CONTAINS SULFURIC ACID. DO NOT BREATHE FUMES. DO NOT GET IN EYES, ON SKIN, OR ON CLOTHING. USE DANGER: Causes severe skin burns and eye damage. Causes serious eye damage. Fatal if inhaled. ONLY WITH COMPLETE EYE PROTECTION. In case of contact, immediately flush skin or eyes with cool water for at least May cause respiratory irritation. May cause cancer. Harmful to aquatic life. Harmful to aquatic life with fifteen minutes and get medical attention. USE ONLY WITH GOOD VENTILATION. United 77 long-lasting effects. BIATRON® quickly dissolves obstructions such as grease, hair, sanitary napkins, rags, sludge, soap, paper, coffee grounds Obtain special instructions before use. Do not handle until all safety precautions have been read in drains. Not recommended for use in sewer lines, catch basins, and large grease traps where fumes may accumulate. and understood. Do not breathe vapor. Use only outdoors or in a well-ventilated area. Avoid Removes lime scale and rust deposits from drains and traps. Will not harm septic tanks or pipes. Use weekly in all drains release to the environment. Wear protective gloves/protective clothing/eye protection/face as preventive maintenance measure. WILL ATTACK ANYTHING ORGANIC. Do not spill on floor, wood, painted surfaces. protection. Store in a well-ventilated place. If swallowed: Rinse mouth. Do not induce vomiting. If Do not use on copper or other soft metal piping. Do not use on aluminum. Do not place container on porcelain surfaces, on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. or permit product to come in contact with non-acid resistant surfaces. When using a measuring device, always rinse device ® If inhaled: Remove individual to fresh air and keep comfortable for breathing. If in eyes: Rinse thoroughly with cold water before and after use. cautiously with water for several minutes. Remove contact lenses, if present and able to do so. DIRECTIONS FOR USE: Remove all visible water from toilet, sinks and drains using a jackrabbit pump (United A130). Continue rinsing. Wash contaminated clothing before reuse. Keep container tightly closed. Store BIATRON according to local rules and regulations. Dispose of contents/container in accordance with local/ ALWAYS POUR AT ARM’S LENGTH, SO AS TO KEEP FACE AWAY FROM DRAIN WHILE USING. Flush with cold water for 5 minutes. NEVER pour BIATRON® Liquid Drain Cleaner into visible water. Before using BIATRON® on a completely Organic Digester and regional/national/international regulations. blocked drain, contact your United professional, or call 1-800-323-2594. FIRST AID MEASURES: Add BIATRON® according to table below. If drain has strainer, remove it if possible before applying this product. Always Liquid Drain Cleaner IF IN EYES: Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and add BIATRON® slowly to toilet bowls, as product generates heat which can cause cracking to porcelain as well as easy to do. Continuing rinsing. Call a physician or poison control immediately. overflowing & splattering of product. IF ON SKIN: Take off immediately all contaminated clothing. Rinse skin with water/shower. Call a physician or poison control immediately. Chemical burns must be treated by a physician. Wash contaminated clothing before reuse. DANGER POISON IF INHALED: Remove individual to fresh air and keep at rest in a position comfortable for breathing. Oxygen or CONTAINS SULFURIC ACID (CAS # 7664-93-9) artificial respiration if needed. Do not use mouth-to-mouth method if individual inhaled substance. Induce artificial DANGER—USE CAUTION DANGER–POISON respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. CAUSES SEVERE BURNS. Call a poison control or physician immediately. QUANTITY TIME FLUSH KEEP OUT OF REACH OF CHILDREN. IF SWALLOWED: Contact a physician or poison control immediately. Rinse mouth. Do not induce vomiting. If Sink 2 ounces (59.1mL) 15 min. Cold water 5 min. vomiting occurs, keep head low so that stomach content doesn’t get into the lungs. Toilet 12 ounces (354.9 mL) 15 min. Cold water 5 min. READ ALL CAUTION, ANTIDOTE, AND USE If exposed or concerned: Get medical advice/attention. Ensure that medical personnel are aware of the material(s) Small drain 16 ounces (473.2 mL) 15 min. Cold water 5 min. INSTRUCTIONS ON BACK PANEL BEFORE USING involved, and take precautions to protect themselves. ALWAYS PROTECT EYES WHEN USING THIS PRODUCT. ALWAYS POUR AT ARM’S LENGTH, SO AS TO KEEP FACE CONTAINS (CAS#): Sulfuric Acid (7664-93-9). AWAY FROM DRAIN WHILE USING. PRECAUCION AL USARIO: Si usted no puede leer Ingles, pregunte a NOT FOR HOUSEHOLD USE. FOR INDUSTRIAL USE. FOR USE ONLY BY EXPERIENCED MAINTENANCE REACTS VIOLENTLY WHEN COMBINED WITH ALKALINE DRAIN CLEANERS, HOT WATER OR ALKALINE CLEANERS. DO alguien que le traduzca esta etiqueta para usted antes de uso. PERSONNEL. NOT USE BEFORE, WITH, OR AFTER OTHER DRAIN CLEANERS OR CHEMICALS. DO NOT TRANSFER THIS PRODUCT An SDS for this product is available through United’s website, www.unitedlabsinc.com, providing 24 hour access. TO OTHER CONTAINERS. DO NOT ADD WATER TO CONTENTS WHILE IN A CONTAINER BECAUSE OF VIOLENT Please read the SDS carefully and follow all directions when using or handling this product. Never reuse empty REACTION. DO NOT BREATHE FUMES. ALWAYS USE WITH ADEQUATE VENTILATION. FUMES CAN BE FATAL IF Manufactured and Sold Exclusively By: containers. Incompatible materials may adversely react. CONCENTRATED AND INHALED. ONLY USE PRODUCT QUANTITIES OUTLINED IN APPLICATION TABLE AND ALWAYS UNITED LABORATORIES, INC. MAINTAIN GOOD VENTILATION. Fumes can cause headache, dizziness, or irritation. Never use a plunger while this Made in USA 1019 product is being used. Do not use hot water immediately before or after using this product. USE COLD WATER ONLY. When 320 37th Avenue • St. Charles, IL 60174 container is completely empty, rinse it out with cold water before disposal. 1-800-323-2594 • www.unitedlabsinc.com NET CONTENTS: 32 Fl. oz. (1 U.S. Qt.) 946 mL..
Recommended publications
  • How to Deal with a Sewer Back Up

    How to Deal with a Sewer Back Up

    INSTRUCTIONS ON HOW TO DEAL WITH A SEWER BACK UP CONTACT US FIRST Veolia Water NA LLC (by calling 508-823-3582): A CREW WILL RESPOND TO ADDRESS THE SITUATION. CHECK THE CITY LINE FOR PROPER FLOW AND IDENTIFY THE LOCATION OF PROBLEM. IN ACCORDANCE WITH THE CITY OF TAUNTON, SEWER USE ORDINANCE, SECTION 19.7- SEWER LATERALS “IN THE EVENT OF A PLUGGED-UP OR BACKED-UP SEWER LINE, ANY WORK REQUIRED BETWEEN THE PUBLIC SEWER LINE AND THE BUILDING SHALL BE THE RESPONSIBILITY OF THE OWNER OF THE BUILDING OR PROPERTY.” THE PUBLIC SEWER CONSISTS OF THE MAIN SEWER LINES LOCATED UNDER THE STREETS BETWEEN MANHOLES. THE LATERAL LINE WHICH CONNECTS THE BUILDING TO THE MAIN LINE IN THE STREET IS THE RESPONSIBILITY OF THE PROPERTY OWNER IF THE PROBLEM IS IN THE LATERAL: YOU SHOULD CONTACT A PROFESSIONAL PLUMBER TO HAVE YOUR HOME'S SERVICE LINE CLEARED. ON THE OTHER HAND, AN ALTERNATIVE THAT MAY SAVE MONEY IS TO CLEAR THE SYSTEM YOURSELF. SEWER CLEANING EQUIPMENT MAY BE OBTAINED FROM RENTAL SERVICE STORES. HOWEVER, IF YOU ARE NOT EXPERIENCED WITH THE USE OF THIS EQUIPMENT, IT MAY BE SAFER TO EMPLOY A PLUMBING CONTRACTOR OR DRAIN CLEANER. CLEAN-UP PROCEDURES : PROCEED WITH THE CLEAN UP PROMPTLY. USE CAUTION WHEN CONDUCTING THE CLEAN UP. USE RUBBER GLOVES AND RUBBER BOOTS. YOU ARE DEALING WITH SEWAGE, AND SERIOUS HEALTH COMPLICATIONS ARE POSSIBLE. BLEACH AND WATER WILL HELP DISINFECT THE AREA. USE CAUTION WHEN USING ANY ELECTRICAL APPLIANCE IN A WET ENVIRONMENT. IF THE BREAKER BOX IS WET OR NEAR ANY WATER DO NOT, ATTEMPT TO SHUT OFF.
  • ILLICIT DISCHARGE DETECTION and ELIMINATION PROGRAM MANUAL 2017 IDDE Table of Contents

    ILLICIT DISCHARGE DETECTION and ELIMINATION PROGRAM MANUAL 2017 IDDE Table of Contents

    ILLICIT DISCHARGE DETECTION AND ELIMINATION PROGRAM MANUAL 2017 IDDE table of contents Section 1 – introduction 1.1 What is IDDE Section 2- Storm sewer mapping 2.1 Overview Section 3 – IDDE Ordinance 3.1 What is an Illicit Discharge? 3.2 What is an Illicit Connection? 3.3 City IDDE Ordinance Section 4 – Illicit Discharge Detection Procedures 4.1 Purpose 4.2 Reporting 4.2.1 Contact Information 4.2.2 Incident Documented 4.3 Outfall Inspections 4.3.1 Responsibility 4.3.2 Timing 4.3.3 Equipment 4.3.4 Activities 4.3.5 Follow-up Action Section 5 – Investigation Procedures 5.1 Purpose 5.2 Priority levels 5.3 Tracing the source 5.3.1 Case log 5.4 Follow up Action Section 6 – Corrective Actions 6.1 Purpose 6.2 Voluntary Compliance 6.3 Operational Problems 6.4 Enforcement Actions 6.3.1 Enforcement Timeline 6.3.2 Fines 6.3.3 Record of Investigation Section 7 – Public Education Section 8 – Record Keeping Section 9 – Staff Training Section 10 - References Section 1- Introduction 1.1 What is IDDE Illicit Discharge Detection and Elimination (IDDE) program is managed by the public works department where we look for different kinds of pollutants from entering the storm water system. The storm water system impacts the Missouri river as well as the surrounding lakes like crystal cove and Gateway Lake. This is to assist anyone whom may be in in the stormwater program to assist in training or procedures on responding to an illicit discharge. Section 2 – Stormwater system map 2.1 Overview The main component to stormwater program is mapping.
  • Toxicological Profile for Hydrogen Sulfide and Carbonyl Sulfide

    Toxicological Profile for Hydrogen Sulfide and Carbonyl Sulfide

    HYDROGEN SULFIDE AND CARBONYL SULFIDE 149 6. POTENTIAL FOR HUMAN EXPOSURE 6.1 OVERVIEW Hydrogen sulfide has been found in at least 34 of the 1,832 waste sites that have been proposed for inclusion on the EPA National Priorities List (NPL) and carbonyl sulfide was detected in at least 4 of the 1,832 waste sites (ATSDR 2015). However, the number of sites evaluated for these substances is not known and hydrogen sulfide and carbonyl sulfide are ubiquitous in the atmosphere. The frequency of these sites can be seen in Figures 6-1 and 6-2. Carbonyl sulfide and hydrogen sulfide are principal components in the natural sulfur cycle. Bacteria, fungi, and actinomycetes (a fungus-like bacteria) release hydrogen sulfide during the decomposition of 2- sulfur containing proteins and by the direct reduction of sulfate (SO4 ). Hydrogen sulfide is also emitted from volcanoes, stagnant or polluted waters, and manure or coal pits with low oxygen content (Aneja 1990; Khalil and Ramussen 1984). The majority of carbonyl sulfide that enters the environment is released to air and it is very abundant in the troposphere (Conrad and Meuser 2000; EPA 1994c, 1994d; Meinrat et al. 1992; Simmons et al. 2012; Stimler et al. 2010). It enters the atmosphere from both natural and anthropogenic sources (EPA 1994c, 1994d; Meinrat et al. 1992; Stimler et al. 2010). Carbonyl sulfide is released from wetlands, salt marshes, soil, oceans, deciduous and coniferous trees, and volcanic gases (Blake et al. 2004; EPA 1994c, 1994d; Meinrat et al. 1992; Rasmussen et al. 1982a, 1982b; Stimler et al.
  • Illicit Discharge Detection and Elimination

    Illicit Discharge Detection and Elimination

    City of Salinas Illicit Discharge Detection And Elimination Response Plan and Guidance Manual 2010 City of Salinas Illicit Discharge Detection and Elimination Response Plan Table of Contents Section 1 – Introduction ..................................................................................................................................3 1.1 Background .............................................................................................................................................3 1.2 Summary of the IDDE Program .........................................................................................................4 Section 2 – Storm Sewer System Map ...........................................................................................................5 2.1 Overview .................................................................................................................................................5 2.2 Mapping Procedures..............................................................................................................................5 Section 3 – IDDE Ordinance .........................................................................................................................5 3.1 What is an Illicit Discharge? .................................................................................................................5 3.2 What is an Illicit Connection? ..............................................................................................................6 3.3 City of Salinas
  • PLUMBING DICTIONARY Sixth Edition

    PLUMBING DICTIONARY Sixth Edition

    as to produce smooth threads. 2. An oil or oily preparation used as a cutting fluid espe cially a water-soluble oil (such as a mineral oil containing- a fatty oil) Cut Grooving (cut groov-ing) the process of machining away material, providing a groove into a pipe to allow for a mechani cal coupling to be installed.This process was invented by Victau - lic Corp. in 1925. Cut Grooving is designed for stanard weight- ceives or heavier wall thickness pipe. tetrafluoroethylene (tet-ra-- theseveral lower variouslyterminal, whichshaped re or decalescensecryolite (de-ca-les-cen- ming and flood consisting(cry-o-lite) of sodium-alumi earthfluo-ro-eth-yl-ene) by alternately dam a colorless, thegrooved vapors tools. from 4. anonpressure tool used by se) a decrease in temperaturea mineral nonflammable gas used in mak- metalworkers to shape material thatnum occurs fluoride. while Usedheating for soldermet- ing a stream. See STANK. or the pressure sterilizers, and - spannering heat resistantwrench and(span-ner acid re - conductsto a desired the form vapors. 5. a tooldirectly used al ingthrough copper a rangeand inalloys which when a mixed with phosphoric acid.- wrench)sistant plastics 1. one ofsuch various as teflon. tools to setthe theouter teeth air. of Sometimesaatmosphere circular or exhaust vent. See change in a structure occurs. Also used for soldering alumi forAbbr. tightening, T.F.E. or loosening,chiefly Brit.: orcalled band vapor, saw. steam,6. a tool used to degree of hazard (de-gree stench trap (stench trap) num bronze when mixed with nutsthermal and bolts.expansion 2. (water) straightenLOCAL VENT.
  • Jurisdictional Runoff Management Program January 2017

    Jurisdictional Runoff Management Program January 2017

    CITY OF ENCINITAS Jurisdictional Runoff Management Program January 2017 Technical support provided by Intentionally Left Blank 1 I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. r:+ 3 ~f ~~ ~' S ~'' ~ <: Signature ~ Date j r'Y~ ~ l G Name Title Intentionally Left Blank Acknowledgements The City of Encinitas 2015 Jurisdictional Runoff Management Program (JRMP) document has been prepared by the Department of Engineering Services, Clean Water Division, with the assistance of the following departments: Public Works, Planning & Building, Fire, Parks and Recreation, and IT/GIS. Staff from these departments are integral to the implementation of the City’s Clean Water Program and to ensuring compliance with San Diego Regional Water Quality Control Board Order No. R9-2013-0001, the Municipal Stormwater Permit. Recognition and acknowledgement are given to the following individuals for their contributions to the development of this program: Glenn Pruim, Public Works
  • Breakthrough Plus

    Breakthrough Plus

    breakthrough plus Product Properties CITRUS SOLVENT / COLOR: Clear Orange ODOR: Orange DEGREASER VISCOSITY: 20 cps FLASH POINT: 110°F DRAIN CLEANER SPECIFIC GRAVITY: 0.81 FOAMING: None CONCENTRATE DETERGENCY: Excellent SOLUBILITY IN WATER: Emulsifies Description This natural, powerful citrus solvent concentrate is the safe answer to the toughest degreasing, cleaning, drain/grease trap maintenance & odor control problems in your facility. FOR USE BY: Schools, Restaurants, Hotels, Office Buildings, Nursing Homes and Hospitals, Sanitation Depart- ments, Sewage Plants, Restrooms, Locker Rooms, Theaters, Apartments, Factories and Garages. CLEANS, DEGREASES AND REMOVES: Drain Clogs, Grease Trap Build-Up, Ink, Adhesive, Engine Grease, Road Tar, Chewing Gum, Soap Scum, Fuel Oil Deposits, Rubber Burn Marks, Sewage Grease, All Organic Odors and Pet Odors. Features...Benefits Concentrated . Economical Non-Caustic . .Improved User Safety Versatile . Ease of Use Fresh Scent . .Pleasant to Use Directions APPLICATION (AMOUNT): HOW TO USE: Drain opener Pour 16 oz. in drain. Let stand 1 hour, then flush (16 oz.) with hot water. Use as needed. Drain and grease trap Dilute in 1 gal. of hot water. Pour in drain/trap (4-8 oz.) and let stand 30 minutes. Flush with hot water. Use two times weekly or as needed. Garbage disposals & Pour directly into drain. Let stand 10-20 minutes. vegetable sinks Flush with hot water. Use as needed. (2-6 ounces) General surfaces Dilute in 1 gal. warm water. Apply to surface. Let cleaning / degreasing stand 5 minutes if desired, then rinse (3-8 oz.) thoroughly. Use as needed. Use straight or dilute 1100 Central Industrial Dr. up to 6 oz.
  • 10 Things You Don't Know About Home Sewer Explosions

    10 Things You Don't Know About Home Sewer Explosions

    10 Things You Don’t Know about Home Sewer Explosions and Home Contamination Reduce the likelihood of sewer backup in your home More than 500,000 sewer backups occur each year in the United States. Sewers normally back up through the lowest plumbing fixture in your home. According to the Insurance Institute for Business & Home Safety (IBHS), 68% of all drain system sewer backup claims started in the basement and claims occurring in finished basements are 65% more severe than in unfinished basements. Even if you are adeQuately protected financially through your insurance coverage, it’s worth the time and investment to prevent the inconvenience and health hazard from a major sewer backup. Depending on the severity of the loss, your family may need to live elsewhere while your home is restored to a habitable condition. Nationwide Private Client Risk Solutions recommends the following steps to help prevent sewer or drain backups: • Have your home’s sewer lateral line periodically inspected for buildup, cracks, and invading tree roots. If you have a cast-iron or clay lateral pipe, you may want to have a PVC pipe installed to reduce the risk of tree root problems. Homeowners, not your local municipality, are responsible for maintaining the sewer lateral lines. • Don’t pour grease down your kitchen sink. It can congeal, cling to your pipes and cause serious damage and blockage. • Compost or throw away larger food items rather than grinding them in the food waste disposer. • Don’t flush anything other than toilet paper down the toilet, even if the product packaging suggests that it is flushable.
  • 2018 Wssc Plumbing & Fuel Gas Code

    2018 Wssc Plumbing & Fuel Gas Code

    WASHINGTON SUBURBAN SANITARY COMMISSION 2018 WSSC PLUMBING & FUEL GAS CODE Effective Date: July 1, 2018 CERTIFICATION OF AUTHORITY The General Counsel certifies that the statutory authority for the adoption of this Code is: Annotated Code of Maryland: Maryland Public Utilities Article: §§ 17-403, 17-404, 17-406, 23-101, 24-101, 24-102, 24-103, 24-104, 24-105, 24- 106, 24-201, 24-801, 25-101, 25-105, 29-101, 29-102, 29-103, 29-105, 29-107 Business Occupations and Professions Article: §§ 12-305, 12-307 Environment Article: §9-332 Explanation of Formatting: Additions and revisions between this version of the Code and the previous Code are indicated with a thick vertical line in the right margin (as shown to the right). Deletions are indicated with a horizontal arrow (as shown to the right). In addition to the margin indicators, additional or revised language features blue colored text to detail the referenced changes. 2018 WSSC PLUMBING & FUEL GAS CODE 1 TABLE OF CONTENTS TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION ..................................................................................... 15 SECTION 101 GENERAL .................................................................................................... 15 101.1 Title ....................................................................................................................... 15 101.2 Purpose .................................................................................................................. 15 101.3 Adoption of Model Codes ....................................................................................
  • ILLICIT DISCHARGE DETECTION and ELIMINATION PROGRAM Policies and Procedures

    ILLICIT DISCHARGE DETECTION and ELIMINATION PROGRAM Policies and Procedures

    ILLICIT DISCHARGE DETECTION AND ELIMINATION PROGRAM Policies and Procedures May 2020 Acknowledgments The cities of Redmond, Kirkland, Woodinville and Bothell would like to thank the City of Bainbridge Island for generously sharing their Illicit Discharge Detection and Elimination Program Manual, April 2010, which became the base template from which this document was created. The City of Bothell would like to extend additional gratitude to Snohomish County, King County, and the City of Kirkland for their extensive information-sharing regarding bacteria source tracing approaches and experiences. Table of Contents Section 1 – Introduction .................................................................................................................... 5 1.1 Background .................................................................................................................................... 5 1.2 Summary of the IDDE Program ....................................................................................................... 6 Section 2 – Storm System Map ......................................................................................................... 7 2.1 Overview ....................................................................................................................................... 7 2.2 Mapping Procedures ...................................................................................................................... 8 Section 3 – IDDE Ordinance ..............................................................................................................
  • Evaluation of Trench and Slotted Drain Maintenance and Cleaning – Phase 1

    Evaluation of Trench and Slotted Drain Maintenance and Cleaning – Phase 1

    EVALUATION OF TRENCH AND SLOTTED DRAIN MAINTENANCE AND CLEANING – PHASE 1 Prepared by: Hazem Elzarka Ce Gao Prepared for: The Ohio Department of Transportation, Office of Statewide Planning & Research State Job Number 135319 March, 2017 Final Report Technical Report Documentation Page 1. Report No. 2. Government Accession No. 3. Recipient's Catalog No. FHWA/OH-2017-11 4. Title and Subtitle 5. Report Date March, 2017 Evaluation of Trench and Slotted Drain Maintenance and 6. Performing Organization Code Cleaning – Phase 1 7. Author(s) (include 16 digit ORCID ID) 8. Performing Organization Report No. Hazem Elzarka (0000-0003-2845-4568) Ce Gao 9. Performing Organization Name and Address 10. Work Unit No. (TRAIS) University of Cincinnati 765 Baldwin Hall 11. Contract or Grant No. 2850 Campus Ways Cincinnati, OH 45221-0071 SJN 135319 12. Sponsoring Agency Name and Address 13. Type of Report and Period Covered Ohio Department of Transportation 1980 West Broad Street 14. Sponsoring Agency Code Columbus, Ohio 43223 15. Supplementary Notes 16. Abstract Trench and slotted drains are increasingly being used by ODOT to remove storm water from the roadways. These drains have to be properly cleaned and maintained to prevent vehicles from hydroplaning, eliminate flooding and avoid premature roadway failure. ODOT’s current methods for cleaning/maintaining trench and slotted drains take a lot of time and are expensive. This research report documents the current methods that ODOT utilizes for cleaning trench and slotted drains and recommends alternative cleaning methods that can improve safety, production rate and cost effectiveness. Currently, ODOT cleans trench drains manually or using a Sewer Cleaner.
  • How to Use THRIFT Drain Cleaner HOME > Non-Acid Cleaner > How to Use Thrift

    How to Use THRIFT Drain Cleaner HOME > Non-Acid Cleaner > How to Use Thrift

    3/23/2018 How to Use | Thrift Marketing, LLC. How to Use THRIFT Drain Cleaner HOME > Non-Acid Cleaner > How to use Thrift THRIFT HOME NON-ACID CLEANER You must use HOT WATER to activate SUPER PRO ACID Thrift's dry, odorless crystals CALCI-BUSTER Thrift Instructional Video How to Use Thrift Wholesalers, Distributors where to buy CONTACT Thrift Marketing Sales Reps SMALL DRAINS: When fixtures begin to drain slowly, it is usually due to the build up of grease, hair, soap scum or bath oils. To prevent complete stoppage, let HOT water run to warm lines. Add one cup of Thrift directly into drain opening. Let hot water run until all chemical is dissolved (use approximately 2 cups of hot water to a cup of Thrift). Let stand one minute then flush with HOT water. To keep drains working properly, add 1/2 to 1 cup of Thrift once a month. If drain is completely stopped up, use a cable to open drain to allow water to flow then add Thrift as directed above, to ensure a proper working drain. GREASE TRAPS: A regular treatment of 2 lbs. of Thrift for each 100 gallons of capacity will greatly reduce the costly pumping and cleaning of your grease trap by keeping the grease and suspended solids in a liquid form, allowing your grease trap to function properly. Thrift may be applied at any drain leading to grease trap. Pour in dry and follow with enough HOT water to dissolve all chemical. Allow Thrift to stand in grease traps as long as possible, overnight for maximum results.