary Medium density residential zone 65dB(C) 65dB(C) 60dB(C) boundary High density residential zone 70dB(C) 65dB(C) 65dB(C) boundary Character residential zone boundary 65dB(C) 65dB(C) 60dB(C) Tourist accommodation zone 70dB(C) 65dB(C) 65dB(C) boundary At a sensitive use in the Principal 75dB(C) 75dB(C) 70dB(C) centre zone At a sensitive use in the Major 75dB(C) 75dB(C) 70dB(C) centre zone At a sensitive use in the District 70dB(C) 65dB(C) 65dB(C) centre zone At a sensitive use in the 70dB(C) 65dB(C) 65dB(C) Neighbourhood centre zone At a sensitive use in the Specialised 75dB(C) 75dB(C) 70dB(C) centre zone Emerging community zone 65dB(C) 65dB(C) 60dB(C) boundary Environmental management zone 65dB(C) 65dB(C) 65dB(C) boundary Conservation zone boundary 65dB(C) 65dB(C) 65dB(C) At a sensitive use in the Mixed use 75dB(C) 75dB(C) 70dB(C) zone At a sensitive use in the Rural zone 70dB(C) 65dB(C) 65dB(C) At a sensitive use in the Rural 65dB(C) 65dB(C) 60dB(C) residential zone At a sensitive use in the Township 70dB(C) 65dB(C) 65dB(C) zone

Note—

LCeq,adj,T: The adjusted C-weighted equivalent continuous sound pressure level of the development during the time period T, where T is an 11-hour day (7am–6pm), 4-hour evening (6pm–10pm) and 9-hour night (10pm–7am), determined in accordance with the methodology in the Noise impact assessment planning scheme policy. dB(C): C-weighted decibels

Table 9.3.3.3.H—Night-time noise criteria Criteria location Where the existing Average of the highest The absolute highest LAeq,9hr night at the 15 single LAmax events single LAmax event

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 criteria location is: over a given night over a given night (10pm–7am) period is (10pm–7am) period is not greater than the not greater than the following values at the following values at the relevant criteria relevant criteria location location At the zone boundary <45dB(A) 50dB(A) 55dB(A) of a: Low density residential zone; Low–medium density residential 45 to 60dB(A) LAeq,9hr night + 5 dB(A) LAeq,9hr night + 10dB(A) zone; Medium density residential zone; High density residential zone; >60dB(A) 65dB(A) 70dB(A) Character residential zone; Tourist accommodation zone; Emerging community zone. External to a sensitive Not applicable 65dB(A) 70dB(A) use located in a: Principal centre zone; Major centre zone; District centre zone; Neighbourhood centre zone; Specialised centre zone; Mixed use zone; Rural zone; Rural residential zone; Township zone.

Notes—

LAmax: The A-weighted maximum sound pressure level determined in accordance with the methodology in the Noise impact assessment planning scheme policy.

LAeq,9hr: The A-weighted equivalent continuous sound pressure level of the development during the night- time period 10pm to 7am, determined in accordance with the methodology in the Noise impact assessment planning scheme policy. Night: 10pm to 7am dB(A): A-weighted decibels

Table 9.3.3.3.I—Air quality planning criteria Pollutant Averaging Health outcome Criteria Criteria time protected including including background background (µg/m3) (ppm) Nitrogen dioxide 1 hour Health and wellbeing 250 0.12 Annual Health and wellbeing 62 0.03 Sulfur dioxide 1 hour Health and wellbeing 570 0.2 24 hours Health and wellbeing 230 0.08 Annual Health and wellbeing 57 0.02 Particulate matter (PM) as Annual Health and wellbeing 90 - total suspended particulates (TSP)

PM less than 10 µm (PM10) 24 hours Health and wellbeing 50 -

PM less than 2.5 µm (PM2.5) 24 hours Health and wellbeing 25 - Annual Health and wellbeing 8 - Carbon monoxide 8 hours Health and wellbeing 11,000 9 Dust deposition as insoluble Annual Protecting aesthetic 4g/m2/month - solids environment 1,1,1-trichloroethane (methyl 1 hour Health and wellbeing 12,500 2.3 chloroform) 1,1,2-trichloroethane 1 hour Health and wellbeing 1,000 0.18 1,1-biphenyl 1 hour Health and wellbeing 24 0.0037 1,2-dichloroethane 24 hours Health and wellbeing 750 0.17 1,3-butadiene Annual Health and wellbeing 2.4 0.001 Acetaldehyde 1 hour Odour 42 0.023 Acetic acid 1 hour Odour 270 0.11 Acetone 1 hour Health and wellbeing 22,000 9.2 Acrolein 1 hour USEPA extremely toxic 0.42 0.00018 Acrylonitrile 1 hour USEPA Group B1 8 0.0037 carcinogen (probable human carcinogen) Alpha chlorinated toluenes 1 hour IARC Group 1 9 0.0018 and benzoyl chloride carcinogen (known human carcinogen) Ammonia 1 hour Health and wellbeing 330 0.46 Antimony and compounds 1 hour Health and wellbeing 9 - Arsenic and compounds (as 1 hour IARC Group 1 0.09 - total metal content in PM10) carcinogen (known human carcinogen) Annual Health and wellbeing 6ng/m3 -

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 Benzene Annual Health and wellbeing 10 0.003 Benzo(a)pyrene (as marker Annual Health and wellbeing 0.3ng/m3 - for PAH) Beryllium and compounds 1 hour IARC Group 1 0.004 - carcinogen (known human carcinogen) Bromochloromethane 1 hour Health and wellbeing 19,000 3.7 Bromoform 1 hour Health and wellbeing 90 0.009 (tribromomethane) Bromotrifluoromethane 1 hour Health and wellbeing 112000 18 Butyl acrylate 1 hour Odour 100 0.019 Butyl mercaptan 1 hour Odour 7 0.002 Cadmium and compounds (as Annual Health and wellbeing 5ng/m3 - total metal content in PM10) Carbon disulfide 1 hour Odour 183 0.0055 24 hours Health and wellbeing 110 0.032 Chlorine 1 hour Health and wellbeing 50 0.018 Chlorine dioxide 1 hour Health and wellbeing 5.1 0.0018 Chlorobenzene 1 hour Odour 100 0.023 Chloroform 1 hour Health and wellbeing 900 0.18 Chromium III compounds 1 hour Health and wellbeing 9 - Chromium VI compounds 1 hour IARC Group 1 0.09 - carcinogen (known human carcinogen) Copper dusts and mists 1 hour Health and wellbeing 18 - Copper fumes 1 hour Health and wellbeing 3.7 - Cumene (isopropyl benzene) 1 hour Odour 21 0.004 Cyanide (as CN) 1 hour Health and wellbeing 90 - Cyclohexane 1 hour Health and wellbeing 19,000 5 Cyclohexanone 1 hour Odour 260 0.07 Diacetone alcohol 1 hour Odour 700 0.15 Dichloromethane (methylene 24 hours Health and wellbeing 3,200 0.85 chloride) 7 days Health and wellbeing 480 0.13 Diethylamine 1 hour Odour 30 0.01 Dimethylamine 1 hour Odour 9 0.0052 Dioxins and furans (as TCDD 1 hour IARC Group 1 0.000002 - TEF) carcinogen (known human carcinogen) Diphenyl ether 1 hour Odour 80 0.01 Ethanol 1 hour Odour 2,100 1.1 Ethyl acetate 1 hour Odour 12,100 3.5 Ethyl acrylate 1 hour Odour 0.4 0.0001 Ethyl butyl ketone 1 hour Health and wellbeing 4,200 0.9 Ethyl chloride (chloroethane) 1 hour Health and wellbeing 48,000 18 Ethylbenzene 1 hour Health and wellbeing 8,000 1.8 Ethylene oxide 1 hour IARC Group 1 3.3 0.0018 carcinogen (known human carcinogen) Formaldehyde 1 hour Protecting aesthetic 96 0.07 environment 24 hours Health and wellbeing 54 0.04 Hydrogen chloride 1 hour Health and wellbeing 140 0.09 Hydrogen cyanide 1 hour USEPA extremely toxic 200 0.18 Hydrogen sulfide 24 hours Health and wellbeing 160 0.11 1 hour Odour 6.5 0.0043 Lead and compounds (as total Annual Health and wellbeing 0.5 - metal content in total suspended particulates) Magnesium oxide fumes 1 hour Health and wellbeing 180 - Manganese and compounds Annual Health and wellbeing 0.16 - (as total metal content in PM10) MDI (diphenylmethane 1 hour USEPA extremely toxic 0.04 - diisocyanate) Mercury inorganic 1 hour Health and wellbeing 1.8 - Annual Health and wellbeing 1.1 - Mercury organic 1 hour Health and wellbeing 0.18 - Methanol 1 hour Odour 3000 2.4 Methyl ethyl ketone 1 hour Odour 3200 1.1 Methyl isobutyl ketone 1 hour Odour 230 0.05 Methyl mercaptan 1 hour Odour 0.46 0.00023 Methyl methacrylate 1 hour Odour 120 0.027 Methyl styrene 1 hour Odour 140 0.029 Methylamine 1 hour Odour 2.7 0.0023 n-Butanol 1 hour Odour 500 0.16 n-Butyl acetate 1 hour Odour 1,020 0.21 n-Hexane 1 hour Health and wellbeing 3,200 0.9 Nickel and compounds (as Annual Health and wellbeing 0.02 - total metal content in PM10) Nitric acid 1 hour Health and wellbeing 90 0.037 Nitrobenzene 1 hour Odour 2.6 0.00052 n-Propanol 1 hour Odour 41 0.016 Pentachlorophenol 1 hour USEPA extremely toxic 0.9 -

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015 Phenol 1 hour Odour 20 0.0052 Phosgene 1 hour USEPA extremely toxic 7 0.0018 Phosphine 1 hour Odour 3.1 0.0023 Propylene oxide 1 hour USEPA Group B1 90 0.037 carcinogen (probable human carcinogen) Pyridine 1 hour Odour 7 0.0023 Styrene 1 hour Odour 65 0.014 7 days Health and wellbeing 280 0.06 Sulfate 24 hours Health and wellbeing 27 - Sulfuric acid 1 hour Health and wellbeing 18 - TDI (toluene-2,4- 1 hour USEPA extremely toxic 0.04 - diisocyanate; toluene-2,6- diisocyanate) Tetrachloroethylene 1 hour Odour 7,487 1.01 (perchloroethylene) Annual Health and wellbeing 270 0.036 Toluene 1 hour Odour 958 0.23 24 hours Health and wellbeing 4,100 1 Annual Health and wellbeing 410 0.1 Trichloroethylene 1 hour IARC Group 2A 500 0.09 carcinogen (probable human carcinogen) Triethylamine 1 hour Odour 200 0.05 Vanadium and compounds 24 hours Health and wellbeing 1.1 - (as total metal content in PM10) Vinyl chloride monomer 24 hours Health and wellbeing 28 0.01 Vinyl toluene 1 hour Health and wellbeing 4,400 0.9 Welding fumes (total 1 hour Health and wellbeing 90 - particulate) Xylenes (as a total of ortho, 24 hours Health and wellbeing 1,200 0.25 meta and para isomers) Annual Health and wellbeing 950 0.2 Zinc chloride fumes 1 hour Health and wellbeing 18 - Zinc oxide fumes 1 hour Health and wellbeing 90 -

Note—

Criteria that are stated in µg/m3 are to be referenced to 0°C.

Criteria that are stated in ppm are to be expressed as volume/volume.

Averaging times of 1 hour or less are to be presented using the 99.9th percentile concentration of the total site impact from dispersion modelling and background concentration for all pollutants in the above table, or the maximum concentration from dispersion modelling if no background concentration is available. Averaging times of greater than 1 hour are to be presented using the maximum concentration of the total site impact from dispersion modelling and background concentration.

Dust deposition is the maximum allowable level from new and existing sources, calculated from annualised modelling data.

Polycyclic aromatic compounds (PAH) are assessed as benzo(a)pyrene equivalent using potency equivalency factors as listed in the Air quality planning scheme policy.

Dioxins and furans are assessed as 2,3,7,8-tetrachlorodibenzodioxin equivalent (TCDD) using toxic equivalency factors (TEF) as listed in the Air quality planning scheme policy. ng – nanograms

Table 9.3.3.3.J—Odour criteria Pollutant Averaging time Health outcome Criteria (odour units – OU) protected Odour 1 hour Odour 0.5 OU for tall stacks Odour 1 hour Odour 2.5 OU for ground-level and wake- affected plumes from short stacks

Note—Odour criteria are to be evaluated using the 99.5th percentile concentration from dispersion modelling.

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015

Part 9 – Development Codes (Centre or Mixed Use) Effective 4 September 2015