C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20180112-E494674 Report Reference E494674-20180113 Issue Date 2018-JANUARY-12

Issued to: Henglan Boyi Electrical Appliance Factory 2/F Bldg 3 No 2 Yihui 3rd Rd Block B Maohui Industial Park Henglan Town, Zhongshan 528400

This is to certify that FLEXIBLE CORD representative samples of PVC Insulated Parallel Cords, Types SPT 1, SPT-2 and SPT 3

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 62 Flexible Cords and Cables CSA C22.2 NO. 49 Flexible Cords and Cables Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information

---

Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 1 File E494674 Project 4788083043

January 13, 2018

REPORT

On

FLEXIBLE CORD

ZHONGSHAN HENGLAN BOYI ELECTRICAL APPLIANCE FACTORY GUANGDONG 528400, CHINA

Copyright  2018 UL LLC

UL LLC authorizes the above named company to reproduce this Report only for purposes as described in the Conclusion, provided it is reproduced in its entirety. File E494674 Vol. 1 Sec. 2 Page 1 Issued: 2018-01-13 and Report

DESCRIPTION

PRODUCT COVERED:

USL, CNL: PVC Insulated Parallel Cords, Types SPT-1, SPT-2 and SPT-3

TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE’S USE):

USL indicates investigations to Underwriters Laboratories Inc. Standard UL 62, for Flexible Cords and Cables.

CNL indicates investigations to Canadian Standard C22.2 No. 49 for Flexible Cords and Cables.

CONSTRUCTION DETAILS:

These cords are constructed in accordance with the latest Edition of Underwriters Laboratories Inc. Standard for Flexible Cords and Cables, UL 62 and CSA C22.2 No. 49.

INTEGRAL/NON-INTEGRAL INSULATION:

PVC Class 4 (60C), Class 5 (75C), Class 6 (90C) or Class 7 (105C).

NON-INTEGRAL GROUNDING CONDUCTOR:

Cords may include non-integral grounding conductor in addition to two circuit conductors but not in addition to three circuit conductors.

PVC Class 4 (60C), Class 5 (75C), Class 6 (90C) or Class 7 (105C).

MARKING:

These cords are marked in accordance with the Standard, FUII, and Section General.

Flame test marking “VW-1”, “FT1”, and “FT2” authorized. C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20180112-E494674 Report Reference E494674-20180112 Issue Date 2018-JANUARY-12

Issued to: Zhongshan Henglan Boyi Electrical Appliance Factory 2/F Bldg 3 No 2 Yihui 3rd Rd Block B Maohui Industial Park Henglan Town, Zhongshan Guangdong 528400 CHINA

This is to certify that FLEXIBLE CORD representative samples of Decorative Cords, Types SPT-1W and SPT-2W.

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 62 Flexible Cords and Cables CSA C22.2 NO. 49 Flexible Cords and Cables Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information

---

Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 1 File E494674 Project 4788083043

January 12, 2018

REPORT

On

FLEXIBLE CORD

ZHONGSHAN HENGLAN BOYI ELECTRICAL APPLIANCE FACTORY GUANGDONG 528400, CHINA

Copyright  2018 UL LLC

UL LLC authorizes the above named company to reproduce this Report only for purposes as described in the Conclusion, provided it is reproduced in its entirety. File E494674 Vol. 1 Sec. 1 Page 1 Issued: 2018-01-12 and Report

DESCRIPTION

PRODUCT COVERED:

USL/CNL: Decorative Cords, Types SPT-1W and SPT-2W.

TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE’S USE)

USL indicates investigations to Underwriters Laboratories Inc. Standard UL 62, for Flexible Cords and Cables.

CNL indicates investigations to Canadian Standard C22.2 No. 49 for Flexible Cords and Cables.

CONSTRUCTION DETAILS:

These cords are constructed in accordance with the latest Edition of Underwriters Laboratories Inc. Standard for Flexible Cords and Cables, UL 62 and CSA C22.2 No. 49.

INSULATION:

PVC Class 7 (105C).

These cords must use a Recognized Component - Polymeric Materials for Use in Wire, Cable and Flexible Lighting Products (QMTT2), PVC Decorative Cord Insulation Compounds, suitable for use in these cords.

MARKING:

These cords are marked in accordance with the Standard, FUII, and Section General.

“FT2”, “FT1” or “VW-1” shall be marked on cords. C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20180425-E494674 Report Reference E494674-20180114 Issue Date 2018-APRIL-25

Issued to: Zhongshan Henglan Boyi Electrical Appliance Factory 2/F Bldg 3 No 2 Yihui 3rd Rd Block B Maohui Industial Park Henglan Town, Zhongshan Guangdong 528400 CHINA

This is to certify that FLEXIBLE CORD representative samples of PVC Jacketed Cords, Types: SVT, SJT, ST, SJTW

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 62, Flexible Cords and Cables CSA C22.2 NO. 49, Flexible Cords and Cables

Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 1 File E494674 Project 4788083043

January 14, 2018

REPORT

On

FLEXIBLE CORD

ZHONGSHAN HENGLAN BOYI ELECTRICAL APPLIANCE FACTORY GUANGDONG 528400, CHINA

Copyright  2018 UL LLC

UL LLC authorizes the above named company to reproduce this Report only for purposes as described in the Conclusion, provided it is reproduced in its entirety. File E494674 Vol. 1 Sec. 3 Page 1 Issued: 2018-01-14 and Report Revised: 2018-04-25

DESCRIPTION

PRODUCT COVERED:

USL, CNL: PVC Jacketed Cords, Types SVT, SJT, ST, SJTW.

TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE):

USL indicates investigations to Underwriters Laboratories Inc. Standard UL 62, for Flexible Cords and Cables.

CNL indicates investigations to Canadian Standard C22.2 No. 49 for Flexible Cords and Cables.

CONSTRUCTION DETAILS:

These cords are constructed in accordance with the latest Edition of Underwriters Laboratories Inc. Standard for Flexible Cords and Cables, UL 62 and Canadian Standard CSA C22.2 No. 49. File E494674 Vol. 1 Sec. 3 Page 2 Issued: 2018-01-14 and Report Revised: 2018-04-25

INSULATION:

PVC Class 4 (60C), Class 5 (75C), Class 6 (90C) or Class 7 (105C).

FILLER:

Optional, constructed in accordance with the Standard.

SHIELD:

Optional, constructed in accordance with the Standard.

JACKET:

PVC Class 1.5 (60C), Class 1.6 (75C), Class 1.7 (90C) or Class 1.8 (105C).

Outdoor use cords, “W” Types, must use Recognized Component – Polymeric Materials for Use in Wire, Cable and Flexible Lighting Products (QMTT2), PVC 720 Hour Sunlight Resistant Jacket Compounds with the same or higher temperature rating as the cord.

MARKING:

These cords are marked in accordance with the Standard, FUII, and Section General.

Flame test marking “VW-1”, “FT1”, and “FT2” authorized. File E494675 Project 4788083045

January 5, 2018

REPORT

On

COMPONENT - APPLIANCE WIRING MATERIAL

ZHONGSHAN HENGLAN BOYI ELECTRICAL APPLIANCE FACTORY GUANGDONG, 528400, CHINA

Copyright  2018 UL LLC

UL LLC authorizes the above named company to reproduce this Report only for purposes as described in the Conclusion. The Report should be reproduced in its entirety; however to protect confidential product information, the Construction Details Descriptive pages may be excluded. File E494675 Page 1 Issued: 2018-01-05

DESCRIPTION

PRODUCT COVERED:

Appliance Wiring Material, Styles 1007, 1015, 2468 and 20288 in accordance with UL 758, Third edition, Revised date 2017-06-02. File E494675 Project 4788083045

January 6, 2018

REPORT

on

COMPONENT - Appliance Wiring Material

ZHONGSHAN HENGLAN BOYI ELECTRICAL APPLIANCE FACTORY GUANGDONG, 528400, CHINA

Copyright © 2018 UL LLC

UL LLC authorizes the above named company to reproduce this Report only for purposes as described in the Conclusion. The Report should be reproduced in its entirety; however to protect confidential product information, the Construction Details Descriptive pages may be excluded. File E494675 Vol. 1 Sec. 6 Page 1 Issued: 2018-01-06 and Report Revised: 2018-03-02

TABLE OF CONTENTS

Material Construction Description No. Test Records

PVC Insulated Single 1 1

PVC Multiconductor Flat 2 1 Ribbon Cable

FEP Insulated Single 3 2 File E494675 Vol. 1 Sec. 6 Page 2 Issued: 2018-01-06 and Report

DESCRIPTION NO. 1

PRODUCT COVERED:

CNR: Appliance Wire, Extruded PVC Insulated Singles, Class I, Group A, B, or A/B.

TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE):

CNR indicates investigation to Canadian Standard C22.2 No. 210. This product shall be constructed in accordance with the Canadian Standard for Appliance Wiring Material Products, C22.2 No. 210, and as described below:

CONSTRUCTION DETAILS:

Marking - In accordance with the Section General.

Construction - This is an insulated single with extruded PVC insulation.

Conductor – Solid or stranded, size in accordance with the Table below.

Insulation – In accordance with the Table below.

Table 1

Material: Class No. 21, PVC Temperature Rating: 60, 75, 80, 90 or 105C Use Class: I (Internal) Group: A (Not subject to mechanical abuse), B (Potentially subject to mechanical abuse), or A/B Flame Rating: FT1 and/or FT2

Minimum Average Minimum Thickness Thickness, mils At Any Point, mils Conductor Size 30 V 150 V 300 V 600 V 1000 V 30 V 150 V 300 V 600 V 1000 V 44 – 10 AWG 14 14 14 14 - 12 12 12 12 - 9 – 2 AWG 14 14 14 - - 12 12 12 - - 1 – 4/0 AWG 14 14 - - - 12 12 - - - 250 - 500 kcmil 14 14 - - - 12 12 - - - 501 - 1000 14 - - - - 12 - - - - kcmil 1001 - 2000 ------kcmil File E494675 Vol. 1 Sec. 6 Page 3 Issued: 2018-01-06 and Report

DESCRIPTION NO. 2

PRODUCT COVERED:

CNR: Appliance Wire, Extruded PVC, Multiconductor Flat Ribbon Cable, Class I, Group A, B, or A/B.

TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE’S USE):

CNR indicates investigation to Canadian Standard C22.2 No. 210. This product shall be constructed in accordance with the Canadian Standard for Appliance Wiring Material Products, C22.2 No. 210, and as described below.

CONSTRUCTION DETAILS:

Marking - In accordance with the Section General.

Construction - This is a multiconductor flat ribbon cable with PVC insulation.

Conductor - Solid or stranded, in accordance with the Table below.

Insulation – In accordance with the Table below.

Table 1

Material: Class No. 21, PVC Temperature Rating: 60, 75, 80, 90 or 105C Use Class: I (Internal) Group: A (Not subject to mechanical abuse), B (Potentially subject to mechanical abuse), or A/B Flame Rating: FT1 and/or FT2

Minimum Average Minimum Thickness Thickness, mils At Any Point, mils Conductor Size 30 V 150 V 300 V 600 V 1000 V 30 V 150 V 300 V 600 V 1000 V 44 – 10 AWG 12 12 12 - - 10 10 10 - - 9 – 2 AWG 12 12 - - - 10 10 - - - 1 – 4/0 AWG 12 - - - - 10 - - - - 250 - 500 kcmil 12 - - - - 10 - - - - 501 - 1000 ------kcmil 1001 - 2000 ------kcmil File E494675 Vol. 1 Sec. 6 Page 4 Issued: 2018-01-06 and Report New: 2018-03-02

DESCRIPTION NO. 3

PRODUCT COVERED:

Appliance Wire, Extruded FEP Insulated Singles, Class I, Group A, B, or A/B.

TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE’S USE):

CNR indicates investigation to Canadian Standard C22.2 No. 210. This product shall be constructed in accordance with the Canadian Standard for Appliance Wiring Material Products, C22.2 No. 210, and as described below. File E494675 Vol. 1 Sec. 6 Page 5 Issued: 2018-01-06 and Report New: 2018-03-02

CONSTRUCTION DETAILS:

Marking - In accordance with the Section General.

Construction - This is an insulated single with extruded FEP insulation. See below for details.

Conductor - Solid or stranded, size in accordance with the tables below.

Insulation - In accordance with the tables below.

TABLE 1

Insulation Material: FEP Class 25 Use Class: I (Internal) Group: A (Not subject to mechanical abuse) B (Potentially subject to mechanical abuse), or A/B Voltage Rating: 30, 150 or 300 V Temperature Rating: 60, 75, 80, 90, 105, 125, 150, 180 or 200C Flame Rating: FT1 and/or FT2 Minimum Average Thickness, Minimum Thickness at any Conductor Size mils point, mils 30V 150V 300V 600V 1000V 30V 150V 300V 600V 1000V 44-10 AWG 13 13 13 - - 11 11 11 - - 9-2 AWG 13 13 - - - 11 11 - - - 1-4/0 AWG 13 - - - - 11 - - - - 250-500 kcmil 13 - - - - 11 - - - - 501-1000 kcmil ------1001-2000 kcmil ------C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20180306-E494675 Report Reference E494675-20180105 Issue Date 2018-MARCH-06

Issued to: Zhongshan Henglan Boyi Electrical Appliance Factory 2/F Bldg 3 No 2 Yihui 3rd Rd Block B Maohui Industial Park Henglan Town Zhongshan Guangdong 528400 CHINA

This is to certify that COMPONENT - APPLIANCE WIRING MATERIAL representative samples of “See Addendum Page”

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 758 - Appliance Wiring Material Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information

---

Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service.

The UL Recognized Component Mark generally consists of the manufacturer’s identification and catalog number, model number or other product designation as specified under “Marking” for the particular Recognition as published in the appropriate UL Directory. As a supplementary means of identifying products that have been produced under UL’s Component Recognition Program, UL’s Recognized Component Mark: , may be used in conjunction with the required Recognized Marks. The Recognized Component Mark is required when specified in the UL Directory preceding the recognitions or under “Markings” for the individual recognitions.

Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 2 C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20180306-E494675 Report Reference E494675-20180105 Issue Date 2018-MARCH-06

This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements.

SINGLE-CONDUCTOR THERMOPLASTIC-INSULATED WIRE:

STYLES 1007, 1015, 1332

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 2 of 2 C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20180108-E494675 Report Reference E494675-20180105 Issue Date 2018-JANUARY-08

Issued to: Zhongshan Henglan Boyi Electrical Appliance Factory 2/F Bldg 3 No 2 Yihui 3rd Rd Block B Maohui Industial Park Henglan Town Zhongshan Guangdong 528400 CHINA

This is to certify that COMPONENT - APPLIANCE WIRING MATERIAL representative samples of See Addendum Page

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: Standard UL 758,Appliance Wiring Material Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information

---

Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service.

The UL Recognized Component Mark generally consists of the manufacturer’s identification and catalog number, model number or other product designation as specified under “Marking” for the particular Recognition as published in the appropriate UL Directory. As a supplementary means of identifying products that have been produced under UL’s Component Recognition Program, UL’s Recognized Component Mark: , may be used in conjunction with the required Recognized Marks. The Recognized Component Mark is required when specified in the UL Directory preceding the recognitions or under “Markings” for the individual recognitions.

Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 2 C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20180108-E494675 Report Reference E494675-20180105 Issue Date 2018-JANUARY-08

This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements.

Models/Product TABLE OF AUTHORIZED STYLES MULTI-CONDUCTOR THERMOPLASTIC-INSULATED WIRE 2468, 20288

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 2 of 2 C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20180306-E494675 Report Reference E494675-20180106 Issue Date 2018-MARCH-06

Issued to: Zhongshan Henglan Boyi Electrical Appliance Factory 2/F Bldg 3 No 2 Yihui 3rd Rd Block B Maohui Industial Park Henglan Town Zhongshan Guangdong 528400 CHINA

This is to certify that COMPONENT - APPLIANCE WIRING MATERIAL representative samples of “See Addendum Page”

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 758 - Appliance Wiring Material CSA C22.2 No. 210 - Appliance Wiring Material Products Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information

---

Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service.

The UL Recognized Component Mark generally consists of the manufacturer’s identification and catalog number, model number or other product designation as specified under “Marking” for the particular Recognition as published in the appropriate UL Directory. As a supplementary means of identifying products that have been produced under UL’s Component Recognition Program, UL’s Recognized Component Mark: , may be used in conjunction with the required Recognized Marks. The Recognized Component Mark is required when specified in the UL Directory preceding the recognitions or under “Markings” for the individual recognitions.

Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 2 C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20180306-E494675 Report Reference E494675-20180106 Issue Date 2018-MARCH-06

This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements.

CNR: Appliance Wire, Extruded PVC Insulated Singles, Class I, Group A, B, or A/B. CNR: Appliance Wire, Extruded PVC, Multiconductor Flat Ribbon Cable, Class I, Group A, B, or A/B. Appliance Wire, Extruded FEP Insulated Singles, Class I, Group A, B, or A/B.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 2 of 2 File E494675 Project 4788171257

March 02, 2018

REPORT

On

COMPONENT - APPLIANCE WIRING MATERIAL

ZHONGSHAN HENGLAN BOYI ELECTRICAL APPLIANCE FACTORY GUANGDONG 528400 CHINA

Copyright  2018 UL LLC

UL LLC authorizes the above named company to reproduce this Report only for purposes as described in the Conclusion. The Report should be reproduced in its entirety; however to protect confidential product information, the Construction Details Descriptive pages may be excluded. File E494675 Page 1 Issued: 2018-03-02

DESCRIPTION

PRODUCT COVERED:

Appliance Wiring Material, Styles 1332 in accordance with UL 758, 3rd edition, Revised date 2017-06-02. C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20180131-E494673 Report Reference E494673-20180127 Issue Date 2018-JANUARY-31

Issued to: Zhongshan Henglan Boyi Electrical Appliance Factory 2/F Bldg 3 No 2 Yihui 3rd Rd Block B Maohui Industial Park Henglan Town Zhongshan Guangdong 528400 CHINA

This is to certify that CORD SETS AND POWER-SUPPLY CORDS representative samples of General Use Power Supply Cords

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 817, cords Sets and Power-Supply Cords CSA C22.2 No. 21-14, Cords Sets and Power Supply Cords

Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 1 File E494673 Project 4788083042

January 28, 2018

REPORT

on

UNLISTED COMPONENT - ATTACHMENT PLUGS, FUSELESS

For Use Only In

APPLICANT’S CORD SETS AND POWER-SUPPLY CORDS

Zhongshan Henglan Boyi Electrical Appliance Factory Zhongshan, Guangdong, 528400 China

Copyright  2018 UL LLC

UL LLC authorizes the above named company to reproduce this Report only for purposes as described in the Conclusion. The report should be reproduced in its entirety; however if necessary to protect confidential product information, the Construction Details Descriptive pages may be excluded. File E494673 Vol. 2 Sec. 1 Page 1 Issued: 2018-01-28 and Report Revised: 2018-05-08

DESCRIPTION

PRODUCT COVERED:

USU, CNU - Unlisted Component – Attachment Plugs, Cat. Nos. BY-22 and BY-33.

ELECTRICAL RATING:

Cat. No. Config. Cord, AWG Current, A Volts, V BY-22 1-15P 18/2 10 125 16/2 13 125 BY-33 5-15P 18/3 10 125 16/3 13 125

TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE’S USE):

For use only in (or with) Applicant's cord sets and power supply cords where the acceptability is determined by UL LLC.

USU - Indicates investigation to United States Standard UL 817, Twelfth Edition.

CNU - Indicates investigation to Canadian Standard, CSA C22.2 No. 21-14, Ninth Edition.

Conditions of Acceptability:

1. The devices have been evaluated when molded on the specific conductor size specified in this Procedure.

2. Use with any other type or size cord may require additional evaluation.

3. These fittings shall be used only within their electrical rating. File E494673 Vol. 2 Sec. 1 Page 2 Issued: 2018-01-28 and Report

CAT. NO. BY-22 - FIG. 1

General - The general design, shape and arrangement shall be as illustrated except where variations are specifically described. The Configuration is identical to NEMA 1-15P. See ILL. 1 to exposed blades dimensions.

Body – Molded PVC, R/C (QMFZ2/8), Cat. No. 730, manufactured by SILVER AGE ENGINEERING PLASTICS () CO LTD (E225348), rated V-0, minimum thickness of 1.5 mm. See ILL. 2 for demensions details.

Inner Body – Molded PBT, R/C (QMFZ2/8), Cat. No. 4120, manufactured by CHANG CHUN CHEMICAL (ZHANGZHOU) CO LTD (E304813), rated V-0, minimum thickness of 0.82 mm. See ILL. 3 for demensions details.

Line/Neutral Blade - R/C (AXNU2), Cat. No. SH995, manufactured by SHIAN HWI ENTERPRISE CO LTD (E168608), suitable for use with the conductor types and sizes, insulation class and curing method as specified in the installation instructions provided with the blade. Blades is secured to conductor using the tools, method and recommended crimped height as specified in the blade instruction sheet for the blade employed.

Cord – Flexible cord, Listed (ZJCZ/7). See the following table for application details.

Cord Size (AWG) Cord Type USL CNL 18/2 SPT-1, SPT-2, SVT YES YES 16/2 SPT-2, SVT YES YES

Marking - See Sec. Gen. File E494673 Vol. 2 Sec. 1 Page 3 Issued: 2018-01-28 and Report New: 2018-05-08

CAT. NO. BY-33 - FIG. 2

General - The general design, shape and arrangement shall be as illustrated except where variations are specifically described. See ILL. 4 to exposed blades dimensions.

1. Body - R/C (QMFZ2/QMFZ8), PVC molded, Type 730, SILVER AGE ENGINEERING PLASTICS (DONGGUAN) CO LTD, (E225348), rated V-0, minimum thickness of 1.5 mm. See ILL. 5 for dimensional details.

2. Inner Body – R/C (QMFZ2/QMFZ8), PBT molded, Type 4130, CHANG CHUN CHEMICAL (ZHANGZHOU) CO LTD, (E304813), rated V-0, minimum thickness of 0.38 mm. See ILL. 6 for dimensional details.

3. Blade – R/C (AXNU2), Cat. No. SH996, SHIAN HWI ENTERPRISE CO LTD, (E168608), suitable for use with the conductor types and sizes, insulation class and curing method as specified in the installation instructions provided with the blade. Blade is secured to conductors using the tools, method and recommended crimp height as specified in the blade installation instruction sheet for the blade employed.

4. Grounding Pin - Copper alloy, one provided, crimp to conductor, measured crimp length of 3.7 mm. See ILL. 7 for dimensional details.

5. Flexible Cord – Listed (ZJCZ/ZJCZ7), crimp to contact. See the following table for application details.

Cord Size (AWG) / No. of Conductors Cord Type USL CNL 18/3 SVT, SJT YES YES 16/3 SVT, SJT YES YES

6. Marking - See Sec. Gen.