How to Remove Contamination in a Cell Culture Lab
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
A Statutory Authority Established Under the Food Safety
File No. 12015/03/2017-QA Food Safety and Standards Authority of India (A statutory Authority established under the Food Safety and Standards Act, 2006) (Quality Assurance Division) FDA Bhawan, Kotla Road, New Delhi – 110002 Dated, the 28th June, 2018 RFP No. 01/2018-19 FOR SETTING UP MICROBIOLOGY SECTION AND INSTALLATION OF EQUIPMENTS: CORRIGENDUM Further to this office Tender Enquiry No. 01/2018-19 dated 15th June 2018 and Pre-Bid conference held on 25th June 2018. 2. The following amendment are made in the ibid tender: PART II – ESSENTIAL DETAILS OF ITEMS/SERVICES REQUIRED 2. Technical Details: Technical specifications for CLEAN ROOM laboratory set up & FURNITURE at CFL, Kolkata, on turnkey basis - Sl. No Specifications 1. GENERAL: The microbiology laboratory shall be modular with unidirectional flow with different zones. The area purposed for the Microbiology Lab is mentioned in Annexure A to accommodate the area/activities mentioned below. A representative zoning floor plan is shown as Annexure B which can be suitably modified by the bidder keeping the flow (personnel and sample) unidirectional and avoiding cross contamination. The modified layout should be submitted to FSSAI for approval along with the BOQ for civil and electrical work as per specifications mentioned. 1. Sample receiving area, a documentation room and office area (Unclassified). 2. Media preparation room (Unclassified) attached to sterilization room and washing (having sufficient space to store dry media/reagents and prepared media in refrigerators) 3. Sample preparation room (Class B/ISO 7) over pressure 45 pa having LAF 4. Inoculation room (Class B/ISO 7) over pressure 45 pa 2 nos (One having biosafety cabinet and another for automated systems/open lab) 5. -
Autoclave Quick Guide
Office of Biological Safety Autoclave Operation Quick Reference Guide Training: ALL users MUST undergo documented training for operation of the autoclave. Record each use of the autoclave in a log: Date, User ID, cycle type and nature of material in load Personal Protective Equipment (PPE) needed: ¾ Wear eye protection, lab coat, gloves along with heat resistant gloves. Rubberized apron, sleeve guards and face shield are recommended when autoclave is hot or splash risk is present. Hints and Precautions ¾ Become familiar with the manufacturer’s operations manual of your autoclave model(s). ¾ Plastics used for autoclaving MUST be labeled as autoclavable – otherwise the plastic will melt. ¾ Waste bags to be autoclaved must be loosely packed and not more than 2/3 filled. Steam must be able to penetrate to all contents of the bag. ¾ Sharps or pointed hard objects should not be placed directly into an autoclave bag; a thicker or rigid container must be used (such as a sharps container). ¾ Avoid overfilling an autoclave with loads or allowing a load to contact the chamber walls. ¾ Transferring waste contents from an overfilled bag to another bag should be avoided! This practice can lead to injury and/or exposure to contaminants. ¾ Do not leave an autoclave operating unattended for long periods of time; operation should be monitored periodically during a cycle in case of failure. ¾ Never autoclave solvents, combustible, volatile, flammable, radioactive or corrosive materials (e.g. ethanol, methanol, acids, bases, phenol) ¾ Remove extraneous items and combustible materials from around the autoclave exterior. Loading ¾ Follow manufacturer’s loading instructions for your autoclave model ¾ Transport loads on a cart and in secondary containers to reduce spills ¾ Clean item/container sterilization Loosen caps or lids to avoid dangerous pressure build-up during cycle Place containers in a tray and load the tray into the autoclave – this is easier to load and unload and will catch spills. -
Version 1.1 2015
BIOLOGICAL SAFETY MANUAL Version 1.1 2015 Environmental Health & Radiation Safety 3160 Chestnut Street, Suite 400 Philadelphia, PA 19104-6287 215-898-4453 [email protected] T ABLE OF C ONTENTS SECTION Page EMERGENCY CONTACTS ................................................................................ 4 INTRODUCTION ................................................................................................. 5 FREQUENTLY ASKED QUESTIONS ................................................................. 8 BIOLOGICAL RISK ASSESSMENT .................................................................. 10 BIOSAFETY LEVELS ........................................................................................ 14 ANIMAL BIOSAFETY LEVELS ......................................................................... 20 BIOSAFETY CABINETS ................................................................................... 25 COMMON LAB EQUIPMENT ........................................................................... 30 INFECTIOUS AGENTS ..................................................................................... 34 RECOMBINANT DNA ....................................................................................... 36 HUMAN SOURCE MATERIAL .......................................................................... 38 NON-HUMAN PRIMATE MATERIAL ................................................................ 41 SELECT AGENTS ............................................................................................. 44 BIOLOGICAL -
Pouring Plates from Prepared Bottled Media
Pouring Plates from Prepared Bottled Media Primary Hazard Warning Never purchase living specimens without having a disposition strategy in place. When pouring bottles, agar is HOT! Burning can occur. Always handle hot agar bottles with heat-protective gloves. For added protection wear latex or nitrile gloves when working with bacteria, and always wash hands before and after with hot water and soap. Availability Agar is available for purchase year round. Information • Storage: Bottled agar can be stored at room temperature for about six months unless otherwise specified. Never put agar in the freezer. It will cause the agar to breakdown and become unusable. To prevent contamination keep all bottles and Petri dishes sealed until ready to use. • Pouring Plates • Materials Needed: • Draft-free enclosure or Laminar flow hood • 70% isopropyl alcohol • Petri dishes • Microwave or hot water bath or autoclave 1. Melt the agar using one of the following methods: a) Autoclave: Loosen the cap on the agar bottle and autoclave the bottle at 15 psi for five minutes. While wearing heat-protective gloves, carefully remove the hot bottle and let it cool to between 75–55°C before pouring. This takes approximately 15 minutes. b)Water Bath: Loosen the cap on the agar bottle and place it into a water bath. Water temperature should remain at around 100°C. Leave it in the water bath until the agar is completely melted. While wearing heat- protective gloves, carefully remove the hot bottle and let it cool to between 75–55°C before pouring. c) Microwave: Loosen the cap on the agar bottle before microwaving. -
Monitoring Cell Cultures in Real Time in a Biochip
Ricardo Filipe Soares Serrão Degree in Cell and Molecular Biology Monitoring cell cultures in real time in a biochip Dissertation to obtain master’s degree in Biotechnology Supervisor: Professor Doctor João Pedro Conde, Department of Bioengineering, Instituto Superior Técnico, INESC-MN September 2019 ii Ricardo Filipe Soares Serrão Degree in Cell and Molecular Biology Monitoring cell cultures in real time in a biochip Dissertation to obtain master’s degree in Biotechnology Supervisor: Professor Doctor João Pedro Conde, Department of Bioengineering, Instituto Superior Técnico, INESC-MN September 2019 iii iv “We’re all stories, in the end. Just make it a good one, eh?” The Doctor v vi “Copyright” Monitoring cell cultures in real time in a biochip Ricardo Filipe Soares Serrão, FCT/UNL e UNL A Faculdade de Ciências e Tecnologia e a Universidade Nova de Lisboa têm o direito, perpétuo e sem limites geográficos, de arquivar e publicar esta dissertação através de exemplares impressos reproduzidos em papel ou de forma digital, ou por qualquer outro meio conhecido ou que venha a ser inventado, e de a divulgar através de repositórios científicos e de admitir a sua cópia e distribuição com objetivos educacionais ou de investigação, não comerciais, desde que seja dado crédito ao autor e editor. vii viii Acknowledgements There are not enough words to thanks to every person who direct or indirectly supported me throughout this last year. First, I have to express my gratitude o Prof. Dr. João Pedro Conde for his attention and availability during the whole year. It was a pleasure to work under his supervision and I’m thankful for the opportunity given to work in a motivational and challenging environment. -
Biohazardous Waste Handling for Eastern Kentucky University May 2018
Biohazardous Waste Handling For Eastern Kentucky University May 2018 Approved by The University Laboratory Safety Biohazard Subcommittee 1 Table of Contents Page Introduction 3-4 Definitions 5-6 Responsibilities and roles 7-9 Main body of document 10-17 Appendix 1 18-22 Autoclave procedures in SB 18-20 Autoclave procedures in Disney 218 21-22 Appendix 2 copy of IACUC form H: Use of hazardous agents 23 2 3 Introduction This document has been prepared to provide guidance to Eastern Kentucky University employees and students in the use and disposal of biohazardous materials in compliance with regulatory requirements. For this document “biohazardous waste” is defined as any discarded material which might include infectious laboratory materials or agents regulated by federal, state, and local authorities. At a minimum, the following categories should be considered as biohazardous waste materials: 1. Cultures and stocks of infectious biological agents, including laboratory waste, discarded live or attenuated viruses or related agents, culture dishes and other laboratory supplies used in the production or use of these agents, and any other related devices. 2. Human blood is a biohazardous waste. Human blood should treated in accordance with the “Eastern Kentucky University Bloodborne Pathogens Exposure Control Plan”. This plan can be found at the Risk Management Insurance/ Environmental Health and Safety website https://ehsrmi.eku.edu/occupational-safety. 3. Sharps: These are defined as needles, syringes, scalpels, etc., as well as any object sharp enough to puncture the skin (i.e. microscope slides, cover slips) that is used in the laboratories that could possibly come in contact with material that may be considered biohazardous waste. -
The Eppendorf Mechanical Pipettes Research® Plus and Reference 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance
APPLICATION NOTE No. 198 The Eppendorf Mechanical Pipettes Research® plus and Reference 2 – Fully Autoclavable, Easy Adjustment, Quick and Simple Maintenance Kornelia Ewald, Ulrike Gast, Eppendorf AG, Hamburg, Germany Abstract Research plus and Reference 2 pipettes are easy to clean safe to perform. This Application Note demonstrates the and maintain. Hence, routine maintenance can be easily special features of maintaining and cleaning Research performed by the user, saving valuable time. Readjust- plus pipettes and provides detailed information on ment of the pipette for liquids whose physical properties changing the pipette‘s adjustment. diff er signifi cantly from those of water is also easy and Introduction Research plus and Reference 2 are manual pipettes with Adjustment for specifi c liquids or altitude diff erent features and functional principles (e.g. one-button / During production, piston stroke pipettes are adjusted two-button operation). Fulfi lling the highest requirements, to distilled water under certifi ed measuring conditions. both pipettes have equal functionalities in terms of decon- To indicate the adjustment, all Research plus pipettes carry tamination, maintenance and adjustment. In order to meet an adjustment seal (Fig. 1). If necessary, adjustment for the high requirements of a modern laboratory, high quality specifi c liquids or for altitude can be carried out easily by piston stroke pipettes should be partly or fully autoclavable the user. The red adjustment seal, which is applied to the as well as UV resistant. adjustment opening following an adjustment, serves to The Eppendorf Research plus and Reference 2 pipettes can visualize a change of adjustment settings (Fig. 1). be decontaminated either by UV light or by autoclaving the entire instrument. -
Elara11 Autoclave Quick Installation Guide
OVER YEARS S ince 1925 Elara11 Autoclave Quick Installation Guide 1. Examine the outer carton and autoclave for any signs of damage. Immediately notify your dealer or Tuttnauer USA of any signs of damage. 2. To avoid injuries, lifting and carrying should be done by two people. • Lifting straps have been installed for your convenience. Lifting straps are for one time use only and should be removed and discarded after initial set up. 3. Place the sterilizer on a rigid level surface. The counter top or stand must be able to support 275lbs lbs Minimum 24”depth 4. The minimum depth of the counter top needs to be 24 inches. counter top required 5. It is mandatory to leave a minimum of 2” clearance between the back of the Elara11 and the wall. If located in a cabinet, the rear panel of the cabinet must be removed for proper air circulation. Failure to provide the needed clearance will result in failed cycles. 6. Side clearances should be a minimum of 2”. 7. Make sure all the feet are on the autoclave and none of them have been lost. 8. Connect the power cord to the socket on the rear of the autoclave; then plug it into the supply outlet. Power switch a. This unit requires a 230 volt 1 or 2 phase 15A supply. b. The acceptable operating voltage range is 220 to 235 volts. c. The installation of a Buck/Boost transformer (0.5KVA) may be required to meet the acceptable operating voltage. d. The supply outlet must be a properly grounded outlet. -
Cleaning and Decontamination Guide for Sartorius Pipettes
Operating Manual Cleaning and Decontamination Guide for Sartorius Pipettes Version 1 / 2018 / 11 Contents Contents 1 Cleaning and Decontamination in Pipette Maintenance . 4 2 Cleaning Guide . 5 2 .1 Cleaning the outer surface of the pipette (daily) . 5 2 .2 Cleaning the lower part of the pipette (every three months) . 5 3 Application-Specific Cleaning and Decontamination of Pipettes . 10 3 .1 When cleaning Sartorius pipettes for specific applications . 10 3 .2 Cleaning and decontamination reagent quick-guide . 11 3 .3 Cleaning agents and their activities . 11 3 .4 Cleaning procedures . 12 3 .5 Decontamination agents and their activities . 12 3 .6 Decontamination procedures . 13 4 Autoclaving Guide . 14 4 .1 Mechanical pipettes . 14 4 .2 Electronic pipettes . 14 4 .3 Autoclaving quick-guide . 15 4 .4 Drying of pipettes . 15 5 Summary of Pipette Parts . 16 5 .1 Mechanical pipettes parts and materials . 16 5 .1 .1 Tacta® mechanical pipette . 16 5 .1 .2 mLine® mechanical pipette . 17 5 .1 .3 Proline® Plus mechanical pipette . 17 5 .1 .4 Proline® mechanical pipette . 18 5 .2 Electronic pipette parts and materials: Picus and Picus® NxT . 18 6 Contact . 19 6 .1 Further information about pipette cleaning, decontamination and maintenance . 19 6 .2 Pipette maintenance, servicing or calibration . 19 Cleaning and Decontamination Guide for Sartorius Pipettes 3 Cleaning and Decontamination in Pipette Maintenance 1 Cleaning and Decontamination in Pipette Maintenance Pipettes are precision instruments whose performance can be significantly impacted if not adequately maintained . To maintain the level of purity that is critical in many laboratory applications, adequate cleaning and decontamination of pipettes is necessary . -
Purdue Biological Safety Manual," Please Complete and Return a Copy of This Form to Your Supervisor Or Designated Trained Individual
BIOLOGICAL SAFETY MANUAL Revised April 2004 TABLE OF CONTENTS Emergency Numbers iv Awareness Certification v Policy Statement 1 Scope and Application 1 Institutional Biosafety Committee 2 Biosafety Training 3 Medical Surveillance and Examinations 3 Hazard Identification 3 Protective Equipment 4 REM Services 4 Recombinant DNA (rDNA) 4 Biohazards 5 Routes of Exposure to Biohazards 5 Antigens 7 Principles of Biosafety 8 Laboratory Biosafety Level Criteria 9 Biosafety Level 1 9 Biosafety Level 2 10 Biosafety Level 3 12 Use of Animals 16 Vertebrate Animal Biosafety Level Criteria 16 Animal Biosafety Level 1 16 Animal Biosafety Level 2 17 Animal Biosafety Level 3 18 Bloodborne Pathogens Program 22 Decontamination and Disposal 22 Sterilization Procedures 23 Disposal Procedures 24 Sharps Handling Procedures 24 Clean and Contaminated Sharps Handling (Table) 26 Infectious Waste and Look-Alike Waste (Table) 27 Spills of Biohazardous Materials 27 ii The official version of this information will only be maintained in an on-line web format. Review the material on-line prior to placing reliance on a dated printed version. TABLE OF CONTENTS (Continued) APPENDICES Appendix A: Personal Protective Equipment (PPE) Policy & Hazard Assessment 29 Appendix B: Bio-Material Pick-up Certificate Disposal 30 Appendix C: Biological Safety Cabinets 31 Appendix D: Working Safely in a Biological Safety Cabinet 33 Ultraviolet Lamps 33 Biosafety Cabinet HEPA Filters 33 Additional Information 34 Appendix E: Biological Agent Risk Classification 36 NIH Agent Classification 37 Select Agents 47 Appendix F: Dangers of Cell and Tissue Culture Systems 50 Classification of Cell and/or Tissue Cultures According to Containment Level 50 Appendix G: Risk Classification For Oncogenic Agents 52 Criteria for Low Risk Oncogenic Agents 52 Criteria for Moderate Risk Oncogenic Viruses 52 Criteria for High Risk Oncogenic Viruses 53 Appendix H: Biosafety Reference Material 54 iii The official version of this information will only be maintained in an on-line web format. -
The Effect of Autoclave Resterilisation on Polyester Vascular Grafts
CORE Metadata, citation and similar papers at core.ac.uk Provided by Elsevier - Publisher Connector Eur J Vasc Endovasc Surg 18, 386±390 (1999) Article No. ejvs.1999.0891 The Effect of Autoclave Resterilisation on Polyester Vascular Grafts G. Riepe∗1, M. S. Whiteley2, A. Wente1, A. Rogge1, A. SchroÈ der1, R. B. Galland2 and H. Imig1 1Department of General, Vascular and Thoracic Surgery, General Hospital of Hamburg±Harburg, Germany; 2Department of Surgery, Royal Berkshire Hospital, Reading, U.K. Objectives: polyester grafts are expensive, single-use items. Some manufacturers of uncoated, woven grafts include instructions for autoclave resterilisation to be performed at the surgeon's own request. Others warn against such manipulation. Theoretically, the glass transition point of polyester at 70±80°C and the possible acceleration of hydrolysis suggest that autoclave resterilisation at 135°C might be a problem. Materials and methods: a DeBakey Soft Woven Dacron Vascular Prosthesis (Bard) and a Woven Double Velour Dacron Graft (Meadox) were autoclave-resterilised 0 to 20 times, having been weighed before and after sterilisation. Tactile testing was performed. Mechanical properties were examined by probe puncture and single-®lament testing, the surface was examined by scanning electron microscopy and the degree of hydrolysis by infra-red spectroscopy. Results: tactile testing revealed a change of feeling with increasing cycles of resterilisation. Investigation of weight, textile strength, single-®lament strength, electron microscopy of the surface and infra-red spectroscopy showed no change of the material. Conclusions: changes felt are presumably a surface phenomenon, not measurably affecting strength or chemistry of material after autoclave resterilisation. -
Transforming Plasmid DNA Into Electrocompetent Cells
Transforming plasmid DNA into electrocompetent cells 1. Clean and dry electroporation cuvettes throroughly on the cuvette washer. Chill on ice and allow to air dry. Use one cuvette for each DNA sample you are transforming. 2. Dialyze your DNA sample(s) using a nitrocellulose filter and DI water. • Fill a Petri dish with DI water. • Place a single nitrocellulose filter paper on the surface of the water – shiny side up. If you are dialyzing more than one sample, it helps to cut a small notch in the paper to serve as a “key”. This helps to identify/keep track of your samples. • Spot DNA samples onto the surface of the paper. Space out the samples a little bit because they will expand in volume as they dialyze. • Dialyze your sample for 10-15 minutes. *This step is particularly important if the DNA has undergone any previous manipulations that have introduced salts (adding buffers for ligation, restriction enzyme digestions, etc.). Too much salt in the DNA will cause your sample to arc when electroporating. This will kill the cells and significantly reduce the efficiency of transformation. If your sample arcs, it may still be worth while to plate your cells. However, it is likely that you will get very few (if any) colonies. You should repeat this sample. Main factors that can cause arcing - too much salt in your DNA, water on the outside of the cuvette, oil on the outside of the cuvette from handling it too much without gloves, too much salt in the cells. 3. Thaw electrocompetent cells on ice.