ANSI/ASHRAE/ASHE Addendum P for Standard 170-2017

Total Page:16

File Type:pdf, Size:1020Kb

ANSI/ASHRAE/ASHE Addendum P for Standard 170-2017 © ASHRAE. Per international copyright law, additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE's prior written permission. ANSI/ASHRAE/ASHE Addendum p to ANSI/ASHRAE/ASHE Standard 170-2017 Ventilation of Health Care Facilities Approved by ASHRAE Standard Committee and the ASHRAE Board of Directors on February 5, 2020; by the American Society for Healthcare Engineering on December 19, 2019; and by the American National Standards Institute on March 2, 2020. This addendum was approved by a Standing Standard Project Committee (SSPC) for which the Standards Committee has established a documented program for regular publication of addenda or revisions, including procedures for timely, docu- mented, consensus action on requests for change to any part of the standard. Instructions for how to submit a change can be found on the ASHRAE® website (https://www.ashrae.org/continuous-maintenance). The latest edition of an ASHRAE Standard may be purchased on the ASHRAE website (www.ashrae.org) or from ASHRAE Customer Service, 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. E-mail: [email protected]. Fax: 678-539-2129. Tele- phone: 404-636-8400 (worldwide), or toll free 1-800-527-4723 (for orders in US and Canada). For reprint permission, go to www.ashrae.org/permissions. © 2020 ASHRAE ISSN 1041-2336 © ASHRAE. Per international copyright law, additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE's prior written permission. ASHRAE Standing Standard Project Committee 170 Cognizant TC: 9.6, Healthcare Facilities SPLS Liaison: Russell C. Tharp Michael P. Sheerin*, Chair Caleb Haynes Kenneth R. Mead* Frederick E. Granzow*, Secretary Robert N. Heinlein, Jr. Farhad Memarzadeh* David J. Anderson Richard D. Hermans* Michael S. Meteyer Amit Bhansali Nolan Hosking Richard D. Moeller* Robert Booth Aaron L. Johnson Kenneth A. Monroe Brendon J. Burley Michael R. Keen* Paul T. Ninomura* John M. Dombrowski* Dan Koenigshofer* Russell N. Olmsted* Travis R. English Paul R. Kondrat Heather L. Platt Gulledge Douglas S. Erickson* Peter H. Langowski* Maya Salabasheva Jeremy P. Fauber* Roger W. Lautz Amber M. Scales Jonathan J. Flannery* Pavel V. Likhonin Kevin A. Scarlett* Steven D. Friedman* Michael D. Locke Charles J. Seyffer Glenn Saint Aubin Gall* Stephanie J. Mages Gordon P. Sharp* Danette J. Hauck David M. Mason Erica Stewart* * Denotes members of voting status when the document was approved for publication ASHRAE STANDARDS COMMITTEE 2019–2020 Wayne H. Stoppelmoor, Jr., Chair Susanna S. Hanson Lawrence J. Schoen Drury B. Crawley, Vice-Chair Rick M. Heiden Steven C. Sill Els Baert Jonathan Humble Richard T. Swierczyna Charles S. Barnaby Srinivas Katipamula Christian R. Taber Niels Bidstrup Essam E. Khalil Russell C. Tharp Robert B. Burkhead Kwang Woo Kim Adrienne G. Thomle Thomas E. Cappellin Larry Kouma Michael W. Woodford Douglas D. Fick Cesar L. Lim Craig P. Wray Michael W. Gallagher Karl L. Peterman Jaap Hogeling, BOD ExO Walter T. Grondzik Erick A. Phelps Malcolm D. Knight, CO Steven C. Ferguson, Senior Manager of Standards SPECIAL NOTE This American National Standard (ANS) is a national voluntary consensus Standard developed under the auspices of ASHRAE. Consensus is defined by the American National Standards Institute (ANSI), of which ASHRAE is a member and which has approved this Standard as an ANS, as “substantial agreement reached by directly and materially affected interest categories. This signifies the concurrence of more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that an effort be made toward their resolution.” Compliance with this Standard is voluntary until and unless a legal jurisdiction makes compliance mandatory through legislation. ASHRAE obtains consensus through participation of its national and international members, associated societies, and public review. ASHRAE Standards are prepared by a Project Committee appointed specifically for the purpose of writing the Standard. The Project Committee Chair and Vice-Chair must be members of ASHRAE; while other committee members may or may not be ASHRAE members, all must be technically qualified in the subject area of the Standard. Every effort is made to balance the concerned interests on all Project Committees. The Senior Manager of Standards of ASHRAE should be contacted for a. interpretation of the contents of this Standard, b. participation in the next review of the Standard, c. offering constructive criticism for improving the Standard, or d. permission to reprint portions of the Standard. DISCLAIMER ASHRAE uses its best efforts to promulgate Standards and Guidelines for the benefit of the public in light of available information and accepted industry practices. However, ASHRAE does not guarantee, certify, or assure the safety or performance of any products, components, or systems tested, installed, or operated in accordance with ASHRAE’s Standards or Guidelines or that any tests conducted under its Standards or Guidelines will be nonhazardous or free from risk. ASHRAE INDUSTRIAL ADVERTISING POLICY ON STANDARDS ASHRAE Standards and Guidelines are established to assist industry and the public by offering a uniform method of testing for rating purposes, by suggesting safe practices in designing and installing equipment, by providing proper definitions of this equipment, and by providing other information that may serve to guide the industry. The creation of ASHRAE Standards and Guidelines is determined by the need for them, and conformance to them is completely voluntary. In referring to this Standard or Guideline and in marking of equipment and in advertising, no claim shall be made, either stated or implied, that the product has been approved by ASHRAE. © ASHRAE. Per international copyright law, additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE's prior written permission. (This foreword is not part of this standard. It is merely informative and does not contain requirements necessary for conformance to the standard. It has not been processed according to the ANSI requirements for a standard and may contain material that has not been subject to public review or a consensus process. Unresolved objectors on infor- mative material are not offered the right to appeal at ASHRAE or ANSI.) FOREWORD Addendum p incorporates updates to Table 7.1. a. A column is created indicating spaces where unoccupied turndown is acceptable. b. Table 6.4 is incorporated into Table 7.1 to remove confusion so that filter requirements will be uniformly applied. c. Space names are aligned with names appearing in FGI 2014 and indicating the appropriate sections in FGI 2014 where that space is referenced. Numerous spaces have been relocated within the table with no changes to their previous requirements, For these spaces previous locations are shown in strikethrough while the new locations are shown in underline. Note: In this addendum, changes to the current standard are indicated in the text by under- lining (for additions) and strikethrough (for deletions) unless the instructions specifically men- tion some other means of indicating the changes. Addendum p to Standard 170-2017 Revise Section 5 as shown. 5. PLANNING Owners/managers of health care facilities shall prepare a detailed program that shall include the clinical service expected in each space, the specific user equipment expected to be used in each space, and any special clinical needs for temperature, humidity, and pressure control. The program shall include space names and paragraph numbering references from the applicable version of the FGI Guidelines for Design and Construction of Hospitals and Outpatient Facili- ties for each space noted within the program. This program shall be prepared in the planning phase of design. Revise Section 6.4 as shown. The remainder of Section 6.4 is unchanged. 6.4 Filtration. Filter banks shall be provided in accordance with Table 6.47.1. Each filter bank with an efficiency of greater than MERV 12 shall be provided with an installed manometer or differential pressure measuring device that is readily accessible and provides a reading of differ- ential static pressure across the filter to indicate when the filter needs to be changed. All of the air provided to a space shall be filtered in accordance with Table 6.47.1, except as otherwise indicated in Sections 7.1, 8.1, and 9.1 for spaces that allow recirculating room HVAC units. Informative Note: For more information, see CDC (2003) in Informative Appendix B. Table 6.4 Minimum Filter Efficiencies Filter Bank No. 1 Filter Bank No. 2 Space Designation (According to Function) (MERV)a (MERV)a Operating rooms (ORs); inpatient and ambulatory diagnostic and therapeutic radiology; 7 14 inpatient delivery and recovery spaces Inpatient care, treatment, and diagnosis, and those spaces providing direct service or 7 14 clean supplies and clean processing (except as noted below); AII (rooms) Protective environment (PE) rooms 7 HEPAc,d Laboratory work areas, procedure rooms, and associated semirestricted spaces 13b NR NR = not required a. Informative Note: The minimum efficiency reporting value (MERV) is based on the method of testing described in ANSI/ASHRAE Standard 52.2 (ASHRAE [2017a]). b. Additional prefilters may be used to reduce maintenance for filters with efficiencies higher than MERV 7. c. As an alternative, MERV-14 rated filters may be used in Filter Bank No. 2 if a tertiary terminal HEPA filter is provided for these spaces. d. Informative Note: High-efficiency particulate air (HEPA) filters are those filters that remove at least 99.97% of 0.3 micron-sized particles at the rated flow in accordance with the testing methods of IEST RP-CC001.6 (IEST [2016]). ANSI/ASHRAE/ASHE Addendum p to ANSI/ASHRAE/ASHE Standard 170-2017 1 © ASHRAE. Per international copyright law, additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE's prior written permission.
Recommended publications
  • ASHRAE Position Document on Filtration and Air Cleaning
    ASHRAE Position Document on Filtration and Air Cleaning Approved by ASHRAE Board of Directors January 29, 2015 Reaffirmed by Technology Council January 13, 2018 Expires January 23, 2021 ASHRAE 1791 Tullie Circle, NE • Atlanta, Georgia 30329-2305 404-636-8400 • fax: 404-321-5478 • www.ashrae.org © 2015 ASHRAE (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE's prior written permission. COMMITTEE ROSTER The ASHRAE Position Document on Filtration and Air Cleaning was developed by the Society's Filtration and Air Cleaning Position Document Committee formed on January 6, 2012, with Pawel Wargocki as its chair. Pawel Wargocki, Chair Dean A. Saputa Technical University of Denmark UV Resources Kongens Lyngby, Denmark Santa Clarita, CA Thomas H. Kuehn William J. Fisk University of Minnesota Lawrence Berkeley National Laboratory Minneapolis, MN Berkeley, CA H.E. Barney Burroughs Jeffrey A. Siegel Building Wellness Consultancy, Inc. The University of Toronto Johns Creek, GA Toronto, ON, Canada Christopher O. Muller Mark C. Jackson Purafil Inc. The University of Texas at Austin Doraville, GA Austin, TX Ernest A. Conrad Alan Veeck BOMA International National Air Filtration Association Washington DC Virginia Beach, VA Other contributors: Dean Tompkins Madison, WI for his contribution on photocatalytic oxidizers Paul Francisco, Ex-Officio Cognizant Committee Chair Environmental Health Committee University of Illinois Champaign, IL ASHRAE is a registered trademark in the U.S. Patent and Trademark Office, owned by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. © 2015 ASHRAE (www.ashrae.org). For personal use only.
    [Show full text]
  • Guide to Understanding Condensation
    Guide to Understanding Condensation The complete Andersen® Owner-To-Owner™ limited warranty is available at: www.andersenwindows.com. “Andersen” is a registered trademark of Andersen Corporation. All other marks where denoted are marks of Andersen Corporation. © 2007 Andersen Corporation. All rights reserved. 7/07 INTRODUCTION 2 The moisture that suddenly appears in cold weather on the interior We have created this brochure to answer questions you may have or exterior of window and patio door glass can block the view, drip about condensation, indoor humidity and exterior condensation. on the floor or freeze on the glass. It can be an annoying problem. We’ll start with the basics and offer solutions and alternatives While it may seem natural to blame the windows or doors, interior along the way. condensation is really an indication of excess humidity in the home. Exterior condensation, on the other hand, is a form of dew — the Should you run into problems or situations not covered in the glass simply provides a surface on which the moisture can condense. following pages, please contact your Andersen retailer. The important thing to realize is that if excessive humidity is Visit the Andersen website: www.andersenwindows.com causing window condensation, it may also be causing problems elsewhere in your home. Here are some other signs of excess The Andersen customer service toll-free number: 1-888-888-7020. humidity: • A “damp feeling” in the home. • Staining or discoloration of interior surfaces. • Mold or mildew on surfaces or a “musty smell.” • Warped wooden surfaces. • Cracking, peeling or blistering interior or exterior paint.
    [Show full text]
  • A Comprehensive Review of Thermal Energy Storage
    sustainability Review A Comprehensive Review of Thermal Energy Storage Ioan Sarbu * ID and Calin Sebarchievici Department of Building Services Engineering, Polytechnic University of Timisoara, Piata Victoriei, No. 2A, 300006 Timisoara, Romania; [email protected] * Correspondence: [email protected]; Tel.: +40-256-403-991; Fax: +40-256-403-987 Received: 7 December 2017; Accepted: 10 January 2018; Published: 14 January 2018 Abstract: Thermal energy storage (TES) is a technology that stocks thermal energy by heating or cooling a storage medium so that the stored energy can be used at a later time for heating and cooling applications and power generation. TES systems are used particularly in buildings and in industrial processes. This paper is focused on TES technologies that provide a way of valorizing solar heat and reducing the energy demand of buildings. The principles of several energy storage methods and calculation of storage capacities are described. Sensible heat storage technologies, including water tank, underground, and packed-bed storage methods, are briefly reviewed. Additionally, latent-heat storage systems associated with phase-change materials for use in solar heating/cooling of buildings, solar water heating, heat-pump systems, and concentrating solar power plants as well as thermo-chemical storage are discussed. Finally, cool thermal energy storage is also briefly reviewed and outstanding information on the performance and costs of TES systems are included. Keywords: storage system; phase-change materials; chemical storage; cold storage; performance 1. Introduction Recent projections predict that the primary energy consumption will rise by 48% in 2040 [1]. On the other hand, the depletion of fossil resources in addition to their negative impact on the environment has accelerated the shift toward sustainable energy sources.
    [Show full text]
  • Initial Start-Up When Starting up the Cooler Refrigeration System for the First Time, the Following Events Occur
    SEQUENCE OF OPERATION COOLERS AND FREEZERS COOLERS All standard units are equipped with an adjustable thermostat located on the lower right hand side of the evaporator coil, on the inside of the walk-in. All units are set at the factory to the temperature requested by the customer. Minor adjustments in operating temperature may be made to suit your needs by a qualified refrigeration technician. Polar King recommends that you do not set the temperature colder than required, as this will cause unnecessary power consumption. Recommended temperature for a cooler ranges from +34° to +37° F, unless specified otherwise for special applications. Refrigeration - Initial Start-Up When starting up the cooler refrigeration system for the first time, the following events occur. The operating sequence is as follows: (1) Thermostat calls for refrigerant. (2) Liquid line solenoid valve opens, allowing refrigerant to flow. (3) Pressure control makes the control circuit and the condensing unit operates. (4) When the room thermostat is satisfied, the liquid line solenoid will close, and the compressor will pump down and turn off. (Fan on unit cooler will continue to run.) These units are designed for application conditions 33°F and above. CAUTION: DO NOT SET A COOLER BELOW 32°F OR DAMAGE MAY OCCUR. Defrost Defrost is accomplished during refrigeration off cycle. Four defrost cycles per day are programmed at the factory (4 a.m., 10 a.m., 4 p.m., and 10:00 p.m.). It may be necessary to change the defrost cycle times to fit your work schedule. The interior temperature may rise slightly during the defrost cycle.
    [Show full text]
  • Disparities in Ammonia, Temperature, Humidity, and Airborne Particulate Matter Between the Micro-And Macroenvironments of Mice in Individually Ventilated Caging
    Journal of the American Association for Laboratory Animal Science Vol 49, No 2 Copyright 2010 March 2010 by the American Association for Laboratory Animal Science Pages 177–183 Disparities in Ammonia, Temperature, Humidity, and Airborne Particulate Matter between the Micro-and Macroenvironments of Mice in Individually Ventilated Caging Matthew D Rosenbaum,1 Susan VandeWoude,2 John Volckens,3 and Thomas E Johnson3,* Animal room environmental parameters typically are monitored with the assumption that the environment within the cage closely mirrors the room environment. This study evaluated that premise by examining macro- (room) and microenvi- ronmental (cage) parameters in individually ventilated cages housing mice with variable amounts of bedding over a period of 17 d without cage changes. Intracage ammonia levels remained within recommended human guidelines but were higher than room levels, confirming that microisolation caging is efficient at preventing ammonia generated from animal waste from escaping into the room. Humidity and temperature within cages were consistently higher than room levels. Particles in the room predominantly consisted of fine particles (diameter less than 2.5 µm), presumably from the ambient atmosphere; some of these particles were found in the cage microenvironment. In addition, mouse activity within cages produced larger particles, and these particles contributed to substantially higher aerosol mass concentrations within the cage. These findings demonstrate that, although cage and room environmental parameters differ, knowledge of room environmental conditions can be used to predict certain conditions within the cage. This association is relevant in that typical animal care standard operat- ing procedures rely on room measurements, not intracage measurements, which arguably are more important for assessing animal welfare.
    [Show full text]
  • At the Request of the District, Environmental Control Systems, Inc, the District's Environmental Risk Engineers, Visited Charl
    Environmental Control Systems, Inc. Indoor Air Quality Investigation Charles F. Patton Middle School Executive Summary At the request of the district, Environmental Control Systems, Inc, the district’s environmental risk engineers, visited Charles F. Patton Middle School to visually assess surfaces and test the air quality in various regions of the school building. This process was completed on Wednesday, November 21 during the regular school day when school was in session. Upon their professional inspection and review, Environmental Control Systems concluded that there is no evidence of mold at Charles F. Patton Middle School. Below is a summary of the report provided by Environmental Control Systems, Inc. You may view the complete report by clicking here. Indoor Air Quality Investigation Report Summary - November 21, 2018 1. Currently, there are no EPA, CDC or OSHA regulations or standards for airborne mold contaminants, therefore, there are no quantitative health-based guidelines, values, or thresholds for acceptable, tolerable, or normal concentrations for airborne fungi spores. 2. Generally speaking, indoor mold types should be similar to, and airborne concentrations should be no greater than, those found outdoors and in non-complaint areas. 3. According to the EPA, there is no practical way to eliminate all mold and mold spores in an indoor environment. Spores can be found almost anywhere and can grow on virtually any substance, providing moisture is present. 4. Mold may begin growing indoors when mold spores land on wet surfaces. There are many types of mold, but none of them will grow without water. At the time of this investigation, there was no condensation on any horizontal or vertical surfaces as all surfaces were equal to or higher than room temperature.
    [Show full text]
  • Environmental and Safety Considerations for Solar Heating and Cooling Applications
    IMBSIR 78-1532 Environmental and Safety Con- siderations for Solar Heating and Cooling Applications David Waksman John Holton Solar Criteria and Standards Program Building Economics and Regulatory Technology Division Center for Building Technology National Engineering Laboratory National Bureau of Standards Washington, D.C. 20234 September 1978 Prepared for Department of Energy Office of Conservation and Solar Applications Washington, D.C. and Department of Housing and Urban Development Division of Energy, Building Technology and Standards Washington, D.C. 20410 "OC — 1 100 . U56 tf78-1532 / m faWeffa! Sireal of Stansf&ri* MAY 1 4 1979 NBSIR 78-1532 * »r ENVIRONMENTAL AND SAFETY CON- SIDERATIONS FOR SOLAR HEATING AND COOLING APPLICATIONS David Waksman John Holton Solar Criteria and Standards Program Building Economics and Regulatory Technology Division Center for Building Technology National Engineering Laboratory National Bureau of Standards Washington, D.C. 20234 September 1978 Prepared for Department of Energy Office of Conservation and Solar Applications Washington, D.C. and Department of Housing and Urban Development Division of Energy, Building Technology and Standards Washington, D.C. 20410 ; ; . a.c,: u j\, i \ : V. - - ( X id'..' U.S. DEPARTMENT OF COMMERCE, Juanita M. Kreps, Secretary Dr. Sidney Harman, Under Secretary Jordan J. Baruch, Assistant Secretary for Science and Technology NATIONAL BUREAU OF STANDARDS, Ernest Ambler, Director TABLE OF CONTENTS Page 1. INTRODUCTION 1 2. GENERAL PROVISIONS 1 3. FIRE SAFETY PROVISIONS . 2 3.1 FLAMMABLE MATERIALS 2 3.2 FIRE RESISTANCE OF BUILDING ASSEMBLIES 6 3.3 EMERGENCY ACCESS AND EGRESS 7 A. PROTECTION OF AIR AND POTABLE WATER 8 A. 1 PROTECTION OF POTABLE WATER 9 A.
    [Show full text]
  • 2009 ASHRAE Handbook—Fundamentals Covers Basic Prin- • Chapter 20, Space Air Diffusion, Has Been Completely Rewritten to Ciples and Data Used in the HVAC&R Industry
    2009 ASHRAE HANDBOOK FUNDAMENTALS I-P Edition Supported by ASHRAE Research 2009 ASHRAE® HANDBOOK FUNDAMENTALS Inch-Pound Edition American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. 1791 Tullie Circle, N.E., Atlanta, GA 30329 (404) 636-8400 http://www.ashrae.org ©2009 by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. All rights reserved. DEDICATED TO THE ADVANCEMENT OF THE PROFESSION AND ITS ALLIED INDUSTRIES No part of this publication may be reproduced without permission in writing from ASHRAE, except by a reviewer who may quote brief passages or reproduce illustrations in a review with appropriate credit; nor may any part of this book be reproduced, stored in a retrieval system, or transmitted in any way or by any means—electronic, photocopying, recording, or other—without permission in writing from ASHRAE. Requests for permis- sion should be submitted at www.ashrae.org/permissions. Volunteer members of ASHRAE Technical Committees and others compiled the infor- mation in this handbook, and it is generally reviewed and updated every four years. Com- ments, criticisms, and suggestions regarding the subject matter are invited. Any errors or omissions in the data should be brought to the attention of the Editor. Additions and correc- tions to Handbook volumes in print will be published in the Handbook published the year following their verification and, as soon as verified, on the ASHRAE Internet Web site. DISCLAIMER ASHRAE has compiled this publication with care, but ASHRAE has not investigated, and ASHRAE expressly disclaims any duty to investigate, any product, service, process, procedure, design, or the like that may be described herein.
    [Show full text]
  • The Empirical Analysis Model on Identifying Sick Building Syndrome in Hot Humid Tropical Buildings
    Civil Engineering and Architecture 9(1): 52-73, 2021 http://www.hrpub.org DOI: 10.13189/cea.2021.090105 The Empirical Analysis Model on Identifying Sick Building Syndrome in Hot Humid Tropical Buildings Nurrahmi Kartikawati1, Erni Setyowati2,*, Djoko Indrosaptono2 1Doctoral Program of Architecture and Urbanism, Engineering Faculty of Diponegoro University, Semarang, 50275, Indonesia 2Department of Architecture, Engineering Faculty of Diponegoro University, Semarang, 50275, Indonesia Received November 9, 2020; Revised December 22, 2020; Accepted January 20, 2021 Cite This Paper in the following Citation Styles (a): [1] Nurrahmi Kartikawati, Erni Setyowati, Djoko Indrosaptono , "The Empirical Analysis Model on Identifying Sick Building Syndrome in Hot Humid Tropical Buildings," Civil Engineering and Architecture, Vol. 9, No. 1, pp. 52 - 73, 2021. DOI: 10.13189/cea.2021.090105. (b): Nurrahmi Kartikawati, Erni Setyowati, Djoko Indrosaptono (2021). The Empirical Analysis Model on Identifying Sick Building Syndrome in Hot Humid Tropical Buildings. Civil Engineering and Architecture, 9(1), 52 - 73. DOI: 10.13189/cea.2021.090105. Copyright©2021 by authors, all rights reserved. Authors agree that this article remains permanently open access under the terms of the Creative Commons Attribution License 4.0 International License Abstract A tropical hot humid climate provides high 1. Introduction humidity that influences the occupant’s comfort. This study highlights a comparison of physical measurements One of the remarkable things in occupancy is the indoor and perceptions related to thermal comfort, indoor air comfort aspect and the occupant’s health. The comfort quality, and sick building syndrome (SBS) in tropical and health of the residents are inseparable from thermal humid climate buildings.
    [Show full text]
  • Humidity and Occupants Presentation
    Humidity and Occupants What the Latest in Humidity Research Means for You Presenters Matt Nowak North American Sales Manager Armstrong International Eric Brodsky, PE Director of Technology Research Products Inc. / Aprilaire / DriSteem Duncan Curd General Manager Nortec Humidity Ltd. Jeremy Wolfe National Sales & Marketing Manager CAREL USA Agenda 1. Fundamentals of Humidity • Key Terms and Definitions • How indoor humidity changes throughout the year • Where humidification matter most 2. Humidity and People • Historical Research • Impacts of moisture to the human body • Recent advances in humidity research 3. Recent Research • Microbiome Study Details • Example of Hospital Savings • Results and Recommendations 4. Humidity in Your Building • Technologies for Humidification • Cooling and Humidifying with Adiabatic Systems • Humidification with Steam • Case Studies / Installation Examples What is Humidity and How Do We Measure It? Humidity • The amount of water vapor in the air • Measured in “Absolute” or “Relative” terms Absolute Humidity • Mass of water in particular volume of air • Expressed as mass (grains/lbda or gw/kgda) Relative Humidity • Amount of water vapor in the air relative to how much it can hold at a given temperature (%) 25 20 15 Maximum Moisture Content Of Air Depends 10 5 0 On Air Temperature Grains Grains of/ Water Cubic Foot of Air 0 5 -5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 -10 100 Air Temperature (F) How Much Water Can the Air Hold? Air Heated From 10°F @ 100% RH to 70 °F 1 lb (kg) of Air Would Only Be Less Than 10% RH 35°F (2°C) 30 gr (2g/kg) The Psychrometric Chart Typical RH in Las Vegas, NV Typical Temps in Las Vegas, NV Need for Humidification Summer (July 19th) – 104F @ 10% RH = 72F @ 27.5% RH Winter (Dec.
    [Show full text]
  • New Guidance for Residential Air Cleaners- ASHRAE Journal Sep 2019
    TECHNICAL FEATURE ©ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal at www.epa.gov. This article may not be copied nor distributed in either paper or digital form without ASHRAE’s permission. For more information about ASHRAE, visit www.ashrae.org. New Guidance for Residential Air Cleaners BY LEW HARRIMAN, FELLOW/LIFE MEMBER ASHRAE; BRENT STEPHENS, PH.D, MEMBER ASHRAE; TERRY BRENNAN, MEMBER ASHRAE As HVAC&R professionals, we in the ASHRAE community are sometimes asked ques- tions about residential indoor air quality (IAQ) and how to improve it. What contami- nants are most hazardous? How do I get rid of a particular smell? Should I use this air cleaner or that filter? Sadly, our friends and family generally lose patience when we helpfully suggest: “Well, it’s complicated. But just read Chapters 46, 60 and 62 in the ASHRAE Handbook—HVAC Applications, because there’s great information in there.” In general, we find that information seekers are frustrated by such helpful advice. Usually, the question is repeated (with some heat) in a form such as: “You’re the professional. Can’t you boil it down? What should I DO in my HOUSE?” Fortunately, two new resources can help you better mainstream and social media. When you get questions answer such questions. First, the ASHRAE Residential from friends and family about residential air filtration Indoor Air Quality Guide1 is a comprehensive summary of and air cleaners, you may find the U.S. Enivronmental IAQ for homes and apartments, written by our mem- Protection Agency’s recently updated publications help- ber colleagues and published by ASHRAE in 2018.
    [Show full text]
  • Sick Building Syndrome by WHO.Pdf
    Sick building syndrome By: World Health Organization Regional Office for Europe Summary Sick Building Syndrome (SBS) describes a medical condition where people in a building suffer from symptoms of illness or feel unwell for no apparent reason. The symptoms tend to increase in severity with the time people spend in the building, and improve over time or even disappear when people are away from the building. Sick Building Syndrome results in substantial disruption of people's work performance and personal relationships, and considerable loss of productivity. Sick Building Syndrome is wide spread and may occur in offices, apartment houses, nurseries and schools, resulting in substantial costs to the community. Even though the cause effect relations are unclear it is possible to remedy buildings with SBS problems, and for new buildings the chances of avoiding SBS problems are also good. Local Government actions can be both for implementing curative measures and for taking preventive actions. These measures and actions range from simple to radical. In recent years it has become apparent that occupants of buildings suffer a number of relatively minor illnesses where there is no apparent cause, yet it has been established that these are caused in some way by the building. The symptoms are varying degrees of irritation of the eyes, nose, throat or skin plus general symptoms such as lethargy and headaches. Because these illnesses may happen in the building or elsewhere, it was initially difficult to show that they could be caused by the building. While these symptoms may seem trivial at first sight, together they are a substantial problem.
    [Show full text]