ZENON SCADA DRIVER LİST zenon 7.0 Rev. 1
zenon 7
PLC and Bus drivers
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Codesys Soft PLC driver for the Codesys Soft Codesys SoftPLC PLC and Elau 3S ZT-3S32 A standard Codesys RT interface Ethernet, Local 3S-Gateway driver (Coedsys Gateway Server) Max 4 Replaced Codesys Soft PLC driver PLCs, Moeller for the Codesys 3S-ARTI interface. XControl PLCs The driver was replaced by the XC200 and Codesys Arti NG Treiber driver. Codesys Arti XC600, and Elau 3S ZT-3S32_ARTI A Ethernet, Local 3S-Arti SoftPLC driver PacDrive Controller MAX 4, C200, C400, C600, P600. Codesys Soft PLC driver "New PLCs, Moeller Generation" for the Codesys 3S- XControl PLCs ARTI (Asynchron Runtime XC200 and Interface) interface. The driver Codesys Arti NG XC600, and Elau 3S ZT-3S_ARTI_NG A supports direct variable import from Ethernet, Local 3S-Arti SoftPLC driver PacDrive the Codesys development Controller MAX 4, environment and replaces the C200, C400, Codesys Arti Soft PLC driver. C600, P600. Arcnet driver for ABB PLCs based ABB PLC of the series 07KTxx ARCNET - Driver on Arcnet Interface Card from So Coaxialcable ABB ZT-ARCNETNT A with Arcnet Arcnet for ABB Hard RG62/U connection
Driver for ABB serial driver for ABB 07KT94 PLCs ABB 07KT94 ABB ZT-CS3132 A Serial unknown 07KT94 The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850 protocol, using server/client IEC 61400-25-4
IEC 61400-25-4 ZT-IEC61400-25- services via TCP/IP (profile A1/T1). Annex C ABB R Ethernet IEC 61850 Annex C 4-C The driver acts as Client (Master) compatible Server during comunication. The driver supports Reporting (unbuffered and buffered).
The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850 protocol, using server/client services via TCP/IP (profile A1/T1). IEC 61850 ABB IEC 61850 driver ZT-IEC61850 R The driver acts as Client (Master) compatible PLCs Ethernet IEC 61850 during communication. The driver supports Reporting (unbuffered and buffered).
Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
Modbus TCP/IP. gateways - read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over ABB ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
The driver supports the protocol "Modbus RTU" over a serial All PLCs connection and over a TCP/IP supporting Modbus RTU - Modbus RTU, serial, Open Modbus RTU and connection and the protocol "Open Open Modbus Modbus TCP, ABB Open Modbus ZT-MODRTU32 A Modbus TCP" for TCP/IP Serial, Ethernet TCP/IP or Modbus RTU over TCP connection. The driver acts as a Modbus Master. (For a Modbus Modbus TCP, Modbus Slave please use the Process ASCII(seriell) ASCII - serial Gateway)
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE PDNet from the company Apex Schneider (www.apex.de), PDnet stands for Modicon PLCs: Process Data Transport Net and in TSX Compact the lower communication levels is A120, TSX
based on Arcnet. Compact Micro, TSX A250, A350, A500, TSX Bussystem, PDNet PCI - Quantum. ABB ABB ZT-PADNETPCI A Coaxialcable PDNet driver Protronic PLCs: RG62/U T200, CS31, AC31. Siemens PLCs: S5-115U, S5-135U, S5- 155U, S7-300, S7- 400
VME bus driver for LogidynD1 and LogidynD1 and AEG VMEBUS driver ZT-AGVME A LogidynD2 systems. Is developed LogidynD2 Unknown unknown by Alstom Berlin.
Supports all connections which are Allen Bradley PLC DataHighway available with RS Linx types: PLC2, Serial, Plus, DeviceNet, Allen Bradley RS- (http://www.software.rockwell.com) PLC3, PLC5, Allen-Bradley ZT-ALLENBNT A Bussystem, DataHighway, Linx driver PLC5250, Ethernet DF1, TCP/IP, SLC500; ControlNet
For all Allen Bradley PLCs All Allen Bradley Allen Bradley DF1- supporting DF1. The driver works PLCs with DF1 Allen-Bradley ZT-ALLENDF1 A Serial DF1 driver half duplex interface
Ethernet/IP driver for communication via Common Industrial Protocol - CIP from Open DeviceNet Vendor Organisation
(ODVA) with Allen-Bradley Logix Allen-Bradley PLCs. The driver supports direct ControlLogix, EtherNet/IP, Allen-Bradley browsing of variables from the PLC, CompactLogix Allen-Bradley ZT-LOGIX_ODVA C Ethernet Common ODVA driver offline browsing from projectfile and MicroLogix Industrial Protocol (*.L5K) and blockread/write for all PLCs datatypes including structures and arrays.
W ww.ab.com
VME bus driver for LogidynD1 and LogidynD1 and Alstom VMEBUS driver ZT-AGVME A LogidynD2 systems. Is developed LogidynD2 Unknown unknown by Alstom Berlin.
Driver for the IEC 60870-5-101 PLCs supporting
(serial) and the IEC 60870-5-104 the IEC 60870-5-
IEC 60870-5- (TCP/IP) protocol; a Master 101 or the IEC IEC 60870-5-104, Alstom ZT-IEC870 C Serial, Ethernet 101_104 driver (controlling station) 60870-5-104 IEC 60870-5-101 protocol.
PDNet from the company Apex Schneider (www.apex.de), PDnet stands for Modicon PLCs: Process Data Transport Net and in TSX Compact the lower communication levels is A120, TSX
based on Arcnet. Compact Micro, TSX A250, A350, A500, TSX Bussystem, PDNet PCI - Quantum. ABB Apex ZT-PADNETPCI A Coaxialcable PDNet driver Protronic PLCs: RG62/U T200, CS31, AC31. Siemens PLCs: S5-115U, S5-135U, S5- 155U, S7-300, S7- 400
Driver for all Applicom interface All PLCs, which
cards, which support MPI or support MPI resp. Applicom Applicom driver ZT-APPL B Bussystem MPI, Modbus Plus Modbus Plus. (http:\\www.applicom- Modbus Plus int.com)
Writes data cyclically to the harddisk in RAW format. (Only values, no timestamps, no status
Archive driver information). The data have to be - Archive ZT-ARCHDRV A Unknown unknown (RAW format) opened / further processed with external tools. (Tools only as examples available from COPA- DATA)
Arcnet driver for ABB PLCs based ABB PLC of the series 07KTxx ARCNET - Driver on Arcnet Interface Card from So Coaxialcable Arcnet ZT-ARCNETNT A with Arcnet Arcnet for ABB Hard RG62/U connection
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Driver for the IEC 60870-5-101 PLCs supporting
(serial) and the IEC 60870-5-104 the IEC 60870-5-
IEC 60870-5- (TCP/IP) protocol; a Master 101 or the IEC IEC 60870-5-104, Areva ZT-IEC870 C Serial, Ethernet 101_104 driver (controlling station) 60870-5-104 IEC 60870-5-101 protocol.
Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
Modbus TCP/IP. gateways - read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE
GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over Areva ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
The driver supports the protocol "Modbus RTU" over a serial All PLCs connection and over a TCP/IP supporting Modbus RTU - Modbus RTU, serial, Open Modbus RTU and connection and the protocol "Open Open Modbus Modbus TCP, Areva Open Modbus ZT-MODRTU32 A Modbus TCP" for TCP/IP Serial, Ethernet TCP/IP or Modbus RTU over TCP connection. The driver acts as a Modbus Master. (For a Modbus Modbus TCP, Modbus Slave please use the Process ASCII(seriell) ASCII - serial Gateway)
SaNORS (Standard asfinag SaNORS SaNORS - emergency call interface) - driver for compatible Asfinag Asfinag SOS- ZT-SANORS R the Asfinag SOS-telephones Asfinag SOS- Ethernet SaNORS telephones (www.asfinag.net) telephones
Direct TCP/IP driver for Bachmann MP 2xx/E, ME Bachmann M1 203/E, ME Bachmann ZT-BACH A M1 PLCs (www.bachmann.at) Ethernet unknown driver 203/EN
Replaced BACnet driver. The driver has been replaced by the BACnet All Bacnet NG driver. "BACnet/IP, Annex J" Bacnet and ASHRAE compliant BACnet driver BACnet ZT-BACNET C compliant PLCs; Ethernet BACnet/IP DDC4000 driver for "BACnet/IP, Annex J". The driver supports spontaneous data traffic. Kieback + Peter www.bacnet.org DDC4000 PLCs
This driver comunicates to one or more BACnet devices (BACnet-
Automation stations) using All PLCs with
BACnet driver BACnet/IP protocol. The connected BACnet/IP BACnet ZT-BACNETNG C Ethernet BACnet/IP Next Generation BACnet devices have to be support. operated as BACnet servers. The driver implements only client functionalities.
For serial hand-held scanner BCI hand-held Drv for BCI hand- BCI ZT-BCI A (http://www.bci-gmbh.de) scanner Serial unknown held scanner Replaced driver based on the Beckhoff ADS interface
Beckhoff TwinCat (www.beckhoff.com) The driver has TwinCat SoftPLC Beckhoff ZT-BECKH32 A Ethernet, Local ADS ADS driver been replaced by the Beckhoff NG driver. A conversion wizard is available. Driver for Beckhoff BC/BK9000. The
driver is based on the TC-ADS Beckhoff BC/BK Beckhoff BC-BK Beckhoff ZT-BECKH9000 A interface and uses a protocol 9000 bus clamps Ethernet TC-ADS 9000 optimized for the bus clamps.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Beckhoff TwinCAT driver "New generation" for TwinCAT Soft PLC
2.60 and higher. The driver is based TwinCat Soft PLC
on the TC-ADS interface. The driver 2.60 and higher- Beckhoff TwinCat Serial, Ethernet, Beckhoff ZT-BeckhNG A replaces the Beckhoff TC-ADS and also for TwinCat TC-ADS NG driver Local the Beckhhoff ADS driver. A v3 conversion wizard is available. The TC-ADS software has to be installed.
Replaced driver based on the Beckhoff TC-ADS interface. (www.beckhoff.com) The driver has
Beckhoff TwinCat been replaced by the Beckhoff NG TwinCat SoftPLC Serial, Ethernet, Beckhoff ZT-BECKHTC32 A TC-ADS TC-ADS driver driver. A conversion wizard is Local available. The TC-ADS software has to be installed.
Driver for the energy analysis Energyanalysis UPM 3000 Berg ZT-UPM32 A device UPM 3000 from Berg. Unknown unknown device UPM 3000 Driver for B+R Burklimat or B+R
System 2000 PLCs. Needs no PVI B+R System 2000
Bernecker + software but a special handling- and B+R BR TCP-IP driver ZT-BURTCP C Ethernet B+R TCP Rainer modul in the PLC witch can only Burklimat orderd from B+R . (www.br- automation.com)
The driver has been replaced by the All Bernecker and BR-PVI NG driver. Rainer PLCs The driver is based on PVI interface which can use the from Bernecker and Rainer. The PVI
variables can be online imported. communication
Communication parameters for all like System 2000 Bernecker + BR-PVI based family (2003, Serial, Ethernet, ZT-BUR20032 A variables are stored in a PVI Rainer driver (replaced) configuration file. The driver 2005 etc), CAN Bus Adapter supports spontaneous data Acopos, X20 exchange and hysteresis. (www.br- System, automation.com) AutomationPC, PowerPanel and others.
Driver for Bernercker and Rainer BuR RFID RFID Transponder Reader Transponder BR Transponder Reader Bernecker + 4102/4150 (BuR Modell number: Reader ZT-BuR41xx32 C 4102/4150 (BR USB unknown Rainer 5E9000.29) with USB interface. 4102/4150 modell number: 5E9000.29)
Up to date Bernecker and Rainer All Bernecker and driver based on PVI interface from Rainer PLCs Bernecker and Rainer. The which can use the variables can either be imported PVI
online from the PLC or offline form communication
the B&R OPC interface. like System 2000 Bernecker + BR-PVI based family (2003, ZT-BURPVI A Communication parameters are Serial, Ethernet PVI Rainer driver stored at each variable. The driver 2005 etc), supports spontaneous data Acopos, X20 exchange and hysteresis. (www.br- System, automation.com) AutomationPC, PowerPanel and others.
Mininet Master driver for B+R PLCs B+R Minicontrol Bernecker + Mininet-Master (www.br-automation.com) and B+R System ZT-MINI32 A Serial Mininet Rainer driver 2000
Driver for comunication with a Biffi DCM Master Biffi-Tyco Flow Station Biffi DCM SCADA Biffi DCM ZT-BIFFIDCM B redundant Biffi DCM Master station. Ethernet Control (www.biffi.it) (redundant) (TCP/IP)
The driver waits on a TCP/IP port, Any Modbus
until the Brodersen Gateway PLCs that can be
establishes a GPRS connection. connected via the Passive Modbus Modbus RTU over Brodersen ZT-MODLISTEN R Then it communicates via Modbus Brodersen UCM- Ethernet RTU driver TCP RTU. (www.brodersencontrols.com) 97 GPRS- Gateway.
Driver for straton connection. straton Brodersen straton driver ZT-STRATON - Ethernet, Local TCP/IP Driver for communication with straton PLCs. Replaces straton 32 driver. The driver can use several PLCs based on Brodersen straton NG driver ZT-StratonNG A connections at the same time and the straton VMTK. Ethernet TCP/IP uses an improved communication concept.
Driver for Brodersen RTUs System 2000 Brodersen RTUs Brodersen ZT-SYS2000 A (www.brodersencontrols.com) Serial, Bitbus unknown driver
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Driver for Brodersen RTUs with logging mechanisms. Supports the System 2000 Brodersen RTUs Brodersen ZT-SYSLOG B functionality of reading historical Serial, Bitbus unknown driver with logging (logged) data. (www.brodersencontrols.com)
The driver communicates via the module KM471with connected Modul KM471 Buderus Buderus32 driver ZT-BUDERUS A ECOCAN-BUS modules. Serial 3964R/RK512 (http://www.heiztechnik.buderus.de)
Driver for straton connection. straton Copalp straton driver ZT-STRATON - Ethernet, Local TCP/IP Driver for communication with straton PLCs. Replaces straton 32 driver. The driver can use several PLCs based on Copalp straton NG driver ZT-StratonNG A connections at the same time and the straton VMTK. Ethernet TCP/IP uses an improved communication concept.
Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
Modbus TCP/IP. gateways - read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE
GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over Costronic ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
Driver for CTI PLCs,, Texas
Instruments TI 505 PLCs or Simatic CTI PLCs, Ti505, 545/555 PLCs. The driver support Simatic 545, CTI CTI driver ZT-CTI B Ethernet NITP, CAMP the protocols CAMP and NITP with Simatic 555 Packed Task Codes.
Driver for Texas Instruments TI 505 TI 505 - 545 / 545. Protocols: TBP,NITP, TCP/IP TI 505 and 545 TCP/IP, TBP, CTI ZT-TI500 A Serial, Ethernet driver NITP
Driver for the Danfoss control Danfoss AKC devices via AKC OLE interface. Danfoss Danfoss driver ZT-DAN A control device Serial 3964R/RK512 (www.danfoss.com)
Connection to the DataTaker data recording and logging systems All DataTaker DataTaker DataTaker driver ZT-DATATAKE A (www.datataker.com) models Serial unknown
Data exchange with external programs on file basis. Values are
read from a file and displayed resp. - Dateien File driver ZT-DATEI32 A archived in zenon. Values can also Local unknown be written into a file by zenon.
Driver for the data exchange with All Applications Dateien DDE Client driver - - applications supporting DDE. Also supporting DDE. Ethernet, Local DDE supports NET DDE.
Writes data cyclically to the harddisk in RAW format. (Only values, no timestamps, no status
Archive driver information). The data have to be - Datenbanken ZT-ARCHDRV A Unknown unknown (RAW format) opened / further processed with external tools. (Tools only as examples available from COPA- DATA)
Data exchange with external programs on file basis. Values are
read from a file and displayed resp. - Datenbanken File driver ZT-DATEI32 A archived in zenon. Values can also Local unknown be written into a file by zenon.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Driver for the data exchange with All Applications applications supporting DDE. Also Datenbanken DDE Client driver - - supporting DDE. Ethernet, Local DDE supports NET DDE.
The driver is used for the SQL database Datenbanken SQL Driver ZT-SQLDRV A bidirectional data exchange with a supporting ODBC Ethernet, Local SQL SQL database supporting ODBC.
Driver for the data exchange with All Applications DDE DDE Client driver - - applications supporting DDE. Also supporting DDE. Ethernet, Local DDE supports NET DDE.
For DMX512 Dimmerbus protocol - Dimmerbus DMX 512 driver ZT-DIMM A from U.S. Institute of Theatre Bussystem Dimmerbus Technology (USITT)
Connection to DNP3 compatible All DNP3 DNP3, GE DNP3 DNP3 driver ZT-DNP3 C PLCs compatible PLCs Serial, Ethernet Harris(DNP3)
Driver for the communication with
LON nodes via iLon100 router from LON nodes Echelon i-LON 100 driver ZT-LON100 C Echelon. (www.echelon.com) Ethernet Lon Bus
Driver for the communication with LON nodes Ethernet, PC Slot Echelon LON driver ZT-LON32 C LON nodes. Lon Bus Card Driver for the communication with
the European Installation Bus (EIB / EIB/KNX capable European EIB ZT-EIBV2_32 C KNX). In the Runtime the driver stations Serial, Ethernet EIB Bus Installation Bus needs the Falcon Runtime.
Codesys Soft PLC driver for the Codesys Soft Codesys SoftPLC PLC and Elau Elau ZT-3S32 A standard Codesys RT interface Ethernet, Local 3S-Gateway driver (Coedsys Gateway Server) Max 4
Replaced Codesys Soft PLC driver Codesys Soft for the Codesys 3S-ARTI interface. PLCs, Moeller The driver was replaced by the XControl PLCs Codesys Arti NG Treiber driver. XC200 and Codesys Arti XC600, and Elau Elau ZT-3S32_ARTI A Ethernet, Local 3S-Arti SoftPLC driver PacDrive Controller MAX 4, C200, C400, C600, P600.
Codesys Soft PLC driver "New Codesys Soft Generation" for the Codesys 3S- PLCs, Moeller ARTI (Asynchron Runtime XControl PLCs Interface) interface. The driver XC200 and Codesys Arti NG XC600, and Elau Elau ZT-3S_ARTI_NG A supports direct variable import from Ethernet, Local 3S-Arti SoftPLC driver the Codesys development PacDrive environment and replaces the Controller MAX 4, Codesys Arti Soft PLC driver. C200, C400, C600, P600.
For point-to-point communication or Eldatic, OC, POC resp. ELFE Elin Eldatic driver ZT-ELIN A automatic calling modem Serial unknown connection. systems
The ELREST32 Network driver is CAN_M167, used for the data connection to an CAN_M515, Elrest CAN CAN_M960, Elrest ZT-ELREST32 A Elrest net system via a CAN/MPC or PC Slot Card unknown Network driver RS232 interface. CAN_C515, GRAPHDEV.
Driver for ESA W indows CE Siemens S7-
terminal including ESA PCI CIB PLCs or
communication card for W indows compatible PLCs Driver for ESA ESA ZT-ESA32 A CE for the communication with (e.g. Vipa) with Local MPI PCI CIB PLCs supporting MPI. S7 functions via MPI.
Driver for fire alarm system Esser BMZ 8000. The driver only supports Driver for Esser Esser BMZ 8000 Protokoll1, Esser ZT-ESSER32 B reading access. (http://www.igs- Serial BMZ 8000 hagen.de/brandzentralen.htm) Protokoll2
Driver for Euchner chip card ident Euchner Ident System Identsystem Euchner ZT-EUCH C system (www.euchner.de) Serial unknown driver CIS3(A)
EasyIP driver for Festo IPC/FEC, FPC 101, Festo Festo EasyIP FST- Festo ZT-FEASYIP A Multiprog programming. EasyIP Ethernet Multiprog driver (www.festo.com) Programmierung
Serial/CI driver for Festo Supports series FPC/IPC/FEC, FST programming. FEC, IPC and Festo Serial-CI FPCxxx, no FST- Festo ZT-FEFRC A Uses testing system of the FST Serial driver, FST kernel. (www.festo.com) addintional Programmierung components
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE The driver supports the protocol "Modbus RTU" over a serial All PLCs connection and over a TCP/IP supporting Modbus RTU - Modbus RTU, serial, Open Modbus RTU and connection and the protocol "Open Open Modbus Modbus TCP, Gantner Open Modbus ZT-MODRTU32 A Modbus TCP" for TCP/IP Serial, Ethernet TCP/IP or Modbus RTU over TCP connection. The driver acts as a Modbus Master. (For a Modbus Modbus TCP, Modbus Slave please use the Process ASCII(seriell) ASCII - serial Gateway)
Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
gateways Modbus TCP/IP.
- read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over GE Fanuc ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
The driver supports the protocol "Modbus RTU" over a serial All PLCs connection and over a TCP/IP supporting Modbus RTU - Modbus RTU, serial, Open Modbus RTU and connection and the protocol "Open Open Modbus Modbus TCP, GE Fanuc Open Modbus ZT-MODRTU32 A Modbus TCP" for TCP/IP Serial, Ethernet TCP/IP or Modbus RTU over TCP connection. The driver acts as a Modbus Master. (For a Modbus Modbus TCP, Modbus Slave please use the Process ASCII(seriell) ASCII - serial Gateway)
Connection to DNP3 compatible All DNP3 DNP3, GE GE Harris DNP3 driver ZT-DNP3 C PLCs compatible PLCs Serial, Ethernet Harris(DNP3)
The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850
protocol, using server/client IEC 61400-25-4
IEC 61400-25-4 ZT-IEC61400-25- services via TCP/IP (profile A1/T1). Annex C GE Multilin R Ethernet IEC 61850 Annex C 4-C The driver acts as Client (Master) compatible Server during comunication. The driver supports Reporting (unbuffered and buffered).
The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850 protocol, using server/client services via TCP/IP (profile A1/T1). IEC 61850 GE Multilin IEC 61850 driver ZT-IEC61850 R The driver acts as Client (Master) compatible PLCs Ethernet IEC 61850 during communication. The driver supports Reporting (unbuffered and buffered).
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
Modbus TCP/IP. gateways - read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE
GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over GE Multilin ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
The driver supports the protocol "Modbus RTU" over a serial All PLCs connection and over a TCP/IP supporting Modbus RTU - Modbus RTU, serial, Open Modbus RTU and connection and the protocol "Open Open Modbus Modbus TCP, GE Multilin Open Modbus ZT-MODRTU32 A Modbus TCP" for TCP/IP Serial, Ethernet TCP/IP or Modbus RTU over TCP connection. The driver acts as a Modbus Master. (For a Modbus Modbus TCP, Modbus Slave please use the Process ASCII(seriell) ASCII - serial Gateway)
Driver for fire alarm systems from Hekatron BMZ 340 fire alarm Hekatron Hekatron driver ZT-HEKA32 A Hekatron (www.hekatron.de). Serial unknown system
Driver for 3964R/RK512 All PLCs supporting 3963R/RK512;
e.g. Siemens
S5/S7 with according CP or CPU; Schleicher 3964R-RK512 Helmholz ZT-3964R32 A P03 via RK512. Serial 3964R/RK512 driver With Helmholz Adapter communication with all PLCs with MPI support possible.
Driver for Hilscher Netlink Adapter Siemens S7-
(MPI -> TCP/IP) or Hilscher CIF-PB PLCs or
cards. The Netlink Adapter is also compatible PLCs
Hilscher MPI available identical in construction (e.g. VIPA) with Ethernet, PC Slot Helmholz ZT-OPENMPI A MPI driver from IBH and Helmholz. MPI interface. Card (http://www.hilscher.com) The PLC must be MPI Master.
Driver for the MPI->HMI adapter Siemens S7-
from Siemens or Helmholz PLCs or
compatible PLCs HMI adapter Helmholz ZT-S7HMI A (e.g. VIPA) with Serial MPI driver S7 functions via MPI.
For the serial communication via the Siemens PC adapter / Helmholz PC
adapter to Siemens and Vipa PLCs Siemens S7
PC Adapter - Vipa ZT- with MPI interface. Alternativ: Serial 300/400 CPUs, all Siemens PC- Helmholz A Serial Green Cable S7PCADAPTER communication to Vipa PLCs via the VIPA CPUs Protocol Vipa Green Cable to the Vipa PD interface.
Generic CIF driver for Interbus and Profibus DP cards from Hilscher
(www.hilscher.com). The driver can All Profibus DP
Hilscher CIF be configured as master or as slave resp. Interbus bus Profibus DP, Hilscher ZT-CIF32 A Bussystem driver and communicates with the bus participants. Interbus participants on the data level without protocol.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Driver for Hilscher Netlink Adapter Siemens S7-
(MPI -> TCP/IP) or Hilscher CIF-PB PLCs or
cards. The Netlink Adapter is also compatible PLCs
Hilscher MPI available identical in construction (e.g. VIPA) with Ethernet, PC Slot Hilscher ZT-OPENMPI A MPI driver from IBH and Helmholz. MPI interface. Card (http://www.hilscher.com) The PLC must be MPI Master.
COMM-H driver (www.hitachi.com) All H-series processors are Hitachi Hitachi driver ZT-HITA A Serial COM-H supported.
The Hydrometer driver connects to IZAR Center (made by Hydrometer GmbH). The IZAR Center connects either M-Bus devices or Hydrometer Hydrometer-IZAR Hydrometer Hydrometer Driver ZT-Hydrometer B radio receivers. The radio receivers Center Serial, Ethernet M-Bus (M-Bus Receiver 868) are reading remote devices in ist range. (www.hydrometer.de)
Driver for Hilscher Netlink Adapter Siemens S7-
(MPI -> TCP/IP) or Hilscher CIF-PB PLCs or
cards. The Netlink Adapter is also compatible PLCs
Hilscher MPI available identical in construction (e.g. VIPA) with Ethernet, PC Slot IBH ZT-OPENMPI A MPI driver from IBH and Helmholz. MPI interface. Card (http://www.hilscher.com) The PLC must be MPI Master.
The driver supports the Siemens S5 IBH Soft PLC S5 Driver for IBH Soft IBH ZT-IBHRTSPS A and S7 compatible Soft PLC from and S7 Local unknown PLC IBH (www.IBHsoftec.de)
Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
Modbus TCP/IP. gateways - read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over ICE ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
Driver for Idec MicroSmart,OpneNet Idec MicroSmart,
Controller and FC4A-HPC1. Idec OpenNet Idec Idec Idec driver ZT-IDEC A (www.idec.com) Controller, Idec Serial Communication FC4A -HPC1 Protocol
The driver uses a communication protocol (SSCP) developed by COPA-DATA. The protocol is used for a spontaneous communication
via TCP/IP to IEC 61499 controls. The protocol specification disclosed IEC 61499 IEC IEC 61499 driver ZT-IEC61499 C in the driver documentation and can compatible PLCs Ethernet SSCP be implemented easily for each control.
Driver for read out of values from energy meters. The driver uses IEC 62056-21 or IEC 61107 IEC-62056-21 protocol A of IEC 62056-21 IEC 62056-21, IEC ZT-IEC62056 B compatible enrgy Serial, Ethernet Driver specification. The driver supports IEC 61107 read only comunication. meter
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850
protocol, using server/client IEC 61400-25-4
IEC 61400-25-4 ZT-IEC61400-25- services via TCP/IP (profile A1/T1). Annex C IEC R Ethernet IEC 61850 Annex C 4-C The driver acts as Client (Master) compatible Server during comunication. The driver supports Reporting (unbuffered and buffered).
The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850 protocol, using server/client services via TCP/IP (profile A1/T1). IEC 61850 IEC IEC 61850 driver ZT-IEC61850 R The driver acts as Client (Master) compatible PLCs Ethernet IEC 61850 during communication. The driver supports Reporting (unbuffered and buffered).
Driver for the IEC 60870-5-101 PLCs supporting
(serial) and the IEC 60870-5-104 the IEC 60870-5-
IEC 60870-5- (TCP/IP) protocol; a Master 101 or the IEC IEC 60870-5-104, IEC ZT-IEC870 C Serial, Ethernet 101_104 driver (controlling station) 60870-5-104 IEC 60870-5-101 protocol.
IEC60870-5-103 Treiber für IEC60870 -5- 103 Serial, IEC 60870 - 5 - communication compatible IEC ZT-IEC870-103 B Bussystem, IEC 60870-5-103 103 Driver controls Ethernet H1 protocol driver for Siemens S5. H1 resp. "Industrial Ethernet" is the protocol name for the cellular network, which is based on the 7- Siemens S5 Inat S5 H1 driver ZT-S5H1NT B layer-model of the ISO/OSI Ethernet H1 standard. (www.vipa.de, www.siemens.de, www.inat.de). At PC you need the PC H1 Driver from INAT. Driver for the S5 TCP/IP
communication. The driver Siemens S5,
supports polling (SEND/RECEIVE) Siemens S7 (only
and spontaneous communication with VIPA Inat S5 TCP-IP driver ZT-S5TCP32 B Ethernet TCP/IP (FETCH/WRITE). (www.vipa.de, CP443), Vipa www.siemens.de, www.inat.de, System 300 www.process-informatik.de)
Driver for S7 PLCs via MPI / H1 / Profibus DP / TCP/IP. Based on the Siemens S7 Profibus DP, MPI, S7 driver Softnet 300/400 and other Ethernet, PC Slot TCP/IP - Inat ZT-S7NT B software SIMATIC NET (Softnet) based from Siemens. (www.siemens.com) compatible PLCs Card RFC1006, ISO 8073
Driver for S7 TCP/IP connection via Siemens S7 200, standard network card without 300, 400 and 1200 or VIPA TCP/IP - Inat S7 TCP-IP driver ZT-S7TCP C additional software. The driver Ethernet supports Simatic PDiag. 200V, 300V, 300S RFC1006 (www.siemens.com) and 500S
Generic CIF driver for Interbus and Profibus DP cards from Hilscher
(www.hilscher.com). The driver can All Profibus DP
Hilscher CIF be configured as master or as slave resp. Interbus bus Profibus DP, Interbus ZT-CIF32 A Bussystem driver and communicates with the bus participants. Interbus participants on the data level without protocol.
Driver for the Keba / Hilscher PLCs with Universal Bus Gatway CP001. according CP001 Gateway interface and Profibus DP, Interbus ZT-CP001 A Supports communication via Serial driver Profibus, Interbus usw. Expander Interbus program
Driver for Interbus S Generation 4, Interbus S
Based on Interbus PC cards from Generation 4 (I/O Interbus Interbus S driver ZT-INTERNT A Bussystem Interbus Phönic Contact communication) (www.phoenixcontact.com).
Driver for internal variables. Variables can be local resp. global
Driver for internal and can be started with an initial - Internal driver - - Local unknown variables value or with the last value (remanence). The driver does not use up I/Os or TAGs.
zenon Mathematics driver. For Driver for numerical and binary operations. - Internal driver Mathematics - - The driver does not use up I/Os or Local unknown variable TAGs.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE zenon Simulation driver for
Driver for simulation and internal variables. - Internal driver simulator - - Variables also can be saved Local unknown variables remant. The driver does not use up I/Os or TAGs.
zenon System driver for displaying internal project information, network information, hardware information of Driver for system - Internal driver - - the PC etc. The driver does not use Local unknown variables up I/Os or TAGs.
Driver for Data Acquisition Boards DaqBoard/2000 Driver for Iotech ZT-DAQ B series 2000 (www.iotech.com) series PC Slot Card unknown DaqBoard-2000
Driver for comminication to Jetter PLCs via serial Interface, JETW ay, All Jetter PLCs Jetter Jetter Treiber ZT-JETTER B PCPPLC, and via Ethernet Serial, Ethernet Jetter UDP/TCP (JetIP/JetSTX) www.jetter.de
The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850
protocol, using server/client IEC 61400-25-4
IEC 61400-25-4 ZT-IEC61400-25- services via TCP/IP (profile A1/T1). Annex C Kalki R Ethernet IEC 61850 Annex C 4-C The driver acts as Client (Master) compatible Server during comunication. The driver supports Reporting (unbuffered and buffered).
The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850 protocol, using server/client services via TCP/IP (profile A1/T1). IEC 61850 Kalki IEC 61850 driver ZT-IEC61850 R The driver acts as Client (Master) compatible PLCs Ethernet IEC 61850 during communication. The driver supports Reporting (unbuffered and buffered).
Driver for the Keba / Hilscher PLCs with Universal Bus Gatway CP001. according CP001 Gateway interface and Profibus DP, Keba ZT-CP001 A Supports communication via Serial driver Profibus, Interbus usw. Expander Interbus program
Driver for comunication with the Kemro User ID USB Interface. The driver can read out datat from Keba Kemro User ID Kemro User ID Keba ZT-KEMROUID R RFID Chips. The driver is only USB unknown Driver available from Keba directly in combination with the hardware. (www.keba.com)
Driver for the buttons on the Ketop T100 and Driver for the Keba ZT-KETOP A Ketop T100 and T50 T50 Local unknown buttons /Ketop Replaced BACnet driver. The driver has been replaced by the BACnet All Bacnet NG driver. "BACnet/IP, Annex J" Bacnet and ASHRAE compliant BACnet driver Kieback + Peter ZT-BACNET C compliant PLCs; Ethernet BACnet/IP DDC4000 driver for "BACnet/IP, Annex J". The driver supports spontaneous data traffic. Kieback + Peter www.bacnet.org DDC4000 PLCs
This driver comunicates to one or more BACnet devices (BACnet-
Automation stations) using All PLCs with
BACnet driver BACnet/IP protocol. The connected BACnet/IP Kieback + Peter ZT-BACNETNG C Ethernet BACnet/IP Next Generation BACnet devices have to be support. operated as BACnet servers. The driver implements only client functionalities.
Driver for modules from the DDC centres; Kieback + Peter company Kieback+Peter Kieback + Peter ZT-KUP A DDC3xxx Serial P90 driver (www.kieback-peter.de)
Driver for the SoftPLC openPLC Kirchner openPLC Kirchnersoft LogiCAD driver ZT-LC32 A from Kirchner. Local unknown (www.kirchnersoft.com) SoftPLC.
Driver for the communication with
the European Installation Bus (EIB / EIB/KNX capable European KNX ZT-EIBV2_32 C KNX). In the Runtime the driver stations Serial, Ethernet EIB Bus Installation Bus needs the Falcon Runtime.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Driver for the Koyo Sequence Koyo Sequence models (www.koyoele.co.jp/english) model series: KOYO Sequence Koyo ZT-KOYO B LOGIC, GE and Serial, Ethernet unknown driver Kostac S
Direct driver for all ProConOS All Control based Controll systems from Systems from Phoenix Contact. Phoenix Contact
W ww.phoenixcontact.com based on
ProConOS, e.g. Inline Controller Phoenix Contact (ILC),Remote KW-Software ZT-PHOENIX32 B Ethernet ProConOS driver Field Controller (RFC) , PC- Interface Cards (FC) etc. except: the serie 100 is not supported.
Driver for comunication with devices in packaging and process industry VDMAXML_P using VDMAXML_P Protocoll e.g.: compatible PLCs Laetus components. or devices; Laetus VDMA-XML driver ZT-VDMA_XML B Www.vdma.org, www.laetus.com Laetus devices Ethernet VDMAXML_P with VDMA-XML interface server.
Driver for PCS807 communication
box from Lauer for communication S5 or S7 PLC via PCS807 Profibus Lauer ZT-PCS80732 A via ProfibusDP. (www.systeme- Profibus-DP Serial Profibus DP DP driver lauer.de)
Driver for PCS812 communication Siemens S7-
box from Lauer for communication PLCs or
PCS812 S7 via MPI. (www.systeme-lauer.de) compatible PLCs Lauer ZT-PCS812 A Serial MPI connection (e.g. VIPA) with MPI interface
Driver for the MPI-ISA card from Siemens S7300 Lauer for communication with a S7 /400 and Lauer S7_MPIISA driver ZT-S7MPIISA A PLC. (www.lauer-systeme.de) compatible with PC Slot Card MPI MPI interface.
Driver for the communication with
LON nodes via iLon100 router from LON nodes LON i-LON 100 driver ZT-LON100 C Echelon. (www.echelon.com) Ethernet Lon Bus
Driver for the communication with LON nodes Ethernet, PC Slot LON LON driver ZT-LON32 C Lon Bus LON nodes. Card For XGT series PLC from LS Industrial Systems. For Input and
LS Industrial Output, symbolic und direct XGT Series XGT dedicated LSIS ZT-LS_XGT B Ethernet Systems-XGT variables. Suppeort numerical data protocol types from 1 Bit up to 8 Byte (eng.lsis.biz).
Driver for Panasonic (former Matsushita) FPx PLCs Pansasonic (www.panasonic-electric- (Matsushita) Panasonic serial PLCs of the types Matsushita ZT-MATSU32 A works.com). The driver also Serial unknown driver supports modem connection. FP0/FP1/FP3/FP 10SH/FP-M/FP2
TCP/IP driver for Matsushita FPx PLCs via standard network card. Matsushita PLCs of the types Matsushita TCP- (www.matsushita.de) Matsushita ZT-MATSUTCP A FP0/FP1/FP3/FP Ethernet TCP/IP IP driver 10SH/FP-M/FP2
Driver for the standard M-Bus Standard M-Bus M-Bus slaves M-Bus ZT-MBUS32 B protocol. Serial M-Bus driver Driver for Mitsubishi A and Q series. Supports CPUs of Mitsubishi - (http://www.meau.com) the AnS/AnA and Melsec A, Melsec Mitsubishi ZT-MITSUB A Serial, Ethernet Melsec A-Q driver Q series. Q
Driver for Mitsubishi FX series. Mitsubishi FX- Mitsubishi - Mitsubishi ZT-MITFX A (http://www.meau.com) 32MR Serial, Ethernet Melsec FX Melsec FX driver
Driver for all Applicom interface All PLCs, which
cards, which support MPI or support MPI resp. Modbus Plus Applicom driver ZT-APPL B Bussystem MPI, Modbus Plus Modbus Plus. (http:\\www.applicom- Modbus Plus int.com)
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
Modbus TCP/IP. gateways - read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE
GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over Modbus RTU ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
The driver supports the protocol "Modbus RTU" over a serial All PLCs connection and over a TCP/IP supporting Modbus RTU - Modbus RTU, serial, Open Modbus RTU and connection and the protocol "Open Open Modbus Modbus TCP, Modbus RTU Open Modbus ZT-MODRTU32 A Modbus TCP" for TCP/IP Serial, Ethernet TCP/IP or Modbus RTU over TCP connection. The driver acts as a Modbus Master. (For a Modbus Modbus TCP, Modbus Slave please use the Process ASCII(seriell) ASCII - serial Gateway)
The driver waits on a TCP/IP port, Any Modbus
until the Brodersen Gateway PLCs that can be
establishes a GPRS connection. connected via the Passive Modbus Modbus RTU over Modbus RTU ZT-MODLISTEN R Then it communicates via Modbus Brodersen UCM- Ethernet RTU driver TCP RTU. (www.brodersencontrols.com) 97 GPRS- Gateway.
Connection to Modicon TSX PLC Modicon TSX Modicon TSX Modicon ZT-MODICON A via Unitelway protocol. Serial Unitelway Micro driver (www.schneider-electric.de)
PDNet from the company Apex Schneider (www.apex.de), PDnet stands for Modicon PLCs: Process Data Transport Net and in TSX Compact the lower communication levels is A120, TSX
based on Arcnet. Compact Micro, TSX A250, A350, A500, TSX Bussystem, PDNet PCI - Quantum. ABB Modicon ZT-PADNETPCI A Coaxialcable PDNet driver Protronic PLCs: RG62/U T200, CS31, AC31. Siemens PLCs: S5-115U, S5-135U, S5- 155U, S7-300, S7- 400
Codesys Soft PLC driver for the Codesys Soft Codesys SoftPLC PLC and Elau Moeller ZT-3S32 A standard Codesys RT interface Ethernet, Local 3S-Gateway driver (Coedsys Gateway Server) Max 4
Replaced Codesys Soft PLC driver Codesys Soft for the Codesys 3S-ARTI interface. PLCs, Moeller The driver was replaced by the XControl PLCs Codesys Arti NG Treiber driver. XC200 and Codesys Arti XC600, and Elau Moeller ZT-3S32_ARTI A Ethernet, Local 3S-Arti SoftPLC driver PacDrive Controller MAX 4, C200, C400, C600, P600.
Codesys Soft PLC driver "New Codesys Soft Generation" for the Codesys 3S- PLCs, Moeller ARTI (Asynchron Runtime XControl PLCs Interface) interface. The driver XC200 and Codesys Arti NG XC600, and Elau Moeller ZT-3S_ARTI_NG A supports direct variable import from Ethernet, Local 3S-Arti SoftPLC driver the Codesys development PacDrive environment and replaces the Controller MAX 4, Codesys Arti Soft PLC driver. C200, C400, C600, P600.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Developed for special Moeller Profibus DP Profibus DP participant. Also can Slaves (Only participants, Profibus DP communicate with other passive Moeller ZT-DPUNI32 C which need no PC Slot Card Profibus DP Master driver Profibus DP participants. Better alternative: straton with Profibus DP own driver. configuration)
Driver for Klöckner+Moeller PLCs. PS306, PS316,
(www.moeller.net) PS416, PS4-100,
PS4-200,
Moeller Electric PS3/PS4-100 via Moeller ZT-PSUNI32 A Serial Sucom A PSUNI driver ZB4-501-UM1 to PS4-200 via ZB4- 303-KB1
Mininet Master driver for B+R PLCs B+R Minicontrol Mininet-Master and B+R System Mondial ZT-MINI32 A (www.br-automation.com) Serial Mininet driver 2000
Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
Modbus TCP/IP. gateways - read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over Mondial ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
The driver supports the protocol "Modbus RTU" over a serial All PLCs connection and over a TCP/IP supporting Modbus RTU - Modbus RTU, serial, Open Modbus RTU and connection and the protocol "Open Open Modbus Modbus TCP, Mondial Open Modbus ZT-MODRTU32 A Modbus TCP" for TCP/IP Serial, Ethernet TCP/IP or Modbus RTU over TCP connection. The driver acts as a Modbus Master. (For a Modbus Modbus TCP, Modbus Slave please use the Process ASCII(seriell) ASCII - serial Gateway)
Driver for 3964R/RK512 All PLCs supporting 3963R/RK512;
e.g. Siemens
S5/S7 with according CP or CPU; Schleicher 3964R-RK512 MPI ZT-3964R32 A P03 via RK512. Serial 3964R/RK512 driver With Helmholz Adapter communication with all PLCs with MPI support possible.
Driver for all Applicom interface All PLCs, which
cards, which support MPI or support MPI resp. MPI Applicom driver ZT-APPL B Bussystem MPI, Modbus Plus Modbus Plus. (http:\\www.applicom- Modbus Plus int.com)
Driver for MPI Siemens CE platform Siemens S7300
S7 MPI for (http://www.open-platform- /400 and MPI Siemens CE ZT-MPI A program.com/products/default.asp) compatible with Bussystem MPI terminals MPI interface.
Driver for Hilscher Netlink Adapter Siemens S7-
(MPI -> TCP/IP) or Hilscher CIF-PB PLCs or
cards. The Netlink Adapter is also compatible PLCs
Hilscher MPI available identical in construction (e.g. VIPA) with Ethernet, PC Slot MPI ZT-OPENMPI A MPI driver from IBH and Helmholz. MPI interface. Card (http://www.hilscher.com) The PLC must be MPI Master.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Driver for ESA W indows CE Siemens S7-
terminal including ESA PCI CIB PLCs or
communication card for W indows compatible PLCs Driver for ESA MPI ZT-ESA32 A CE for the communication with (e.g. Vipa) with Local MPI PCI CIB PLCs supporting MPI. S7 functions via MPI.
Driver for the MPI->HMI adapter Siemens S7-
from Siemens or Helmholz PLCs or
compatible PLCs HMI adapter MPI ZT-S7HMI A (e.g. VIPA) with Serial MPI driver S7 functions via MPI.
Driver for PCS812 communication Siemens S7-
box from Lauer for communication PLCs or
PCS812 S7 via MPI. (www.systeme-lauer.de) compatible PLCs MPI ZT-PCS812 A Serial MPI connection (e.g. VIPA) with MPI interface
Driver for the MPI-ISA card from Siemens S7300 Lauer for communication with a S7 /400 and MPI S7_MPIISA driver ZT-S7MPIISA A PLC. (www.lauer-systeme.de) compatible with PC Slot Card MPI MPI interface.
Driver for S7 PLCs via MPI / H1 / Profibus DP / TCP/IP. Based on the Siemens S7 Profibus DP, MPI, S7 driver Softnet 300/400 and other Ethernet, PC Slot TCP/IP - MPI ZT-S7NT B software SIMATIC NET (Softnet) based from Siemens. (www.siemens.com) compatible PLCs Card RFC1006, ISO 8073
For the serial communication via the Siemens PC adapter / Helmholz PC
adapter to Siemens and Vipa PLCs Siemens S7
PC Adapter - Vipa ZT- with MPI interface. Alternativ: Serial 300/400 CPUs, all Siemens PC- MPI A Serial Green Cable S7PCADAPTER communication to Vipa PLCs via the VIPA CPUs Protocol Vipa Green Cable to the Vipa PD interface.
Driver for the communication via a Siemens S7 and MPI net throuh a SST Interface other PLCs MPI SST Driver ZT-SST A PC Slot Card MPI Card. (www.mysst.com) supporting MPI
Driver for communication with VIPA Siemens S7-
Windows CE Touch Panel with PLCs or
integrated S7-Chip for PLC compatible PLCs Driver for VIPA MPI ZT-VIPA32 A connected trough MPI. (eg. Vipa) with " Bussystem, Local MPI CE touchpanel S7 functions" over MPI.
Driver for Omron SYSMAC. FINS = Factory Information Network OMRON Omron FINS Omron ZT-OMRONFINS A SYSMAC Serial, Ethernet Omron FINS driver System (www.europe.omron.com)
Driver for Omron PLCs C200H Series (www.europe.omron.com) (C200HX, C200HG, Omron OMRON driver ZT-OMRON32 A Serial Omron Host Link C200HE), C500, C1000, C2000
Driver for the communication with The OPC Server OPC Servers. must have implemented the interface in the OPC Client V2-0 OPC ZT-OPCCLI32 A version 1.0A or Local OPC driver 2.0x Browsing is supported.
Driver for comunication with all OPC All OPC-UA
UA (Unified Architecture) servers. server with Data OPC UA Client OPC ZT-OPCUA B The driver supports only Data Access Ethernet, Local OPC-UA driver Access (DA). comunication www.opcfoundation.org
Driver for OSAI Soft PLC/CNC OSAI Soft OSAI TCP/IP based on W indows CE. OSAI ZT-OSAI A PLC/CNC Ethernet Osai W inNBI driver (www.osai.it)
Driver for the connection to an Otis
Driver for Otis controller (Lift control). The driver - Otis ZT-OTIS B Serial Otis Protokoll controller only supports reading access. (www.otis.com)
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Driver for Panasonic (former Matsushita) FPx PLCs Pansasonic (www.panasonic-electric- (Matsushita) Panasonic serial PLCs of the types Panasonic ZT-MATSU32 A works.com). The driver also Serial unknown driver supports modem connection. FP0/FP1/FP3/FP 10SH/FP-M/FP2
TCP/IP driver for Matsushita FPx PLCs via standard network card. Matsushita PLCs of the types Matsushita TCP- (www.matsushita.de) Panasonic ZT-MATSUTCP A FP0/FP1/FP3/FP Ethernet TCP/IP IP driver 10SH/FP-M/FP2
PDNet from the company Apex Schneider (www.apex.de), PDnet stands for Modicon PLCs: Process Data Transport Net and in TSX Compact the lower communication levels is A120, TSX
based on Arcnet. Compact Micro, TSX A250, A350, A500, TSX Bussystem, PDNet PCI - Quantum. ABB PDNet ZT-PADNETPCI A Coaxialcable PDNet driver Protronic PLCs: RG62/U T200, CS31, AC31. Siemens PLCs: S5-115U, S5-135U, S5- 155U, S7-300, S7- 400
Driver for Interbus S Generation 4, Interbus S Based on Interbus PC cards from Generation 4 (I/O Phoenix Contact Interbus S driver ZT-INTERNT A Bussystem Interbus Phönic Contact communication) (www.phoenixcontact.com).
Direct driver for all ProConOS All Control based Controll systems from Systems from Phoenix Contact. Phoenix Contact
W ww.phoenixcontact.com based on
ProConOS, e.g. Inline Controller Phoenix Contact (ILC),Remote Phoenix Contact ZT-PHOENIX32 B Ethernet ProConOS driver Field Controller (RFC) , PC- Interface Cards (FC) etc. except: the serie 100 is not supported.
Driver for Pilz-PSS PLCs for ST PSS PLCs Pilz PILZ-PSS driver ZT-PSS32 A area, FS area is not supported. Serial PSS PG (www.pilz.com)
Driver for the S5 TCP/IP
communication. The driver Siemens S5,
supports polling (SEND/RECEIVE) Siemens S7 (only
Process- and spontaneous communication with VIPA S5 TCP-IP driver ZT-S5TCP32 B Ethernet TCP/IP Informatik (FETCH/WRITE). (www.vipa.de, CP443), Vipa www.siemens.de, www.inat.de, System 300 www.process-informatik.de)
Driver for S7 PLCs via MPI / H1 / Profibus DP / TCP/IP. Based on the Siemens S7 Profibus DP, MPI, Process- S7 driver Softnet 300/400 and other Ethernet, PC Slot TCP/IP - ZT-S7NT B software SIMATIC NET (Softnet) Informatik based from Siemens. (www.siemens.com) compatible PLCs Card RFC1006, ISO 8073
Driver for S7 TCP/IP connection via Siemens S7 200, standard network card without 300, 400 and Process- 1200 or VIPA TCP/IP - S7 TCP-IP driver ZT-S7TCP C additional software. The driver Ethernet Informatik supports Simatic PDiag. 200V, 300V, 300S RFC1006 (www.siemens.com) and 500S
Generic CIF driver for Interbus and Profibus DP cards from Hilscher
(www.hilscher.com). The driver can All Profibus DP
Hilscher CIF be configured as master or as slave resp. Interbus bus Profibus DP, Profibus DP ZT-CIF32 A Bussystem driver and communicates with the bus participants. Interbus participants on the data level without protocol.
Driver for the Keba / Hilscher PLCs with Universal Bus Gatway CP001. according CP001 Gateway interface and Profibus DP, Profibus DP ZT-CP001 A Supports communication via Serial driver Profibus, Interbus usw. Expander Interbus program
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Developed for special Moeller Profibus DP Profibus DP participant. Also can Slaves (Only participants, Profibus DP communicate with other passive Profibus DP ZT-DPUNI32 C which need no PC Slot Card Profibus DP Master driver Profibus DP participants. Better alternative: straton with Profibus DP own driver. configuration) Driver for PCS807 communication
box from Lauer for communication S5 or S7 PLC via PCS807 Profibus Profibus DP ZT-PCS80732 A via ProfibusDP. (www.systeme- Profibus-DP Serial Profibus DP DP driver lauer.de)
Driver for S7 PLCs via MPI / H1 / Profibus DP / TCP/IP. Based on the Siemens S7 Profibus DP, MPI, S7 driver Softnet 300/400 and other Ethernet, PC Slot TCP/IP - Profibus DP ZT-S7NT B software SIMATIC NET (Softnet) based from Siemens. (www.siemens.com) compatible PLCs Card RFC1006, ISO 8073
Profibus FMS driver. Based on the PLCs with
FMS with PC card software SIMATIC NET (Softnet) Profibus FMS Profibus FMS ZT-FMSNT C PC Slot Card Profibus FMS from Siemens from Siemens. (www.siemens.com) assembly group
Driver for robots of Reis Robotics Reis Robotics Reis RS IV Reis ZT-REIS32 A (www.reisrobotics.com) Serial Reis RS IV driver
Supports all connections which are Allen Bradley PLC DataHighway available with RS Linx types: PLC2, Serial, Plus, DeviceNet, Allen Bradley RS- (http://www.software.rockwell.com) PLC3, PLC5, Rockwell ZT-ALLENBNT A Bussystem, DataHighway, Linx driver PLC5250, Ethernet DF1, TCP/IP, SLC500; ControlNet
For all Allen Bradley PLCs All Allen Bradley Allen Bradley DF1- PLCs with DF1 Rockwell ZT-ALLENDF1 A supporting DF1. The driver works Serial DF1 driver half duplex interface
Ethernet/IP driver for communication via Common Industrial Protocol - CIP from Open DeviceNet Vendor Organisation
(ODVA) with Allen-Bradley Logix Allen-Bradley
PLCs. The driver supports direct ControlLogix, EtherNet/IP, Allen-Bradley browsing of variables from the PLC, CompactLogix Rockwell ZT-LOGIX_ODVA C Ethernet Common ODVA driver offline browsing from projectfile and MicroLogix Industrial Protocol (*.L5K) and blockread/write for all PLCs datatypes including structures and arrays.
W ww.ab.com
Driver for serial comunication with a System 9000TS Sequence of
Events Recorder or a Series 725B System 9000TS RTKInstruments RTK9000 driver ZT-RTK9000 B Combined Annunciator and Event and Series 725B Serial RTKAMS Recorder from RTK Instruments (www.rtkinstruments.com)
Driver for direct SAIA SBUS: PCD1.MXXX; communication via PGU,SBUS, PCD2.MXXX; P800 and TCP, but not via modem. PCD3MXXX; No SAIA software needed. PCD4.MXXX; (www.saia-burgess.com) PCD6.MXXX; PCS1.CXXX TCP/IP: PCD1.M130 with
PCD7.F650
module;
Saia Directly PCD2.M150 with TCP/IP, SAIA S- Saia ZT-SADIR A Serial, Ethernet driver PCD7.F650 Bus, SAIA P800 module; PCD2.M170 with PCD7.F650 module; PCD4.M170 with PCD7.F650 module; PCD6.M300 with PCD7.F651 module; PCD3
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Driver for PGU,SBUS, P800, SBUS: PCD1.MXXX; modem, TCP. Whereby PCD2.MXXX; communication via TCP is possible PCD4.MXXX; with one PLC per driver. (www.saia- PCD3MXXX; burgess.com) PCD6.MXXX; PCS1.CXXX TCP/IP: PCD1.M130 with
PCD7.F650
module;
SAIA2ND32 PCD2.M150 with TCP/IP, SAIA S- Saia ZT-SATCP B Serial, Ethernet driver PCD7.F650 Bus, SAIA P800 module; PCD2.M170 with PCD7.F650 module; PCD4.M170 with PCD7.F650 module; PCD6.M300 with PCD7.F651 module The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850
protocol, using server/client IEC 61400-25-4
IEC 61400-25-4 ZT-IEC61400-25- services via TCP/IP (profile A1/T1). Annex C SAT R Ethernet IEC 61850 Annex C 4-C The driver acts as Client (Master) compatible Server during comunication. The driver supports Reporting (unbuffered and buffered).
The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850 protocol, using server/client services via TCP/IP (profile A1/T1). IEC 61850 SAT IEC 61850 driver ZT-IEC61850 R The driver acts as Client (Master) compatible PLCs Ethernet IEC 61850 during communication. The driver supports Reporting (unbuffered and buffered).
Driver for the IEC 60870-5-101 PLCs supporting
(serial) and the IEC 60870-5-104 the IEC 60870-5-
IEC 60870-5- (TCP/IP) protocol; a Master 101 or the IEC IEC 60870-5-104, SAT ZT-IEC870 C Serial, Ethernet 101_104 driver (controlling station) 60870-5-104 IEC 60870-5-101 protocol.
Driver for 3964R/RK512 All PLCs supporting 3963R/RK512;
e.g. Siemens
S5/S7 with according CP or CPU; Schleicher 3964R-RK512 Sauter ZT-3964R32 A P03 via RK512. Serial 3964R/RK512 driver With Helmholz Adapter communication with all PLCs with MPI support possible.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
Modbus TCP/IP. gateways - read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE
GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over Schiele ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
The driver supports the protocol "Modbus RTU" over a serial All PLCs connection and over a TCP/IP supporting Modbus RTU - Modbus RTU, serial, Open Modbus RTU and connection and the protocol "Open Open Modbus Modbus TCP, Schiele Open Modbus ZT-MODRTU32 A Modbus TCP" for TCP/IP Serial, Ethernet TCP/IP or Modbus RTU over TCP connection. The driver acts as a Modbus Master. (For a Modbus Modbus TCP, Modbus Slave please use the Process ASCII(seriell) ASCII - serial Gateway)
Driver for Systron S400 Schiele Systron Schiele S400 Schiele ZT-S432 A S400 Serial unknown driver Driver for Systron S800 Schieles Systron Schiele S800 Schiele ZT-S80032 A S800 Serial unknown driver
Driver for 3964R/RK512 All PLCs supporting 3963R/RK512;
e.g. Siemens
S5/S7 with according CP or CPU; Schleicher 3964R-RK512 Schleicher ZT-3964R32 A P03 via RK512. Serial 3964R/RK512 driver With Helmholz Adapter communication with all PLCs with MPI support possible.
Driver for all Applicom interface All PLCs, which
cards, which support MPI or support MPI resp. Schneider Applicom driver ZT-APPL B Bussystem MPI, Modbus Plus Modbus Plus. (http:\\www.applicom- Modbus Plus int.com)
Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
Modbus TCP/IP. gateways - read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over Schneider ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Connection to Modicon TSX PLC Modicon TSX via Unitelway protocol. Modicon TSX Schneider ZT-MODICON A Serial Unitelway Micro driver (www.schneider-electric.de)
The driver supports the protocol "Modbus RTU" over a serial All PLCs connection and over a TCP/IP supporting Modbus RTU - Modbus RTU, serial, Open Modbus RTU and connection and the protocol "Open Open Modbus Modbus TCP, Schneider Open Modbus ZT-MODRTU32 A Modbus TCP" for TCP/IP Serial, Ethernet TCP/IP or Modbus RTU over TCP connection. The driver acts as a Modbus Master. (For a Modbus Modbus TCP, Modbus Slave please use the Process ASCII(seriell) ASCII - serial Gateway)
PDNet from the company Apex Schneider (www.apex.de), PDnet stands for Modicon PLCs: Process Data Transport Net and in TSX Compact the lower communication levels is A120, TSX
based on Arcnet. Compact Micro, TSX A250, A350, A500, TSX Bussystem, PDNet PCI - Quantum. ABB Schneider ZT-PADNETPCI A Coaxialcable PDNet driver Protronic PLCs: RG62/U T200, CS31, AC31. Siemens PLCs: S5-115U, S5-135U, S5- 155U, S7-300, S7- 400
Driver for the connection to products of SE-Elektronic. (www.se- A, B and C- bus Driver for SE- devices of SE SE Elektronic ZT-SE_32 R elektronic.de). The driver supports Serial unknown Elektronic A, B and C devices Elektronic
Driver for 3964R/RK512 All PLCs supporting 3963R/RK512;
e.g. Siemens
S5/S7 with according CP or CPU; Schleicher 3964R-RK512 Siemens ZT-3964R32 A P03 via RK512. Serial 3964R/RK512 driver With Helmholz Adapter communication with all PLCs with MPI support possible.
Driver for all Applicom interface All PLCs, which
cards, which support MPI or support MPI resp. Siemens Applicom driver ZT-APPL B Bussystem MPI, Modbus Plus Modbus Plus. (http:\\www.applicom- Modbus Plus int.com)
This driver comunicates to one or more BACnet devices (BACnet-
Automation stations) using All PLCs with
BACnet driver BACnet/IP protocol. The connected BACnet/IP Siemens ZT-BACNETNG C Ethernet BACnet/IP Next Generation BACnet devices have to be support. operated as BACnet servers. The driver implements only client functionalities.
Driver for MPI Siemens CE platform Siemens S7300
S7 MPI for (http://www.open-platform- /400 and Siemens Siemens CE ZT-MPI A program.com/products/default.asp) compatible with Bussystem MPI terminals MPI interface.
Driver for Hilscher Netlink Adapter Siemens S7-
(MPI -> TCP/IP) or Hilscher CIF-PB PLCs or
cards. The Netlink Adapter is also compatible PLCs
Hilscher MPI available identical in construction (e.g. VIPA) with Ethernet, PC Slot Siemens ZT-OPENMPI A MPI driver from IBH and Helmholz. MPI interface. Card (http://www.hilscher.com) The PLC must be MPI Master.
Driver for CTI PLCs,, Texas
Instruments TI 505 PLCs or Simatic CTI PLCs, Ti505,
545/555 PLCs. The driver support Simatic 545, Siemens CTI driver ZT-CTI B Ethernet NITP, CAMP the protocols CAMP and NITP with Simatic 555 Packed Task Codes.
Driver for ESA W indows CE Siemens S7-
terminal including ESA PCI CIB PLCs or
communication card for W indows compatible PLCs Driver for ESA Siemens ZT-ESA32 A CE for the communication with (e.g. Vipa) with Local MPI PCI CIB PLCs supporting MPI. S7 functions via MPI.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Profibus FMS driver. Based on the PLCs with software SIMATIC NET (Softnet) FMS with PC card Profibus FMS Siemens ZT-FMSNT C PC Slot Card Profibus FMS from Siemens from Siemens. (www.siemens.com) assembly group
Driver for the MPI->HMI adapter Siemens S7-
from Siemens or Helmholz PLCs or
compatible PLCs HMI adapter Siemens ZT-S7HMI A (e.g. VIPA) with Serial MPI driver S7 functions via MPI.
Driver for read out of values from energy meters. The driver uses IEC 62056-21 or IEC 61107 IEC-62056-21 protocol A of IEC 62056-21 IEC 62056-21, Siemens ZT-IEC62056 B compatible enrgy Serial, Ethernet Driver specification. The driver supports IEC 61107 read only comunication. meter
The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850
protocol, using server/client IEC 61400-25-4
IEC 61400-25-4 ZT-IEC61400-25- services via TCP/IP (profile A1/T1). Annex C Siemens R Ethernet IEC 61850 Annex C 4-C The driver acts as Client (Master) compatible Server during comunication. The driver supports Reporting (unbuffered and buffered).
The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850 protocol, using server/client services via TCP/IP (profile A1/T1). IEC 61850 Siemens IEC 61850 driver ZT-IEC61850 R The driver acts as Client (Master) compatible PLCs Ethernet IEC 61850 during communication. The driver supports Reporting (unbuffered and buffered).
Driver for the IEC 60870-5-101 PLCs supporting
(serial) and the IEC 60870-5-104 the IEC 60870-5-
IEC 60870-5- (TCP/IP) protocol; a Master 101 or the IEC IEC 60870-5-104, Siemens ZT-IEC870 C Serial, Ethernet 101_104 driver (controlling station) 60870-5-104 IEC 60870-5-101 protocol.
PDNet from the company Apex Schneider (www.apex.de), PDnet stands for Modicon PLCs: Process Data Transport Net and in TSX Compact the lower communication levels is A120, TSX
based on Arcnet. Compact Micro, TSX A250, A350, A500, TSX Bussystem, PDNet PCI - Quantum. ABB Siemens ZT-PADNETPCI A Coaxialcable PDNet driver Protronic PLCs: RG62/U T200, CS31, AC31. Siemens PLCs: S5-115U, S5-135U, S5- 155U, S7-300, S7- 400
Driver for PCS807 communication
box from Lauer for communication S5 or S7 PLC via PCS807 Profibus Siemens ZT-PCS80732 A via ProfibusDP. (www.systeme- Profibus-DP Serial Profibus DP DP driver lauer.de)
Driver for PCS812 communication Siemens S7-
box from Lauer for communication PLCs or
PCS812 S7 via MPI. (www.systeme-lauer.de) compatible PLCs Siemens ZT-PCS812 A Serial MPI connection (e.g. VIPA) with MPI interface
H1 protocol driver for Siemens S5. H1 resp. "Industrial Ethernet" is the protocol name for the cellular network, which is based on the 7- Siemens S5 Siemens S5 H1 driver ZT-S5H1NT B layer-model of the ISO/OSI Ethernet H1 standard. (www.vipa.de, www.siemens.de, www.inat.de). At PC you need the PC H1 Driver from INAT.
Driver for the programming Siemens Simatic Siemens S5 PD interface of the Simatic S5 from Siemens ZT-S5PG32 A S5 Serial AS 511 driver Siemens with AS 511 protocol. (www.siemens.com)
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Driver for the S5 TCP/IP
communication. The driver Siemens S5,
supports polling (SEND/RECEIVE) Siemens S7 (only
and spontaneous communication with VIPA Siemens S5 TCP-IP driver ZT-S5TCP32 B Ethernet TCP/IP (FETCH/WRITE). (www.vipa.de, CP443), Vipa www.siemens.de, www.inat.de, System 300 www.process-informatik.de)
Connection to Siemens S7 200 Siemens S7 CPU- S7 driver for S7- Siemens ZT-S7PPI200 A PLCs 212 Serial PPI 200 Driver for the MPI-ISA card from Siemens S7300 Lauer for communication with a S7 /400 and Siemens S7_MPIISA driver ZT-S7MPIISA A PLC. (www.lauer-systeme.de) compatible with PC Slot Card MPI MPI interface.
Driver for S7 PLCs via MPI / H1 / Profibus DP / TCP/IP. Based on the Siemens S7 Profibus DP, MPI, S7 driver Softnet 300/400 and other Ethernet, PC Slot TCP/IP - Siemens ZT-S7NT B software SIMATIC NET (Softnet) based from Siemens. (www.siemens.com) compatible PLCs Card RFC1006, ISO 8073
Driver for the communication with a Software PLC
Siemens Soft PLC (WINAC). WinAC or
(www.siemens.com) SlotPLCW inAC Siemens WINAC driver ZT-S7AC41x32 B Local unknown Pro or W inAC Pro Lite from Siemens
Driver for communication with S7-300, S7400, Siemens Siclimat X Decos ZT-S7DCOS R Siclimat X Building Automation Unknown unknown System, Siemens AG
For the serial communication via the Siemens PC adapter / Helmholz PC
adapter to Siemens and Vipa PLCs Siemens S7
PC Adapter - Vipa ZT- with MPI interface. Alternativ: Serial 300/400 CPUs, all Siemens PC- Siemens A Serial Green Cable S7PCADAPTER communication to Vipa PLCs via the VIPA CPUs Protocol Vipa Green Cable to the Vipa PD interface.
Driver for S7 TCP/IP connection via Siemens S7 200, standard network card without 300, 400 and 1200 or VIPA TCP/IP - Siemens S7 TCP-IP driver ZT-S7TCP C additional software. The driver Ethernet supports Simatic PDiag. 200V, 300V, 300S RFC1006 (www.siemens.com) and 500S
Driver for the Siemens Sigmasys fire alarm centre. Spontaneou slave Siemens Siemens Sigmasys Siemens ZT-SIGMASYS R driver based on the GMA Manager Ethernet unknown Sigmasys driver (Destination Management System) TOPSIS
Driver for S7 Simotion D4x5
connection via standard network Siemens Simotion
card without additional software. D425/D435/D445 Siemens Simotion driver ZT-SIMOTION B Ethernet TCP/IP Offline variable import from CPUs Siemens Scout file possible. (www.siemens.com)
Driver for the communication via a Siemens S7 and other PLCs Siemens SST Driver ZT-SST A MPI net throuh a SST Interface PC Slot Card MPI Card. (www.mysst.com) supporting MPI
Connection to the Siemens process AS220,AS220E,A control system TELEPERM M / ME S220EA,AS220E via the SYNO®gate 300 IP from HF,EAK,AS230,A Siemens Teleperm driver ZT-TELEPERM32 B Synotec (Vertrieb: www.psg- S235,AS231,MS2 Ethernet TCP/IP gmbh.de) 36,AG150U,AG15 5U,AS215
Driver for Texas Instruments TI 505 TI 505 - 545 / 545. Protocols: TBP,NITP, TCP/IP TI 505 and 545 TCP/IP, TBP, Siemens ZT-TI500 A Serial, Ethernet driver NITP
Driver for communication with VIPA Siemens S7-
Windows CE Touch Panel with PLCs or
integrated S7-Chip for PLC compatible PLCs Driver for VIPA Siemens ZT-VIPA32 A connected trough MPI. (eg. Vipa) with " Bussystem, Local MPI CE touchpanel S7 functions" over MPI.
Connection to Sigmatek products Serial, Sigmatek DIAS Sigmatek SIGMATEK driver ZT-SIGMA32 A (www.sigmatek.at) Bussystem, unknown Ethernet Connection to all Sigmatek PLCs, All Sigmatek
which can be engineered with the PLCs supporting Sigmatek Lasal Serial, Ethernet, Sigmatek ZT-STLASAL A engineering software LASAL. the Sigmatek Sigmatek Lasal Driver CAN Bus Adapter Lasal protocol.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Driver for Sinthesi PICnet PLCs
(www.sinthesi.com).The driver uses PICnet PLCs from Sinthesi PICnet driver ZT-SINTH A the SAPP (Sinthesi Asynchronous Sinthesi Serial SAPP Packet Protocol) protocol
Driver for communication with Devices SNMP, SNMPv1, SNMP SNMP Driver ZT-SNMP C devices supporting SNMP. supporting SNMP Ethernet SNMPv2c
Arcnet driver for ABB PLCs based ABB PLC of the series 07KTxx ARCNET - Driver on Arcnet Interface Card from So Coaxialcable So Hard ZT-ARCNETNT A with Arcnet Arcnet for ABB Hard RG62/U connection
The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850
protocol, using server/client IEC 61400-25-4
Sprecher IEC 61400-25-4 ZT-IEC61400-25- services via TCP/IP (profile A1/T1). Annex C R Ethernet IEC 61850 Automation Annex C 4-C The driver acts as Client (Master) compatible Server during comunication. The driver supports Reporting (unbuffered and buffered).
The IEC61850 Client driver. The communication between driver and PLC is based on the IEC 61850 protocol, using server/client IEC 61850 Sprecher services via TCP/IP (profile A1/T1). IEC 61850 driver ZT-IEC61850 R compatible PLCs Ethernet IEC 61850 Automation The driver acts as Client (Master) during communication. The driver supports Reporting (unbuffered and buffered).
Driver for the IEC 60870-5-101 PLCs supporting
(serial) and the IEC 60870-5-104 the IEC 60870-5-
Sprecher IEC 60870-5- (TCP/IP) protocol; a Master 101 or the IEC IEC 60870-5-104, ZT-IEC870 C Serial, Ethernet Automation 101_104 driver (controlling station) 60870-5-104 IEC 60870-5-101 protocol.
The driver writes values from selected variables into a dedicated
Write variable table of a SQL database. The ODBC databases SQL ZT-ExportSQL B Local ODBC values in SQL driver communicates via ODBC connection.
The driver is used for the SQL database SQL SQL Driver ZT-SQLDRV A bidirectional data exchange with a supporting ODBC Ethernet, Local SQL SQL database supporting ODBC.
Driver for the communication via a Siemens S7 and other PLCs SST SST Driver ZT-SST A MPI net throuh a SST Interface PC Slot Card MPI Card. (www.mysst.com) supporting MPI
Driver for straton connection. straton straton straton driver ZT-STRATON - Ethernet, Local TCP/IP Driver for communication with straton PLCs. Replaces straton 32 driver. The driver can use several PLCs based on straton straton NG driver ZT-StratonNG A connections at the same time and the straton VMTK. Ethernet TCP/IP uses an improved communication concept.
Connection to a Futrit PLC ACADA 70. The driver supports modem Futurit ACADA 70 Swarco Futurit Swarco Futurit ZT-FUTURIT B Serial FuturitCom connection
Connection to the Siemens process AS220,AS220E,A control system TELEPERM M / ME S220EA,AS220E via the SYNO®gate 300 IP from HF,EAK,AS230,A Synotec Teleperm driver ZT-TELEPERM32 B Synotec (Vertrieb: www.psg- S235,AS231,MS2 Ethernet TCP/IP gmbh.de) 36,AG150U,AG15 5U,AS215
Telco200Z - Telecontrol central station in combination with telephone communication. Telco200Z, Telco Telco200 driver ZT-TELCO_32 A Dataexchange for online and Telco210Z Serial unknown historical data is possible. CTi GmbH, www.ctiweb.de
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
Modbus TCP/IP. gateways - read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE
GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over Telemecanique ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
Connection to Modicon TSX PLC Modicon TSX Modicon TSX Telemecanique ZT-MODICON A via Unitelway protocol. Serial Unitelway Micro driver (www.schneider-electric.de)
The driver supports the protocol "Modbus RTU" over a serial All PLCs connection and over a TCP/IP supporting Modbus RTU - Modbus RTU, serial, Open Modbus RTU and connection and the protocol "Open Open Modbus Modbus TCP, Telemecanique Open Modbus ZT-MODRTU32 A Modbus TCP" for TCP/IP Serial, Ethernet TCP/IP or Modbus RTU over TCP connection. The driver acts as a Modbus Master. (For a Modbus Modbus TCP, Modbus Slave please use the Process ASCII(seriell) ASCII - serial Gateway) Driver for CTI PLCs,, Texas
Instruments TI 505 PLCs or Simatic CTI PLCs, Ti505,
Texas 545/555 PLCs. The driver support Simatic 545, CTI driver ZT-CTI B Ethernet NITP, CAMP Instruments the protocols CAMP and NITP with Simatic 555 Packed Task Codes.
Driver for Texas Instruments TI 505 Texas TI 505 - 545 / 545. Protocols: TBP,NITP, TCP/IP TI 505 and 545 TCP/IP, TBP, ZT-TI500 A Serial, Ethernet Instruments driver NITP
Driver for the Slot PCL SPCx00 Driver for Slot SPC-xx needed TRSystemtechnik ZT-SPCNT A from TR-Systemtechnik (tr- Local unknown PCL SPCx00 systemtechnik.de)
Driver for the direct connection to a IQ xxx Trend Attribut Trend Trend Driver ZT-TREND32 A trend PLC Serial Comunication The driver has the same functionality as driver Trend32. It is however based on driver Trend TCC-Suite. W ith this it can
communicate not only a serial IQ xxx Trend Trend NG driver ZT-TrendNG A interface but also via all Serial, Ethernet unknown communication types (e.g. TCP/IP, Modem) the TCC-Suite supports (www.trendcontrols.com)
Driver for comunication with devices in packaging and process industry VDMAXML_P using VDMAXML_P Protocoll e.g.: compatible PLCs Laetus components. or devices; VDMA VDMA-XML driver ZT-VDMA_XML B Www.vdma.org, www.laetus.com Laetus devices Ethernet VDMAXML_P with VDMA-XML interface server.
Driver for ESA W indows CE Siemens S7-
terminal including ESA PCI CIB PLCs or
communication card for W indows compatible PLCs Driver for ESA Vipa ZT-ESA32 A CE for the communication with (e.g. Vipa) with Local MPI PCI CIB PLCs supporting MPI. S7 functions via MPI.
Driver for the MPI->HMI adapter Siemens S7-
from Siemens or Helmholz PLCs or
compatible PLCs HMI adapter Vipa ZT-S7HMI A (e.g. VIPA) with Serial MPI driver S7 functions via MPI.
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Driver for PCS812 communication Siemens S7-
box from Lauer for communication PLCs or
PCS812 S7 via MPI. (www.systeme-lauer.de) compatible PLCs Vipa ZT-PCS812 A Serial MPI connection (e.g. VIPA) with MPI interface
H1 protocol driver for Siemens S5. H1 resp. "Industrial Ethernet" is the protocol name for the cellular network, which is based on the 7- Siemens S5 Vipa S5 H1 driver ZT-S5H1NT B layer-model of the ISO/OSI Ethernet H1 standard. (www.vipa.de, www.siemens.de, www.inat.de). At PC you need the PC H1 Driver from INAT. Driver for the S5 TCP/IP communication. The driver Siemens S5,
supports polling (SEND/RECEIVE) Siemens S7 (only
and spontaneous communication with VIPA Vipa S5 TCP-IP driver ZT-S5TCP32 B Ethernet TCP/IP (FETCH/WRITE). (www.vipa.de, CP443), Vipa www.siemens.de, www.inat.de, System 300 www.process-informatik.de)
Driver for S7 PLCs via MPI / H1 / Profibus DP / TCP/IP. Based on the Siemens S7 Profibus DP, MPI, S7 driver Softnet 300/400 and other Ethernet, PC Slot TCP/IP - Vipa ZT-S7NT B software SIMATIC NET (Softnet) based from Siemens. (www.siemens.com) compatible PLCs Card RFC1006, ISO 8073
For the serial communication via the Siemens PC adapter / Helmholz PC
adapter to Siemens and Vipa PLCs Siemens S7
PC Adapter - Vipa ZT- with MPI interface. Alternativ: Serial 300/400 CPUs, all Siemens PC- Vipa A Serial Green Cable S7PCADAPTER communication to Vipa PLCs via the VIPA CPUs Protocol Vipa Green Cable to the Vipa PD interface.
Driver for S7 TCP/IP connection via Siemens S7 200, standard network card without 300, 400 and 1200 or VIPA TCP/IP - Vipa S7 TCP-IP driver ZT-S7TCP C additional software. The driver Ethernet supports Simatic PDiag. 200V, 300V, 300S RFC1006 (www.siemens.com) and 500S
Driver for communication with VIPA Siemens S7-
Windows CE Touch Panel with PLCs or
integrated S7-Chip for PLC compatible PLCs Driver for VIPA Vipa ZT-VIPA32 A connected trough MPI. (eg. Vipa) with " Bussystem, Local MPI CE touchpanel S7 functions" over MPI.
Internal driver which gives back every set value as actual value with unchanged value but new time stamp. Status bits for Cause of
Transmission are also changed. no PLC Internal driver Volkswagen ZT-Reflect A This guarantees that when writing connection Local unknown with time stamp set values with the same value and same time stamp (VBA/VSTA), the value is recognized as a changed value and is therefore passed on
Telco200Z - Telecontrol central station in combination with telephone communication. Telco200Z, Vollmer Telco200 driver ZT-TELCO_32 A Dataexchange for online and Telco210Z Serial unknown historical data is possible. CTi GmbH, www.ctiweb.de
Windows
-
type
/
7
name
/
group
Category Article number Description PLC Types
protocol
2003
Mobile
/
/
Communi
Vista
Price
Driver
cation
Windows
XP
Connection
CE Open Modbus TCP/IP driver with the following differences compared to the standard Modbus driver: All controllers and - TCP/IP channel bundling gateways
- improved communication with supporting Open
Modbus TCP/IP. gateways - read and write only for holding Sequence of register Events is only - supports only Open Modbus available for TCP/IPprotocol AREVA MiCOM - Sequence of Events for AREVA P126/P127, GE MiCOM 126/127, GE Multilin F650, Multilin F650, GE
GE Multilin UR-series, ICE NPx800, Multilin UR-series, Modbus Energy Modbus RTU over W ago ZT-MODBUS_E C Schneider MODICON TSX ICE NPI 800, ICE Ethernet driver TCP Premium with COSTRONIC NPID 800 and Software Schneider MODICON TSX www.areva-td.com, (Premium,M340, www.gedigitalenergy.com, Quantum) with www.groupeice.com, Function block www.costronic.ch (DFB) from Costronic and Schneider Sepam Protection Relais.
The driver supports the protocol "Modbus RTU" over a serial All PLCs connection and over a TCP/IP supporting Modbus RTU - Modbus RTU, serial, Open Modbus RTU and connection and the protocol "Open Open Modbus Modbus TCP, W ago Open Modbus ZT-MODRTU32 A Modbus TCP" for TCP/IP Serial, Ethernet TCP/IP or Modbus RTU over TCP connection. The driver acts as a Modbus Master. (For a Modbus Modbus TCP, Modbus Slave please use the Process ASCII(seriell) ASCII - serial Gateway)
Driver for straton connection. straton W ago straton driver ZT-STRATON - Ethernet, Local TCP/IP Driver for communication with straton PLCs. Replaces straton 32 driver. The driver can use several PLCs based on W ago straton NG driver ZT-StratonNG A connections at the same time and the straton VMTK. Ethernet TCP/IP uses an improved communication concept.
Driver for internal variables. Variables can be local resp. global zenon system Driver for internal and can be started with an initial - - - Local unknown driver variables value or with the last value (remanence). The driver does not use up I/Os or TAGs.
zenon Mathematics driver. For Driver for zenon system numerical and binary operations. - Mathematics - - Local unknown driver The driver does not use up I/Os or variable TAGs.
zenon Simulation driver for
Driver for simulation and internal variables. zenon system - simulator - - Variables also can be saved Local unknown driver variables remant. The driver does not use up I/Os or TAGs.
zenon System driver for displaying internal project information, network information, hardware information of zenon system Driver for system - - - the PC etc. The driver does not use Local unknown driver variables up I/Os or TAGs. zenon 7
zenon Logic Fieldbus drivers
Windows
-
/
7
name
group /
Category Article number Description PLC Types protocol
/
type
2003
/
CE
Communi
Vista
Price
Connection
Mobile
Driver
cation
XP Windows
Driver for Applicom IO cards (Direct Modbus RTU - serial, Profibus Applicom IO Link) - Applicom ST-AppIO T PC Slot Card DP, Can Open, configuration DeviceNet, ControlNet K-Bus driver for Driver for Beckhoff CX1000 with K- - Beckhoff ST-CX1000 T Local K-Bus CX1000 Bus
For Bihl+Widemann AS-i - Serial, PC Slot Bihl+Widemann AS-interface ST-Asi T AS-i configurations Card Brodersen - - Brodersen ST-IOTools T Serial proprietary IOTOOLS Driver for so called super-global Win32 Shared - COPA-DATA ST-Win32 T variables exchanged between two Local proprietary memory straton RT instances
Internal straton peripheral driver -
Shared Memory dreiber; may only
straton to zenon be use once on a computer! This - COPA-DATA - - Local proprietary RT connection driver must be configured in the straton project if a zenon variable is set to "externally visible" Driver for Hilscher fieldbus boards; the configuration is doen via Open Modbus Hilscher configuration software TCP, Profinet, Hilscher SYCON "SYCON.net". The configuration file - Hilscher ST-CIFX T PC Slot Card EtherCAT, CifX has to be exported as XML in EtherNet/IP, SYCON.net and imported in straton Sercos III fieldbus configuration.
Driver for Hilscher Profibus DP Hilscher CIF cards (CIF 30, 40, 50, 60, 104). The - Hilscher ST-ProfDP T PC Slot Card Profibus DP Profibus configuration is done via straton fieldbus configurator. Driver for Hilscher Fieldbuscards, the configuration is done via Profibus DP, Hilscher configuration software Hilscher SYCON - Interbus, Can Hilscher ST-Sycon T "SyCon". The configuration is PC Slot Card configuration Open, DeviceNet, exported with SyCon and importet in ControlNet the straton fieldbus configurator.
Driver for HMS fieldbus cards, the
HMS configuration is done via HMS - Profibus DP, HMS ST-HMS T PC Slot Card configuration cKonfiguration software DeviceNet, AS-i
Driver for Wago I/O System 758
ThinkIO/IOSystem (Wago IPC) bzw. Kontron ThinkIO - Kontron ST-THINKIO T Bussystem proprietary 758 with Windwos CE 5.0
communikation with I/O Modules Melsec Mitsubishi Q C- using C-CPU of the Melsec Q-Serie Mitsubishi ST-QBF - Q12DCCPU-V Bussystem unknown CPU via backplane bus.
Driver for Modbus Master protocol Modbus RTU - MODBUS Master - Open Modbus ST-MBMASTER T Serial, Ethernet serial, Open protocol Modbus TCP Driver for Modbus Slave protocol Modbus RTU - MODBUS Slave - Open Modbus ST-MBSLAVE T Serial, Ethernet serial, Open protocol Modbus TCP Driver for Phoenix Contact Interbus - Phoenix Contact Interbus-S ST-PHOEINTER T Card PC Slot Card Interbus
straton driver for the communication
ST- with Profinet devices. - Profinet ProfiNet IO RT T Ethernet Profinet PROFINETIORT
To communicate with I/O Modules SIMATIC S7- of SIMATIC S7 300 series via the modular Embedded backplane bus of the mEC31 Controller, I/O Siemens SIMATIC S7-mEC ST-S7mEC31 - controller Bussystem proprietary Module for SIMATIC S7 300 Serie
Driver for Siemens Profibus Master SoftNet - Siemens ST-SOFTNET T cards Local Profibus DP ProfibusDP Driver for Wago I/O System 758 ThinkIO/IOSystem (Wago IPC) bzw. Kontron ThinkIO - Wago ST-THINKIO T Bussystem proprietary 758 with Windwos CE 5.0
Driver for Applicom IO cards (Direct Modbus RTU - serial, Profibus Applicom IO Link) - Woodhead ST-AppIO T PC Slot Card DP, Can Open, configuration DeviceNet, ControlNet