Analog Storage Oscilloscope Pdf

Total Page:16

File Type:pdf, Size:1020Kb

Analog Storage Oscilloscope Pdf Analog storage oscilloscope pdf Continue Definition: Digital storage oscilloscope is defined as an oscilloscope that stores and analyzes a signal digitally, i.e. in the form of 1 or 0 it is preferable to store them as analog signals. A digital oscilloscope receives an input, stores it, and then displays it on the screen. The digital oscilloscope has advanced storage, launch and measurement capabilities. It also displays the signal both visually and numerically. The working principle of digital storage Oscilloscope Digital oscilloscope digitizes and stores the input signal. This can be done with CRT (Cathode Beam Tube) and digital memory. The image below shows a block chart of the basic digital oscillator. The digitization can be done by taking input samples on periodic wave forms. The maximum frequency of the signal measured by a digital oscilloscope depends on two factors. These factors are sampling the speed of the Nature Converter. Sample speed - Sampling theory is used for safe input analysis. The sampling theory states that the frequency of the signal sampling should be twice as fast as the highest input frequency. Sampling speed means the analogue digital converter has a high fast conversion rate. Converter - The converter uses an expensive flash, the resolution of which decreases with the increase in sampling speed. Because of the sampling frequency, the bandwidth and resolution of the oscillation are limited. The need for an analogue of digital signal converters can also be overcome by a shift register. The input signal of the sample is stored in the change register. From the shear register, the signal is slowly read out and stored digitally. This method reduces the cost of the converter and works up to 100 mega-zaks per second. The only downside of a digital oscillat is that it doesn't accept data during digitization, so it had a blind spot at the time. Reconstruction of waves to visualize the final wave, oscilloscopes use the technique of interpolar polarization. Interpolarization is the process of creating new data points using known data points variables. Linear interpolation and sinusoidal interpolation are two processes of connecting dots together. In interpolation, lines are used to connect the dots together. Linear interpolation is also used to create an impulse or square wave shape. For the sinusoidal form of the wave, sinusoidation is used in oscilloscope. Oscilloscope, which stores and analyzes signals digitally in Tektronix TDS210 digital oscilloscope digital oscilloscope storage (often abbreviated DSO) is an oscilloscope that stores and analyzes signal digitally, rather than using analog methods. Currently, the most common type of oscillators in use is due to advanced Storage, display and and features that it usually provides. The input analog signal is sampled and then converted into a digital record of the amplitude of the signal at each time of the sample. The sampling frequency should be no less than Nyquist's speed to avoid a pseudonym. These digital values are then converted back into an analog signal for display on the cathode beam tube (CRT), or converted as needed for various possible types of output - liquid crystal mapping, chart recorder, plotter, or network interface. The cost of digital oscillating to store data varies greatly; Bench-top standalone tools (complete with displays) start at US$300 or even less, with high performance models selling for tens of thousands of dollars. Small, limited-size, limited-size models can run for as little as $50. Comparison with analog storage The main advantage over analog storage is that the stored traces are as bright as sharply defined, and written as quickly as unpreserved traces. Traces can be stored indefinitely or are discharged to an external storage device and recharged. This allows, for example, to compare the purchased trace from the system being tested with the standard trace acquired from a known system. Many models can display a waveform before a trigger signal. Digital oscilloscopes typically analyze wave shapes and provide numerical values as well as visual displays. These values usually include averages, maxims and lows, root average square (RMS) and frequencies. They can be used to capture transient signals when working in single-scan mode, without limiting the brightness and speed of recording analog oscillation storage. The trace you display can be manipulated after the acquisition; Part of the display can be enlarged to make small details more visible, or a long footprint can be viewed in a single display to identify areas of interest. Many tools allow you to annotate a saved footprint by the user. Many digital oscilloscopes use flat display panels similar to those made in large volumes for computers and television displays. Digital storage oscilloscopes can include interfaces such as a parallel printer port, a serial port RS-232, an IEEE-488 bus, a USB port or Ethernet that allows remote or automatic control and transmission of captured wave forms to an external display or storage. A PC based on a digital Oscillator-based personal computer relies on pCs for user interface and display. Front-end schemes, consisting of input amplifiers and analog digital converters, are packaged separately and communicate with the PC via USB, Ethernet other interfaces. In one format, the front end is assembled on a plug-in extension map that connects to a backplane computer. PC-based OSCilloscopes can be less expensive than an equivalent standalone tool because they can use the memory, display and keyboard of an attached PC. The display can be and the purchased data can be easily transferred to PC hosted software applications such as spread sheets. However, the PC-host interface can limit the maximum speed of data transfer for acquisition, and the host PC can produce enough electromagnetic noise to interfere with measurements. Inquiries : Ian Hickman (1997), digital storage oscilloscopes, Newnes, ISBN 978-0-7506-2856-3 - Hughes Electrical and Electronic Technology, Pearson Education, 2008, page 953, ISBN 978-0-13- 206011-0 - Charlie Sorrell (May 13, 2009), DIY Oscilloscope is awesomely accessible, Wired Morris (2001), Principles of Measurement and Devices, Butterworth-Heinemann, page 211, ISBN 978-0-7506-5081-6 - Alan S. Morris, Reza Langari Measurements and Instruments: Theory and Application, Academic Press, 2011 ISBN 1 0123819628 page 180 External Links Digital Storage Oscilloscope Measurements Effective Number of Bits (ENOB) The effect of digital oscillation blind time on your measurements Benefits of the digital trigger system extracted from the This article needs additional quotes to verify. Please help improve this article by adding quotes to reliable sources. Non-sources of materials can be challenged and removed. Find sources: Oscilloscope Types - News Newspaper Book Scientist JSTOR (February 2016) (Learn how and when to remove this template message) This section of the Oscilloscope article, discussing different types and models of oscilloscopes in more detail. Digital oscilloscopes While analog devices use ever-changing voltages, digital devices use binary numbers that correspond to voltage samples. In the case of digital oscilloscopes, an analog digital converter (ADC) is used to change measured voltage in digital information. Wave shapes are taken as a series of samples. Samples are stored, accumulating until enough is taken to describe the shape of the wave, which is then collected for display. Digital technology allows you to display information with brightness, clarity and stability. There are, however, limitations, as with the performance of any Oscillators. The highest frequency with which an oscilloscope can work is determined by the analog bandwidth of the front end components of the device and the sampling frequency. Digital oscilloscopes can be classified into two main categories: digital storage oscilloscopes and digital sample oscilloscopes. New variants include PC-based PC-based OScilloscopes (which are attached to PCs for processing and displaying data) and mixed signal oscilloscopes (which use other functions in addition to voltage measurement). Digital Storage oscilloscope Home article: Digital OScilloscope Screen digital oscillatory from HP that that Cathode-beam tube display digital oscilloscope storage, or DSO for short, is now the preferred type for most industrial applications. Instead of cathode beams such as storage, DSOs use digital memory that can store data for as long as it takes without degradation. Digital storage oscilloscope also makes it difficult to process signal high-speed digital signal processing circuits. Vertical input is digitized by an analog digital converter to create a data set stored in the microprocessor's memory. The data set is processed and then sent to the display, which at the beginning of the DSOs was a cathode of the beam tube, but today is a flat LCD panel. DSOs with colored liquid crystal displays are common. The sampling dataset can be stored in internal or removable storage or sent via LAN or USB for processing or archiving. The screen image can also be stored for internal or removable storage or sent to a built-in or externally connected printer without the need for an Oscilloscope camera. Oscilloscope's own signal analysis software can extract many useful functions of the time domain (e.g., lifting time, pulse width, amplitude), frequency spectrums, histograms and statistics, perseverance maps, and a large number of parameters relevant to engineers in specialized fields such as
Recommended publications
  • Gkougkousis RD50 B Setup.Pdf
    37TH RD50 Workshop A comprehensive MIP measurement & analysis system Evangelos –Leonidas Gkougkousis CERN, EP-R&D WG 1.1: Hybride Pixel Detectors Geneva – November 19th, 2020 Mechanics General Overview Spacers M4x20 screws All parts in transit from CERN since last Friday source container source support back Trigger source support DUT front Aluminum support assembly (reduced size) baseplate 20 / 11 / 2020 E. L. Gkougkousis 2 Mechanics Individual Pieces https://twiki.cern.ch/twiki/bin/view/Main/HGTDSensorTesting#Mechanics • Assembled on aluminum Specifications breadboard base Outer dimensions 250 x 220 x 10 mm • M5 tapped hole grid, 15 mm Material Aluminum Plate spacing Grid type M5 • 10 mm thickness recommended Grid size 16 X 14 Grid spacing 15 mm for stability Base Distance form grid end to edge 12.5 mm + + = • 3-piece aluminum L-shaped support frame for board alignment and mounting • M5 screws used for fixing to baseplate & mount sensor board to the frame Plane support Plane • 165 mm x 120 mm outer dimentions • 2xM5, 10 mm nuts per board mounting hole as spacers. • 2-pice support designed for CERN sources • Encapsulates an L-frame plane support • 3D printed piece + • ABS with a 99% fill factor for mechanical stability • Non-metallic parts to avoid bremsstrahlung • Assures correct alignment with boards and sensors Source Holder Source 20 / 11 / 2020 E. L. Gkougkousis 3 Electronics st 1 Stage Amplifier • Electronics based on UCSC single channel board • High frequency SiGe (~2GHz) common emitter first stage charge amplifier (470 Ohm trans-impedance)
    [Show full text]
  • Instruction Manual
    DUAL-BEAM OSCILLOSCOPE TYPE 502 INSTRUCTION MANUAL TEKTRONIX, INC. MANUFACTURERS OF CATHODE-RAY AND VIDEO TEST INSTRUMENTS Sunset Highway and Barnes Road • P. O. Box 831 • Portland 7, Oregon, U. S. A. Phone: CYpress 2-2611 • Cables: Tektronix -1 TYPE 502 SERIAL NUMBER PREFACE We have tried to provide you with the best instrument we can. In doing this we sometimes make changes in our products after the instruction manuals have been printed. Many changes are made to give you the benefit of the latest circuit improvements devloped in our engineering department, and to accomodate improved com­ ponents as they become available. Our Test and Calibration En­ gineers sometimes hand tailor the circuits to provide optimum in­ dividual performance. When a particular instrument is changed in any manner, its manual is corrected accordingly. That is why the instrument serial number is written on the title page of this manual. If you need repair parts for an instrument, refer to the manual that belongs to that particular instrument. This manual begins with a list of Specifications, so that you will know the characteristics of your instrument. The second section provides information on cooling and connecting the power trans­ former for various input voltages. The third section gives you some of the principle ways in which you can operate your instrument. Next is the Circuit Description, where the circuitry of your instru­ ment is described in a detailed form. The Maintenance and Recali­ bration sections are last. Here you will find information on trouble­ shooting and repairing your instrument and on carrying out a re­ calibration of the instrument, if necessary, in the field.
    [Show full text]
  • Saleae Logic Usb Protocol
    Saleae Logic Usb Protocol Stig often ensconced tremulously when superorganic Jared swatters influentially and advertises her indispensable. Is Kimball huffiest when Jeremias requoted genetically? Tuned or apparitional, Rudiger never dodders any dismemberments! History of the scope, while following information at a logic analyzer that places to test equipment works better browsing experience, usb protocol in the waveform The protocol analyzers within a counterfeit for further processing to saleae logic usb protocol analyzers that are limited. You can only vote one channel to an odd condition. What comes in the box? Easily generate and health track move your quotes. Deeper sample memory see the Logicport. The usb throughput. Are the Input Channels Isolated from Each Other? This protocol data, usb port output waveform is a battery, and fifth bursts can fit nicely in. The logic analyzers to solve very time? Sorry an error occurred. So the first interesting fact is that I basically bought only the PCB with no firmware inside. PC peripherals consisting only of the signal acquisition hardware, with all the display and analysis work handled by a software program on the PC. Are there any features that you think would have been helpful? You make it enjoyable and you still care for to keep it smart. Therefore they can saleae logic usb protocol analyzers that they will give you can only have installed, electrical engineering projects. Can i access to memory usage is great is done on the start before the oscilloscope types of the din, including a logic analyzer only set are great. Two types of triggers are supported: Trigger on Edge and earn on Pulse Width.
    [Show full text]
  • The New Analog-/ Digital Scope Generation from HAMEG with Autoset, Save / Recall, Readout / Cursor and RS-232 Interface
    OSCILLOSCOPE The new Analog-/ Digital Scope Generation from HAMEG with Autoset, Save / Recall, Readout / Cursor and RS-232 Interface Demands Solution Modern oscilloscopes must meet additional demands without neglecting the advantages The following description explains some of their predecessors. Oscilloscopes, which are user selectable between the analog and advantages of these oscilloscopes. the digital mode, are undoubtedly the most versatile displaying instruments and meet this The excellent frequency response of requirement. In spite of additional functions, such instruments must be user friendly and the signal amplifiers and the stable trig- easy to operate. gering abilities from only 5mm peak-to- peak on the screen, enable the scope to The main demands for signal display and measurement are display sine waves far beyond its -3dB frequency without any problems. With ● bright and sharp trace rectangular signals the instrument‘s own ● time base, single event capturing, XY and component test mode overshoot is less than 1%. ● signal amplifiers with high bandwidth and wide dynamic range Both scopes contain a second trigger system to ensure stable triggering of even ● distortion free ”probe tip to screen” signal display asynchronous signal components. ● high input sensitivity with minimum noise With its second time base, the ● wide range of Y and X deflection coefficients HM1507-2 scope is capable of displaying ● stable triggering with multiple coupling modes not only the signal itself but also a freely ● delayed time base mode with second trigger system selectable expanded section in mixed mode, ● automatic signal related instrument and CURSOR set up according to the time base and trigger delay ● manual CURSOR supported measurement settings.
    [Show full text]
  • Oscilloscope and Function Generator
    54 Carl von Ossietzky University Oldenburg – Faculty V - Institute of Physics Module Introductory laboratory course physics – Part I Oscilloscope and Function Generator Keywords: Anode, cathode, cathode ray tube, electron deflection, deflector plates, trigger, AC/DC coupling, direct voltage, alternating voltage, frequency, radian frequency, period, amplitude, phase, phase difference, peak and effective value of alternating voltages, LISSAJOUS figures, harmonic oscillation, peak and effective values of alternating voltage. Measuring program: Representation of function generator signals, trigger level and trigger slope, temporal course of the light intensity of a light bulb and a fluorescent lamp, peak and effective value of the line voltage, investigation of a damped harmonic voltage signal, duration of a light flash, frequency stability of a stroboscope, LISSAJOUS figures. References: /1/ WALCHER, W.: „Praktikum der Physik“, Teubner Studienbücher Physik, Teubner-Verlag, Stuttgart /2/ EICHLER, H. J., KRONFELDT, H.-D., SAHM, J.: „Das Neue Physikalische Grundpraktikum“, Springer-Verlag, Berlin among others /3/ GERTHSEN, C. u.a.: „Physik“, Springer-Verlag, Berlin among others 1 Introduction The oscilloscope counts among the important measuring instruments in experimental physics. It makes it possible to observe and to measure quantitatively the course of an electric voltage Uy as a function of time t or as a function of voltage Ux in „real-time“. The temporal course of all physical quantities that can be converted to an electrical voltage using a suitable sensor can be displayed with an oscilloscope1. There are few restrictions regarding the amplitude and frequency of the measurable signals: if you are prepared to spend enough money, you will certainly find an oscilloscope which meets the requirements.
    [Show full text]
  • The History and Technology of Oscilloscopes an Overview of Its Primary Characteristics and Working Principles
    PHOTOS: NASA GLENN RESEARCH CENTER (NASA-GRC) & GRID PATTERN- © DIGITAL VISION The History and Technology of Oscilloscopes An overview of its primary characteristics and working principles scilloscopes are one of the main tools for analyz- ing principle is the same there are two main types of oscillo- ing electrical signals. The primary information scopes: analog and digital. obtained from the waveform of the signal is The aim of this article is to provide an overview of the Ovisualization of its amplitude variation over main characteristics of the different types of oscilloscopes time. Oscilloscopes are excellent tools for testing, debug- and correlate their evolution with the development of the ging, and troubleshooting because they can easily detect underlying technologies they incorporate. waveforms and demonstrate if the elec- trical components or circuit modules J. Miguel Dias Pereira Introduction are working properly. Oscilloscopes André-Eugène Blondel was a French also provide support during the design physicist who was born on 28 August of new electronic circuits. In addition to electrical signals, 1863. He is known as the inventor of the electromagnetic other physical or chemical quantities can be measured by oscillograph, a device that enabled the observation of alter- using different probes that have been developed into an nating signals. The first oscillographs traced an ink record appropriate transducer. on a moving paper chart with a pen arm attached to a mov- Even if the basic philosophy of every oscilloscope’s work- ing coil. As a consequence of the working principle based December 2006 IEEE Instrumentation & Measurement Magazine 27 1094-6969/06/$20.00©2006IEEE on a set of mechanical devices, the first oscillographs had a ◗ visualization of the signal waveform in the display unit very low bandwidth in the range of 10–19 Hz.
    [Show full text]
  • Course Structure of B.Sc. General Degree Program Sr.No
    Syllabus for B.Sc. Electronics (General and Honours) Degree Program under CBCS w.e.f 2017-18 Table I: Course Structure of B.Sc. General Degree Program Sr.No Semester Course Code Subject Title Credits (T+P) 1. I DSC 1A Network Analysis and Analog Electronics 4+2 2. II DSC 1B Linear and Digital 4+2 Integrated Circuits 3. III DSC 1C Communication 4+2 Electronics 4. IV DSC 1D Microprocessor 4+2 and Microcontrollers 5. V (any one DSE 1A Computer Networks and Administration 4+2 to be 6. Embedded Systems 4+2 offered) 7. Biomedical and Pharmaceutical 4+2 Instrumentation 8. Electronics Instrumentation 4+2 9. VI (any one DSE 1B Photonics 4+2 10. to be Power Electronics 4+2 11. offered) HDL and FPGA 4+2 12. Industrial Automation 4+2 Table II: Course Structure of B.Sc. Honours Degree Program Sr.No Semester Course Code Subject Title Credits (T+P) 1. I DSC 1 Network Analysis and Analog 4+2 Electronics 2. I DSC 2 Mathematics Foundation for 4+2 Electronics 3. I DSC 3 C Programming 4+2 4. II DSC 4 Linear and Digital Integrated 4+2 Circuits 5. II DSC 5 Applied Physics 4+2 6. II DSC 6 Photonics 4+2 1 Goa University Taleigao Plateau, Goa. 7. III DSC 7 Communication Electronics 4+2 8. III DSC 8 Transducers and Instrumentation 4+2 9. III DSC 9 Power Electronics 4+2 10. IV DSC 10 Microprocessors and Microcontrollers 4+2 11. IV DSC 11 Control system 4+2 12.
    [Show full text]
  • Autoranging Combiscope™ Instrument
    I Autoranging CombiScope Instrument PM3370B-PM3380B-PM3390B PM3384B-PM3394B Reference Manual 4/1-Dec-2000 ® II IMPORTANT In correspondence concerning this instrument please give the model number and serial number as located on the type plate on the rear of the instrument. NOTE: The design of this instrument is subject to continuous development and improvement. Consequently, this instrument may incorporate minor changes in detail from the information provided in this manual. Fluke Corporation Fluke Industrial B.V. P.O. Box 9090 P.O. Box 680 Everett WA 7600 AR Almelo 98206-9090, USA The Netherlands Copyright 1996, 1998 Fluke Corporation All rights reserved. No part of this manual may be reproduced by any means or in any form without written permission of the copyright owner. Printed in the Netherlands III Thank you for purchasing this FLUKE oscilloscope. It has been designed and manufactured to the highest quality standards to give you many years of trouble free and accurate measurements The powerful measuring functions listed below have been combined with an easy and logical operation to let you use the full power of this instrument each and every day. If you have any comments on how this product could be improved, please contact your local FLUKE organization. FLUKE addresses are listed in the back of this REFERENCE MANUAL. There is a USERS GUIDE available containing: - OPERATOR’S SAFETY - INSTALLATION INSTRUCTIONS - OPERATING INSTRUCTIONS - HOW TO USE THE INSTRUMENT - FUNCTION REFERENCE IV MAIN FEATURES There are five models in this family of Fluke oscilloscopes. Each of these models is a combination of an analog real-time oscilloscope and a fully featured digital storage oscilloscope.
    [Show full text]
  • Applications of Cathode Ray Oscilloscope Ppt
    Applications Of Cathode Ray Oscilloscope Ppt Fine Erin usually housed some meshings or barbecue ingenuously. Subtorrid and left-handed Tab formulated noddinglysome novel or so renamed wailingly! hugely. Sometimes shallow Noah ceil her tephroite cheerly, but penultimate Garry propend Hence they can produce the cathode ray oscilloscope Thus, intensity information builds up in cells where the waveform passes most often. Sampling oscilloscopes are used to capture exceedingly high frequency signals. Envelope mode is similar to peak detect mode. The vertical deflection plate moves the beams up and down and the horizontal beam moved the electrons beams left to right. Replace the pencil and the graph paper with an electron beam and a TV screen and you can see exactly how an oscilloscope draws its traces. What able the full scheme of CRO? Therefore they cannot express varying levels of intensity in the live signal. What can we use oscilloscopes for? This ppt format, applications of electric field service applications that a time base accuracy while digital multimeter as a scribd gift membership has a threshold voltage? The crt offers a basic pieces of information how solution to my problem The cathode- much matter how sorry They met ray tube for a graphing mechanism cap. The amplifier drives the vertical deflection plates with a voltage that is proportional to the vertical input. The electron gun whose amplitude signal can be equal distance between two plates are then passes a brightness. Sign up to view with full document! Application of CRO working of CRO The Electrical Portal. Please not your password to commitment in.
    [Show full text]
  • MDO3000 Series Mixed Domain Oscilloscope
    MDO3000 Series Mixed Domain Oscilloscope Product Selection and Comparison Guide 2 www.tek.com/mdo3000 Table of Contents About this Guide .............................................................4 Signal Generator Guide ................................................16 What You’ll Find in this Guide ............................................4 Signal Generator Types ...................................................16 Key Specifications ...........................................................16 Oscilloscope Guide ........................................................5 Output Frequency (Bandwidth) ..................................16 Oscilloscope Types ...........................................................5 Vertical (Amplitude) Resolution ...................................16 Key Specifications .............................................................5 Sample (Clock) Rate ..................................................16 Bandwidth ...................................................................5 Memory Depth (Record Length).................................16 Sample Rate ...............................................................6 Features to Consider .......................................................16 Record Length ............................................................6 Waveform Capture Rate ..............................................6 Upgrade Now or Later ..................................................18 For Mixed Signal Oscilloscopes (MSO) ..............................6 Performance Upgrades
    [Show full text]
  • Índice Memoria
    ÍNDICE MEMORIA Índice memoria .......................................................................................... 1 Resumen ................................................................................................... 3 Resum ....................................................................................................... 3 Abstract .................................................................................................... 3 CAPÍTULO 1: Introducción .................................................................... 5 1.1. Osciloscopio ................................................................................. 5 1.1.1. Escalado de la señal ................................................................ 6 1.1.2. Modo de filtrado AC o DC ......................................................... 6 1.1.3. Eje de referencia X e Y ............................................................. 7 1.1.4. Función de disparo. Trigger ...................................................... 7 1.1.5. Función Hold ........................................................................... 7 1.1.6. Ancho de banda ...................................................................... 7 1.2. Justificación del proyecto ............................................................... 8 CAPÍTULO 2: ESTUDIO DEL ARTE .......................................................... 9 2.1. Osciloscopios analógicos ................................................................ 9 2.1.1. Osciloscopios analógicos de tiempo real (ART) ...........................
    [Show full text]
  • Evaluating Oscilloscope Fundamentals
    Evaluating Oscilloscope Fundamentals Application Note This application note provides an overview of oscilloscope fundamentals. You will learn what an oscilloscope is and how it operates. We will discuss oscilloscope applications and give you an overview of basic measurements and performance characteristics. We will also look at the different types of probes and discuss their advantages and disadvantages. Table of Contents Introduction .....................1 Electronic Signals ................2 Introduction Wave properties ................... 2 Waveforms ....................... 3 Analog versus digital signals ......... 4 Electronic technology permeates What is an Oscilloscope and Why Do You Need One? ...........5 our lives. Millions of people use Signal integrity .................... 5 electronic devices such as cell phones, What an oscilloscope looks like ...... 6 televisions, and computers on a daily An oscilloscope’s purpose ........... 7 basis. As electronic technology has Types of oscilloscopes .............. 8 advanced, the speeds at which these Where oscilloscopes are used ....... 10 devices operate have accelerated. Basic Oscilloscope Controls and Today, most devices use high-speed Measurements ..................11 digital technologies. which are malfunctioning. They can Basic front-panel controls .......... 11 also help you determine whether or Softkeys ......................... 14 Engineers need the ability to not a newly designed component Basic measurements .............. 15 accurately design and test the behaves the way you intended. Basic mathematical functions ....... 16 components in their high-speed Oscilloscopes are far more powerful Important Oscilloscope digital devices. The instrumentation than multimeters because they allow Performance Characteristics ......17 engineers use to design and test their you to see what the electronic signals Bandwidth ....................... 17 components must be particularly well- actually look like. Channels ........................ 17 suited to deal with high speeds and Sample rate .....................
    [Show full text]