Serveraid M1210 SAS/SATA Controller for Lenovo System X User's Guide First Edition (April 2016) © Copyright Lenovo 2016
Total Page:16
File Type:pdf, Size:1020Kb
ServeRAID M1210 SAS/SATA Controller for Lenovo System x User's Guide First Edition (April 2016) © Copyright Lenovo 2016. LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant to a General Services Administration “GSA” contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No. GS-35F-05925. Contents Safety . iii Hardware service and support . 20 Safety statements . iv Taiwan product service . 20 Chapter 1. Product overview . 1 Appendix B. Notices. 21 M1210 controller description . 1 Trademarks . 22 Integrated MegaRAID . 2 Important notes . 22 Configuration scenarios . 3 Recycling information . 22 Benefits of the SAS interface . 4 Electronic emission notices. 23 Features and benefits of the M1210 controller . 5 Federal Communications Commission (FCC) Hardware specifications . 10 statement . 23 Industry Canada Class A emission compliance Chapter 2. M1210 controller statement . 23 installation . 11 Avis de conformité à la réglementation d'Industrie Canada . 23 Requirements . 11 Australia and New Zealand Class A Controller installation procedure . 11 statement . 23 European Union EMC Directive conformance Chapter 3. M1210 controller statement . 23 characteristics . 15 German Class A compliance statement . 24 Board layout and component information . 15 Japan VCCI Class A statement . 24 Characteristics of the M1210 controller . 15 Korea Communications Commission (KCC) statement . 25 Appendix A. Getting help and Russia Electromagnetic Interference (EMI) technical assistance . 19 Class A statement . 25 Before you call. 19 People's Republic of China Class A electronic Using the documentation . 19 emission statement . 25 Getting help and information from the World Wide Taiwan Class A compliance statement . 25 Web . 19 Software service and support . 20 © Copyright Lenovo 2016 i ii ServeRAID M1210 SAS/SATA Controller for Lenovo System x User's Guide Safety Before installing this product, read the Safety Information. Antes de instalar este produto, leia as Informações de Segurança. Læs sikkerhedsforskrifterne, før du installerer dette produkt. Lees voordat u dit product installeert eerst de veiligheidsvoorschriften. Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information. Avant d'installer ce produit, lisez les consignes de sécurité. Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. © Copyright Lenovo 2016 iii Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten. Buürünükurmadanöncegüvenlikbilgileriniokuyun. Safety statements These statements provide the caution and danger information that is used in this documentation. Important: Each caution and danger statement in this documentation is labeled with a number. This number is used to cross reference an English-language caution or danger statement with translated versions of the caution or danger statement in the Safety Information document. For example, if a caution statement is labeled Statement 1, translations for that caution statement are in the Safety Information document under Statement 1. Be sure to read all caution and danger statements in this documentation before you perform the procedures. Read any additional safety information that comes with your system or optional device before you install the device. Statement 1 DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: • Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. • Connect all power cords to a properly wired and grounded electrical outlet. • Connect to properly wired outlets any equipment that will be attached to this product. • When possible, use one hand only to connect or disconnect signal cables. iv ServeRAID M1210 SAS/SATA Controller for Lenovo System x User's Guide • Never turn on any equipment when there is evidence of fire, water, or structural damage. • Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures. • Connect and disconnect cables as described in the following table when installing, moving, or opening covers on this product or attached devices. Table for Safety Statement 1 that explains the steps to connect and disconnect cables. To Connect: To Disconnect: 1. Turn everything OFF. 1. Turn everything OFF. 2. First, attach all cables to devices. 2. First, remove power cords from outlet. 3. Attach signal cables to connectors. 3. Remove signal cables from connectors. 4. Attach power cords to outlet. 4. Remove all cables from devices. 5. Turn device ON. Statement 3 CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following: DANGER Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following: Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam. Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil A` Laser de Classe 1 Statement 8 © Copyright Lenovo 2016 v CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. Statement 28 CAUTION: The battery is a lithium-ion battery. To avoid possible explosion, do not burn the battery. Exchange it only with an approved part. Recycle or discard the battery as instructed by local regulations. vi ServeRAID M1210 SAS/SATA Controller for Lenovo System x User's Guide Chapter 1. Product overview This chapter provides an overview of the ServeRAID M1210 SAS/SATA Controller (hereafter referred to as M1210 controller). This chapter contains the following items: • “M1210 controller description” on page 1 • “Integrated MegaRAID” on page 2 • “Configuration scenarios” on page 3 • “Benefits of the SAS interface” on page 4 • “Features and benefits of the M1210 controller” on page 5 • “Hardware specifications” on page 10 M1210 controller description The M1210 controller is a PCI Express 3.0, low-profile, low-height RAID controller based on the LSISAS3004 PCI Express-SAS/SATA input/output (I/O) processor chip. The M1210 controller brings 12 Gbps Serial Attached SCSI (SAS) and 6 Gbps Serial ATA (SATA) performance to host controller, workstation, and server designs. The M1210 controller supports internal storage devices, which enables you to use a system that supports enterprise-class SAS drives, and desktop-class SATA drives. The M1210 controller can connect to drives directly. Simplified cabling between devices is an additional benefit. The M1210 controller supports four internal SAS/SATA ports through one internal x4 Mini-SAS HD connector (SFF-8643). The M1210 controller integrates four high-performance SAS/SATA physical layers (PHYs) and a PCI Express bus master direct memory access (DMA) core. Each of the four PHYs supports 12 Gbps SAS link rates and 6 Gbps SATA III link rates. The LSISAS3004 device increases system performance and provides fault-tolerant data storage. The LSISAS3004 input/output controller (IOC) device supports data striping across multiple disks, which reduces disk access time because multiple disks read or write data simultaneously. In addition, the device backs up data with either data mirroring or a parity block. Either backup method enables you to recover lost data in the event of a disk failure. You can select the data backup method that best suits your needs. The M1210 controller supports the SAS protocol as described in the Serial Attached SCSI Standard, version 3.0, and the SATA III protocol defined by the Serial ATA Revision 3.0 Specification. Note: You cannot mix SAS drives and SATA drives in the same virtual drive. Each port on the M1210 controller supports SAS devices, SATA devices, or both using the following: • SAS Serial SCSI Protocol (SSP), which enables communication with other SAS devices • SATA, which enables communication with other SATA devices • Serial Management Protocol (SMP), which communicates topology management information directly with an attached SAS expander device • Serial Tunneling Protocol (STP), which enables communication with a SATA device through an attached expander Controller guidelines Before you install the M1210 controller, read the following guidelines: © Copyright Lenovo 2016 1 • You can connect only one device per SAS PHY unless you use an expander. • Cables have to meet the SAS specification. • You cannot mix SAS drives and SATA drives in the same virtual drive. • You cannot mix SAS solid-state drives (SSDs) or SATA SSDs and existing mechanical SAS drives or SATA drives in the same virtual drive. See “Power supply requirements of the M1210 controller” on page 17 for information about the power requirements, and “Operating and non-operating conditions” on page 17 for information about the minimum and the maximum temperature ranges.