Complements and Accessories for 127 , TitroMatic and Sampler

92 42. “Concorde” push-button hand probe. 92 40. 3-button mouse. For attaching to Burette and MultiBurette. For connecting to the Burette and MultiBurette, making Includes the reagent outlet tube, 0.8 x handling of the equipment much 1.5 mm. easier. It is designed ergonomically to fit into the hand, so that dispensing can be performed with a single finger. 92 41. 17-key numeric keypad. Can be connected to Burette, MultiBurette, PH-Burette and TitroMatic. 91 99. Cotton filter cartridge. Makes keying in codes easier. Adapted directly to the cap. 90 13. Standard PC keyboard. Very useful for all CRISON instruments. 92 00. Drier cartridge with molecular Used for entering data such as company or operator sieve. name, etc. These details will appear on reports from the Apart from the sieve it contains a silica printer and all those sent to a PC. gel indicator. Adapted directly to the bottle cap.

87 29. Bottle cap set, DIN 45 screw. Includes a joint for fixing the PTFE tube.

90 53, cable for interconnecting CRISON modules. 90 60. 1 l plastic bottle, DIN 45 screw.

90 61. 1 l topaz glass bottle, DIN 45 screw. 91 35, cable for connection to PC. For Burette, MultiBurette, PH-Burette and TitroMatic.

87 XX. Cable for connection to balance. For Burette, MultiBurette and TitroMatic. Specify balance “pin out”. 82 00. Printer 82 Dot-matrix printer, does not require thermal paper. Supplied with cable 87 20. Support for burette for connection to outlet tube. Burette, MultiBurette, Adapted directly to the reagent PH-Burette and bottle cap. TitroMatic.

87 21. Protective hood. Recommended for performing 90 00. Printer 82 paper. Burette testing or calibration. Bag with 10 rolls. Installed on the balance, and used as a support for the liquid in- and outlet tubes. Also prevents evaporation. 90 01. Printer 82 ribbon. Bag with 3 units.

Laboratory Catalogue 2004 Catalogue 2004 1st Edition 1st Edition 128 129

Peristaltic pump 86 90, optional peristaltic pump. Separate element, can be connected to TitroMatic 1S and 2S.

86 91, TitroMatic pump cassette Counterweight “Pharmed” tube, internal diameter 2 mm. Flow-rate 70 ml/min. This is the standard Supports cassette for pumps which serve TitroMatics. 91 59, support for sensors with . 90 82, TitroMatic pump cassette 91 60, support with magnetic stirrer and vessel for “Novoprene” tube, internal diameter 3.2 mm. Flow rate KF titration. 170 ml/min. The differences over the previous one are: This is handy when above-standard flow rates are required. - The vessel fits in the cap, thus ensuring that it is water-, dust- and airtight. - The cap has a 20 mm-diameter hold for introducing samples without taking the vessel out.

91 52, support with rod stirrer (L = 70). For 120-ml. vessels. Includes counterweight to stabilise the set. The stirrer rod is 70 mm long.

91 54, support with rod stirrer (L = 105). For vessels up to 400 ml. Vessels and tubes The stirrer rod is 105 mm long. 90 91, polypropylene vessel, 120 ml. Stirrers Supplied in bags with 100 units. 90 11, magnetic stirrer. Can be connected 91 40, Pyrex glass vessel, 120 ml. directly to Burette, MultiBurette, PH-Burette, 91 41, Pyrex glass vessel, 200 ml. and TitroMatic. 91 42, Pyrex glass vessel, for KF titration, 120 ml. Adapts to support 91 60. 90 12, rod stirrer (L=105). Can be connected directly to the TitroMatic. 91 39, Pyrex glass vessel, jacketed, 120 ml. Adapts to support 91 60.

92 74, “micro” tube, 10 ml. 91 69, rod stirrer (L=70). Made of polypropylene. Ø16 mm, for Sampler 45. Can be connected directly to Supplied in box with 25 units. the TitroMatic and Sampler 15. 92 75, centrifuge tube, 110 ml. Made of polypropylene. Ø40 mm, for Sampler 20. Supplied in box with 25 units.

92 76, Pyrex glass tube, 110 ml. 91 96, magnetic stirrer for COD Ø40 mm, for Sampler 20. tubes and electrode support. Special for final titration in 90 74, “Behr”-type tube, for COD. digestion tubes. Made of Pyrex glass, Ø40, height 200 mm, for Sampler 20.

Laboratory Catalogue 2004 Laboratory Catalogue 2004 1st Edition 1st Edition 128 129

Sensors: pH, metallic electrodes, etc. Corrugated gaskets See corresponding pages. Used to fix PTFE tubes in the electrovalve and also in the Syringes outlet joints for peristaltic These are Hamilton precision syringes. pumps for TitroMatics and The plunger head is made of PTFE. . Supplied in bags with 5 units 92 26, TLL syringe, 10 ml. 87 17, gaskets for 0.8 x 1.5 mm tube. 92 25, TLL syringe, 5 ml. 87 18, gaskets for 1.5 x 2.5 mm tube. 92 24, TLL syringe, 2.5 ml. 92 35, TLL syringe, 1 ml. Protective sheaths for PTFE tube “Salt Line” Syringes Protect the reagent from light, For highly saline reagents. PP plunger reinforce the tube and make it with polyethylene cap more visible. 92 29, TLL-SL syringe, 10 ml. Supplied in bags with 3 metres 92 28, TLL syringe, 5 ml. 92 27, TLL syringe, 2.5 ml. 87 30, 4 x 6 polyethylene tube, red 87 31, 4 x 6 polyethylene tube, blue Cylinders for fixing syringes Used to keep the syringes firmly in place. 87 32, 4 x 6 polyethylene tube, white They prevent fluctuations when the 87 33, 4 x 6 polyethylene tube, black plunger changes direction. 87 40, cylinder for 10 ml syringe. Miscellaneous 87 41, cylinder for 5 ml syringe. 87 00, PTFE and titanium filter, 87 42, cylinder for 2.5 ml syringe. 10-micra pore For inlet tube of reagent to burette. PTFE tubes Supplied in bags with 3 metres 87 16, antidiffuser device 87 12, 0.8 x 1.5 mm tube. For 1.5 x 2.5 mm. outlet tube 87 13, 1.5 x 2.5 mm tube. 90 55, electrode cable with BNC connector For pH, metallic and KF titration electrodes. Joint for fixing PTFE tubes Used in combination with corrugated gaskets. This prevents the classical stretching of teflon tubes. 91 08, plug-in power supply for Burettes and TitroMatic. Input voltage 230 VAC. 91 09, plug-in power supply for Burettes and TitroMatic. Input voltage 115 VAC.

87 60, conical adaptor NS Supplied in bags with 5 units. 14/23 For adapting sensors to 87 14, joint, R6 screw, for 0.8 x 1.5 mm tube. the holes in the lid of 87 15, joint, R6 screw, for 1.5 x 2.5 mm tube. the different support models. 87 25, conical joint for fitting 0.8 x 1.5 mm tube in the lid of the flexible support. 92 49, electrovalve. Spare part for Burette, 87 26, conical joint for fitting 1.5 x 2.5 mm tube MultiBurette, PH-Burette and TitroMatic. in the lid of the flexible support.

Laboratory Catalogue 2004 Laboratory Catalogue 2004 1st Edition 1st Edition