Section 28 30 00 Electronic Detection and Alarm

SIP-3020, SIP-4010, SIP-404 Outdoor PIR Using Three Dual Pyro Sensors and Synthesized Intelligent PIR Technologies

PART 2 – Products

2.01 GENERAL

The intent of these specifications is to describe the equipment and functional requirements of an outdoor intrusion detection system. Brand names and catalog numbers included in this specification are used to establish standards of quality and performance characteristics, not for the purpose of limiting competitive bidding.

A. The sensor shall be used as a PIR motion sensor in remote monitored CCTV applications. Areas of coverage shall be designed to match common fixed camera and lens combinations.

B. The sensor shall have a mounting height of between 7.6 and 13 feet.

C. A 3-axis accelerometer shall be incorporated to alert of unauthorized reorientation of the device.

D. The sensor shall provide an anti-masking feature, alerting to unauthorized covering of the sensor windows.

E. The sensor shall include blanking plates to mask areas of unwanted coverage.

F. The sensor shall have a high-grade mirrored optical array with three dual pyro sensors.

G. The sensor shall have an IP-65 rated polycarbonate housing.

H. All sensors shall be equipped with tamper resistant head adjustments to prevent unauthorized adjustment of the head position. I. The sensor shall have Double Conductive Shielding to block RFI and spurious light sources, minimizing false alarms.

J. The sensor shall include high, medium and low sensitivity settings for near or far monitoring zones.

K. The sensor shall utilize thermo and luminance sensors which shall monitor ambient temperature and light levels to reduce false alarms while maintaining optimum sensitivity.

2.02 ELECTRICAL SPECIFICATIONS

Detection Method Passive Infrared Detection Area SIP-3020 – 100 x 65 ft SIP-4010 – 130 x 33 ft SIP-404 – 130 x 13 ft Power Requirements 11-16VDC, 22-26VDC Current Draw 35 mA @ 12VDC, 70mA @ 24VAC Mounting Height 7.6 to 13 ft Sensitivity Selector Far Sensor: SH/H/M/L Near Sensor: SH/H/M/L Range Selector Far: ON/OFF Alarm Output NO, NC, 28VDC 0.2A Max Alarm Interval Off/15, 30, 60 Seconds Trouble Output NC 28VDC 0.2A Max Tamper Output NC 28VDC 0.1A Max Alarm Period Approx. 2 Seconds Warm-up Period Approx. 60 Seconds Dimensions 4 x 9 x 10.5 inches (WHD) Weight 42 oz (1,2 kg) Operating Temperature -40F to +140F with optional heater unit IP Rating IP65 2.03 The sensor shall have an accessory package including:

I. Dual Gang Box Adapter Plate

II. Paper Mounting Template

III. Allen Key

IV. Area Masking Seals

V. Tweezers

VI. Instruction Manual

VII. Area Template

VIII. Mounting Screws

IX. SIP-AM2012BR (Nickel Plated Brass M20 to 1/2"NPT)

2.04 The sensor shall have the following optional accessories available:

I. PIE-1 PoE Ethernet Encoder

II. SIP-HU Heater

III. SIP-MINIHOOD Sun/Snow Shield

IV. AVF-1 Area Viewfinder for Setup

V. AWT-3 Walk Tester for Setup 2.05 MECHANICAL SPECIFICATIONS

SIP-3020, SIP-4010, SIP-404 2.06 DETECTION AREA PATTERNS