Understanding Arc-Flash, Arc-Blast Physics Can Save Your Life

Total Page:16

File Type:pdf, Size:1020Kb

Understanding Arc-Flash, Arc-Blast Physics Can Save Your Life THE Providing Electrical Solutions Worldwide VOL V october 2013 INSIDE THIS ISSUE Understanding Arc-Flash, Arc-Blast Physics Can Save Your Life By Ashley McWhorter, President, CBS ArcSafe LIKE ANY ENERGY source, an electrical circuit is a And what does the smart person do when ticking bomb. It’s simply waiting for the right they come upon a ticking box? They turn conditions to blow. A twisted pole, faulty inter- around and go the other way, of course. And lock, and enough energy will turn an electrical call the authorities. firecracker into a mortal lightning strike. Vacuum Bottle Engineering Expert Joins Vacuum Interrupters, Inc. GROUP CBS AND VACUUM INTERRUPTERS, INC. are proud to announce that John Toney has accepted a staff engineer position with Vacuum Interrupters, Inc., a supplier of replacement vacuum interrupter parts, components, and the industry’s first predictive field-testing system for vacuum interrupters. “We’re thrilled to have such a prominent vacuum interrupter engineer join our staff,” said Julia Neves, vice pres- ident and operations manager at Vacuum Interrupters, Inc. (Carrollton, Texas), a Group CBS company. “Vacuum Interrupters, Inc. has positioned itself as the ‘go-to’ supplier for vacuum interrupter testing and replacement parts. Toney’s experience will be invaluable in maintaining our leading position in the medium-voltage, vacuum interrupter- based technology markets.”Toney graduated from the University of Michigan, Ann Arbor, with bachelor’s degrees in both astronomy and electrical engineering. Following graduation, Toney accepted a position with General Electric’s www.GroupCBS.com Message from the CEO THE VIEW FROM FLIGHT LEVEL 410 By Finley Ledbetter, CEO, Group CBS Group CBS Continues Expansion on All Fronts Group CBS affiliate companies add key personnel, continue to evaluate new locations in Northeast and around the U.S. I CANNOT believe it has been 36 years since true and fast. And we are growing in all Astro Controls has let a contract to I walked into that room at UTA and areas at a time when others are not. double the warehouse in Irving, Texas, interviewed for an intern’s engineering Why is that? I guess if you understand allowing us to better organize inven- position at Multi Amp. I guess I should what I wrote above, you get it. tory and bring all our material under be very happy no one else showed up. Now around the Group, things are hop- one roof. Everyone needs to look back and put a ping. Western Electrical Services (WES) CBS ArcSafe has hired Tim Kelly check mark next to that spot that helped has hired a new salesman, Justin Sandlin, to help kick-start that business in the make them what they are today. I have a to help bolster the Intermountain Region. Northeast. Tim has spent the last 25 few of them. That day at UTA. Meeting Let’s welcome him and hope for good years working as outside sales for Satin Joni. And all the days my kids hit the things out west. in the New York area. He will work side ground. And, oh yeah, let’s not forget In the East, we are looking to acquire by side with Lou to help build this mar- the day I called Ray and said, “Meet me and build a new service shop. Look for ket for CBS ArcSafe. for lunch. I have something to talk with more on this in the next BreakerBuzz. For Jeff Voytek has joined Group CBS and you about.” now, let me just say that our long-term will head up the end-service shop setup Where am I going with this, you ask? plans call for us to have a full-service/ and build-out. Welcome aboard, Jeff. I’m not sure, but it is certainly the truth heavy-service shop in the Northeast by Circuit Breaker Analyzer (CBA) has that surrounding ourselves with great the end of 2015. made great progress. We are on our third people and being very lucky are great advantages in life and business. I have noticed that the more hours I put in, the Let’s be the guys who do what we say we will do. luckier I get. And the smarter the guys Let’s be the guys with the products and services around me, the smarter I get. In earlier issues of BreakerBuzz, I have that work and do as promised. written that you should surround your- self with talent, work hard, play hard, and Bill Stephens has accepted the posi- release and have sold several accounts. take care of your family. But now I add tion as president of Circuit Breaker Sales CBA will be adding market and cus- this one: Let’s be the guys who do what & Repair (CBS&R), and we have started tomer support structure to help in the we say we will do. Let’s be the guys with to break ground on a warehouse expan- near future. Natalie, Andrew, and Mike the products and services that work and sion. Bill will oversee all operations for have been working tirelessly and have do as promised. Let’s be the guys who Group CBS in the Gulf Coast region developed a great new CBA version for do not have an evil agenda. Let’s be the and help us take CBS&R and Reliable Windows 7. Look for that new product guys who others say, “Hey, there has to Electrical Testing Services (RETS) in release before the NETA show in March be something wrong over there because new directions. Bill plans to relocate to 2014. It will be a real nice addition to they’re too good.” But there is not any- Houston and has started to bring in some the original iOS version. We are going to thing wrong at Group CBS. We are sailing new staff and ideas to CBS&R and RETS. give the Windows 7 version for free to all 2 october 2013 THE Breaker Buzz Call 972.250.2500 who have already purchased an iOS version. This will be quite a bargain. AMC Introduces Revolutionary Panelboard Group CBS is working on another The new UL-508A-certified heat trace panelboard serves the natural gas, petroleum, pipeline, acquisition in the Southeast, adding and chemical process industries. another service shop to our ban- ADVANceD MOTOR CONTROls, a Group CBS company which makes the ProCS™ Series a perfect solution. ner. This acquisition should be done that specializes in electrical equipment manufactur- For shorter runs and more simplified applications, and announced before the next ing, remanufacturing, and life extension services, is we offer an economical solution, the ProC™ Series BreakerBuzz. proud to announce its new UL-508A-certified Heat Panelboards, which use a standard 30-mA ground Vacuum Interrupters (VI) has Trace Panelboards (HTP). Advanced Motor Controls’ fault circuit breaker. ProC™ and ProCS™ Series HTP are designed for use Advanced Motor Controls’ Advanced Heat been selling MAC (magnetron in natural gas, petroleum, chemical processing, and Trace Panels can be fabricated as floor or wall- atmospheric condition) sets and related pipeline operations. mounted enclosures, and include a panelboard service coast to coast and over- “Advanced Motor Controls is proud to become one distribution center, power distribution block, con- seas. We have learned a lot and of the few UL-certified U.S. suppliers of heat trace trol power transformer, and microprocessor-based are improving our hardware and panelboards in support of the U.S. natural gas and ground fault relay or standard 30-mA ground fault model. Utilities, refineries, chem- domestic energy markets,” said David ical plants, and service providers Muir, business manager of Advanced have purchased the sets, and we Motor Controls. “With UL-508A cer- see a steady stream of data coming tification, our energy customers and from the field. Look for a release of their electrical suppliers can be con- a few new products for both MAC fident that our heat trace panelboards and Vacuum Interrupters Inc. include only UL-listed components (RVI) before the next BreakerBuzz. and comply with all UL, NEMA, and NEC design criteria in addition to Join me in welcoming Finley some of the fastest alarm condition Ledbetter III to the MAC team after response times available today.” a two-year internship and earning Heat tracing maintains process Advanced Motor controls offers the ProcS™ and the a NETA level 2 card at WES. FL3 Proc™ Series Heat trace Panelboards. temperatures for reservoirs and has relocated to RVI and will head piping that must store or transport substances circuit breaker. The panel has options for an inte- up field-service demo and training that solidify at ambient temperatures. Heat Trace grated main circuit breaker, main contactor, alarm for MAC products. Finley, a 2011 Panelboards monitor electrical resistance in the relay, alarm horn, door disconnect, hand/off/auto BSEE graduate of Texas Tech’s engi- heat-tracing system. Typically, heat-tracing systems selector switch, and push-to-test lights on the neering school, is working at RVI include electric trace heaters, support components, panel front. Taken together, these features mean learning the ins and outs of MAC and other electric heating devices that are external that Advanced Motor Controls’ Heat Trace Panels field assessment and the particulars to the Heat Trace Panelboard. When the HTP detects offer advanced features common to high-priced of removal and installation of vari- an impedance change, it triggers a response of the panelboards with minimal cost and lead-time. ous vacuum interrupters under Jerod external components in the heat-tracing system. Advanced Heat Trace Panels come in a variety Advanced Motor Controls offers two lines of of NEMA-rated enclosure types, including NEMA Day’s watchful eye.
Recommended publications
  • Is Anyone Doing an Arc Flash Analysis?
    Get your FREE subscription PRINT or DIGITAL page 33 A CLB MEDIA INC. PUBLICATION • OCTOBER 2009 • VOLUME 45 • ISSUE 9 T&B_lug_EB_Oct09.indd 1 9/30/09 11:09:38 AM In the rush to label everything, is anyone doing an arc flash analysis? Also in this issue... • LED parking lot lighting (Page 7) • WorldSkills 2009 wrap-up (Page 16) • New guy on the block: PM # 40063602 The Running Man (Page 25) Nexans_EB_Oct09.indd 1 10/7/09 1:20:10 PM EB_Oct09_1-22.indd 1 10/13/09 2:34:26 PM Standard_EB_Oct09.inddEB_Oct09_1-22.indd 2 1 9/29/0910/6/09 2:06:3512:50:25 PM PM lectrical FROM THE EDITOR E usiness THE AUTHORITATIVE VOICE OF BCANADA’S ELECTRICAL INDUSTRY Putting smart grid October 2009 • Volume 45 • Issue 9 into better perspective am officially declaring that ‘smart grid’ should no longer be and the wind isn’t always blowing! We need to infuse our electrical spelled with any capitalization. Although IEC and NEMA infrastructure with the intelligence it needs to monitor, measure, ELECTRICAL BUSINESS is the magazine of the Canadian electrical I continue to capitalize the thing, I believe this just makes bill, etc., electricity from all kinds of other sources, as well as be able industry. It reports on the news and publishes articles in a manner the whole notion a little too high-and-mighty for my liking. to ramp up tried-and-true standby methods (like hydro, nuclear, that is informative and constructive. It’s time smart grid was brought down from the 30,000-ft etc.) when shortfalls are anticipated.
    [Show full text]
  • Arc Flash Resistant Equipment
    Arc Flash Resistant Equipment Course No: E02-019 Credit: 2 PDH Velimir Lackovic, Char. Eng. Continuing Education and Development, Inc. 22 Stonewall Court Woodcliff Lake, NJ 07677 P: (877) 322-5800 [email protected] ARC FLASH RESISTANT EQUIPMENT Arc flash resistant equipment may be described as the equipment made to withstand the impact of internal arcing fault by meeting the testing requirements of IEEE Guide C37.20.7-2007. In the 1970s, an interest started in Europe in assessing electrical equipment under internal arcing, which led to the IEC standard. This research spread through North America and was used as a foundation for the EEMAC G14-1 procedure. The development of the IEEE standard heavily relies on Annex AA of the IEC standard and adopts many of the refinements originated in the EEMAC G14-1 procedure. IEC 62271 - 200 defines the requirements for factory assembled metal- enclosed switchgear and control gear for alternating currents at a rated voltage above 1 kV and up to and including 52 kV. It includes indoor and outdoor assemblies and frequencies up to and including 60 Hz. The arc-resistant construction can be used for: - Medium voltage switchgear - Low voltage switchgears - Medium voltage MCCs - Low voltage MCCs. ARC FLASH HAZARD CALCULATION IN ARC-RESISTANT DEVICES It is well known that even if arc-resistant devices are used, additional power system protection, like AFD and differential protection systems, need to be provided to decrease the arcing time and incident energy release. The computation of incident energy, hazard risk category and PPE category for arc-resistant devices and their reductions uses the same methodology as for typical electrical equipment.
    [Show full text]
  • Arc Flash Hazards Analysis
    ARC FLASH HAZARDS ANALYSIS by ZHENYUAN ZHANG Presented to the Faculty of the Graduate School of The University of Texas at Arlington in Partial Fulfillment of the Requirements for the Degree of DOCTOR OF PHILOSOPHY THE UNIVERSITY OF TEXAS AT ARLINGTON December 2015 Copyright © by Zhenyuan Zhang 2015 All Rights Reserved ii Acknowledgements I would like to express deep gratitude to my supervising professor, Dr. Wei-Jen Lee for his guidance, encouragement, patience, and support throughout my entire doctoral program at the University of Texas at Arlington. He encouraged me to not only grow as an electrical engineer but also grow as independent and creative thinker. Also, I would like to take this opportunity to convey my sincere gratitude to Dr. Lee for extending his support and guidance leading me to complete this dissertation. I am blessed to have adviser like him. I would like to thank my doctoral dissertation committee members: Dr. William E. Dillon, Dr. Rasool Kenarangui, Dr. David A. Wetz, and Dr. Ali Davoudi. Thanks for their valuable and detailed instruction, suggestions and review. I would also like to thank for the members of the Energy Systems Research Center. Thank for all of their helps and the friendship in last six and half years. They are not only the team members in my researches but also bring me laugh, happiness, and inspirations during the stressful graduate life. Also, I want to express my great thanks to Mr. Lydon Lee, who helps me a lot on the dissertation revision. I wish to thank for all the Steering Committee and Technical Advisory Committee members of IEEE/NFPA collaboration on arc flash phenomena research project.
    [Show full text]
  • Arc Flash Detection Through Voltage/Current Signatures
    ARC FLASH DETECTION THROUGH VOLTAGE/CURRENT SIGNATURES A Thesis Submitted to The College of Graduate Studies and Research In Partial Fulfillment of the Requirements For the Degree of Master of Science In the Department of Electrical and Computer Engineering University of Saskatchewan, Saskatoon, Saskatchewan, Canada By GEOFF BAKER Copyright Geoffrey J. Baker, September, 2012. All rights reserved. PERMISSION TO USE In presenting this thesis in partial fulfilment of the requirements for a Masters degree from the University of Saskatchewan, I agree that the Libraries of this University may make it freely available for inspection. I further agree that permission for copying of this thesis in any manner, in whole or in part, for scholarly purposes may be granted by the professor who supervised the my thesis work or, in their absence, by the Head of the Department or the Dean of the College in which my thesis work was done. It is understood that any copying or publication or use of this thesis or parts thereof for financial gain shall not be allowed without my written permission. It is also understood that due recognition shall be given to me and the University of Saskatchewan in any scholarly use which may be made of any material in my thesis. Requests for permission to copy or to make other use of material in this thesis in whole or part should be addresses to: Head of the Department of Electrical and Computer Engineering 57 Campus Drive University of Saskatchewan Saskatoon, SK Canada, S7N 5A9 i ABSTRACT Arc Flash events occur due to faults in electrical equipment combined with a significant release of energy across an electrical arc.
    [Show full text]
  • SEL Arc-Flash Detection (AFD) Questions and Answers Contents
    SEL Arc-Flash Detection (AFD) Questions and Answers Contents Arc-Flash Basics What is an arc-flash hazard? . 4 What causes an arc flash? . 4 What elements must be present for an arc-flash event to occur? . 4 How does a protective relay help mitigate incident energy from an arc-flash event? . 4 What role do air gaps play in an arc flash? . 4 Are there other dangers in an arc-flash event besides intense heat and light? . 5 How much light is produced in an arc flash? . 5 How is the current determined in an arc-flash event? . 5 Solutions Overview How does SEL arc-flash technology mitigate arc-flash hazards? . 5 How does SEL sensor-based AFD technology work? . 5 Which products represent the SEL family of sensor-based AFD products? . 6 Configuration How is arc-flash mitigation configured with SEL protective relays? . 6 What is the maximum number of arc-flash sensors I can connect to an SEL relay? . 6 Light Sensors Why do I need light sensors? Isn’t the overcurrent element in a protective relay sufficient to sense when an arc-flash event occurs? . 7 How does the SEL light-sensing technology work? . 7 How do I know that the arc-flash-sensing technology will continue to work over time? Do I test the sensors periodically to verify that they’re working? . 7 How do I test the arc-flash sensors during commissioning to verify that they’re in working order? . 7 When should I use the bare-fiber sensor vs . the point sensor? Can I mix and match them on the same relay? .
    [Show full text]
  • Arc Flash Standards and Arc Flash Risk Reduction Technologies
    Arc Flash Standards and Arc Flash Risk Reduction Technologies Solutions that reduce arc flash injuries and equipment damage Bob Yanniello VP of Engineering Electrical Systems & Services Eaton © 2015 Eaton. All Rights Reserved.. Arc flash safety • On average, only 1 out of every 240 workplace accidents involve electricity (0.4%) • However, 1 out of every 24 work related deaths involve electricity (4%) This underlines the need for strong emphasis on Electrical Safety © 2015 Eaton. All Rights Reserved.. 2 Arc flash safety © 2015 Eaton. All Rights Reserved.. 3 Why is an arc a hazard? Molten Metal 35,000 °F Pressure Waves Sound Waves Shrapnel Copper Vapor: Solid to Vapor Expands by Hot Air-Rapid Expansion 67,000 times Intense Light © 2015 Eaton. All Rights Reserved. 4 Unfortunately – bad things can and do happen © 2015 Eaton. All Rights Reserved.. 5 Unfortunately – bad things can and do happen © 2015 Eaton. All Rights Reserved.. 6 Unfortunately – bad things can and do happen © 2015 Eaton. All Rights Reserved.. 7 Potential causes of arc flash events • Poorly maintained equipment • Poor operating environments • Conductive objects left in equipment • Dropping conductive objects into equipment • Insulation breakdown (MV typically) • Animal ingress © 2015 Eaton. All Rights Reserved. 8 Codes and Standards Related to Arc Flash Safety © 2015 Eaton. All Rights Reserved.. New OSHA electrical safety final rule published • OSHA does not support the NFPA 70E “table methods” in terms of estimating incident energy • Additional language recognizes the latest NFPA 70E consensus standards should be the foundation for safety standards. © 2015 Eaton. All Rights Reserved. 10 New OSHA electrical safety final rule published Key changes • The employer must assess the workplace to identify workers exposed to flame or electric-arc hazards.
    [Show full text]
  • Salisbury Electrical Safety L.L.C
    SALISBURY ELECTRICAL SAFETY L.L.C. Safety is Our Business. Let Us Make it Yours. Electrical Safety Protection PRO-WEARTM ARC FLASH PROTECTION CLOTHING AND PERSONAL ELECTRICAL SAFETY PROTECTIVE EQUIPMENT w w w . a r c s a f e t y . c o m 1 One Stop Shop SALISBURY Your complete safety solution. We have everything you need to meet the NFPA 70E Standard and OSHA 29 1910.269 Regulations. The NFPA 70E Standard and OSHA Regulations have been established to protect workers from electrical shock and arc flash hazards. For example, the NFPA 70E Standard specifies areas in which arc flash protection is required for workers. All personnel within the defined boundaries must wear specified protective equipment, even on circuits as low as 50 volts. The NFPA 70E Standard and OSHA Regulations MUST be met, and Salisbury has made it easy to meet them. We take your safety seriously. We have you covered from head to toe. 2 SALISBURY 7520 North Long Avenue Skokie, IL 60077-3226 l U.S.A. Toll Free:877.406.4501 l U.S.A. Toll Free Fax:866.824.4922 CONTENTS FACE, HEAD & NECK PROTECTION & ACCESSORIES PRO-SHIELDTM 7 Replacement Lenses 8 Replacement Brackets 9 AFHOODs & Nets 10 HRC2 Face, Head & Neck Protection Kit 11 NEW PIC PRO-AIRTM PRODUCTS 12-14 COMING PRO-WEARTM ARC FLASH PROTECTION CLOTHING & KITS Quick Reference Chart 16 Sizing & Material Weights 17 PRO-HOODTM 19 Coats 20 Bib Overalls 21 Coveralls & Kit 22-23 Jacket, Overpants & Kit 24-25 HRC2 8, 12, 20 cal/cm2 Kit 26 HRC3 31 cal/cm2 Kit 27 HRC4 40 cal/cm2 Kit 28 HRC4 55 & 75 cal/cm2 Kit 29 HRC4 100 cal/cm2
    [Show full text]
  • Welding Safety Objectives
    Welding Safety Objectives Identify hazards in the shop Learn about protective clothing Understand the dangers of fire, electricity, fumes, cylinders, and machines Explain how to avoid potential hazards in the shop Dangers in the shop Your personal mind set Physical factors Heat, sparks, hot metal, flammable materials Electricity Machines and moving vehicles Compressed gases Loud noises Fumes Personal factors things you can change Having a bad attitude Stressed out Feeling sick or tired Drug usage Lack of job knowledge Lack of wisdom and age (fooling around or acting immature) Physical factors things you don’t have control over Equipment failure Time of day Tidying (cleaning up so that you and the people around you are less likely to slip, trip, and be burnt.) Protective clothing In the shop, there will be other people working around you. That is why before you enter the shop make sure you are properly dressed. This includes: 1. Safety glasses (protect eyes from hot metal, sparks, equipment failures) 2. Leather boots (protect feet from hot metal, and falling objects) 3. Jeans with NO cuffs or frayed parts that go OVER your boots (protect legs and ankles) 4. Cotton shirt (protects the top half of you) DO NOT COME UNPREPARED, you will not be allowed to enter the shop What is welding? Welding is joining two or more metals together permanently. The three types of welding you will be introduced to are SMAW (shielded metal arc welding, or stick), GMAW (gas metal arc welding, or MIG), and GTAW (gas tungsten arc welding, or TIG). SMAW GMAW GTAW These three processes use an electric arc to create heat that melts the metal into the base metal.
    [Show full text]
  • Arc Modeling Challenges
    Rümpler Ch. et al.: Arc Modeling Challenges Arc Modeling Challenges Rümpler Ch.1, Narayanan V.R.T.2 1Eaton, 1000 Cherrington Pkwy, Moon Township, PA 15108, USA 2Eaton, Bořivojova 2380, 252 63 Roztoky, Czech Republic [email protected] Modeling of arcing phenomena has evolved towards becoming a state-of-the-art tool, supporting the de- sign process of power distribution equipment in low-, medium-, and high-voltage applications. Modeling provides a better understanding of the physical processes within the devices which is needed in order to enhance product performance and mitigate risks in the development cycle. In this contribution, modeling challenges related to some of these applications are discussed: a) the calculation of thermodynamic and transport properties, b) the modeling approach for contact arm motion during arc interruption in low- voltage molded case circuit breakers (MCCB’s), c) the model approach for arc flash events in medium- voltage (MV) switchgear. Keywords: arc simulation, plasma transport properties, circuit breaker, switchgear 1 INTRODUCTION eling approach for arc flash in medium- Arcing phenomena are crucial in various ap- voltage switchgear in section 5. plications in the power distribution system. Arcs are used either as a switching element, 2 SIMULATION APPROACH e.g. in circuit breakers with electromechanical A modeling approach has been developed that contact systems or arcs occur as a fault event, covers the highly nonlinear physical processes e.g. as arc flash in low-voltage or medium- during high-current arcing [2]. voltage switchgear. Due to the complex non- linear processes associated with arcing phe- nomena, modeling has several useful aspects.
    [Show full text]
  • YOUR SINGLE SOURCE for INDUSTRIAL ELECTRICAL PROTECTION His World in Your Hands, Your Safety in Ours
    YOUR SINGLE SOURCE FOR INDUSTRIAL ELECTRICAL PROTECTION His world in your hands, your safety in ours. Come Home Safe. Your profession relies on you to operate safely among electrical and arc flash hazards. You can rely on Salisbury to provide head-to-toe PPE solutions to protect you from harm. We are committed to putting the best products on the market and standing behind them with a name that has been trusted for over 150 years. World leader in electrical safety PPE Lives depend on you. Protect yourself with Salisbury www.SalisburybyHoneywell.com | 877.406.4501 © 2015 Honeywell International Inc. CONTENTS SALISBURY ASSESSMENT SOLUTIONS (SAS) PERSONAL ELECTRICAL SHOCK PROTECTION & ACCESSORIES Salisbury Assessment Solutions (SAS) . 6-13 Protective Rubber Equipment Labeling Chart . .. 42 Personal Electrical Shock Protection Information . 43 Low Voltage Molded Sleeves . 44 Rubber Insulating Gloves . 45 Leather Protectors & Liners . 46 FACE, HEAD AND NECK PROTECTION & ACCESSORIES Glove Kits . 47 Arc Flash Protection Gloves . 47 AS1000 – AS2000 Series Face Shields . 15-24 Glove Accessories . 48, 55 Replacement Lenses . .. 15, 17, 19 Dielectric Footwear . 48 Replacement Brackets . 20 Protective Blankets, Matting & Accessories . 49-50 Protective Nets & Glasses . 20 Rescue Hook & Static Discharge Stick . 51 HRC2 Face, Head & Neck Protection Kit . 21 Clampsticks & Switch Sticks . 52 AFHOOD’s . 22 Grounding Equipment . 53-54 NEW 40 cal/cm2 Lift Front Hood . .. 22-23 Voltage Detectors, General Cleaners & Air Flow Hood Systems . 24 Glove Dust . 55 Important Safety Information for PPE . 56 PRO-WEAR® ARC FLASH PROTECTION CLOTHING & KITS INSULATED HAND TOOLS & KITS Sizing & Material Weights . .26 Salisbury Insulated Products . 57 Quick Reference Chart & CE Information .
    [Show full text]
  • High-Voltage Assessment and Applications—Part 2
    FEATURE HIGH-VOLTAGE ARC FLASH ASSESSMENT AND APPLICATIONS—PART 2 BY ALBERT MARROQUIN, PE, ETAP; ABDUR REHMAN, PE, Puget Sound Energy; and ALI MADANI, AllumiaX Engineering Part 1 of this article, which was the cover story in the previous issue of NETA World, explored the need for high-voltage arc fl ash (HVAF) assessment to protect utility workers who are exposed to voltages above 15kV. It also compared various methods to calculate the incident energy from HV and MV electric arcs. Analyzing the results demonstrated that several methods can be used to calculate the incident energy generated by open-air, line-to-ground arc faults for systems within the range of NESC Table 410.2 and Table 410.3. Part 2 discusses key driving factors that directly network and protective device information. aff ect arc fl ash incident energy, along with PPE This article illustrates the importance of considerations for various scenarios. A real-life performing a HVAF assessment for utility case study drives home the importance of high- applications and highlights the benefi ts of using voltage arc fl ash studies for utility applications. a tool capable of limiting human error factors Traditionally, all existing HVAF simulation from data transfer across diff erent platforms by programs (e.g., ARCPRO, Duke HFC) require performing incident energy calculations along a manual, time-consuming process to calculate with network short-circuit currents (phase and incident energy because they do not contain sequence) and protective device operating time. 58 • FALL 2019 HIGH-VOLTAGE ARC FLASH ASSESSMENT AND APPLICATIONS — PART 2 FEATURE PROTECTION SYSTEM CHARACTERISTICS Th e three most important driving factors that directly aff ect arc-fl ash energy are the short- circuit current, the gap between conductors, and the duration of the arc.
    [Show full text]
  • Concerned About Arc-Flash and Electric Shock?
    Concerned about arc-flash and electric shock? White Paper Safety technology Introduction Want to comply with Electrocution is the obvious danger faced by NFPA 70E CSA Z462? anyone working on or near live electrical equip- ment and it is clearly important to understand How can IR Windows help? shock hazards and wear appropriate protection. However, most electrical accidents are not the Infrared thermography has become a result of direct electric shocks. A particularly well-established and proven method for hazardous type of shorting fault—an arc fault— inspecting live electrical equipment. To occurs when the insulation or air separation carry out tests, the thermographer usu- between high voltage conductors is compro- ally works with live energized equipment mised. Under these conditions, a plasma arc—an and requires a clear line of sight to the “arc flash”—may form between the conductors, target. Thermographers must therefore unleashing a potentially explosive release of be especially aware of the hazards, the thermal energy. legislation and safety issues, and the An arc flash can result in considerable damage to equipment and serious injuries to techniques and equipment best suited nearby personnel. A study carried out by the US to minimizing the risks when working in Department of Labor found that, during a 7-year these dangerous environments. period, 2576 US workers died and over 32,000 suffered injuries from electrical shock and burn injuries. 77 % of recorded electrical injuries were due to arc flash incidents. According to statistics compiled by CapSchell Inc (Chicago), every day, in the US alone, there are 5-10 ten arc flash incidents, some fatal.
    [Show full text]