Data Element Number: CPR.01
Total Page:16
File Type:pdf, Size:1020Kb
CPR Metrics and Time Measurement Data Dictionary
CPR Metrics
Data Element Number: CPR.01
Data Element Name: Average CPR Rate/Min
National Element: No
State Element: No
Definition: The average rate of CPR compressions per minute for the selected time interval of the cardiac arrest.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest
Attribute: Integer Min: 0 Max: 200
Comments:
March 3, 2014 Page 1 of 19 Data Element Number: CPR.02
Data Element Name: Percentage of CPR Compressions Within 100- 120 Compressions per Minute
National Element: No
State Element: No
Definition: The percentage of CPR compressions within 100-120 compressions per minute calculated based on each compression-to-compression interval.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest
Attribute: Integer Min: 0 Max: 100
Comments:
March 3, 2014 Page 2 of 19 CPR Metrics and Time Measurement Data Dictionary
Data Element Number: CPR.03
Data Element Name: Average Chest Compression Depth
National Element: No
State Element: No
Definition: The average (mean) depth of the CPR chest compressions for the cardiac arrest period.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest
Attribute: Decimal Total Digits: 2 Min: 0 Max: 5.0 Fraction Digit: 1
Comments:
March 3, 2014 Page 3 of 19 Data Element Number: CPR.04
Data Element Name: Percentage of Chest Compressions With a Minimum of 2 Inches of Depth
National Element: No
State Element: No
Definition: The number of chest compressions that are 2 inches in depth or greater divided by the total number of compressions during the cardiac arrest time.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest
Attribute: Integer Min: 0 Max: 100
Comments:
March 3, 2014 Page 4 of 19 CPR Metrics and Time Measurement Data Dictionary
Data Element Number: CPR.05
Data Element Name: CPR Compression Fraction
National Element: No
State Element: No
Definition: The percentage of the cardiac arrest time that CPR compressions were provided.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest
Attribute: Integer Min: 0 Max: 100
Comments:
March 3, 2014 Page 5 of 19 Data Element Number: CPR.06
Data Element Name: Average Pre-Shock Time
National Element: No
State Element: No
Definition: The average number of seconds from the stoppage of CPR and the delivery of the defibrillatory shock.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest
Attribute: Integer Min: 0 Max: 200
Comments:
March 3, 2014 Page 6 of 19 CPR Metrics and Time Measurement Data Dictionary
Data Element Number: CPR.07
Data Element Name: Longest Pre-Shock Pause
National Element: No
State Element: No
Definition: Of all delivered defibrillatory shocks, the longest pre-shock pause that occurred during the cardiac arrest
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest
Attribute: Integer Min: 0 Max: 200
Comments:
March 3, 2014 Page 7 of 19 Data Element Number: CPR.08
Data Element Name: Percentage of CPR Compressions with Full Chest Recoil
National Element: No
State Element: No
Definition: The number of chest compressions where there was complete chest recoil or pressure on the chest was equal to, or less than 0, divided by the total number of compressions for the arrest time.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest
Attribute: Integer Min: 0 Max: 100
Comments:
March 3, 2014 Page 8 of 19 CPR Metrics and Time Measurement Data Dictionary
Data Element Number: CPR.09
Data Element Name: Average Ventilation Rate
National Element: No
State Element: No
Definition: The average ventilation rate calculated based on the ventilation-to- ventilation time interval for the total arrest time.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest, Airway
Attribute: Integer Min: 0 Max: 300
Comments:
March 3, 2014 Page 9 of 19 Data Element Number: CPR.10
Data Element Name: Percentage of Ventilations less than 12 per minute
National Element: No
State Element: No
Definition: The overall percentage of ventilations, based on the ventilation-to- ventilation time interval, that were less than 12 ventilations per minute for the total arrest time.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest, Airway
Attribute: Integer Min: 0 Max: 100
Comments:
March 3, 2014 Page 10 of 19 CPR Metrics and Time Measurement Data Dictionary
Data Element Number: CPR.11
Data Element Name: Maximum Cardiac Arrest ETCO2
National Element: No
State Element: No
Definition: The highest ETCO2 level documented during the cardiac arrest time.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest, Airway
Attribute: Integer Min: 0 Max: 100
Comments:
March 3, 2014 Page 11 of 19 Data Element Number: CPR.12
Data Element Name: ETCO2 Used
National Element: No
State Element: No
Definition: Indication if ETCO2 was captured or monitored during the cardiac arrest time.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest, Airway
Code List:
Code Description 01 No 03 Yes
Comments:
March 3, 2014 Page 12 of 19 CPR Metrics and Time Measurement Data Dictionary
Data Element Number: CPR.13
Data Element Name: External Mechanical CPR Device Used
National Element: No
State Element: No
Definition: Indication than an external mechanical CPR device was used during the cardiac arrest time.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest
Code Description 01 No External CPR Device Used 03 ZOLL Autopulse CPR Device Used 05 Physio-Control Lucas Device Used 07 Thumper Device Used 09 Other External CPR Device Used
Comments:
March 3, 2014 Page 13 of 19 Data Element Number: CPR.14
Data Element Name: Pre-External Mechanical CPR Device Pause
National Element: No
State Element: No
Definition: The seconds between the stoppage of manual CPR and the start of external mechanical CPR.
Recurrence: 0:1
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest
Attribute: Integer Min: 0 Max: 200
Comments:
March 3, 2014 Page 14 of 19 CPR Metrics and Time Measurement Data Dictionary
CPR Time Measurements
Data Element Numbers: eProcedure.01 and eProcedure.03
Data Element Name: Start Time of Manual CPR by EMS
Documented through two existing NEMSIS Version 3 Data Elements:
eProcedure.01: Date Time Procedure Performed eProcecure.03: Procedure Code = 89666000 (Cardiopulmonary Resuscitation Manual)
March 3, 2014 Page 15 of 19 Data Element Numbers: eProcedure.01 and eProcedure.03
Data Element Name: Start Time of Mechanical CPR by EMS
Documented through two existing NEMSIS Version 3 Data Elements:
eProcedure.01: Date Time Procedure Performed eProcecure.03: Procedure Code = 429283006 (Cardiopulmonary Resuscitation Mechanical)
March 3, 2014 Page 16 of 19 CPR Metrics and Time Measurement Data Dictionary
Data Element Numbers: eProcedure.01 and eProcedure.03
Data Element Name: Time of First Defibrillation by EMS
Documented through two existing NEMSIS Version 3 Data Elements:
eProcedure.01: Date Time Procedure Performed eProcecure.03: Procedure Code = 426220008 (External Ventricular Defibrillation)
March 3, 2014 Page 17 of 19 Data Element Number: CPRTime.01
Data Element Name: Date/Time of Return of Spontaneous Circulation (ROSC)
National Element: No
State Element: No
Definition: The date/time the patient regained spontaneous circulation without assistance.
Recurrence: 0:M
Usage: Optional
Not Values: No
Not Values Accepted: N/A
Pertinent Negatives: No
Is Nillable: No
Performance Measures: Cardiac Arrest
Format and Constraints = eProcedure.01
Comments:
March 3, 2014 Page 18 of 19 CPR Metrics and Time Measurement Data Dictionary
Data Element Number: eArrest.15
Data Element Name: Date/Time at End of CPR Event
Documented through existing NEMSIS Version 3 Data Elements:
eArrest.15: Date/Time Resuscitation Discontinued
March 3, 2014 Page 19 of 19