Engineered to be Stronger

SDWS TIMBER Screw Structural -to-Wood Connections Including Ledgers

(800) 999-5099 www.strongtie.com 2 U.S. Patents5,897,280;7,101,133 StateofFloridaFL13975 Codes/Standards: IAPMO-UESER-192, Strong-Drive resistant coatingmakesit suitable formanyinteriororexteriorapplications. less torque toinstallthancomparable fasteners,makingiteasiertodrive,andthecorrosion- projects where ahigh-strength attachmentisneeded.This0.220"diameterfastenerrequires structural wood-to-woodapplications,includingledger, andisalsoidealforawidevarietyof Features: Simpson Strong-Tie The bearing area (0.75"headdia.) Large washerheadprovides maximum the head greater control whenseating Under-head nibsoffer ® SDWSTIMBERScrew the evaluationreport. applications, asdescribedin exterior andpreservative-treated wood galvanization, makingitsuitableforcertain corrosion resistance equivalenttohot-dip Double-barrier coatingprovides ® Strong-Drive ® SDWSTIMBERscrew isspecificallydesigned for Size identificationonall SDWS screw heads superior holdingpower Bold thread designprovides Patented 4CUT applications the needforpre-drilling inmost installation torque andeliminates ensures faststarts,reduces ™ tip

F-F-SDWS14 © 2014 SIMPSON STRONG-TIE COMPANY INC. F-F-SDWS14 © 2014 SIMPSON STRONG-TIE COMPANY INC. Strong-Drive 10" at www.strongtie.com/videolibrary/SDWS.html Watch howquicklytheSDWSTIMBERscrew canbeinstalledcompared totraditionallagbolts 0.220 x10 0.220 x8 0.220 x6 0.220 x5 0.220 x4 0.220 x3 3" 4" 5" 6" 8" Dia. xL Size (in.) Thread Length (in.) 2 2 2 2 2 1

1⁄2 3⁄4 3⁄4 3⁄4 3⁄4 3⁄8 Fasteners Pack Per 12 12 12 12 12 12 0.220 Dia.(in.) ® Master Carton SDWSTIMBERScrew Packs Per 10 10 10 10 10 10 Retail Clam SDWS221000DBRC12 SDWS22800DB-RC12 SDWS22600DB-RC12 SDWS22500DB-RC12 SDWS22400DB-RC12 SDWS22300DB-RC12 Model No. Fasteners Retail andmini-bulkpacksincludeone,6-lobe,T-40 driverbit;bulkpacksincludetwobits Pack Per 50 50 50 50 50 50 Master Carton Packs Per 6 6 6 6 6 6 Retail Pack

SDWS221000DB-R50 SDWS22800DB-R50 SDWS22600DB-R50 SDWS22500DB-R50 SDWS22400DB-R50 SDWS22300DB-R50 Model No. Fasteners Pack 250 250 250 250 250 Per — watch thevideo Scan here to Mini-Bulk SDWS22800DBMB SDWS22600DBMB SDWS22500DBMB SDWS22400DBMB SDWS22300DBMB Model No. — Fasteners Pack

250 400 500 600 600 950 Per

SDWS221000DB SDWS22800DB SDWS22600DB SDWS22500DB SDWS22400DB SDWS22300DB Bulk Model No. 3 4 General LoadInformation Strong-Drive 4. 3. 3. 2. 1. 2. 1. See footnotes(1-5)inadjacenttable. 5. 0.75" Southern ,-Pine-FirandHem-FirLumber Southern Loads–DouglasFir-,Allowable Withdrawal Allowable ShearLoads–Spruce-Pine-FirandHem-FirLumber Allowable ShearLoads–DouglasFir-Larch PineLumber andSouthern 0.220 x10 0.220 x10 0.220 x3 0.220 x8 0.220 x6 0.220 x5 0.220 x4 0.220 x3 0.220 x8 0.220 x6 0.220 x5 0.220 x4 For in-servicemoisture content greater than19%,useC and 8"betweenfastenersinarow. rows offasteners,4"between non-staggered rows offasteners shown ataC Tabulated reference withdrawaldesign values,Wand grain ofthemainmember. pounds where theentire thread lengthis embeddedintheside 6" enddistance,1 Minimum fastenerspacingrequirements toachievetableloads: multiplied byallapplicableadjustmentfactorspertheNDS. C Allowable loadsare shown atthewoodloaddurationfactorof member thickness. member. Fullpenetrationisthescrew lengthminusthe side All applicationsare based on fullpenetrationintothemain The tabulatedreference withdrawaldesignvalue,W the mainmember. pounds perinchofthethread penetrationintothesidegrainof The tabulatedreference withdrawaldesignvalue,W, isin with thescrew axisperpendicular tothefaceofmember. Loads are basedoninstallation intothesidegrainofwood building codeuptoaC Dia.x L Dia.x L D Size Size (in.) (in.) SDWS221000DB =1.0.Loadsmaybeincreased forloaddurationperthe SDWS22300DB SDWS22800DB SDWS22600DB SDWS22500DB SDWS22400DB Model No. SDWS221000DB SDWS221000DB D SDWS22300DB SDWS22800DB SDWS22600DB SDWS22500DB SDWS22400DB SDWS22300DB SDWS22800DB SDWS22600DB SDWS22500DB SDWS22400DB =1.0.Loadsmaybe increased forloadduration Model Model 7⁄16 No. No. " edgedistance, D =1.6.Tabulated valuesmustbe ® Fastener 0.220" Length SDWSTIMBERScrew (in.) 10 Thread Length 3 8 6 5 4 Thread Length (in.) 1 2 2 2 2 2 (in.) 1 2 2 2 2 2 3⁄4 3⁄4 3⁄4 3⁄4 3⁄8 1⁄2 3⁄4 3⁄4 3⁄4 3⁄4 3⁄8 1⁄2 Lengths 5⁄8

" betweenstaggered 405 405 405 405 385 190 1.5 405 405 405 405 405 255 1.5 3" Thread Length (in.) 1 2 2 2 2 2 Max 3⁄4 3⁄4 3⁄4 3⁄4 3⁄8 1⁄2 , is in , isin 365 365 365 290 285 Max — 405 405 405 405 405 M

2 — 2 =0.7. , are 4"

Main Member 365 365 365 290 215 2.5 — 405 405 405 360 305 2.5 — Design Value,(lbs./in.) W DF/SP Reference Withdrawal 214 214 214 214 179 164 5. 4. 6. SPF/HF Allowable ShearLoads(lbs.) Wood SideMember Thickness (in.) DF/SP Allowable ShearLoads(lbs.) Wood SideMember Thickness (in.) 6" Min.enddistance 5" member orpull-through ofa1 Values are basedonthelesserofwithdrawal from themain member includingthescrew tip. Embedded thread lengthisthatportionheldinthemain as referenced intheIBCorIRC. be multipliedbyallapplicableadjustment factorsfrom theNDS For in-servicemoisture contentgreater than19%,useC per thebuildingcodeuptoaC

365 365 365 290 405 405 405 360 — — — — 3 3 Main Member SDWS SpacingRequirements 6" HF/SPF 310 310 310 195 3.5 395 395 365 325 — — 187 187 187 187 160 151 3.5 — —

5 stagger ⁄ 8

" Min.

8" Min.betweenfasteners

310 310 310 395 395 365 — — — — — — 4 4 Main Member

Max. Reference Withdrawal Max. 1/2 D Design Value, W " sidemember. DF/SP =1.6.Tabulated valuesmust 590 590 590 590 425 245 280 280 210 395 395 355 4.5 4.5 — — — — — — 8"

280 280 395 395 — — — — — — — — Main Member 6 6 Max HF/SPF (lbs.) 495 495 495 495 380 225 395 280 M — — — — — — — — — —

8 8 =0.7.

10"

5 rows staggered between ⁄ 8 " Min. distance Min. edge 1 7 ⁄ 16 " rows staggered non- between 4" Min.

F-F-SDWS14 © 2014 SIMPSON STRONG-TIE COMPANY INC. F-F-SDWS14 © 2014 SIMPSON STRONG-TIE COMPANY INC. Strong-Drive Ledger Spacing 3. 2. 1. On-Center Spacing concrete wallshown forillustrationpurposes) Exterior cladding 10 psfDead 10 psfDead 10 psfDead 10 psfDead shown forclarity and flashingnot 60 psfLive 40 psfLive 60 psfLive 40 psfLive ICC-ES AC233testingoftheStrong-Drive Fastener spacingsare based onthelesserofsinglefastener Hem-, DouglasFir-Larch, Pinespecies. orSouthern -Larch, Pinespecies.Ledgershallbe orSouthern Solid-sawn rimboards shall beSpruce-Pine-Fir, Hem-Fir, loading conditionasrequired bysomejurisdictions. of materialscommonlyusedforrimboards, andanalternate above alsoprovides SDWS screw spacingforawiderrange Table R502.2.2.1.and2012IRCTable R507.2.Thetable SDWS screw spacingvalues are equivalentto2009IRC factor adjustment. with asafetyfactorof3.0.SpacingincludesNDSwetservice a safetyfactorof5.0orICC-ESAC13ledgerassemblytesting concrete wallshownfor illustrationpurposes) Condition Loading (Wood-framed lowerflooracceptable, Ledger (W Ledger-to-Rim Board Assembly ood-framed lowerfloor acceptable, blocking -to-Band JoistAssembly joist or Floor Nominal Ledger 2-2x 2-2x Size 2x 2x SDWS22400DB SDWS22500DB SDWS22500DB SDWS22400DB ® Model No. SDWSTIMBERScrew Screw

fastened percode 1 panel sheathing Wood structural ledger similar) (double 2" ledger shown 2" nominaldeck with Table space inaccordance stagger vertically SDWS woodscrews per Table Rimboard ⁄ 2 " max.thickness ® SDWSscrew with 2x SP, DF–2xSPF, HF 2x SP, DF–2xSPF, HF 2x SP, DF–2xSPF, HF 2x SP, DF–2xSPF, HF Minimum Size Material and Rim Board 1 1 1 1 1 1 1 1 1 1 1 1 1" OSB 1" OSB 1" OSB 1" OSB 5⁄16 5⁄16 5⁄16 5⁄16 1⁄8 1⁄8 1⁄8 1⁄8 1" LVL 1" LVL 1" LVL 1" LVL 1⁄4 1⁄4 1⁄4 1⁄4 " OSB " OSB " OSB " OSB " LSL " LSL " LSL " LSL " LVL " LVL " LVL " LVL 6. 5. 4. end ofledger 6" from top ofledgerandrimboard 1 screw. Forenddistancesbetween2"and4",pre- usinga of thetablespacingbetweenendscrew andtheadjacent distances between2"and6",use50%oftheload be locatednearthebottomofledger(seefigure). Forend 3" betweenrows andspaced perthetable.Endscrews shall of theledgerorrimboard, 6" from theendofledgerwith 5/32 maximum of Structural sheathingbetweentheledgerandbandshallbea Screws shallbeplacedat least 1 independent oftheSDWSscrews. Multiple ledgerpliesshallbefastenedtogetherpercode Up to Up to 1 6 ft. ⁄ 2 10 11 15 14 12 16 15 22 12 16 12 16 " drillbit. " minimumfrom Maximum On-CenterSpacingofFasteners(in.) Up to Up to SDWS Screw SpacingDetail 8 ft. 12 10 12 12 16 12 12 7 8 9 9 9 1/2 " thickandfastenedpercode. Maximum Deck JoistSpan screws SDWS wood spacing of On-center Up to Up to 10 ft. 10 13 10 10 6 7 9 8 7 9 7 7 Up to Up to 12 ft. 11 5 6 8 7 6 8 8 6 8 6 8

1/2 offset upto3"avoidinterference " from thetoporbottom Ledger fastenerspacingmaybe Up to Up to 14 ft. with joistattachment 4 5 7 6 5 7 7 9 5 7 5 7 1 1 ⁄ 2 " minimumfrom bottom ofledger and rimboard Up to Up to 16 ft. 4 4 6 5 4 6 6 8 4 6 4 6 Up to Up to 18 ft. — 4 5 5 4 5 5 7 4 5 4 5

row spacing 3" minimum 5 6 3. 2. 1. Allowable ShearValues forLedgerAttachmenttoStuds The SimpsonStrong-Drive Strong-Drive 4. were performedinaccordance withICC-ESAcceptanceCriteriaAC233. narrow faceofnominal2x studsaccording tothefollowingtable.Tests andanalyses Ledger-to-Stud Applications greater than19%,useC Design Specification(NDS).Forin-servicemoisture content All adjustmentfactorsshallbeappliedperthe2012National for SDWS. of C Allowable loadsare shown atthewoodloaddurationfactor different specificgravities,thelowervaluesshallbeused. 0.55, respectively. Where thesideandmainmembershave members havingaminimumspecificgravityof0.50,0.42,and Allowable loadsare based onDF, SPF/HF, andSPwood members shallbeloadedperpendiculartograin. solid sawnmainmembers(minimum2"nominal).Wood side Allowable loadsshallbelimitedtoparallel-to-grainloaded permitted bythebuildingcodeuptoaC For enddistancesbetween2"and4",pre-drill usinga end distancesbetween2"and6"use50%ofthetableloads. end. Theledgerenddistanceis6"forfullvalues.For loaded toward theendand 2½"whenloadedawayfrom the in thefigure. Thestudminimum enddistanceis6"when Fasteners shallbecentered inthestudandspacedasshown SDWS22400DB D Model =1.00.Loadsmaybeincreased forloaddurationas Direction Load M Length 3½ 1  =0.70. (in.)  4 ® " "

" SDWSTIMBERScrew 2x6 ledger 2x stud ® SDWSTIMBERscrews maybeusedtoattach aledgertothe D = 1.60. =1.60. Ledger 2x10 Size 2x6 2x8

5/32 " bit " bit

Screws per Number of Stud 2 3 4 9. 8. 7. 6. 5. Direction Load screw connections. connections, 0.67for3screw connections,and0.75for4 figure, usethetablevalues multipliedby:0.50for2screw For loadsintheoppositedirection from thatshowninthe distances showninthefigure are minimumdimensions. ledgers with3screws, use 2x8values.Spacingsandedge For 2x8ledgerswith2screws, use2x6values.For2x10 loads ofthe2x8SPledger. For 2x10SPledgers,usethenumberofscrews andallowable be adjustedinaccordance withtheNDS,section10.3. For LRFDvalues,thereference connectiondesignvaluesshall Longer lengthsofthescrew seriesmaybeused. main member(excludingthewoodstructuralpanel)ismet. per codeandtheminimumscrew penetrationof2½"intothe the woodstructuralpanelisfastenedtomainmember structural panelbetweenthesideandmainmemberprovided Screws maybeinstalledwith anintermediatelayerofwood 1 2 2   ⅝ ⅝ " 2x8 ledger " 2x stud "

" 1040 630 890 DF Allowable ShearLoad(lbs.)

SPF/HF 1040 565 855 Direction Load 1 2 2  2    ⅜ 1060 785 " SP — 2x stud 2x10 ledger "

"

" "

F-F-SDWS14 © 2014 SIMPSON STRONG-TIE COMPANY INC. F-F-SDWS14 © 2014 SIMPSON STRONG-TIE COMPANY INC. Strong-Drive Sole-to-Rim Connections 3. 2. 1. Allowable ShearValues forSole-to-RimConnections 0.220 x6 0.220 x5 0.220 x4 Size (in.) distance is6",andminimumedge Minimum spacingoftheSDWSis6"o.c.,minimumend C Allowable loadsare shownatthewoodloaddurationfactorof are limitedtoparallel-to-grainloading. Allowable loadsare basedontestingperICC-ESAC233and building codeuptoaC D =1.00.Loadsmaybeincreased forloaddurationbythe SDWS22600DB SDWS22500DB SDWS22400DB Model No. D =1.60. ® Sole Plate Nominal 2x or3x SDWSTIMBERScrew Size 2x 2x Penetration Screw pertable Rim Board Minimum 1.75 (in.) into 5⁄8 2 2 ". DF/SP Plate Sole 345 345 345 Rim Board 2x DF/SP HF Sole Plate SPF/ 295 295 295 5. 4. minimum screw penetration perthetableismet. the soleplateare independently fastenedperthecodeand A double2xsoleplateispermittedprovided themembersof minimum penetrationofthescrew intotherimboard ismet. structural panelisfastenedtotherimboard percodeandthe between thesoleplateandrimboard provided the wood Wood structuralpanelupto 1- 1/8 in. for SDWS22500DB and SDWS22600DB is permitted in.forSDWS22500DBandSDWS22600DBispermitted DF/SP Plate Sole 295 295 295 Rim Board 2x SPF/HF Allowable Loads(lbs.) per code sheathing fastened Wood structural Sole platepertable per table Rim board penetration Minimum middle ofrimboard Center screwin HF Sole Plate SPF/ 295 295 295

DF/SP Plate Sole 1 275 275 275

1/4 Rim Board 23/32 " Min.LVL in. for the SDWS22400DB or in.fortheSDWS22400DBor HF Sole Plate SPF/ 275 275 275 DF/SP Plate Sole 1 275 275 275

1/4 Rim Board " Min.LSL HF Sole Plate SPF/ 275 275 275 7 8 Strong-Drive applications. Loadsare derivedfrom assemblytestingbasedonICC-ESAC233. connection. Seethetablesbelowforrequired screw lengthsandallowableloadsforthese main memberforastandard connectionandbetweentheledgersheathingofa 2. 1. ONE or Spruce-Pine-Fir andHem-FirLumberAllowableSingleShearLoadswith See notesbelow Loads withONE Douglas Fir-Larch PineLumberAllowableSingleShear andSouthern 5/8 The Strong-Drive With GypsumBoard Interlayer(s) With Ledger-to-Stud Connections multiplied byallapplicableadjustmentfactors pertheNDS. of C Allowable loadsare shownatthewoodloaddurationfactor main member. All applicationsare basedonfullpenetration(6D)intothe the buildingcodeuptoaC " gypsumboard. Thislayerofgypsumistobelocatedbetweenthesidememberand Layers Layers Layer Layer TWO TWO ONE ONE D =1.0.Loadsmaybeincreased forloaddurationper 0.220 x10 0.220 x10 0.220 x10 0.220 x10 0.220 x8 0.220 x6 0.220 x5 0.220 x4 0.220 x8 0.220 x6 0.220 x5 0.220 x4 0.220 x4 0.220 x6 0.220 x5 0.220 x8 0.220 x4 0.220 x5 0.220 x6 0.220 x8 TWO Layersof Dim. XL Dim. XL Size Size (in.) (in.) ® SDWSTIMBERScrew maybeinstalledthrough oneortwolayersof SDWS221000DB SDWS221000DB SDWS221000DB SDWS221000DB SDWS22400DB SDWS22600DB SDWS22500DB SDWS22800DB SDWS22400DB SDWS22500DB SDWS22600DB SDWS22800DB SDWS22800DB SDWS22600DB SDWS22500DB SDWS22400DB SDWS22800DB SDWS22600DB SDWS22500DB SDWS22400DB D ® =1.6.Tabulated valuesmustbe or TWOLayersof SDWSTIMBERScrew Model Model 5/8 " GypsumBoard Thread Length Thread Length 2.375 2.375 2.375 2.375 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 (in.) (in.)

265 265 265 265 265 265 265 265 265 260 260 260 260 260 260 260 260 250 1.5 1.5 — —

5/8 " 5. 4. 3. GypsumBoard 265 265 265 265 265 265 265 265 235 235 235 190 235 235 235 190 2.0 2.0 — — — — Gypsum board mustbeattachedasrequired perthebuildingcode. For in-servicemoisture contentgreater than19%useC fasteners inarow. Seepage4. 4 Minimum fastenerspacingrequirements: 6" 1

" 7⁄16 betweennon-staggered rows offastenersand8" " edgedistance,

265 235 265 265 265 265 265 235 235 235 235 235 235 190 2.5 2.5 — — — — — — SPF/HF Allowable ShearLoads(lbs.) DF/SP Allowable ShearLoads(lbs.) Wood SideMember Thickness (in.) Wood SideMember Thickness (in.)

265 265 265 265 265 265 235 235 235 235 235 235 3.0 3.0 — — — — — — — — 5⁄8 " betweenstaggered rows offasteners, 235 255 255 255 255 200 200 200 200 200 3.5 3.5 — — — — — — — — — —

255 255 255 255 200 200 200 200 4.0 4.0 — — — — — — — — — — — — 255 255 255 255 -— 180 180 180 180 4.5 4.5 — — — — — — — — — — — end distance, enddistance, 255 255 between between 180 180 6.0 6.0 — — — — — — — — — — — — — — — — M =0.7.

8.0 8.0 — — — — — — — — — — — — — — — — — — — —

F-F-SDWS14 © 2014 SIMPSON STRONG-TIE COMPANY INC. F-F-SDWS14 © 2014 SIMPSON STRONG-TIE COMPANY INC. Strong-Drive With GypsumBoard Interlayer(s)(cont.) With Ledger-to-Stud Connections 2. 1. Ledger toRimBoard withONEorTWOLayersof 2009 and2012IRCCompliantSpacingforaSawnLumber 3. ICC-ES AC233testingoftheStrong-Drive Fastener spacingsare basedonthelesserofsinglefastener Hem-Fir, DouglasFir-Larch, Pinespecies. orSouthern Douglas Fir-Larch, Pinespecies.Ledgershallbe orSouthern Solid-sawn rimboard shallbeSpruce-Pine-Fir, Hem-Fir, independent oftheSDWSscrews. Multiple ledgerpliesshallbefastenedtogether percode NOT includeNDSwetservicefactoradjustment. on ICC-ESAC13withafactorofsafety of3.0.Spacingdoes with asafetyfactorof5.0orledgerassembly testingbased 100 psfLive 100 psfLive 10 psfDead 10 psfDead 10 psfDead 10 psfDead 10 psfDead 10 psfDead 40 psfLive 60 psfLive 40 psfLive 60 psfLive Condition Loading Ledger 2-2x 2-2x 2-2x Size 2x 2x 2x ® For ONEor TWO Layers For ONEor TWO Layers For ONEor TWO Layers SDWSTIMBERScrew of GypsumBoarduse: of GypsumBoarduse: of GypsumBoarduse: Gypsum Boarduse: Gypsum Boarduse: Gypsum Boarduse: Gypsum Boarduse: Gypsum Boarduse: Gypsum Boarduse: For TWO Layersof For TWO Layersof For TWO Layersof Screw ModelNo. For ONELayerof For ONELayerof For ONELayerof SDWS22600DB SDWS22600DB SDWS22600DB SDWS22400DB SDWS22400DB SDWS22400DB SDWS22500DB SDWS22500DB SDWS22500DB ® SDWSscrew

Minimum Size Material and 2x SPF, HF 2x SP, DFL 2x SPF, HF 2x SP, DFL 2x SPF, HF 2x SP, DFL 2x SPF, HF 2x SP, DFL 2x SPF, HF 2x SP, DFL 2x SPF, HF 2x SP, DFL Rimboard 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1" OSB 1" OSB 1" OSB 1" OSB 1" OSB 1" OSB

5/16 5/16 5/16 5/16 5/16 5/16 1/8 1/8 1/8 1/8 1/8 1/8 1" LVL 1" LVL 1" LVL 1" LVL 1" LVL 1" LVL

1/4 1/4 1/4 1/4 1/4 1/4 " OSB " OSB " OSB " OSB " OSB " OSB " LSL " LSL " LSL " LSL " LSL " LSL " LVL " LVL " LVL " LVL " LVL " LVL 7. 6. 5. 4. Gypsum board mustbeattachedasrequired perthebuildingcode. a maximumof½inchthickandfastened per code. Structural sheathingbetweentheledgerand therimboard shallbe inches betweenrows andspacedperTables 5and6.Seepage5. ledger orrimboard , 6inchesfrom theendofledgerwith3 Screws shallbeplacedatleast1½"from thetoporbottomof some jurisdictions. loadingconditionasrequired andanalternate by rimboards, for used SDWS screw spacingforawiderrange ofmaterialscommonly R502.2.2.1 and2012IRCTable R507.2.Thetablealsoprovides SDWS screw spacingvaluesare equivalentto2009IRCTable Up to 6 ft. 11 11 10 15 15 14 14 11 20 15 13 7 7 7 9 8 6 9

Maximum on-centerspacingoffasteners(in.) Up to 8 ft. 11 11 11 11 15 11 10 5 5 5 8 8 8 7 6 8 4 7 Maximum Deck JoistSpan 5/8 Up to 10 ft. " 12 4 4 4 6 6 6 9 9 5 9 5 9 7 9 8 4 6 GypsumBoard Up to 12 ft. — — — — 10 5 5 5 8 8 5 7 4 7 5 8 6 5 Up to 14 ft. — — — — — 5 5 5 7 7 4 6 6 5 9 7 6 4 Up to 16 ft. -— — — — — — — 4 4 4 6 6 5 5 4 8 6 5

Up to 18 ft. — — — — — — — — 4 4 5 5 5 5 4 7 5 4 9 10 Strong-Drive of thestudwithatolerance The screws mustbeinstalledintothemiddle Notes toinstallerregarding theattachment ofledgerstostuds: stud finder, or prerocking (attaching only a strip (attaching onlyastrip prerocking or finder, stud stud includingsnapping achalkline,using ensure proper placementof the screws inthe of center. Various methodscanbeusedto With GypsumBoard Interlayer(s)(cont.) With Ledger-to-Stud Connections 4. 3. 2. 1. with ONEorTWOLayersofGypsumBoard Allowable ShearValues forLedgerAttachmenttoStuds and 2½"whentheloadisawayfrom theend. minimum enddistanceis6"whentheloadtoward theend in thefigure. Theledgerminimum enddistanceis6".Thestud Fasteners shallbecentered inthestudandspacedasshown National DesignSpecification(NDS). applicable adjustmentfactorsshallbeappliedperthe2012 of C Allowable loadsare shown atthewoodloaddurationfactor have different specificgravities,thelowervaluesshall beused. and 0.55,respectively. Where thesideandmainmembers members havingaminimumspecificgravityof0.50,0.42, Allowable loadsare basedonDF, SPF/HF, andSPwood side membersshallbeloadedperpendiculartograin. solid sawnmainmembers(minimum2"nominal).Wood Allowable loadsshallbelimitedtoparallel-to-grainloaded as permittedbythebuildingcodeuptoaC SDWS22600DB D Model =1.00.Loadsmaybeincreased forloadduration Direction Load Length 3½ 1  (in.)  ® 6 2x stud " SDWSTIMBERScrew "

" 2x6 ledger Gypsum 3/16 " eitherside Ledger Size D 2x10 (in.) 2x6 2x8 = 1.60. All =1.60.All Number ofScrews per Stud support theledger screws. should beinstalledbetweenstuds toreceive and into thestudcannotbeachieved inthefield,blocking fastened tothestuds).Ifproper screw placement of gypsumattheledgerlocation until theledgeris 2 3 4 11. 10. 9. 8. 7. 6. 5. and pre drillwith For ledgerenddistancesbetween2"and6",use50%ofload Gypsum board mustbeattached asrequired perthebuildingcode. screw connections. connections, 0.67for3screw connections,and0.75for4 figure, usethetablevalues multipliedby:0.50for2screw For loadsintheoppositedirection from thatshowninthe distances showninthefigure are minimumdimensions. ledgers with3screws, use 2x8values.Spacingsandedge For 2x8ledgerswith2screws, use2x6values.For2x10 loads ofthe2x8SPledger. For 2x10SPledgers,usethenumberofscrews andallowable be adjustedinaccordance withtheNDS,section10.3. For LRFDvalues,thereference connectiondesignvalues shall the screw seriesmaybeused. (excluding thewoodstructuralpanel)ismet.Longerlengthsof the minimumscrew penetrationof2½"intothemainmember structural panelisfastenedtothemainmemberpercodeand between thesideandmainmemberprovided thewood Screws maybeinstalledwithalayerofwoodstructuralpanel Direction Load 1 2 2   2x stud ⅝ ⅝

" Gypsum 2x8 ledger " "

"

410 580 675 DF 5/32 " drillbit. Allowable ShearLoad(lbs.)

SPF/HF 365 555 675 Direction Load 1 2 2  2 2x stud    ⅜ 510 690 SP — " Gypsum 2x10 ledger "

" " "

F-F-SDWS14 © 2014 SIMPSON STRONG-TIE COMPANY INC. F-F-SDWS14 © 2014 SIMPSON STRONG-TIE COMPANY INC. Strong-Drive Attaching ExteriorFoamInsulation SDWS22DB StructuralWood Screws were evaluatedforcorrosion resistance usingICC-ESAC257. threaded fastenersusingICC-ESAC233andare thesubjectofIAPMO-UES ER-192.TheStrong-Drive insulation board intoeachwallstud.TheSDWS22DBandSDWS22screws were evaluatedasalternate 281 provides recommended spacingforfasteningto verticalfurringstripsthrough ½"to6"ofrigidfoam can onlybeusedinconditionswithdry-serviceandnowoodtreatment chemicals.Thetableonpage resistance equivalenttohot-dipgalvanization,whiletheproducts without “DB”inthemodelnumber SDWS products with“DB”inthemodelnumberhaveadouble-barriercoatingthatprovides corrosion UC3A) anduntreated woodmaybeuseddependingontheprotection needs oftheconstruction.The not typicallyrequire pre-drilling. Preservative-treated woodsuitablefordry-service(AWPA UC1,UC2, furring strips,rigid-foamboard andWSPsheathingintothewoodwallstudframing.Thefastenersdo foam board insulationoverwoodstructuralpanel(WSP)sheathing.Eachfastenerinstallsthrough Simpson Strong‑Tie 4. 3. 2. 1. Recommended Vertical FastenerSpacing SDWS221000DB vertical spacingperTable1 SDWS22500DB SDWS22800DB SDWS22400DB SDWS22600DB simplicity incomplete for ground details Foundation and framing asrequired bytheapplicable buildingcode. building codes.WSP sheathingshallbefastenedtothe design requirements inaccordance withtheapplicable Wood framing,furringandWSPsheathingshallmeetthe thread embedmentintheframingmember. greater. Table assumes furringstripthicknessof Spruce-Pine-Fir specieswithspecificgravity of0.42or thickness. Wood framingandfurringshallbeaminimum Wood wallframing(studs)shallbeaminimumof2"nominal of 15psiinaccordance withASTMC578orC1289. Foam sheathingshallhaveaminimumcompressive strength mapped before drivingscrews. systems intheexteriorwallinvolvedwithfasteningshallbe other mechanicalsystemsinexteriorwalls.All SDWS221000 Fasteners can penetrate wiring, plumbing, and CAUTION: Fastenerscanpenetratewiring,plumbing,and SDWS22800 SDWS22DB fastenersat be mappedbeforedrivingscrews. involved withthefasteningshall systems intheexteriorwall exterior walls.Allmechanical other mechanicalsystemsin penetrate wiring,plumbing,and CAUTION: Fastenerscan Vertical 1x4furringand studs withSDWS22or Model No. Foundation, insulation rigid foamattachedto and waterproofing Roof framing,typ. Exterior siding Exterior grade Figure 1:Wall Cross-Section per plan 0.220 x10 0.220 x5 0.220 x8 0.220 x4 0.220 x6 Dia. xL Size (in.) ® Strong-Drive ® SDWSTIMBERScrew Thickness ½ to1 1 Foam 4 to6 2 to4

1/2 (in.) ½ to2

1/4 ® SDWSTIMBERScrews maybeusedforinstallingexteriorrigid- Floor framing,typ. Figure 2 Treated sillplate Structural sheathing 1 Wall framing,typ. Spacing ⁄ 2 " to6" Stud (in.) 24 16 24 16 16 24 24 16 24 16 3/4 Rigidfoamboard in. and full in.andfull 24" o.c. ≤ 20 9. 8. 7. 6. 5. vertical spacingperTable1 installation instructions. the required thicknessandperformance forsidingmanufacturer connected components.Furringandsheathing shallprovide Screws shallbeinstalledsuchthattheyclosegapsbetween exposed screw headsare covered with foamandsealed. Metal fastenersconductheat,anditisrecommended that effects (i.e.ice)andothersupportedmaterials. of furring,claddingincludingfoaminsulation, environmental Maximum allowablecladdingweightshall betheadditiveweight board insulation. produced 0.015"ofassemblymovementwith6"thickrigidfoam Spacing recommendations are basedonaloadingthat loading (C Each fasteneriscapableofresisting 172lbsofoutplanewind SDWS fastenerscentered on studatrecommended

1x4 Furringaligned Maximum Allowable Cladding Weight Maximum Allowable with wallstuds Figure 2:FurringandRigid Exterior siding D =1.60)withnofurtherincrease allowed. Foam AttachmentDetail vertical spacingperTable1 simplicity incomplete for ground details Foundation and SDWS22DB fastenersat to beSupported(psf) be mappedbeforedrivingscrews. involved withthefasteningshall systems intheexteriorwall exterior walls.Allmechanical other mechanicalsystemsin penetrate wiring,plumbing,and CAUTION: Fastenerscan Vertical 1x4furringand studs withSDWS22or Foundation, insulation rigid foamattachedto and waterproofing Roof framing,typ. Exterior siding Exterior grade 18" o.c. 24" o.c. 25 per plan 1 foam board Structural sheathing Wall framing,typ.

⁄ 2 " to6" 16" o.c. 24" o.c. 30 Rigid Floor framing,typ. Figure 2 Treated sillplate Structural sheathing 1 Wall framing,typ. ⁄ 2 " to6" Rigidfoamboard 11 SDWS TIMBER Screw: the Anatomy Sinks in to of any great project Performance

Make way for a smooth finish

We recommend a test drive

Easy driving from here on

Start fast with no pre-drilling

The Strong-Drive® SDWS TIMBER screw is like no other. Its patented tip ensures fast starts, reduces torque and eliminates pre-drilling. The bold thread design provides superior holding power while the large, low-profile head eliminates washers. All of this and a double-barrier coating to resist corrosion – now that’s a fastener engineered to perform.

Code Listed: IAPMO UES ER-192

This flier is effective until December 31, 2016, and reflects information available as of August 1, 2014. 800-999-5099 This information is updated periodically and should not be relied upon after December 31, 2016; contact Simpson Strong-Tie for current information and limited warranty or see www.strongtie.com. www.strongtie.com © 2014 Simpson Strong-Tie Company Inc. • P.O. Box 10789, Pleasanton, CA 94588 F-F-SDWS14 8/14 exp. 12/16