DOOR CONTROL AND SECURITY HARDWARE Table of Contents

StrikeForce Electric Strikes ...... 4-14 Series 6000 Electric Strikes...... 4-14 Strikes for Rim Exit Devices ...... 5-6 Strikes for Mortise and Cylindrical Locks ...... 7-11 5100 Electric Strike ...... 12 Compatibility Charts ...... 13 Additional Information ...... 14 Electrical Accessories ...... 15-29 ALK Exit Alarm Kit ...... 29 Electric ...... 23 Electric Mullions...... 29 Electrical Power Transfers ...... 25 Exit Devices—Chexit Delayed Exit...... 19 Exit Devices—Electrical...... 15-16 Exit Devices—Monitoring ...... 17-18 Exit Trim - Computer Managed ...... 21-22 Junction Box ...... 25 Monitor Strikes ...... 26-28 Power Supplies ...... 24 Pushpad ...... 20 Additional Information Handing of ...... 30 Wire Size Selection...... 30

3 Series 6000 Electric Strikes

Electric Strikes provide remote release OPTIONS Optional of a locked . They allow the door AC Operation Latchbolt to be opened without retracting the Position SO12 and SO24 are rectifier kits to Tripper latchbolt. This occurs by the releasing of convert AC voltage to operate the the electric strike lip (sometimes called DC solenoids. These kits are field keeper or gate). When the door closes installable and plug in-line to solenoid. the beveled latchbolt rides over the lip Wire Connector and falls into the electric strike pocket. DS and DS-LC — Dual Switch Monitoring (Factory Installed Only) VON DUPRIN SERIES 6000 Dual switch monitoring option has two ELECTRIC STRIKES Lip SPDT contacts, one switch monitors (keeper) Von Duprin is the leading manufacturer the tripper which is depressed when of premium, heavy duty electric strikes. the latchbolt is inserted into the strike Known for their reliability, durability and pocket. The second switch monitors Faceplate security 6000 Series strikes feature all the condition of the strike lip, open or Back stainless steel construction, are non- closed and locked. Box handed and available in 12V or 24V, DC Two switch options are available or AC. Strikes are furnished fail secure — DS and DS-LC. (FSE) standard, with fail safe (FS) DS is standard, rated 24V, operating optional. Strike box is adjustable to range from 2 ampere to 50 milliampere. Solenoid compensate for any misalignment of the door or frame. Two-piece plug DS-LC low volt gold contact switches UL LISTED connectors are furnished for ease of for use on applications associated with UL Listed Burglary-Resistant and Electric installation and for removal during computer control and monitoring, rated Strike for fire doors and frames. A label strike servicing. 24V, operating range 50 milliampere for single doors and B label for double or below. To assure the proper selection of an doors. Strikes are tested in accordance electric strike on new applications, Fail Secure — FSE with BHMA Standard 501 and ANSI compatibility charts are shown FSE — FAIL-SECURE electric strikes 156.5, Grade 1, 1984. on page 13. When using a lockset not require power to be applied to unlock the TO ORDER, SPECIFY listed or when retrofitting a strike to an strike lip. On loss of power, the strike is 1. Model number existing application, consult Von Duprin locked. Field convertible. 2. FS (fail safe, when required) for application assistance. Fail Safe — FS 3. DS or DS-LC (dual switch, when FS — FAIL-SAFE electric strikes require required) power to be applied to lock the strike lip. 4. Voltage 12VDC or 24VDC On loss of power, the strike is unlocked. 5. SO12 or SO24 (required when using Building codes prohibit the use of AC) fail-safe strikes on labeled openings. 6. Finish Field convertible. 7. Entry buzzer, FSE only (when required) Entry Buzzer — EB EB — Entry buzzer is available for use with fail-secure strikes. Installed in the frame and in parallel with the circuit, the buzzer will sound when the strike is Note: Information listed is for use on new unlocked. applications. On retrofit applications, modification of the frame preparation may be required, consult factory.

4 6111, 6112, 6113 Electric Strikes

6111 FEATURES Electric strike for use with rim exit • All Stainless Steel Construction 3 devices on single doors or double doors • Accepts ⁄4˝ (19mm) Throw Latchbolt with mullion applications (hollow metal, • Six Finishes aluminum or wood). Designed to replace • Non-handed Von Duprin 3031. 55-ENGR no charge. • Fail Secure • Horizontally Adjustable 6112 • Plug Connectors Electric strike for use with rim exit devices on single door applications OPTIONS (hollow metal, aluminum or wood). • Fail Safe Designed to replace Folger Adam 310-4, • Dual Monitor Switches 6111 minor frame prep required. • Entry Buzzer 6113 6111/6113 ELECTRIC STRIKE Electric strike for use with rim exit BLADE STOP SHIM 010055-XX devices on single door applications (hollow metal, aluminum or wood), 1 Use on cased opening ⁄2˝ (13mm) stop or greater. Designed to or blade stop frame. 1 replace Von Duprin 3011 and 3021. ⁄2" (13mm) aluminum, not for fire door application.

6112

6113

SPECIFICATIONS 12V 24V Resistance in Ohms±10% @ 70°F 21 72 UL listed Burglary Resistant Watt-seated @ 70°F 7.5 8 CVXY and Electric Strike for fire Amps-seated @ 70°F .6 .33 doors or frames GXAY (fail secure only). ANSI E59311 Amps-inrush @ 70°F .6 .33 Listing applies to Von Duprin rim devices.

DIMENSIONS AND CONFIGURATIONS 6111 6112 6113

3 7 15/8" /4" ⁄8" 1/2" (41mm) 15/8" (19mm) (22mm) (13mm) 5 15/8" 1 /8" 15 (41mm) 9/16" 1 ⁄16" (41mm) (41mm) (14mm) (49mm)

6" 3 1 (152mm) 2 /16" 4 /2" 1 1 (56mm) (114mm) 4 /2" 6" 21/4" 4 ⁄2" 9" 29/16" (114mm) (152mm) (114mm) (229mm) (65mm) (57mm) Minimum Clearance 13/8" 5 3 (35mm) 1 /8" 1 ⁄8" (41mm) (35mm) Minimum 7/8" Minimum 7 Clearance (22mm) 13/16" Clearance /8" 7 (21mm) /8" 9/16" (22mm) (22mm) (14mm)

5 6114, 6121 Electric Strikes

6114 FEATURES Electric strike for use with rim night • All Stainless Steel Construction 3 3 latches having up to ⁄4˝ (19mm) bolt • Accepts ⁄4˝ (19mm) Throw Latchbolt throw. Replace Folger Adam 310-5. • Six Finishes • Non-handed 6121 • Fail Secure Electric strike for use with rim exit • Horizontally Adjustable devices on double door applications, • Plug Connectors without mullion (hollow metal, aluminum or wood). Strike mounts on inactive leaf. OPTIONS Replace Folger Adam 310-4-100. • Fail Safe • Dual Monitor Switches • Entry Buzzer

SPECIFICATIONS 12V 24V 6114 Resistance in Ohms±10% @ 70°F 21 72 Watt-seated @ 70°F 7.5 8 Amps-seated @ 70°F .6 .33 Amps-inrush @ 70°F .6 .33 6121

UL listed Burglary Resistant CVXY. DIMENSIONS AND CONFIGURATIONS ANSI E59371 6114 6121

1 2 ⁄2" 7 1 ⁄16" (64mm) (37mm)

7 ⁄8"

3 (22mm) 3 ⁄32" 5 (79mm) 1 ⁄8" (41mm) 1 5 9 ⁄8" 1 ⁄8" (41mm) (232mm) 1 7 ⁄2" (191mm)

6 6210, 6211, 6211AL, 6211WF Electric Strikes

6210 6211WF Electric strike for use with mortise locks Electric strike for use on new without deadbolt on single door, hollow installations with mortise locks metal frame applications and using ANSI without deadbolt or cylindrical locks prep at standard height. Strike pocket on single door, wood frame applications. inserts are provided to accommodate Designed to replace Folger Adam 732. different manufacturers deadlocking FEATURES trigger locations. • All Stainless Steel Construction 3 6211 • Accepts ⁄4" (19mm) Throw Latchbolt Electric strike for use on new • Six Finishes installations with mortise locks • Non-handed without deadbolt or cylindrical locks • Fail Secure on single door, hollow metal frame • Horizontally Adjustable applications. Designed to replace • Plug Connectors 6210 Von Duprin 3140 or Folger Adam 712. OPTIONS 6211AL • Fail Safe 6211 Electric strike for use on new • Dual Monitor Switches installations with mortise locks • Entry Buzzer without deadbolt or cylindrical locks on single door, aluminum frame applications. Designed to replace Folger Adam 722.

6211AL SPECIFICATIONS 12V 24V Resistance in Ohms±10% @ 70°F 21 72 Watt-seated @ 70°F 7.5 8 UL listed Burglary Amps-seated @ 70°F .6 .33 6211WF Resistant CVXY and Amps-inrush @ 70°F .6 .33 Electric Strike for fire doors or frames GXAY (fail secure only). ANSI E59321

DIMENSIONS AND CONFIGURATIONS 6210 6211 6211AL 6211WF

19 15 1 ⁄16" 1 ⁄32" 1 15 15 1 ⁄4" 1 ⁄4" 1 ⁄32" 1 ⁄32" (38mm) (49mm) 1 1 1 ⁄4" (49mm) (32mm) 1 ⁄4" (32mm) (49mm) (32mm) (32mm) 1 3 11 11 4 ⁄2" 1 ⁄4" 1 ⁄16" 1 ⁄16" (44mm) (43mm) (43mm) (114mm)

3 7 7 8 3 ⁄8" 3 3 4 ⁄ " 4 ⁄8" 3 ⁄8" 3 ⁄8" 7 (124mm) (86mm) (124mm) 12" 4 ⁄8" 12" 7 3 (86mm) (86mm) 4 ⁄8" 3 ⁄8" 9 1 (305mm) (305mm) 3 ⁄16" 3 ⁄4" 1 (124mm) (86mm) 2 ⁄16" 1 (124mm) Minimum 2 ⁄16" Minimum (90mm) (83mm) 7 1 7 12" ⁄8" (52mm) 2 ⁄16" ⁄8" Clearance 7/89 (52mm) Clearance (305mm) (22mm) (52mm) (22mm) 1 (22mm) 3 1 ⁄4" 1 1 ⁄8" 1 ⁄2" 1 1 ⁄8" ⁄8" 1 ⁄4" 7 1 (32mm) 1 1 ⁄8" 1 Minimum (35mm) 2 (13mm) ⁄2" ⁄8" ⁄8" ⁄ " (3mm) (3mm) (32mm) Clearance (13mm) (13mm) (3mm) (22mm) (3mm)

7 6212, 6212WF Electric Strikes

6212 FEATURES Electric strike for use with mortise locks • All Stainless Steel Construction 3 without deadbolt or cylindrical locks on • Accepts ⁄4˝ (19mm) Throw Latchbolt single door, hollow metal or • Six Finishes aluminum frame applications. • Non-handed Fits modified ANSI 115.2 cutout. • Fail Secure Designed to replace Von Duprin 3146. • Horizontally Adjustable • Plug Connectors 6212WF Electric strike for use with mortise locks OPTIONS without deadbolt or cylindrical locks on • Fail Safe single door, wood frame applications. • Dual Monitor Switches • Entry Buzzer

Note: Strike pocket insert is furnished for Strike mounting tabs are furnished for use with Von Duprin 7500 mortise lock. use with modified ANSI 115.2 cutout. Tab can be machine screw mounted or 6212 welded in place.

6212WF

SPECIFICATIONS 12V 24V UL listed Burglary Resistant CVXY and Resistance in Ohms±10% @ 70°F 21 72 Electric Strike for fire Watt-seated @ 70°F 7.5 8 doors or frames GXAY (fail secure only). Amps-seated @ 70°F .6 .33 ANSI E59321 Amps-inrush @ 70°F .6 .33

DIMENSIONS AND CONFIGURATIONS 6212 6212WF

15 1 ⁄32" 1 15 1 ⁄4" 1 ⁄32" 1 (49mm) (32mm) 1 ⁄4" (49mm) 11 16 (32mm) 1 ⁄ " 1 (43mm) 4 ⁄2" (114mm)

3 3 ⁄8" (86mm) 3 3 9 3 6 ⁄8" 3 ⁄8" 3 ⁄16" 6 ⁄8" 12" (305mm) (162mm) (86mm) (90mm) (162mm) 1 2 ⁄16" Minimum 1 (52mm) Clearance 2 ⁄16" 7 (52mm) 7 ⁄8" ⁄8" (22mm) (22mm) Minimum 1 1 1 ⁄2" Clearance 1 ⁄2" ⁄8" 1 ⁄2" (13mm) ⁄8" (13mm) (13mm) (3mm) (3mm)

8 6213, 6214, 6215, 6216 Electric Strikes

6213 6216 Electric strike for use with mortise locks Electric strike for use with mortise locks without deadbolt or cylindrical locks on with deadbolt, 1˝ (25mm) throw, on single door, hollow metal or aluminum single door, hollow metal, aluminum or frame applications (includes wood frame wood frame applications. Deadbolt must on retrofit application). Designed to be manually operated. Designed to replace Von Duprin 3041, 3042, 3061 replace Folger Adam 310-3-1. and 3062. FEATURES 6214 • All Stainless Steel Construction 3 Electric strike for use with mortise locks • Accepts ⁄4˝ (19mm) Throw Latchbolt without deadbolt or cylindrical locks on • Six Finishes single door, hollow metal or aluminum • Non-handed 6213 frame applications. Designed to replace • Fail Secure 3 Folger Adam 310-2 ⁄4. • Horizontally Adjustable • Plug Connectors 6215 6214 Electric strike for use with mortise locks OPTIONS without deadbolt or cylindrical locks on • Fail Safe single door, hollow metal or aluminum • Dual Monitor Switches frame applications. Designed to replace • Entry Buzzer Folger Adam 310-2.

6215 SPECIFICATIONS 12V 24V Resistance in Ohms±10% @ 70°F 21 72 6216 UL listed Burglary Watt-seated @ 70°F 7.5 8 Resistant CVXY and Amps-seated @ 70°F .6 .33 Electric Strike for fire doors or frames GXAY Amps-inrush @ 70°F .6 .33 (fail secure only). ANSI E59321

DIMENSIONS AND CONFIGURATIONS 6213 6214 6215 6216

35 3 3 ⁄32" 2 ⁄16" 1 ⁄8" 1 3 4 1 ⁄8" (80mm) (56mm) 1 ⁄ " (35mm) 1 21/29 3 2" 1 ⁄2" (32mm) 1 ⁄8" (35mm) (64mm) (51mm) (38mm) (35mm) 7 5 2 ⁄8" 1 ⁄8" 5 1" 1 ⁄8" (73mm) (41mm) (41mm) (25mm)

3 8 9" 3 9" 3 5 ⁄ " 3 ⁄4" 3 ⁄4" 12" (305mm) 9" 7 1 (229mm) (229mm) (137mm) 3 ⁄8" 4 ⁄2" (95mm) (95mm) 3 1 6" 12" (305mm) Minimum (229mm) 3 ⁄4" 6 ⁄8" (98mm) (152mm) (114mm) 5 Minimum Clearance (95mm) (156mm) 1 ⁄8" 1" 5 3 Clearance 1 ⁄8" 1 ⁄8" 1" (41mm) (25mm) (41mm) (35mm) 5 1" (25mm) 1 ⁄8" (41mm) (25mm) 3 ⁄4" 5 5 Minimum Minimum 1 ⁄32" (19mm) 1 ⁄16" 1 1 1 5 1 ⁄16" 5 Clearance 1 ⁄4" ⁄4" Clearance 1 ⁄16" ⁄32" (4mm) ⁄32" (24mm) (32mm) (6mm) (17mm) (4mm) (17mm) (4mm)

9 6221, 6222, 6225 Electric Strikes

6221 FEATURES Open back electric strike for use with • All Stainless Steel Construction 3 mortise locks without deadbolt or • Accepts ⁄4˝ (19mm) Throw Latchbolt 3 cylindrical locks on 1 ⁄4˝ (44mm) thick • Six Finishes double door (hollow metal, aluminum • Non-handed or wood) applications. Designed to • Fail Secure replace Von Duprin 3071 and 3072. • Plug Connectors 6222 OPTIONS Open back electric strike for • Fail Safe use with mortise locks without deadbolt • Entry Buzzer 3 or cylindrical locks on 1 ⁄4˝ (44mm) thick double door (hollow metal or aluminum applications. Designed to replace Folger 6221 Adam 310-23/4 OB. No DS option for open backs (47˝ x 75˝ use “A” Backbox.) No extra charge. 6225 6222 Open back electric strike for use with mortise locks without deadbolt 3 or cylindrical locks on 1 ⁄4˝ (44mm) thick double door (hollow metal or aluminum applications. Designed to replace Folger Adam 310-2 OB.

SPECIFICATIONS 12V 24V Resistance in Ohms±10% @ 70°F 21 72 UL listed Burglary Watt-seated @ 70°F 7.5 8 Resistant CVXY and Electric Strike for fire Amps-seated @ 70°F .6 .33 doors or frames GXAY Amps-inrush @ 70°F .6 .33 (fail secure only). ANSI E59321 6225

DIMENSIONS AND CONFIGURATIONS 6221 6222 6225

1 1 2" (51mm) 1 1 ⁄2" (38mm) 1 2 ⁄16" (52mm) 2 ⁄16" (52mm) 1 ⁄4" (32mm) 1 4 ⁄2"

(114mm) 5 5 1 ⁄8" 1 ⁄8" Minimum (41mm) (41mm) 12" (305mm) 7 Minimum 1 ⁄16" Clearance 12" (305mm) 7 Minimum Clearance (37mm) 8 7 3 ⁄ " 3 ⁄8" Clearance 6" (98mm) 9" (98mm) 3 (152mm) (229mm) 5 3 ⁄4" 1 ⁄8" 9" 3 5 3 ⁄4" (95mm) (229mm) 1 ⁄8" (41mm) (41mm) (95mm)

1 1 1 ⁄4" ⁄4" (32mm) (6mm) 3 3 4 3 1 ⁄ " 1 ⁄8" 8 5 1 ⁄ " ⁄32" (4mm) 5 (44mm) (35mm) (35mm) ⁄32" (4mm)

10 6223, 6224, 6224AL, 6226 Electrical Strikes

6223 6226 Closed back electric strike for use with Closed back electric strike for use with mortise locks without deadbolt or mortise locks without deadbolt or 3 3 1 cylindrical locks on 1 ⁄4˝ (44mm) thick cylindrical locks on 1 ⁄4˝ (44mm) or 2 ⁄4˝ double door (hollow metal, aluminum or (57mm) thick double door (hollow metal wood) applications. Designed to replace or aluminum) applications. Designed to Von Duprin 3091 and 3092, mortise replace Folger Adam 310-2. 3 applications only — 4 ⁄4˝ (120mm) Not for wood applications. minimum stile required. FEATURES Not for wood applications. • All Stainless Steel Construction 3 6224 • Accepts ⁄4˝ (19mm) Throw Latchbolt Closed back electric strike for • Six Finishes use with mortise locks without deadbolt • Non-handed 6223 6224 3 or cylindrical locks on 1 ⁄4˝ (44mm) or • Fail Secure 1 2 ⁄4˝ (57mm) thick double door (hollow • Plug Connectors metal or aluminum) applications. OPTIONS 3 Designed to replace Folger Adam 310-2 ⁄4. • Fail Safe Not for wood applications. • Dual Monitor Switches 6224AL • Entry Buzzer Closed back electric strike for use with mortise locks without deadbolt 3 or cylindrical locks on 1 ⁄4˝ (44mm) or 1 2 ⁄4˝ (57mm) thick aluminum double door applications. Designed to replace Folger Adam 310-2RF.

6224AL

6226

SPECIFICATIONS 12V 24V Resistance in Ohms±10% @ 70°F 21 72 UL listed Burglary Resistant CVXY and Watt-seated @ 70°F 7.5 8 Electric Strike for fire Amps-seated @ 70°F .6 .33 doors or frames GXAY (fail secure only). Amps-inrush @ 70°F .6 .33 ANSI E59321

6223 6224 6224AL 6226

3 3 1 1 3 1 ⁄8" 2 1 ⁄4" 1 ⁄8" 1 1 ⁄8" 1 ⁄ " 1 1 ⁄2" (32mm) 4 ⁄2" (35mm) 2" (35mm) (35mm) (38mm) (114mm) (51mm) (38mm) 5 5 1 ⁄8" 5 1 ⁄8" 1 ⁄8" (41mm) (41mm) 3 9" (41mm) 1 ⁄8" (35mm) (229mm) 3 7 3 ⁄4" 3 ⁄8" (98mm) 3 9" 6" 7 3 ⁄4" 12" (305mm) 5 9" 3 ⁄8" 1 ⁄8" (95mm) 3 (229mm) 12" (305mm) 5 3 ⁄4" (152mm) (98mm) 1" (95mm) Minimum (41mm) (229mm) 1 ⁄8" 5 Minimum (95mm) 12" (305mm) 5 Clearance 1 ⁄8" (41mm) (25mm) 1 ⁄8" (41mm) Clearance Minimum (41mm) 1" (25mm) 1" Clearance Minimum (25mm) 1" Clearance (25mm) 3 1 ⁄4" 1/4" 5 32 5 11 ⁄ " 11 ⁄32" 5 (44mm) (6mm) ⁄16" ⁄16" 11 ⁄32" (17mm) (4mm) (4mm) ⁄16" (17mm) (17mm) (4mm)

11 5100 Electric Strike

5100 DURABILITY The Von Duprin 5100 Electric Strike Developed with Von Duprin’s high has been designed and manufactured standards and engineering expertise. to meet the needs of locksmiths and • Heavy-duty construction. security professionals. This easy-to-install • Tamper resistant design. electric strike was created for medium • Tested to over one million cycles. duty applications,specifically to control • 1300 lbs. holding strength. traffic flow through interior and exterior openings in retail and commercial FEATURES environments. And because it’s the • Three faceplates standard in every box Von Duprin brand, you know that you • 12/24 dual-voltage can depend on the product quality and • Fail-safe/fail-secure performance. • Adjustable keeper VERSATILITY • Internal solenoid Fewer products to inventory and more • Non-handed 11 value for your money. • Backbox depth of 1 ⁄16" 1 • Keeper depth of ⁄2" • Three faceplates included for hollow • Mounting tabs metal, wood or aluminum frames. • Retrofit kit • Internal 12/24 dual-voltage solenoid. • Illustrated installation instructions • Adjustable keeper. • Tamper resistant • Fail-safe/fail-secure selectability. • 1 year electrical product warranty CONVENIENCE • Continuous duty operation The right parts in the box means getting • Heavy duty construction the job done right the first time, every time. APPLICATIONS • Cylindrical locks • Reduce labor expense. • Aluminum dead • Fewer return trips to the job site.

SPECIFICATIONS 12V 24V Resistance in Ohms±10% @ 70°F 32 128 Power (watts) 4.5 4.5 Current (amps) .38 .19 All specs ± 10% @ 77°F/25°C ANSI/BHMA 156.5 Grade 1 UL 1034 Burglary Listing

5/32" radius on 4 corners

5/32" radius on 4 corners 1-1/16" 1-1/2" (Aluminum frame) 3-23/32" 1" 3-31/32"

2-7/16" 2-1/16" 1-11/16" 7-7/16" 1-11/16"

7-15/16" 4-7/8" C strike 4-1/8" L

3-3/8"

31/32" 3/32"

5/8" 1-1/4" 31/32" 23/32" CL Lock and strike 1-7/16"

CL Lock and strike

12 Electric Strike/Lock Compatibility Information

Chart 1 Chart 3 RIM EXIT DEVICE COMPATIBILITY CYLINDRICAL LOCK COMPATIBILITY 6111, 6112, 6113 & 6121 Strikes 6211, 6211AL, 6211WF, 6212, 6213, 6214, 6215, 6221, 6222, Manufacturer Device (panic/fire) 6223, 6224, 6224AL, 6225 & 6226 Strikes Von Duprin 22, 33, 35, 88, 98, 99 Manufacturer Cylindrical 1 3 Magnokrom Rim Baldwin ⁄2˝ – ⁄4˝ (13mm – 19mm) 3 3 Monarch* 11-R, XX-R, 18-R, 19-R Best ⁄8˝ – ⁄4˝ (10mm – 19mm) 1 3 Precision 810, 1100** Corbin ⁄2˝ – ⁄4˝ (13mm – 19mm) 1 3 Sargent 2800, 6500, 6800, 8500, 8800, Falcon ⁄2˝ – ⁄4˝ (13mm – 19mm) 1 3 9500, 9800**, 9898 Russwin ⁄2˝ – ⁄4˝ (13mm – 19mm) 1 3 Yale 1500, 7000, 7200 Sargent ⁄2˝ – ⁄4˝ (13mm – 19mm) 3 3 **Deadlocking feature will not properly function, consult factory. Schlage ⁄8˝ – ⁄4˝ (10mm – 19mm) 1 3 **Panic only. Yale ⁄2˝ – ⁄4˝ (13mm – 19mm) Note: Signalling may not function when using 3⁄8" (10mm) throw bolt. Chart 2 Deadlocking cannot be guaranteed with all locks. MORTISE LOCK COMPATIBILITY Chart 4 6211, 6211AL, 6211WF, 6212, 6213, 6214, 6215, 6221, 6222, MORTISE LOCK AND 6210 COMPATIBILITY 6223, 6224, 6224AL, 6225 & 6226 Strikes Von Duprin 7500 Manufacturer Mortise # Best 30H Von Duprin 7500 Corbin/Russwin ML2200, 5000, 9000 Adams Rite 4510, 4710 Falcon M100, M200, M300, M400, M500, Baldwin 6000 M600 Best 24H, 30H Sargent 7700, 8100 (Not 7800/8200) Corbin 9000 Schlage L9000 Falcon M2300, M2500, M2600 Yale 8700 M3300, M3500, M3600 Precision Mortise DC 24 V Blk 24 V Russwin Mortise 12 V Yel 12 V Sargent 7700, 8100, 9000 DC Schlage L9000, K30, K40, K50, K60 Supply J1 P1 Yale 7030, 7130, 8600, 8700 Solenoid Note: Von Duprin cannot guarantee compatibility as other manufacturer’s designs may change without notice. DC with Buzzer 24 V Blk 24 V AC 12 V Yel 12 V 24 V + Red 24 V Blk 24 V Wht – 12 V Yel 12 V Yel 12 V DC Buzzer Supply Wht J1 P1 AC Solenoid Supply J1 P1A J1A P1 Solenoid

So Kit Optional DS (FSE Shown) Wiring shown with strike locked and monitor tripper depressed AC with Buzzer 24 V Red 24 V + Blk 24 V Red Red Wht – Blue Blue 12 V Yel 12 V Yel 12 V S1 Wht Yellow Yellow

AC Buzzer White White Supply J1 P1A J1A P1 S2 Gray Gray Solenoid Violet Violet

So Kit Different wiring configurations are P2 J2 used depending on Backbox type and FS or FSE.

13 Additional Information

CROSS REFERENCE Frame Material Drop In Drop In Name Strike/Lock Mounting # Doors (SGL Dr) Faceplate Replaces Replaces Door Material Length Von Duprin: Folger Adam: (DBL Dr) 6111 Rim Device Single1 All 6˝ 3031 6112 Rim Device Single All 9˝ 310-44 6113 Rim Device Single All 6˝ 3011, 3021 6114 Rim Nightlatch Single All 7˝ 310-55 6121 Rim Device Double-Closed Back All 9˝ 310-4-1005 7 6210 Mortise Single HM/Alu 4 ⁄8˝ 7 6211 Mortise or Cylindrical Single HM/Alu 4 ⁄8˝ 3140 712 7 6211AL Mortise or Cylindrical Single Aluminum 4 ⁄8˝ 722 7 6 6211WF Mortise or Cylindrical Single Wood 4 ⁄8˝ 732 3 6212 Mortise or Cylindrical Single HM/Alu 6 ⁄8˝ 3146 3 6212WF Mortise or Cylindrical Single Wood 6 ⁄8˝ 6213 Mortise or Cylindrical Single All2 6˝ 3041, 42, 61, 62 6214 Mortise or Cylindrical Single All3 9˝ 310-2 3/4 6215 Mortise or Cylindrical Single All3 9˝ 310-2 6216 Mortise and Deadbolt Single HM/Alu 9˝ 310-3-1 6221 Mortise or Cylindrical Double-Open Back All 6˝ 3071, 72 6222 Mortise or Cylindrical Double-Open Back HM/Alu 9˝ 310-2 3/4 OB 6223 Mortise or Cylindrical Double-Closed Back All 6˝ 3091, 3092 6224 Mortise or Cylindrical Double-Closed Back HM/Alu 9˝ 310-2 3/4 6224AL Mortise or Cylindrical Double-Closed Back Aluminum 9˝ 310-2 RF 6225 Mortise or Cylindrical Double-Open Back HM/Alu 9˝ 310-2 OB 6226 Mortise or Cylindrical Double-Closed Back HM/Alu 9˝ 310-2

1Includes double door with mullion. 2Recommended on wood frames only if drop in replacement is needed for 3041, 42, 61, 62 on wood frames. Otherwise use 6211WF. 3Recommended on wood frames only if drop in replacement is needed for 310-2 3/4, 310-2 on wood frames. Otherwise use 6211WF. 4Strike lip area cutout is slightly larger than Folger Adam. 5Surface applied strike. Mounting hole locations different from Folger Adam. 6Wood frame horizontal solenoid location differs from Folger Adam. May require new frame prep when retrofitting.

FINISHES WIRE SIZE SELECTION US BHMA Description Von Duprin Current requirement at 24VDC Number Number Number Length of 0-.5 .5-1 1-2 2-3 US3 –– Plated Polished Brass 85 wire run (in feet) Amp Amp Amp Amp on Stainless Steel 0-100 18 18 18 18 US4 –– Plated Dull Brass on 84 100-200 18 18 18 16 Stainless Steel 200-300 18 18 16 14 US10 639 Plated Dull Bronze on 06 300-450 18 16 14 12 Stainless Steel 450-600 18 16 12 NR US10B 640 Plated Dark Bronze on 86 600-900 16 14 NR NR Stainless Steel 900-1200 14 12 NR NR US32 629 Stainless Steel, Polished 31 NR — Not recommended US32D 630 Stainless Steel, Satin 32

14 Electric Latch Retraction EL

The EL electric latch retraction feature provides remote unlocking ability to exit devices. The feature is available with 33, 35, 94, 95, 98 and 99 series EL33/EL35 devices, rim, mortise and vertical rod. A control station operator can flip a switch to retract the latch bolt and immediately change an exit only or latched door to push-pull operation. EL98/EL99 A powerful, continuous duty solenoid retracts the latch bolt…for momentary unlocking, or for extended periods of time, in lieu of manual dogging. EL94/EL95 EL devices are also useful with automatic door operators, and may Rim device shown — Refer to 33/35, 98/99 or 94/95 Series catalog for complete product be applied to fire-rated devices when information, mounting styles, outside trim, finishes, etc. under the control of an automatic fire alarm system. This feature does not include the power transfer from door to frame, nor the power supply or control operator. UL listed FVSR SA163 panic (Refer to page 25 for the EPT-2 electric Minimum Door Width: 3´ (914mm) hardware and/or GXHX R4504(N) power transfer, and to page 24 for the device–2´6˝ (762mm), 4´ (1219mm) fire exit hardware. Consult Device catalog for Fire Rated Models. PS-873 Power Supply). device–3´0˝ (914mm)

SPECIFICATIONS Resistance - New Style 1987 and after GRN-YEL 1.2-2 OHMS Solenoid GRN-ORN 135-150 OHMS Continuous Duty 24VDC Current Inrush (300 milliseconds) 16 amperes Current Holding Supplied with 3’ (914mm) Cable at the (33/35 + 98/99) 0.3 ampere hinge side of door. Current Holding (Inpact) 0.5 ampere Caution: Power supply must be a PS873-2 minimum.

To Power Supply

Solenoid Logic mod- ule

NOTE: Requirements for field wiring between door frame and Power Supply (See page 23). Up to 100 Ft. - 14 gage. Over to 100 Ft. - 12 gage.

15 Electric Device E

The E98/E99 electric rim device provides remote unlocking capabilities. A control station operator can flip a switch to lock or unlock the outside trim. The 24VDC solenoid assembly contains a SPDT (single pole double throw) signal switch E98/E99 to monitor the outside trim (locked or unlocked). A second switch monitors Rim device shown — Refer to 33/35 or 98/99 Series catalog for complete product the latchbolt position. information, mounting styles, outside trim, finishes, etc. The device is standard as fail safe (FS). When power is off, the trim is unlocked. SPECIFICATIONS UL listed FVSR SA163 panic hardware and GXHX R4504(N) fire exit hardware. The trim may then be relocked Solenoid — 24VDC, 0.25 ampere electrically (by applying power). Each switch — rated 0.3 ampere, 24VDC The device is field convertible for fail Refer to page 25 for power transfers and secure (FSE) applications. page 24 for power supplies. The outside trim cylinder retracts the latchbolt for mechanical override.

Note: Some Fire codes will require “Fail Safe” (FS) operation for stairwell doors. Be sure to specify the correct operation for your application. Supplied with 3’ (914mm) Cable at the hinge side of door.

S1-LATCHBOLT MONITOR SWITCH S2-TRIM MONITOR SWITCH

BLACK WHITE SOLENOID

BLACK WHITE BROWN ORANGE GREEN BLUE YELLOW RED

1 1 1 RED 2 S1 2 2 YELLOW 3 3 3 BLUE 4 4 4 GREEN S2 5 5 5 ORANGE 6 6 6 BROWN FAIL SAFE FAIL SECURE

WIRING SHOWN WITH TRIM LOCKED AND LATCHBOLT EXTENDED

16 Signal Switch RX and LX

The RX (request to exit) signal switch feature is used to signal the use of an opening from the push side. When the LX33/LX35 push pad is depressed, the switch is RX33/RX35 activated. These devices are equipped with an internal SPDT (single pole double throw) switch which monitors the touch bar. LX98/LX99 RX98/RX99 The LX (latchbolt monitoring) signal switch monitors both egress and Rim device shown — Refer to 33/35 or 98/99 Series catalog for complete product access of an opening. When the latchbolt information, mounting styles, outside trim, finishes, etc. is retracted, the switch is activated. These devices are equipped with an SPECIFICATIONS UL listed FVSR SA163 panic hardware internal SPDT (single pole double throw) and/or GXHX R4504(N) fire exit hardware switch which monitors the latchbolt Switch rated 10 amperes @ 24VAC/ — consult device catalog for complete position. DC resistive device listing information. The device can be connected to a When used with inductive or capacitive loads, switch capacity will deteriorate. security console, or may be used as a single door alarm, when used with a horn and power supply. A continuous current electric transfer must be used for transferring power from the frame to the door.

Most other electrical functions (EL, E) Supplied with 3´ (914mm) Cable at the may be combined with the RX or LX hinge side of door. feature. RX and LX switches are available for factory or field installation. Blue Blue Gray Gray

Red Red White White

Yellow Yellow Violet Violet

RX Switch 3' (914mm) Cord LX Switch 3' (914mm) Cord

17 Signal Switch SS

The SS signal switch feature is used to signal the unauthorized use of an opening. Available in rim, mortise and SS33/SS35 vertical rod, these devices are equipped with two internal SPDT (single pole double throw) switches. One switch monitors both the touch bar and the latch bolt assembly, making the latch SS98/SS99 bolt tamper resistant, for positive security. An additional SPDT switch is Rim device shown — Refer to 33/35 or 98/99 Series catalog for complete product 1 connected to the 1 ⁄4˝ (32mm) mortise information, mounting styles, outside trim, finishes, etc. cylinder (cylinder not furnished) for alarm “bypass” (momentary Minimum Door Width: 3´ (914mm) UL listed FVSR SA163 panic hardware switch — not time delay). device–2´6˝ (762mm), 4´ (1219mm) and/or GXHX R4504(N) fire exit hardware — consult device catalog for The device can be connected to a device–3´0˝ (914mm) complete device listing information. security console, or may be used as a single door alarm, when used with a horn and power supply. A continuous Actual device length will vary depending current electric transfer must be used on device type, strike being used, stop for transferring power from the frame height, single or double door, etc. to the door. SPECIFICATIONS SS mortise lock devices are furnished Each switch rated 0.5 ampere 24VDC with both signal switch device and SS7500 mortise lock, total of four switches. The SS7500 mortise lock has the versatility and advantages of the 7500 lock with the addition of signalling functions to monitor latch bolt operation and trim locking function. Supplied with 3´ (914mm) Cable at the hinge side of door. Emergency Exit Push to open and sound alarm.

Blue

Red

Blue Yellow

Red Gray Green

Yellow White White

Violet Black Latch Bolt Switch Key Cylinder 3' (914mm) Cord Switch

18 Chexit® Controlled Exit Device

Rim device shown — Refer to Chexit Catalog for complete selection information.

Chexit Controlled Exit Device Series Electrical Specifications Key Switch — The Key Switch provides CX98 and CX99 are designed for use on Voltage — 24VDC the means to arm, disarm, or reset the Accident Hazard or Fire Exit Hardware Current — .4 amperes with 300 Chexit. The key can be removed in either applications and combines life safety millisecond 16 ampere in-rush on the Arm or Disarm position. with the needs of security and meets all arming External alarm contact — Indicator Lamp — The status of the requirements of NFPA 101® for “Special 1 ampere @ 24VDC Chexit can be determined by the Locking Arrangement” and UBC “Special Fire alarm input, external inhibit input, Indicator Lamp. When the lamp is off, Egress-control Devices”. door position input — setup for normally indicates disarmed and is functioning as closed contacts This exit hardware device will keep an a normal exit device. A slow flashing exit door secured for a 15 second period, FEATURES lamp indicates armed. A fast flashing yet tied into the fire alarm system will Request to Exit Switch is built in to indicator lamp indicates the device is in release immediately when an alarm detect when someone attempts to exit. alarm. condition exists. All controls, auxiliary Applying less than 15 pounds to the Internal Horn — Whenever the device is locking, local alarm, and remote pushpad will cause this switch to start an in alarm or the pushpad is pressed the signaling output are self-contained in irreversible alarm cycle. internal horn will sound. The volume the Chexit assembly, providing safe, Nuisance Alarm — If the Nuisance level of this horn exceeds 85 db at 6 feet. secure and easy to install door Audible and Nuisance Delay options are control hardware. Door Position Input — An external door set to off, the device will go into alarm as position switch can be connected to the Chexit system is ideal for highly soon as the pushpad is touched. Turning Chexit. The door position switch will controlled areas such as airports, the Nuisance Delay on will require the cause the alarm to sound if the door is hospitals, government facilities, pushpad to be pressed for 2 seconds not closed when the device is armed. computer rooms, research and before the Chexit goes into alarm which development labs, retail stores, libraries is ideal in public areas. If the Nuisance External Inhibit Input — This optional and security facilities. Audible and Nuisance Delay are both on, input is provided to allow remote over- • Non handed the alarm will sound as soon as the ride of the Chexit in the armed condition. • Field sizable pushpad is pressed, but the alarm It also allows remote reset of the Chexit 3 • ⁄4˝ (19mm) throw, latchbolt sequence will stop unless held for in an alarmed condition. • Deadlocking 2 seconds or more. Fire Alarm Input — This input disables Models are available for rim, mortise Remote Alarm — A set of relay the Chexit immediately upon a fire alarm. lock, surface vertical rod and concealed contacts (rated 1 ampere, 24VDC) Internal Auxiliary Lock —The Auxiliary vertical rod mounting styles. UL listed are provided to give external alarm Lock is engaged when the Chexit is for use on panic or fire exit doors, indication. These contacts close when armed. The locking mechanism is specif- 3´ or 4´ wide. the device is in an irreversible alarm ically designed to hold securely even condition. These contacts can be used A complete system requires a power when the exit device is struck with force- to drive a horn, lamp, or other supply and a power transfer. ful blows. indicative device. Finishes — US3, US4, US10, US26, US26D, US28, US32D and 313.

19 RX330 and RX350 Pushpad

The 330TBSK and 350TBSK bar with TBSK330 active pushpad with monitoring switch or “request to Exit” switch, used to inhibit alarms for authorized exiting. The 330 Yellow grooved outer case and the 350 smooth outer case are designed as companion Red units for Series 33, 35, 98 and 99 exit Supplied with 3´ (914mm) cable at the devices. Blue hinge side of door. The internal SPDT switch should not be used to control a load, but as a signaling switch. Two sizes are available 3´ (914mm) and 4´ (1219mm); 3´ (914mm) unit for door widths 2´6˝ (762mm) to 3´ (914mm), and 4´ (1219mm) unit for door widths 3´1˝ (940mm) to 4´ (1219mm). Electrical Rating SPDT 10 ampere @ 24VDC

20 CM993 and PRO993 Exit Trim

The Von Duprin Computer Managed Easy to Retrofit... Easy to Operate and CM993 exit trim is a stand-alone, Architecturally Designed for New battery-powered exit trim for use on Construction doors where an exit device is required • Directly retrofits existing trim for egress. The CM993 is designed to 3 1 • Fits doors from 1 ⁄8˝ to 2 ⁄4˝ thick be used with Von Duprin 98/99 exit 1 devices for unmatched • Comes with Schlage Everest 1 ⁄4˝ and ease of use. It can be programmed cylinder, but can adapt to other with LockLink™ or LockLink™ Express existing key systems access control management software. • LockLink™ software that programs The same software can also manage the the locks is Windows®-based and Schlage CM Locks and the Locknetics menu-driven. It can be operated Universal Controllers, which provide with minimal training intelligent access control for electrified CM993 Exit Trim or battery-powered products such as magnets, strikes and cabinet locks. Multiple users, Multiple access points. Multiple credentials. One way to manage them. Provides Unmatched Access Control • Manages up to 1,000 users and For use with VonDuprin 98/99 Series Exit Devices including Rim, Surface Vertical, Concealed Vertical and Three-Point latching models. (Not for use with mortise devices.) provides audit trail for last 1,000 events • SmartTime feature allows for time functionality: – time zones Conversion to New Card System – time schedules Not Necessary – holiday overide periods • Our exit device trims most likely work – first person in with your existing mag card and HID – credential activation and expiration prox cards Programmable PRO993 Exit Trim for • Full-swipe mag stripe card reader for Manual Programming maximum readability and reliability • Manually program up to 120 keycodes right at the trim • Optional audit trail of mechanical key override • Similar mechanical features as CM993 • Auto card updating feature which • Complements Schlage PRO and Locknetics PRO Series products disables a lost or stolen mag stripe card when the reissued card is presented at the lock • LED status indicators

21 How To Order Exit Trim

CM993 – MGK – 06 – LH – KD – 695 – EXT Select Model Select Access Credential Option Select Lever Select Handing Select Key Cylinder Option Select Finish Select Trim Options

1. Select Model 5. Select Key Cylinder Option

CM993 Computer 993-DT Dummy trim for inactive KD Schlage Everest Cylinder Note: Master keyed managed exit trim leaf LC Less Cylinder cylinders order separately

PRO993 Manually 993-BE Blank escutcheon programmed exit trim 6. Select Finish

2. Select Access Credential Option (CMs only) 605 612 613 625 626 695 Bright Satin Oil Bright Satin Duranodic Brass Bronze Rubbed Chrome Chrome Dark Bronze (Standard) Bronze

7. Select Trim Options KPI IBO MGK Keypad iButton iButton Reader Mag Card ATK Audit trail of mechanical key override, includes Reader Reader Keypad ATR (Requires computer programming) iButton Reader T3 ABA Track 3 Mag Card Reader (ABA Track 2 is standard for MGI and MGK Series only) EXT Mag Card Reader for exterior use (for MGI and MGK Series only) Door Thickness State door thickness. Available from 3 3 1 1 ⁄8" to 2 ⁄4" in ⁄8" increments MGI PXK PXI EG Exterior Gasket for PRO993 only Mag Card Reader HID prox Reader HID prox Reader iButton Reader Keypad iButton iButton Reader Reader Select Credentials 3. Select Lever IBA iButton (adhesive backed) IBF iButton on Fob MAG1 Magnetic Stripe Card – Blank MAG2 Magnetic Stripe Card – Pre-encoded PRX1 Prox Card – Standard .070" thick PRX2 Prox Card – Adhesive backed for photo 06 (Standard) 03 17 application, .070" thick PRX3 Prox Card – ISO – credit card size and 4. Select Handing thickness, .031" thick PRX4 Prox Card – Dual Technologies, magnetic RH Right Hand stripe and Prox, .031" thick LH Left Hand PF1 Prox Fob Note: Handing is field-reversible

22 Electric Mortise Lock E7500

The E7500 electric mortise lock for use FEATURES with 55, 88, 98 and 99 series has all the • Field reversible versatility and advantages of the 7500 • 24VDC continuous duty solenoid mortise lock plus the advantage of being • Tamper resistant electrically controllable by a remote • Corrosion resistant switching device, an access control or • Internal solenoid automatic fire alarm system. The E-7500 OPTIONS controls the locking of the outside trim. • Fail safe (locked when energized, When unlocked, the door remains • unlocked when de-energized or during latched, preserving the fire rating of the power failure specify with suffix “FS”). door and making it particularly useful • Fail secure (unlocked when where codes permit locking, but require energized — specify with suffix unlocking during a fire emergency. “FSE”). Outside trim automatically E7500 features a signalling function to relocks, unless held unlocked electri- monitor the latch bolt and trim locking cally. function. • 24VAC (includes SO option). UL listed FVSR SA163 panic hardware 1 • 12VDC or 12VAC (includes SO option). and GXHX R4504(N) fire exit hardware. 1 ⁄4˝ (32mm) mortise cylinder with SPECIFICATIONS straight cam (not furnished) unlocks Note: Some Fire codes will require “Fail Safe” (FS) operation for stairwell doors. Be Solenoid — 24VDC, .3 ampere, trim, trim locks when key is removed. Key retracts latch bolt. sure to specify the correct operation for your Continuous Duty application. Solenoid — 12VDC, .6 ampere, Continuous Duty

TO ORDER Refer to device catalog section for complete product information (type, function, finish, etc.)

Switches shown with trim locked Wiring at latch side of door. and latch bolt Wiring deadlocked. J2 P2 Blue Red Solenoid Yellow Gray White Latch Bolt Violet

11/4" Black 24V 41/2"▲ 1 Yellow 12V 7 /4" (32mm) (114mm) J1 White P1 (184mm)

P1A J1A 23/4" (70mm)

Black 24V *Optional — Required when Yellow 12V operated on AC. Available SO* in 12 and 24 volt versions. (Must be specified when ordering) 8" ET500 shown. (203mm) SS7500 includes only J2/P2 connectors and wiring

s413/169 (122mm) clearance required for wiring.

23 Power Supplies

SERIES PS861 SERIES PS873 873-AO, Auto Operator function The series PS861 power supply The series PS873 power supply is coordinates the release of one or two is designed for electromagnetic locks designed to operate a wide variety locks and signals an auto-operator to and electric strikes on single door of electrical products. EL panics require open a door. Signaling the auto operator applications. The output power is field 871-2 PCB minimum. The regulated can be performed in two methods; by selectable for either 24VDC @ 1 ampere output power is field selectable for either receiving a signal from a monitoring or 12VDC @ 2 ampere. Standard input 24VDC @ 2 ampere or 12VDC @ 4 switch that the lock is unlatched, or upon 120VAC @ 0.6 ampere and 240VAC @ ampere. Standard input 120VAC @ 1.0 expiration of a time delay triggered by a 0.3 ampere available. Terminal block ampere or 240VAC @ 0.5 ampere “RX” type input switch. Use suffix “-AO” will accept up to 14 gauge stranded wire. available. for factory installed.

1 Enclosure is 10˝ high x 12 ⁄2˝ wide x 5˝ deep (254mm x 323mm x 127mm), gray with a hinged cover and constructed of heavy 19 gauge steel. 1 3 Five ⁄2˝ x ⁄4˝ (13mm x 19mm) knockout holes are provided for conduit connection. Terminal block will accept up to 12 gauge wire.

1 The PS873 can be ordered with three Enclosure is 10˝ high x 12 ⁄2˝ wide x 5˝ 873-SI, Security/Safety Interlock deep* (254mm x 323mm x 127mm), standard options: Key lock secures provide interlock function for two zones. gray with 1 hinged cover and the cover to eliminate tampering and When combined with a second 873-SI constructed of heavy 19 gauge steel. provides safety; Battery backup provides card, the inter-locking of groups are 1 Six ⁄2˝ (13mm) knockout holes are two hours backup power at full load available in two, three or four zones. provided for conduit connection. during a A.C. power failure; Fire Alarm Safety interlock is available, consult provides input for a normally closed factory for additional information. Options include keylock cover and fire alarm contact. When the fire alarm Use suffix “-SI” for factory installed. sealed lead acid battery pack. The pair of contact is “open”, power to locks or batteries will provide back-up power for 873-4TD, Four Zone controller with other component is removed. Restoring three hours at full load or seven hours Time Delay provides four inputs and power is field selectable for automatic at half load. Batteries will automatically four outputs with time delay. Time delay or manual. recharge when failed power is restored. is field selectable from 0 to 75 seconds, Not appropriate for CX or EL devices. Eight standard configurations: in intervals of 5 seconds. Use suffix PS873 Standard “-4TD” for factory installed. FOUR CONFIGURATIONS PS873K With keylock PS861 Standard supply 873-AC, Access Control provides PS873B With battery PS861K Standard supply with supervision of one zone using an PS873BK With battery and keylock keylock cover . Input signals PS873FA With fire alarm PS861B Battery backup required are: access control contact, PS873K-FA With keylock and fire alarm PS861BK Battery backup and motion detector contact, and motion PS873B-FA With battery and fire alarm keylock cover detector override contact. FA, Fire Alarm PS873BK-FA With battery, keylock option is required. Use suffix “-AC”. * Standardized enclosure shipping and fire alarm Mid-January, 2003. The series PS873 is available with Factory Installed Only Circuit Cards: several optional circuit cards to 873-DE, Delayed Egress function ideal provide system flexibility. The power for use with electromagnetic locks, will supply will accept one or a operate two zones simultaneously. combination of any two cards. To operate two separate zones, a second 873-DE card is required. Factory or Field Installed Circuit Cards: UL listed component, when used as 871-2, Two Zone controller provides two part of a Von Duprin delayed egress inputs and two outputs. Use suffix “-2” system. Use suffix “x DE”. for factory installed. Will operate one or two EL exit devices. 873-AL, Alarm function monitors 1 or 2 zones and provides alarm output, upon detecting a door in the open position. Delayed alarming is selectable from 5 to 75 seconds. Use suffix “-AL” for factory installed. 24 Accessories Electrical Power Transfer Electric Power Transfer provides FINISHES a means of transferring electrical power SP28 (sprayed aluminum) and SP313 from a door frame to the edge of a (sprayed duranodic) swinging door. The units are completed SPECIFICATIONS concealed when the door is in the 7 1 Housing — 9" x 1 ⁄16" x 1 ⁄2" closed position, and are ideally suite for installations involving abuse or (229mm x 37mm x 38mm) heavy traffic. EPT-2 — Two 18 gauge wires Rating, 24VDC 2 Two models are available; EPT-2, two 18 amperes, 16 amperes gauge wires and EPT-10, ten 24 gauge maximum surge wires. EPT-10 — Ten 24VDC 1 ampere Door applications; up to 5" butt 1 hinges — 180° swing, 5 ⁄2" butt hinges — 130° swing, 6" butt TO ORDER, SPECIFY: UL Listed as “Miscellaneous” Fire Door 3 1. EPT-2 or EPT-10 Accessory” GVUX hinges — 110° swing, and ⁄4" offset pivots 180° swing. 2. Finish, SP28 or SP313

Junction Box High quality NEMA 1, junction boxes Five models: provide convenient installation, available JB7 Junction box only. in three models. These surface mounted units are 10˝ (254mm) high, 10" JB7-R1 Junction box with SPDT Relay. (254mm) wide and 6˝ (152mm) deep JB7-R2 Junction box with DPDT Relay. and includes hinged door with twist JB7-R3 Junction box with DPDT Relay turn lock. 24 position terminal strip on Make Relay. will accept from 24 to 12 gauge wire. JB7-R4 Junction box with DPDT Relay on Brake Relay.

25 Monitor Strikes

Monitor Strikes replace the standard SPDT Switch — The monitor switch box strike and add a TRIPPER that is is supplied SPDT (single pole double depressed when the latchbolt is fully throw), rated 24VDC @ 2 amperes inserted in the strike. The tripper is (resistive). These contacts are shown stainless steel and activates an in the “secure” position. electric switch.

Tripper BASIC MONITOR STRIKE CIRCUIT

Indicating Lights Unsecure

Blue Blue Red Yellow Grn Signal Switch Faceplate Housing Secure

Monitor Strike

120 VAC Power supply same voltage Supply T1 T2 T3 as lamps with sufficient current capabilities ▲Tripper selection is based on the throw and shape of the latch bolt.

Blue FINISHES Red Yellow US3, US4, US10, US10B, US26, US26D

Single Switch shown in secure position

Blue Red Yellow Blue Red Yellow

Double Switches shown in secure position

26 Series 4263, 4268t1, 4582

4582 Monitor strike for use with mortise or cylindrical locks on single or pairs of doors with ANSI A115.3 frame cutout (frame modification required). The one piece faceplate and body is constructed of drop forged brass. 4263 The tripper selection (-T1 or -T2) is 4263 based upon the lock to be used. See Monitor strike for use with rim or Chart below. surface vertical rod exit devices. Note: When used with Von Duprin 7500 The 4263 is non-handed and features mortise lock, strike handing is opposite horizontal adjustment to compensate device handing. for misalignment of door and frame. The faceplate is drop forged brass. 4268T1 4582 COMPATIBILITY CHART The tripper selection (-T1 or -T3) is UL listed (GXHX R4504) fire exit Von Duprin 7500 ML T1 hardware. 5 based upon the lock to be used with. Arrow ⁄8˝ (16mm) ML (LR) T2 See Chart below. Two 4263 strikes may 5 Corbin ⁄8˝ (16mm) ML (LR) T2 be used on 4754 mullion. 4268–T1 Single Doors Only - 5 Falcon ⁄8˝ (16mm) ML (LR) T2 (Not for Mullions) 5 COMPATIBILITY CHART Russwin ⁄8˝ (16mm) ML (LR) T2 Monitor strike especially for rim fire Von Duprin devices. The 4268 features horizontal 5000 ML (LR) T2 3 22 T3 adjustment to compensate for Schlage ⁄4˝ (19mm) Cyl. T2 2227 T1 misalignment of door and frame. L90 T2 5 33/35 T1 The faceplate is brass or cast stainless Yale ⁄8˝ (16mm) ML (LR) T2 3327/3527 T1 steel. The SPDT signal switch is rated 44 T1 at 24VDC @ 2 amps (resistive) and is 55 T1 actuated by a stainless steel tripper. 4582 88 T1 COMPATIBILITY CHART Top 8827 T1 22/22-F 98/99 T3 33/35 1 1/16" (27mm) 9827/9927 T1 88/88-F Monarch 98/99/98-F/99-F Rim (3/49 (19mm) throw) T3 4 7/8" (124mm) Yale 1 5/16" 1500 (5/89 (16mm) throw) T1 (33mm) 4268-T1 1 25/32" 3/32" 1 (45mm) /4" (2mm) 1" (6mm) 1 (25mm) 4263 1 5/8" 1 /8" (29mm) 1/4" (41mm) Caution: proper selection of handing required.

(6mm) Auxiliary 13/16" 6" bolt (152mm) 1 5/16" above Auxiliary (21mm) latch bolt 2 7/8" 1 5/16" (33mm) bolt below latch (73mm) (33mm) bolt LHR strike for RHR strike RHR strike LHR strike for LHR door. for RHR door. for LHR door. RHR door. 1" 13/16" (25mm) 1 1 5/8" (21mm) 1 /8" (41mm) (29mm)

27 4570-T1, 4670-T1

4570–T1 For use on single or double door applications with ANSI A115.2 frame cutout (frame modification required). See Chart below. 4570–T1 For use on single or double door applications with ANSI A115.3 frame cutout (frame modification required). 4570-T1 See Chart below. 4690-1-T2 COMPATIBILITY CHART Adams-Rite 4510 T1 8400 T1 Arrow 1/29 (13mm) Cyl. T1 4670-T1 Best 9/169 (14mm) Cyl. T1

Corbin 5/89 (16mm) Cyl. T1 UL listed (GXHX R4504) fire exit Dexter 7/169 (11mm) Cyl. T1 hardware, (4268T1 and 4582 only). Falcon 1/29 (13mm) Cyl. T1 9/169 (14mm) Cyl. T1 4690–T2 Kwikset 1/29 (13mm) Cyl. T1 Use on wide stile double door applica- 4690-T2 Lockwood 1/29 (13mm) Cyl. T1 tions. End Precision 1040 Auto. 4690–1–T2 Flush Bolt T1★ Use on narrow stile double door 1" Russwin 5/89 (16mm) Cyl. T1 applications. (Contains two SPDT (25mm) Sargent 1/29 (13mm) Cyl. T1 switches, one for each latchbolt). Schlage 1/29 (13mm) Cyl. T1 COMPATIBILITY CHART 3 1/4" 1 5/16" 5/89 (14mm) Cyl. T1 (83mm) (33mm) 4690 4690-1 Yale 1/29 (13mm) Cyl. T1 Von Duprin 3347-F — T2 ★ Special template required. 3 3347 3347 T2 1/4" /32" (6mm) (2mm) 9947 — T2 1 1/4" 1 25/32" 4570-T1 Top 9947F — T2 (32mm) (45mm)

13/16" (21mm) 4670 Top 4690-1-T2 End 4 7/8" 1 1/8" 13/16" (124mm) (29mm) (21mm) 1" 2 3/4" 1 1/8" (25mm) 7/64" (70mm) (29mm) 1 1/4" (3mm) 7 /64" (32mm) (3mm) 7/64" 17 1 5/16" 1 /32" 11/64" (3mm) 1 1 17/32" (39mm) (4mm) 1 /8" (33mm) (29mm) (39mm) 7 3 1/4" 2 /16" (83mm) (62mm) 1 5/16" (33mm)

3/32" 1 25/32" (2mm) (45mm) 1/4" (6mm) 1 1/4" (32mm)

28 ALK Exit Alarm Kit

The ALK battery alarm kit is a simple yet Alarm kits are available with a choice of The ALK includes “EMERGENCY EXIT effective way to monitor the use of an two switch kits, RX or LX. RX monitors ONLY. ALARM WILL SOUND” decal for exit device. While still a means of egress, the touchpad is furnished standard, application on door. the unit contains an internal horn, when LX optional latchbolt monitoring is PS9 POWER SUPPLY the touchbar is depressed, the horn recommended for use with surface PS9 power supply provides 9VDC to sounds to provide an audible means of vertical rod exit devices. Specify ALK-LX. power ALK alarm kits. The unit will signaling that the opening has been violated. The ALK can be used with all Von Duprin power one or two alarm kits. Included is 1 The key switch uses a standard 1 ⁄4" push pad devices. Choices include a 9 volt sealed battery for power backup (32mm) mortise cylinder. The unit 22ALK, 33/99ALK and 35/98ALK. in case of AC power failure. PS9 must be operates on one standard 9-volt transistor ordered separate. batteries. When batteries are weak the horn will emit an intermittent signal.

Mullions

Electrified removable mullions are 4854 — Prepared to accept 6111 used with pairs of doors equipped with electric strike on one side and 299 rim mounted exit devices. strike on other side. Each includes an electric cable with five 9854 — Prepared to accept 6111 conductors wired to a twist-apart plug. electric strike on one side and 499F The soffit fitting is supplied with a strike on other side. Can be used with 1 pre-wired mating socket. Von Duprin rim fire exit hardware, 1 ⁄2 hour rated doors up to 8809. UL listed 4754 — Prepared to accept two 4263 GXHX R4504. monitor strikes. Use with all Von Duprin rim panic devices. KR9854 keyed removable option available. Sizes for opening up to: 7´2˝ (2148mm), 8´2˝ (2489mm) or FINISHES STEEL MULLION 10´2˝ (3099mm) SP28 (Sprayed Aluminum) DIMENSIONS SP313 (Sprayed Dark Duranodic) 2" Sprayed Black WIRING

Red Yellow 3" Blue Black Black SOFFIT DETAILS 1" (25mm) Diameter Clearance Reinforcement Reinforcement

Filler block is to be supplied by the frame mgf. for conditions similar to this.

29 Additional Information

WIRE SIZE SELECTION Current requirement at 24 VDC 0–.5 Amp .5–1 Amp 1–2 Amp 2–3 Amp 0-100 (0-30) 18 18 18 18 100-200 (30-61) 18 18 18 16 200-300 (61-91) 18 18 16 14 300-450 (91-137) 18 16 14 12 450-600 (137-183) 18 16 12 NR 600-900 (183-274) 16 14 NR NR 900-1.200 (274-366) 14 12 NR NR

120 VAC SC I1 O1 I2 O2 GND EPT-2

EL #2 A Input #2 (Required for independent B operation only).

EPT-2

EL #1 A

Input #1 B

WIRE SIZE SELECTION EL Device w/EPT or Door Loop 0-100 ft 14 gauge 0-200 ft 12 gauge

WIRE SIZE SELECTION EL Device w/Electric Hinge/Pivot 0-150 ft 12 gauge 0-75 ft 14 gauge

HANDING OF DOORS

Left Hand Right Hand Orientation Orientation

LHR RHR (Left hand reverse) (Right hand reverse) Outside

30 Notes

31 DOOR CONTROL AND SECURITY HARDWARE

VON DUPRIN 2720 Tobey Drive, Indianapolis, IN 46219 317-613-8944 phone 371-613-8302 fax www.vonduprin.com www.irsecurityandsafety.com

© 2002 Ingersoll-Rand Form VD-GN-1009 Rev. 10/02 Printed in the U.S.A.