PRO-RO 6-Stage Reverse Osmosis System

Total Page:16

File Type:pdf, Size:1020Kb

PRO-RO 6-Stage Reverse Osmosis System PRO-RO 6-Stage Reverse Osmosis System System tested and certified by the Water Quality Association against NSF/ANSI Standard 58 for the reduction of substances specified on the performance data sheet. 3060 Performance Circle, Suite 2, Deland, FL 32724 877-842-1635, www.pelicanwater.com RevA: 0119 Introduction to the PRO-RO Congratulations on your purchase of the PRO-RO six stage reverse osmosis system. The PRO-RO features a four-stage prefilter, membrane and postfilter housed in a single cartridge. The final two stages consist of a granular activated carbon polishing filter and a calcite remineralizing filter. When properly maintained, this system will provide you with years of trouble-free service. The next sections contain important information on the proper care and maintenance of your system, please take a few minutes to read through this information. The cartridges in this system must be replaced on a regular basis to maintain efficiency and to ensure high water quality. These cartridges work together and must be replaced every 6-12 months. Any significant change in performance of the system should be investigated promptly to avoid secondary damage or deterioration to other parts of the system. Normally, the reverse osmosis membrane is replaced during an annual filter change. However, if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water, it could be time to replace the membrane. Pelican recommends replacing the membrane when TDS reduction falls below 85%. In order to ensure the system is functioning properly, a water sample must be sent in to Pelican every 6 months for a free di- agnosis of your membrane performance. To send a water sample, use two clean containers and fill one with 1/2 cup of tap water and the other with 1/2 cup of RO water. Clearly label each sample. Send the samples to Pelican Water Systems, 3060 Performance Circle, Suite 2, Deland, FL 32724, Attn: “Water Sample Testing” along with your contact information. Pelican will test the samples and contact you with the results. CAUTION: Improperly installed systems could result in water damage due to leaks or flooding. Proper installation of this system requires familiarity with standard sink plumbing and proper use of common hand and power tools. If you are not familiar with standard sink plumbing and proper use of common hand and power tools or have any difficulty with the installation of this system, consult a licensed professional, such as a contractor or plumber. NOTE: This system and installation must comply with state and local laws and regulations. Replacement Part Stage Description Interval Number 4-Stage Cartridge 1) 20 micron sediment prefilter 1-4 2) Granular activated carbon (GAC) prefilter 18 months 104863 3) Reverse osmosis membrane 4) Granular activated carbon postfilter Granular activated carbon (GAC) and calcite 5-6 6-12 months 104851 (remineralization) postfilter Pelican Water Systems 877-842-1635, www.pelicanwater.com 3 Pelican 1-Year Limited Warranty Pelican Water ("Pelican") warrants to the end user ("customer") that its metering pump tubing, Diaphragm Feed Or Injector Pump, POU Drinking Systems, Shower Filter, Install Kits and flow control switches ("Covered Items") will be free from defects in material and workmanship under normal use and service for a period of 1 year from the date of original purchase. Limitations and Responsibilities Pelican's obligation to the customer under these warranties shall be limited, at Pelican's option, to replacement or repair of Covered Items by these warranties, labor is not covered. These warranties do not cover replacement filter cartridges, elements or lamps. Prior to return or repair of Covered Items, the customer must obtain a return goods authorization number from Pelican by/at and at Pelicans option, return the Covered Items freight prepaid. Any Covered Item repaired or replaced under these warranties will be returned prepaid standard freight to the original point of shipment. Expedited freight options are available at customer expense. No warranty is made, and is explicitly excluded, with respect to defects or damages due to neglect, misuse, alterations, accident, misapplication, physical damage, or damaged caused by fire, acts of God, or freezing. These warranties apply only to the original registered owner so long as the owner owns/lives in the home in which the unit was originally installed. Customer must register their system with Pelican within 90 days of purchase* in order to obtain a warranty. Warranty will discontinue after the unit is removed from the location where it was originally installed. Warranty begins on the date of delivery of product to the customer. Improper maintenance of system (ie not replacing filters or media, for example) on time will be considered "neglect" and explicitly excluded from the warranty. Installation of any system on water conditions outside of or beyond the recommended specs of any system voids any warranty. Pelican gives this warranty to the original owner/customer in lieu of all other warranties, express or implied, including without limitation any implied warranties of merchantability or fitness for a particular purpose or treatment of certain water and hereby expressly disclaims all other such warranties. THE WARRANTIES PELICAN GIVES IN THE ABOVE PARAGRAPHS ARE EXCLUSIVE, PELICAN DISCLAIMS ALL OTHER WARRANTIES, EXPRESS, IMPLIED OR STATUTORY AND SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR IMPLIED WARRANTY OF WORKMANLIKE PERFORMANCE. Pelican's liability hereunder shall not exceed the cost of the product. Under no circumstances will Pelican be liable for any incidental or consequential damages or for any other loss, damage or expense of any kind, including loss of use, arising in connection with the installation or use or inability to use the Covered Items or any water treatment system the Covered Items are incorporated into. These warranties are governed by the laws of the state of Florida and may change at any time without notice.. *Failure by California and Quebec residents to complete the product registration form does not diminish their warranty rights. **For all orders placed on or after June 3rd, 2011. Pelican Water Systems 877-842-1635, www.pelicanwater.com 4 Performance Data Sheet System Performance This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances in water leaving the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 58. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disin- fection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. This system has been tested for the treatment of water containing pentavalent arsenic (also known as AS(V), As+5 , or arsenate) at concen- trations of </= 300 ppb. This system reduces pentavalent arsenic, but may not reduce other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual at the system outlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section of the Performance Data Sheet for further information. Testing was performed under standard laboratory conditions, actual performance may vary. Incoming water must be free of potential membrane foulants such as Iron, Hydrogen Sulfide and Manganese. Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage. Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed. Model Number: PRO-RO Avg Daily Production Rate: 67.76 L/d (17.9 gpd) Avg. Recovery: 30.7% Avg Efficiency: 17.8% Temperature: 4°C - 38°C (40°F - 100°F) Pressure: 2.81 - 5.62 kg/cm2 (40-80 psi) Influent Maximum Actual Average Challenge Allowable Minimum % Percent Concentration Concentration Reduction Reduction Arsenic (pentavalent) 50 ppb 10 ppb 98.1 99.0 Barium 10.0 mg/L ± 10% 2.0 mg/L 95.0 98.8 Cadmium 0.03 mg/L ± 10% 0.005 mg/L 94.0 98.3 Chromium 6 (Hexavalent) 0.3 mg/L ± 10% 0.1 mg/L 95.5 98.3 Chromium 3 (Trivalent) 0.3 mg/L ± 10% 0.1 mg/L 98.4 99.0 Copper 3.0 mg/L ± 10% 1.3 mg/L 95.0 98.4 Cysts Min 50,000/mL 110 counts/mL >99.99 >99.99 Fluoride 8.0 mL ± 10% 1.5 mL 87.0 93.8 Lead 0.15 mL ± 25% 0.010 mL 90.4 96.8 Radium 226/228 25 pCi/L ± 10% 5 pCi/L 95.0 98.8 Selenium 0.10 mg/L ± 10% 0.05 mg/L 94.4 97.9 Turbidity 11 ± 1 NTU 0.5 NTU 96.4 98.7 TDS (Total Dissolved Solids) 740 mL 187 mL 86.6 93.1 System Maintenance This reverse osmosis system contains a replaceable component critical to the efficiency of the system. Replacement of the reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to ensure the same efficiency and contaminant reduction performance. Feed water conditions may affect replacement intervals. Part Number Description Replacement Interval 104863 TF50, 4 stage cartridge 12 months 104851 5th stage inline post filter 6-12 months Pelican Water Systems 877-842-1635, www.pelicanwater.com 5 Arsenic Fact Sheet Arsenic (AS) is a natually occuring contaminant found in many ground waters.
Recommended publications
  • Water Treatment and Reverse Osmosis Systems
    Pure Aqua, Inc.® Water© 2012 TreatmentPure Aqua ,and Inc. ReverseAll Right sOsmosis Reserve dSystems. Worldwide Experience Superior Technology About the Company Pure Aqua is a company with a strong philosophy and drive to develop and apply solutions to the world’s water treatment challenges. We believe that both our technology and experience will help resolve the growing shortage of clean water worldwide. Capabilities and Expertise As an ISO 9001:2008 certified company with over a decade of experience, Pure Aqua has secured its position as a leading manufacturer of reverse osmosis systems worldwide. Goals and Motivations Our goal is to provide environmentally sustainable systems and equipment that produce high quality water. We provide packaged systems and technical support for water treatment plants, industrial wastewater reuse, and brackish and seawater reverse osmosis plants. Having strong working relationships with Thus, we ensure our technological our suppliers gives us the capability to contribution to water preservation by provide cost effective and competitive supplying the means and making it highly water and wastewater treatment systems accessible. for a wide range of applications. Seawater Reverse Osmosis Systems System Overview Designed to convert seawater to potable water, desalination systems use high quality reverse osmosis seawater membranes. The process separates dissolved salts by only allowing pure water to pass through the membrane fabric. System Capacities Pure Aqua desalination systems are designed to provide high
    [Show full text]
  • Conceptual Understanding of Osmosis and Diffusion by Australian First-Year Biology Students
    International Journal of Innovation in Science and Mathematics Education, 27(9), 17-33, 2019 Conceptual Understanding of Osmosis and Diffusion by Australian First-year Biology Students Nicole B. Reinkea, Mary Kynna and Ann L. Parkinsona Corresponding author: Nicole B. Reinke ([email protected]) aSchool of Health and Sport Sciences, University of the Sunshine Coast, Sippy Downs QLD 4576, Australia Keywords: biology, osmosis, diffusion, conceptual assessment, misconception Abstract Osmosis and diffusion are essential foundation concepts for first-year biology students as they are a key to understanding much of the biology curriculum. However, mastering these concepts can be challenging due to their interdisciplinary and abstract nature. Even at their simplest level, osmosis and diffusion require the learner to imagine processes they cannot see. In addition, many students begin university with flawed beliefs about these two concepts which will impede learning in related areas. The aim of this study was to explore misconceptions around osmosis and diffusion held by first-year cell biology students at an Australian regional university. The 18- item Osmosis and Diffusion Conceptual Assessment was completed by 767 students. From the results, four key misconceptions were identified: approximately half of the participants believed dissolved substances will eventually settle out of a solution; approximately one quarter thought that water will always reach equal levels; one quarter believed that all things expand and contract with temperature; and nearly one third of students believed molecules only move with the addition of external force. Greater attention to identifying and rectifying common misconceptions when teaching first-year students will improve their conceptual understanding of these concepts and benefit their learning in subsequent science subjects.
    [Show full text]
  • Circle Reverse Osmosis System
    CIRCLE REVERSE OSMOSIS SYSTEM KEY FEATURES Water Saving Technology – Patented technology eliminates backpressure The RC100 conforms to common in conventional RO systems making the Circle up to 10 times more NSF/ANSI 42, 53 and efficient than existing products. 58 for the reduction of Saves You Money – Conventional RO systems waste up to 24 gallons of Aesthetic Chlorine, Taste water per every 1 gallon of filtered water produced. The Circle only wastes and Odor, Cyst, VOCs, an average of 2.1 gallons of water per 1 gallon of filtered water produced, Fluoride, Pentavalent Arsenic, Barium, Radium 226/228, Cadmium, Hexavalent saving you water and money over the life of the product!. Chromium, Trivalent Chromium, Lead, RO Filter Auto Flushing – Significantly extends life of RO filter. Copper, Selenium and TDS as verified Chrome Faucet Included – With integrated LED filter change indicator. and substantiated by test data. The RC100 conforms to NSF/ANSI 372 for Space Saving Compact Design – Integrated rapid refill tank means more low lead compliance. space under the sink. SPECIFICATIONS Product Name H2O+ Circle Reverse Osmosis Water Filtration System Model / SKU RC100 Installation Undercounter Sediment Filter, Pre-Carbon Plus Filter, Post Carbon Block Filter (RF-20): 6 months Filters & Lifespan RO Membrane Filter (RF-40): 24 months Tank Capacity 6 Liters (refills fully in less than one hour) Dimensions 9.25” (W) x 16.5” (H) x 13.75” (D) Net weight 14.6 lbs Min/Max Operating Pressure 40 psi – 120 psi (275Kpa – 827Kpa) Min/Max Water Feed Temp 41º F – 95º F (5º C – 35º C) Faucet Flow Rate 0.26 – 0.37 gallons per minute (gpm) at incoming water pressure of 20–100 psi Rated Service Flow 0.07 gallons per minute (gpm) Warranty One Year Warranty PO Box 470085, San Francisco CA, 94147–0085 brondell.com 888-542-3355.
    [Show full text]
  • Refinery Wastewater Management Using Multiple Angle Oil-Water Separators
    REFINERY WASTEWATER MANAGEMENT USING MULTIPLE ANGLE OIL-WATER SEPARATORS Kirby S. Mohr, P.E. Mohr Separations Research, Inc. 1278 FM 407 Suite 109 Lewisville, TX 75077 Phone: 918-299-9290 Cell: 918-269-8710 John N. Veenstra, Ph.D., P.E., Oklahoma State University Dee Ann Sanders, Ph.D., P.E. Oklahoma State University A paper presented at the International Petroleum Environment Conference in Albuquerque, New Mexico, 1998 ABSTRACT In this work, an overview of oil-water separation, as used in the petroleum refining industries, is presented along with case studies. Discussions include: impact of solids, legal aspects, and differing types of systems currently in use, along with their advantages and disadvantages. Performance information on separators is presented with an emphasis on new multiple angle coalescing plate technology for refinery wastewater management. Several studies are presented including a large (20,000 US GPM flow rate) system recently installed at a major US refinery. The separator was constructed by converting two existing API separators into four separators, and adding multiple angle coalescing plates to increase throughput and efficiency. A year of operating experience with this system indicates good performance and few problems. Other examples provide information on separators installed in the United States and other countries. Keywords: Oil-water separator, multiple angle, coalescence, refinery, wastewater management, petroleum, coalescing plate technology BACKGROUND AND INTRODUCTION Oil has been refined for various uses for at least 1000 years. An Arab handbook written by Al-Razi, in approximately 865 A.D., describes distillation of “naft” (naphtha) for use in lamps and thus the beginning of oil refining (Forbes).
    [Show full text]
  • Reverse Osmosis As a Pretreatment of Ion Exchange Equipment at PSE
    Copyright Warning & Restrictions The copyright law of the United States (Title 17, United States Code) governs the making of photocopies or other reproductions of copyrighted material. Under certain conditions specified in the law, libraries and archives are authorized to furnish a photocopy or other reproduction. One of these specified conditions is that the photocopy or reproduction is not to be “used for any purpose other than private study, scholarship, or research.” If a, user makes a request for, or later uses, a photocopy or reproduction for purposes in excess of “fair use” that user may be liable for copyright infringement, This institution reserves the right to refuse to accept a copying order if, in its judgment, fulfillment of the order would involve violation of copyright law. Please Note: The author retains the copyright while the New Jersey Institute of Technology reserves the right to distribute this thesis or dissertation Printing note: If you do not wish to print this page, then select “Pages from: first page # to: last page #” on the print dialog screen The Van Houten library has removed some of the personal information and all signatures from the approval page and biographical sketches of theses and dissertations in order to protect the identity of NJIT graduates and faculty. ABSTRACT REVERSE OSMOSIS AS A PRETREATMENT FOR ION EXCHANGE AT PSE&G'S HUDSON GENERATING STATION by Steven Leon Public Service Electric and Gas Company's Hudson Generating Station has historically had problems providing sufficient high quality water for its two once through, supercritical design boilers. The station requires over 60 million gallons annually to compensate for system losses.
    [Show full text]
  • Selective Salt Recovery from Reverse Osmosis Concentrate Using Inter-Stage Ion Exchange Joshua E
    University of New Mexico UNM Digital Repository Civil Engineering ETDs Engineering ETDs 7-3-2012 Selective salt recovery from reverse osmosis concentrate using inter-stage ion exchange Joshua E. Goldman Follow this and additional works at: https://digitalrepository.unm.edu/ce_etds Recommended Citation Goldman, Joshua E.. "Selective salt recovery from reverse osmosis concentrate using inter-stage ion exchange." (2012). https://digitalrepository.unm.edu/ce_etds/8 This Dissertation is brought to you for free and open access by the Engineering ETDs at UNM Digital Repository. It has been accepted for inclusion in Civil Engineering ETDs by an authorized administrator of UNM Digital Repository. For more information, please contact [email protected]. Joshua E. Goldman Candidate CIVIL ENGINEERING Department This dissertation is approved, and it is acceptable in quality and form for publication: Approved by the Dissertation Committee: Dr. Kerry J. Howe , Chairperson Dr. Bruce M. Thomson Dr. Stephen E. Cabaniss Dr. Jerry Lowry i Selective Salt Recovery from Reverse Osmosis Concentrate Using Inter-stage Ion Exchange BY Joshua E. Goldman B.A., Anthropology, State University of New York at Stony Brook, 2000 M.S, Environmental Science, University of South Florida, 2007 DISSERTATION Submitted in Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy Engineering The University of New Mexico Albuquerque, New Mexico May, 2012 ii DEDICATION This dissertation is dedicated to the loving memory of my grandmother, Henriette Stein. iii ACKNOWLEDGMENTS This project was funded by the WateReuse Research Foundation. Resins were donated by ResinTech and Purolite. Francis Boodoo of ResinTech provided technical consultation for the pilot design.
    [Show full text]
  • The New Formula That Replaces Van't Hoff Osmotic Pressure Equation
    New Osmosis Law and Theory: the New Formula that Replaces van’t Hoff Osmotic Pressure Equation Hung-Chung Huang, Rongqing Xie* Department of Neurosciences, University of Texas Southwestern Medical Center, Dallas, TX *Chemistry Department, Zhengzhou Normal College, University of Zhengzhou City in Henan Province Cheng Beiqu excellence Street, Zip code: 450044 E-mail: [email protected] (for English communication) or [email protected] (for Chinese communication) Preamble van't Hoff, a world-renowned scientist, studied and worked on the osmotic pressure and chemical dynamics research to win the first Nobel Prize in Chemistry. For more than a century, his osmotic pressure formula has been written in the physical chemistry textbooks around the world and has been generally considered to be "impeccable" classical theory. But after years of research authors found that van’t Hoff osmotic pressure formula cannot correctly and perfectly explain the osmosis process. Because of this, the authors abstract a new concept for the osmotic force and osmotic law, and theoretically derived an equation of a curve to describe the osmotic pressure formula. The data curve from this formula is consistent with and matches the empirical figure plotted linearly based on large amounts of experimental values. This new formula (equation for a curved relationship) can overcome the drawback and incompleteness of the traditional osmotic pressure formula that can only describe a straight-line relationship. 1 Abstract This article derived a new abstract concept from the osmotic process and concluded it via "osmotic force" with a new law -- "osmotic law". The "osmotic law" describes that, in an osmotic system, osmolyte moves osmotically from the side with higher "osmotic force" to the side with lower "osmotic force".
    [Show full text]
  • Appendix A: Distillation and Reverse Osmosis Brine NOD, Phase I
    This document is part of Appendix A and includes Distillation and Reverse Osmosis Brine: Nature of Discharge for the “Phase I Final Rule and Technical Development Document of Uniform National Discharge Standards (UNDS),” published in April 1999. The reference number is EPA-842-R-99-001. Phase I Final Rule and Technical Development Document of Uniform National Discharge Standards (UNDS) Distillation and Reverse Osmosis Brine: Nature of Discharge April 1999 NATURE OF DISCHARGE REPORT Distillation and Reverse Osmosis Brine 1.0 INTRODUCTION The National Defense Authorization Act of 1996 amended Section 312 of the Federal Water Pollution Control Act (also known as the Clean Water Act (CWA)) to require that the Secretary of Defense and the Administrator of the Environmental Protection Agency (EPA) develop uniform national discharge standards (UNDS) for vessels of the Armed Forces for “...discharges, other than sewage, incidental to normal operation of a vessel of the Armed Forces, ...” [Section 312(n)(1)]. UNDS is being developed in three phases. The first phase (which this report supports), will determine which discharges will be required to be controlled by marine pollution control devices (MPCDs)—either equipment or management practices. The second phase will develop MPCD performance standards. The final phase will determine the design, construction, installation, and use of MPCDs. A nature of discharge (NOD) report has been prepared for each of the discharges that has been identified as a candidate for regulation under UNDS. The NOD reports were developed based on information obtained from the technical community within the Navy and other branches of the Armed Forces with vessels potentially subject to UNDS, from information available in existing technical reports and documentation, and, when required, from data obtained from discharge samples that were collected under the UNDS program.
    [Show full text]
  • Reverse Osmosis Brochure
    REVERSE OSMOSIS RO Storage Tanks High Purity Water Storage REVERSE OSMOSIS Amtrol invented the pre-pressurized water storage tank over 50 years ago and they are still considered the standard of the industry. These tanks feature a polypropylene liner and butyl diaphragm to prevent water from making contact with the metal tank for cleaner, fresher, better tasting water. All Amtrol RO tanks are manufactured in the USA at our ISO 9001:2008 registered facilities. REVERSE OSMOSIS Tanks • Provide water storage in reverse osmosis water systems. Polypropylene liner and butyl rubber diaphragm • Meet the most demanding specifications for are locked together with potable water. Amtrol’s unique hoop ring • Reliable diaphragm vs. bladder design. and groove design. • Individually tested for safety. ® Durable steel tank for • Available with Pro-Access stainless steel extra-long life. system connection. Typical Installation Cold Hot Drain Line Water Water Line Line Recirculation Line RO Water Membrane Feed Reverse Osmosis Water Storage Tank Pre Post Filter Filter Specifications and Tank Selection A Under Sink Models System Tank A B Tank Shipping Model Connection1 Tank Stand Model Volume Diameter Height Precharge Weight Number NPTM Color Type (Gallons) (Inches) (Inches) (psi) (lbs.) B (Inches) RO-2 140-32 2.0 8 13 ¼ Blue 5 Plastic 5 RO-2 140-653 2.0 8 13 ¼ Blue 20 Plastic 5 Standard RO-3 140S723 3.2 9 15 ¼ White 5 Plastic 7 RO-3 140S725 3.2 9 14 ¼ White 5 3 Bumps 7 A RO-4 141S343 4.4 11 15 ¼ Blue 5 Plastic 9 RO-4 141S344 4.4 11 15 ¼ White 5 Plastic 9 RO-4 141S351 4.4 11 15 ¼ White 5 3 Bumps/Plastic 9 B RO-4 141S352 4.4 11 15 ¼ Blue 5 3 Bumps/Plastic 9 RO-10 143-132 10.0 15 18 ¾ Blue 5 Plastic 20 1 Stainless Steel System Connection.
    [Show full text]
  • 21 Reverse Osmosis Treatment of PDWS 03-09
    PRIVATE DRINKING WATER IN CONNECTICUT Publication Date: March 2009 Publication No. 21: Reverse Osmosis Treatment of Private Drinking Water Systems Effective Against: inorganic contaminants such as: dissolved salts of sodium, dissolved (ferrous) iron, nitrate, lead, fluoride, sulfate, potassium, manganese, aluminum, silica, chloride, total dissolved solids, chromium, and orthophosphate. Also effective in removing some detergents, some taste, color and odor-producing chemicals, certain organic contaminants, uranium, and some pesticides. Not Effective Against: dissolved gases, most volatile and semi-volatile organic contaminants including some pesticides and solvents. Alone, reverse osmosis (RO) units are not recommended for treatment of bacteria and other microscopic organisms. How Reverse Osmosis Works A complete reverse osmosis system consists of a RO module, a storage tank, and a separate faucet. The module contains a semi-permeable membrane that allows water to selectively pass through and collect in the storage tank. The contaminants being treated by the RO unit are rejected and then washed off the membrane into a waste stream. It is not practical to treat all water entering a home with an RO system because about 75 percent of the water introduced is wasted. Thus, four gallons of raw water into the system produce about one gallon of treated water. This treated water comes out much slower than water from a regular tap, so a tank is used to store the treated water. The treated water is often used only for drinking and cooking. Each manufacturer’s RO units differ, but the time needed to produce one gallon of water ranges from 2-78 hours. The volume of wastewater produced by RO systems varies by make and model.
    [Show full text]
  • Seawater Desalination for Agriculture by Integrated Forward and Reverse Osmosis: Improved Product Water Quality for Potentially Less Energy
    Journal of Membrane Science 415–416 (2012) 1–8 Contents lists available at SciVerse ScienceDirect Journal of Membrane Science journal homepage: www.elsevier.com/locate/memsci Perspective Seawater desalination for agriculture by integrated forward and reverse osmosis: Improved product water quality for potentially less energy Devin L. Shaffer a, Ngai Yin Yip a, Jack Gilron b,1, Menachem Elimelech a,n a Department of Chemical and Environmental Engineering, Yale University, P.O. Box 208286, New Haven, CT 06520-8286, USA b Zuckerberg Institute for Water Research, Ben-Gurion University of the Negev, Sde Boker 84990, Israel article info abstract Article history: Seawater desalination for agricultural irrigation will be an important contributor to satisfying growing Received 21 March 2012 water demands in water scarce regions. Irrigated agriculture for food production drives global water Received in revised form demands, which are expected to increase while available supplies are further diminished. Implementa- 6 May 2012 tion of reverse osmosis, the current leading technology for seawater desalination, has been limited in Accepted 7 May 2012 part because of high costs and energy consumption. Because of stringent boron and chloride standards Available online 15 May 2012 for agricultural irrigation water, desalination for agriculture is more energy intensive than desalination Keywords: for potable use, and additional post-treatment, such as a second pass reverse osmosis process, is Seawater desalination required. In this perspective, we introduce the concept of an integrated forward osmosis and reverse Forward osmosis osmosis process for seawater desalination. Process modeling results indicate that the integrated Integrated process process can achieve boron and chloride water quality requirements for agricultural irrigation while Boron Agriculture consuming less energy than a conventional two-pass reverse osmosis process.
    [Show full text]
  • Osmosis and Osmoregulation Robert Alpern, M.D
    Osmosis and Osmoregulation Robert Alpern, M.D. Southwestern Medical School Water Transport Across Semipermeable Membranes • In a dilute solution, ∆ Τ∆ Jv = Lp ( P - R CS ) • Jv - volume or water flux • Lp - hydraulic conductivity or permeability • ∆P - hydrostatic pressure gradient • R - gas constant • T - absolute temperature (Kelvin) • ∆Cs - solute concentration gradient Osmotic Pressure • If Jv = 0, then ∆ ∆ P = RT Cs van’t Hoff equation ∆Π ∆ = RT Cs Osmotic pressure • ∆Π is not a pressure, but is an expression of a difference in water concentration across a membrane. Osmolality ∆Π Σ ∆ • = RT Cs • Osmolarity - solute particles/liter of water • Osmolality - solute particles/kg of water Σ Osmolality = asCs • Colligative property Pathways for Water Movement • Solubility-diffusion across lipid bilayers • Water pores or channels Concept of Effective Osmoles • Effective osmoles pull water. • Ineffective osmoles are membrane permeant, and do not pull water • Reflection coefficient (σ) - an index of the effectiveness of a solute in generating an osmotic driving force. ∆Π Σ σ ∆ = RT s Cs • Tonicity - the concentration of effective solutes; the ability of a solution to pull water across a biologic membrane. • Example: Ethanol can accumulate in body fluids at sufficiently high concentrations to increase osmolality by 1/3, but it does not cause water movement. Components of Extracellular Fluid Osmolality • The composition of the extracellular fluid is assessed by measuring plasma or serum composition. • Plasma osmolality ~ 290 mOsm/l Na salts 2 x 140 mOsm/l Glucose 5 mOsm/l Urea 5 mOsm/l • Therefore, clinically, physicians frequently refer to the plasma (or serum) Na concentration as an index of extracellular fluid osmolality and tonicity.
    [Show full text]