Engine Company Performance Standard

Total Page:16

File Type:pdf, Size:1020Kb

Engine Company Performance Standard

TABLE OF CONTENTS

EVOLUTION # 01A. Single Crosslay 02A. Single Crosslay with a back-up line 03A. Simulated FDC 04A. Single or Single Crosslay with a backup line and water supply 05A. Progressive Hoselay 06A. Extended Driveway Fire Attack 07A. Master Stream with water supply 08A. Structure Defense with rapid abandonment 09A. Steep roof ventilation 10A. Ground Monitor with water supply 11A. Mobile Attack with Type 3 or Type 5/6 engine 12A. Type 5/6 water supply 13A. 2½” Hose for fire attack with a water supply 14A. 2nd Story fire attack entrance is from the exterior using a ground ladder 15A. Search and Rescue 16A 17A. Piercing Nozzle Set-up 18A. Fire Attack using a Reverse Lay 19A. Fire Attack with E231 and a water supply. Company officers discretion if forward or

Reverse lay 20A Fire Attack Using Engine 231, With a Water Supply Established By a Second Engine 21A. Strike team readiness and response type 1, 2, 3, 5, & 6. CORDELIA FIRE PROTECTION DISTRICT ENGINE COMPANY PERFORMANCE STANDARD

ENGINE COMPANY PERFORMANCE STANDARD #12A

TYPE 5/6 WATER SUPPLY

OBJECTIVE: Operator will complete the necessary tasks to spot the engine, establish a supply from draft and begin filling the water tank.

CONDITIONS: Operator in driver’s seat and wearing full wildland PPE

STANDARDS: This Company Standard is timed from the point at which the OPERATOR leaves the engine and ends when draft has been obtained. All tasks must be completed in a continuous and deliberate manor

1. Spots the engine proper distance from body of water. 2. Place the transmission in park. 3. Sets parking brake. 4. Engage high idol switch. 5. Places wheel chocks. 6. Retrieves and couples hard suction hose together along with strainer 7. Utility rope (Optional) attached to strainer basket and each section of suction hose. Rope secured to apparatus or other object. 8. Connects suction hose to pump suction inlet and places opposite end into the body of water 9. Closes tank valve. 10. Closes recirculating and educator flush valves. (If applicable) 11. Sets transfer valve to capacity. 12. Opens inlet valve and operates primer. 13. Achieves a prime. 14. Opens tank fill valve slowly. 15. All actions done in a smooth and deliberate motion without running. TIME STOPS ONCE A PRIME HAS BEEN ESTABLISHED AND THE BOOSTER TANK HAS STARTED TO FILL. 16. Fill the tank of the Type 5/6 17. Pump a simple hoselay of 1½” hose without losing a prime.

TIME ALLOTMENT: 4 minutes 15 seconds

TIMING STARTS: On the command: “Begin the Evolution”

TIMING STOPS: The standard is completed when the operator indicates that he/she believes that all components have been safely met and states “done” to the proctor”. ENGINE COMPANY PERFORMANCE STANDARD #21A

Team Readiness and Response Type 1, 2, 3, 4, 5/6

OBJECTIVE: To quickly place any of the Type 1, 2. 3, 5/6 engines in preparation for an out assignment. Remove and add/ or replace the necessary equipment to respond for either an immediate need out of county or planned need out of county response in a timely manner.

CONDITIONS: Crew will be in the station performing regular assigned duties

STANDARDS: This Company Standard is timed from the point at which the proctor gives the The company officer the assignment.

PLEASE SEE PAGE 2 OF COMPNAY EVOLUTION 21A FOR TASKS TO BE PERFORMED DURING THIS EVOLUTION

TIME ALLOTMENT: 4 minutes

TIMING STARTS: On the command: “Begin the Evolution”

TIMING STOPS: The standard is completed when company officer indicates that the apparatus is Ready for response. CORDELIA FIRE PROTECTION DISTRICT ENGINE COMPANY PERFORMANCE STANDARD

ENGINE COMPANY PERFORMANCE STANDARD #21A cont.

Team Readiness and Response Type 1, 2, 3, 4, 5/6

Type 2 & 3 Type 5/6 Engines (E231) (B-31) & (B-29)

Cots (4) Secure Strike Team Box To Apparatus

Sleeping Bags (4) Cots (4)

MRE's/ Snack Box Sleeping Bags (4)

Cooler W/ Ice and Water MRE's/ Snack Box

3 Hose Packs W/ 200' Of Cotton Hose/ Cooler W/ Ice and Water Remove the Synthetic Hose Packs

Remove Synthetic Hose Packs and Replace Strike Team Binder W/FC42 with Cotton Hose And ICS Form 214 Strike Team Binder W/ FC 42 and ICS Form BK Radios W/ Spare Batteries (4) 214

Map Books BK Radios W/ Spare Batteries (4)

Gas Card/CFD Card or Cash Map books

Gas card/CFD card or cash

REMOVE

Extrication Equipment

Narcotics if not ALS and a medic is one duty

PPV fan if on the apparatus