Calibration Manual Erie County Technical School CALIBRATION MANUAL 1. Purpose: 1.1. To establish and maintain a calibration system to control the accuracy of equipment that is used for measuring student performance evaluation, particularly state or national credentials. Including measuring equipment used for public health and safety purposes. 1.2. To prevent inaccuracy, detect deficiencies and provide for timely positive corrective action. 1.3. The instructor is responsible for overall control of the calibration system and designating “master” tools and equipment that are subject to calibration. Instructional tools and equipment may be checked against the “master” tools for accuracy, as the instructor deems necessary. 2. Procedure: 2.1. “Master” tools will be calibrated by means of certified standards or equipment that has been calibrated using certified standards. 2.2. Master gauge blocks will be used to calibrate the optical comparator in the Tool and Die lab. 2.3. A list of controlled, calibrated “master tools and equipment” is maintained by the instructor. Master tools are used to check instructional tools as the instructor deems is necessary. 2.4. Any gauge or tool is considered out of tolerance if it exceeds one reference mark or graduation, or as evaluated by the instructor. The instructor shall be informed of any out-of-tolerance condition found during use so that proper actions may be taken. 3. Calibration Frequency: 3.1. The Optical Comparator will be calibrated with the Master gauge blocks each year prior to the start of testing. 3.2. Tool and Die Lab measuring tools will be calibrated in accordance with National Institute of Metalworking Skills (NIMS) standards. Tools shall be calibrated at the beginning of any job requiring NIMS standards, or when the instructor determines it should be calibrated due to accuracy requirements for the specific job. 3.3. Culinary Arts food preparation equipment shall be calibrated for temperature accuracy every other year. Records of calibration shall be maintained in the Facility Manager’s office. 3.4. National Occupational Competetency Testing Institute (NOCTI) tools are to be calibrated prior to the test. Created 4/18/2002 Revised 5/6/05 Erie County Technical School CALIBRATION MANUAL 4. Calibration Standards: 4.1. Master gauge blocks used for calibration shall be kept in the Facility Manager’s office. Certification attesting to the accuracy of the Master Gauge Blocks shall be kept on file in the Facility Manager’s office. 5. Responsibility: 5.1. The instructors shall be responsible to identify and appropriately mark “master” measuring equipment used to check the accuracy of instructional measuring equipment. 6. Records: 6.1. Facility Manager shall log the calibration of Optical Comparator on the Equipment Calibration Log. The frequency of calibration and dates indicate the calibration was performed. The Facility Manager will maintain logs for 3 years. This record is maintained in the Facility Manager’s office and is available for review. 6.2. Instructors shall list the ID and description of equipment on the Equipment Calibration Logs. The frequency of calibration and dates indicate the calibration was performed. The Facility Manager will maintain logs for 3 years. This record is maintained in the Facility Manager’s office and is available for review. Created 4/18/2002 Revised 5/6/05 Erie County Technical School PROCEDURE FOR CALIBRATING BI-METALLIC STEMMED THERMOMETERS Before Calibrating Bi-metallic stemmed thermometers they must be checked for any signs of outward damage: 1. Bent stem 2. Broken lens 3. Loose nut If damaged remove from service. Calibration 1. First prepare a beaker with a 50/50 ice/water slush. 2. Insert thermometer into mixture, making sure that the dimple is submerged. 3. Let the thermometer stabilize for three to five minutes. 4 . Check temperature it should read 32°F. 5. If your reading is more than +/- 2°F you will need to recalibrate the thermometer. 6. To recalibrate you turn the calibration nut until indicator reads 32°F. 7. After calibration let the thermometer come to room temperature. 8. Then repeat steps 2 thru 7. 9. The thermometer will be considered out of tolerance if after 3 tries the thermometer will not hold the temperature of 32°F +/- 2°F. Created 4/18/2002 Revised 5/6/05 Erie County Technical School PROCEDURE FOR CALIBRATING INCH-METRIC MICROMETERS Before Calibrating micrometers they must be checked for any signs of outward damage: 1. Chipped measuring faces 2. Bent anvil 3. Loose or missing parts If damaged remove from service. Calibration 1. It is extremely important that all parts of the micrometer be kept clean during calibration. 2. Wipe micrometer clean with a clean cloth and apply a drop of fine oil to spindle. 3. First you will need to remove play/looseness from the threads due to wear in the spindle. 4. To do this back off the thimble. 5. Insert the C-spanner into the slot or hole of the adjusting nut. 6. Turn the adjusting nut clockwise until play between the threads has been eliminated. 7. Do not over tighten, the spindle should move freely when the ratchet stop or friction thimble is being turned. 8. Next you will need to test the accuracy of the micrometer. 9. You will need a gage block from the Master Gage Blocks for the size micrometer that you will be checking. 10. Open the micrometer so that the gage block will fit between the measuring faces. 11. Check to make sure that the measuring faces are clean and there are no chips in them. 12. Place the master gage block between the measuring faces. 13. Turn the thimble using the ratchet stop or friction thimble until the measuring faces contact the master gage block. 14. The reading of the micrometer must be the same +/- .0005 as the master gage block. 15. If the reading is more than +/- .0005 you will need to adjust the micrometer. 16. To adjust the micrometer close the measuring faces carefully until they contact the master gage block. 17. Insert the C-spanner into the hole or slot provided in the sleeve. 18. Carefully turn the sleeve until the index line on the sleeve coincides with the zero line on the thimble. 19. Recheck the accuracy of the micrometer by opening the micrometer and then closing the measuring faces carefully until they contact the master gage block again. 20. The micrometer will be considered out of tolerance if after 3 tries the micrometer will not hold the reading of the master gage block +/- .0005. 21. The micrometer will be considered out of tolerance if after repeating steps 10 thru 14 and the micrometer will not hold +/- .0005” it will then be removed from service. Created 4/18/2002 Revised 5/6/05 Erie County Technical School PROCEDURE FOR CALIBRATING VERNIER, DIAL OR DIGITAL CALIPERS Before calibrating calipers they must 1st be checked for any signs of damage: 1. Chipped or damaged measuring faces and points 2. Dirty or damaged track or gear 3. Numbers worn off and unreadable 4. Loose face 5. Not repeating back to “0” 6. Sticking, skipping or binding during operation of full travel If damaged remove from service and send for repair Calibration 1. Place a rag on a demagnetizer and run calipers over to remove magnetism 2. Clean calipers with a clean cloth and check for dirt and metal chips in track 3. A light air blast may be needed to remove chips 4. Close calipers and adjust “0” on face if needed 5. Get 3 gauge block stacks from the master set: Example: If checking a 6” caliper, use a 1-inch, a 3-inch and a 6-inch stack 6. Verify accuracy over the 3 stacks of gauge block 7. The caliper will be considered out or tolerance if after 3 tries over 3 stacks the caliper will not repeat within +/- .002 Created 4/18/2002 Revised 5/6/05 Erie County Technical School CALIBRATION PROCEDURE FOR A FRAMING SQUARE Before calibrating a framing square it must be checked for any signs of outward damage such as: 1. Cracks 2. Bends 3. Twists If damaged remove from service. Calibration 1. To check calibration of a framing square you will need to obtain the Master Framing Square from the instructor, so that you can compare the gradations and square ness of the framing square to the Master Framing Square. 2. If it is more than 1/16” out of square or the gradations are off by more than 1/16” you will need to recalibrate the framing square. 3. To recalibrate the framing square, if out of square you would either bend back to square or replace. 4. If the gradations are off remove from service there is no way to recalibrate this item. 5. The framing Square will be considered out of tolerance if after 3 tries it doesn’t hold to 1/16” of square. 6. Remove it from service. Created 4/18/2002 Revised 5/6/05 Erie County Technical School CALIBRATION PROCEDURE FOR A LASER LEVEL Before calibrating Laser Level it must be checked for any signs of outward damage such as: 1. Broken parts If damaged remove from service. Calibration 1. This tool is self-leveling. 2. If damaged remove from service there is no way to recalibrate this item. Created 4/18/2002 Revised 5/6/05 Erie County Technical School CALIBRATION PROCEDURE FOR A LEVEL Before Calibrating a Level it must be checked for any signs of outward damage such as: 1. Cracked vials. 2. Excess air in the vials 3. Bends or twists in the frame If damaged remove from service. Calibration 1. The level is self-checking by holding to a surface and then turning the level around to see if it read the same.
Recommended publications
  • Gauge Blocks and Accessories
    for more than 70 Made in Germany years Gauge Blocks and Accessories Wear resistant Special Steel Ceramic Carbide DAkkS-Calibration Laboratory scope of accreditation according to the current annexe: KOLB & BAUMANN GMBH & CO. KG www.dakks.de PRECISION MEASURING TOOLS MAKERS DE-63741 ASCHAFFENBURG · DAIMLERSTR. 24 GERMANY PHONE +49 (6021) 3463-0 · FAX +49 (6021) 3463-40 www.koba.de · [email protected] Catalogue No. 1000/E/01/2012 Dear Customer, Today you have the documents of KOLB & BAUMANN in your hands. We are glad that you are interested in our products. The foundations of KOBA were laid more than 70 years ago and at the beginning the manufacture of gauge blocks was the major line. At that time gauge blocks were made out of steel. Later carbide and ceramic were added. Furthermore we manufacture accessories in order to extend the application of our gauge blocks. In order to complete the product range we started the manufacture of gauges. It was in 1979 when KOLB & BAUMANN got accredited by the PTB as the 8th DKD-calibration laboratory in Germany. This accreditation comprises the measured value "length” up to 1000 mm. Besides, KOBA is accredited laboratory for gauges and other measuring instruments. KOBA supplies world-wide into more than 70 countries and is also supplier for gauge blocks and calibration masters to various National Physical Laboratories. Our world-wide customers trust in KOBA-gauge blocks and gauges as a high- grade German quality product. Being a German family-based company we will do all efforts to keep the confidence in our products.
    [Show full text]
  • The Gage Block Handbook
    AlllQM bSflim PUBUCATIONS NIST Monograph 180 The Gage Block Handbook Ted Doiron and John S. Beers United States Department of Commerce Technology Administration NET National Institute of Standards and Technology The National Institute of Standards and Technology was established in 1988 by Congress to "assist industry in the development of technology . needed to improve product quality, to modernize manufacturing processes, to ensure product reliability . and to facilitate rapid commercialization ... of products based on new scientific discoveries." NIST, originally founded as the National Bureau of Standards in 1901, works to strengthen U.S. industry's competitiveness; advance science and engineering; and improve public health, safety, and the environment. One of the agency's basic functions is to develop, maintain, and retain custody of the national standards of measurement, and provide the means and methods for comparing standards used in science, engineering, manufacturing, commerce, industry, and education with the standards adopted or recognized by the Federal Government. As an agency of the U.S. Commerce Department's Technology Administration, NIST conducts basic and applied research in the physical sciences and engineering, and develops measurement techniques, test methods, standards, and related services. The Institute does generic and precompetitive work on new and advanced technologies. NIST's research facilities are located at Gaithersburg, MD 20899, and at Boulder, CO 80303. Major technical operating units and their principal
    [Show full text]
  • For the Classification and Construction of Sea-Going
    RUSSIAN MARITIME REGISTER OF SHIPPING FOR THERULE CLASSIFICATIOS N AND CONSTRUCTION OF SEA-GOING SHIPS Part XIV WELDING Saint-Petersburg Edition 2017 Rules for the Classification and Construction of Sea-Going Ships of Russian Maritime Register of Shipping have been approved in accordance with the established approval procedure and come into force on 1 January 2017. The present twentieth edition of the Rules is based on the nineteenth edition (2016) taking into account the additions and amendments developed immediately before publication. The unified requirements, interpretations and recommendations of the International Association of Classification Societies (IACS) and the relevant resolutions of the International Maritime Organization (IMO) have been taken into consideration. The Rules are published in the following parts: Part I "Classification"; Part II "Hull"; Part in "Equipment, Arrangements and Outfit"; Part IV "Stability"; Part V "Subdivision"; Part VI "Fire Protection"; Part VIJ "Machinery Installations"; Part VHI "Systems and Piping"; Part IX "Machinery"; Part X "Boilers, Heat Exchangers and Pressure Vessels"; Part XI "Electrical Equipment"; Part XH "Refrigerating Plants"; Part XHI "Materials"; Part XIV "Welding"; Part XV "Automation"; Part XVI "Hull Structure and Strength of Glass-Reinforced Plastic Ships and Boats"; Part XVII "Distinguishing Marks and Descriptive Notations in the Class Notation Specifying Structural and Operational Particulars of Ships"; Part XVUI "Common Structural Rules for Bulk Carriers and Oil Tankers". The text of the Part is identical to that of the IACS Common Structural Rules; Part XIX "Additional Requirements for Structures of Container Ships and Ships, Dedicated Primarily to Carry their Load in Containers". The text of the Part is identical to IACS UR SUA "Longitudinal Strength Standard for Container Ships" (June 2015) and S34 "Functional Requirements on Load Cases for Strength Assessment of Container Ships by Finite Element Analysis" (May 2015).
    [Show full text]
  • Apprenticeship Curriculum Standard Industrial Mechanic (Millwright)
    Apprenticeship Curriculum Standard Industrial Mechanic (Millwright) Trade Code: 433 A Construction Millwright Trade Code: 426A Level 1 Common Core Date: 2005 Please Note: Apprenticeship Training and Curriculum Standards were developed by the Ministry of Training, Colleges and Universities (MTCU). As of April 8th, 2013, the Ontario College of Trades (College) has become responsible for the development and maintenance of these standards. The College is carrying over existing standards without any changes. However, because the Apprenticeship Training and Curriculum Standards documents were developed under either the Trades Qualification and Apprenticeship Act (TQAA) or the Apprenticeship and Certification Act, 1998 (ACA), the definitions contained in these documents may no longer be accurate and may not be reflective of the Ontario College of Trades and Apprenticeship Act, 2009 (OCTAA) as the new trades legislation in the province. The College will update these definitions in the future. Meanwhile, please refer to the College’s website (http://www.collegeoftrades.ca) for the most accurate and up-to-date information about the College. For information on OCTAA and its regulations, please visit: http://www.collegeoftrades.ca/about/legislation-and-regulations Ontario College of Trades © Level 1 - Industrial Mechanic (Millwright)/Construction Millwright TABLE OF CONTENTS Introduction...................................................................................................... 1 Summary of Total Program In-School Training Hours ................................
    [Show full text]
  • Quick Guide to Precision Measuring Instruments
    E4329 Quick Guide to Precision Measuring Instruments Coordinate Measuring Machines Vision Measuring Systems Form Measurement Optical Measuring Sensor Systems Test Equipment and Seismometers Digital Scale and DRO Systems Small Tool Instruments and Data Management Quick Guide to Precision Measuring Instruments Quick Guide to Precision Measuring Instruments 2 CONTENTS Meaning of Symbols 4 Conformance to CE Marking 5 Micrometers 6 Micrometer Heads 10 Internal Micrometers 14 Calipers 16 Height Gages 18 Dial Indicators/Dial Test Indicators 20 Gauge Blocks 24 Laser Scan Micrometers and Laser Indicators 26 Linear Gages 28 Linear Scales 30 Profile Projectors 32 Microscopes 34 Vision Measuring Machines 36 Surftest (Surface Roughness Testers) 38 Contracer (Contour Measuring Instruments) 40 Roundtest (Roundness Measuring Instruments) 42 Hardness Testing Machines 44 Vibration Measuring Instruments 46 Seismic Observation Equipment 48 Coordinate Measuring Machines 50 3 Quick Guide to Precision Measuring Instruments Quick Guide to Precision Measuring Instruments Meaning of Symbols ABSOLUTE Linear Encoder Mitutoyo's technology has realized the absolute position method (absolute method). With this method, you do not have to reset the system to zero after turning it off and then turning it on. The position information recorded on the scale is read every time. The following three types of absolute encoders are available: electrostatic capacitance model, electromagnetic induction model and model combining the electrostatic capacitance and optical methods. These encoders are widely used in a variety of measuring instruments as the length measuring system that can generate highly reliable measurement data. Advantages: 1. No count error occurs even if you move the slider or spindle extremely rapidly. 2. You do not have to reset the system to zero when turning on the system after turning it off*1.
    [Show full text]
  • Annual Report of the Director Bureau of Standards to the Secretary of Commerce for the Fiscal Year Ended June 30, 1920
    . ANNUAL REPORT DIRECTOR BUREAU OF STANDARDS SECRETARY OF COMMERCE : " ' .'-..} : . -» . ^^^™ FOR THE FISCAL YEAR ENDED JUNE 30, 1920 (Miscellaneous Publications—No. 44) WASHINGTON GOVERNMENT PRINTING OFFICE ANNUAL REPORT OF THE DIRECTOR BUREAU OF STANDARDS TO THE SECRETARY OF COMMERCE FOR THE FISCAL YEAR ENDED JUNE 30, 1920 (Miscellaneous Publications—No. 44) WASHINGTON GOVERNMENT PRINTING OFFICE 1920 Persons on a regular mailing list of the Department of Commerce should give prompt notice to the " Division of Publications, Department of Commerce, Washington, D. C," of any change of address, stating specificially the form of address in which the publication has previously been received, as well as the new address. The Department should also be advised promptly when a publi- cation is no longer desired. CONTENTS. Page. Chart showing functions of Bureau facing— 17 T. Functions, organization, and location 17 1. Definition of standards 17 Standards of measurement IS Physical constants (standard values) 18 Standards of quality 19 Standards of performance 19 Standards of practice 20 2. Relation of the Bureau's work to the public 20 Comparison of standards of scientific and educational in- stitutions or the public with those of the Bureau 20 Work of the Bureau in an advisory capacity 21 3. Relation of the Bureau's work to the industries 21 Assistance in establishing exact standards of measure- ment needed in industries 21 The collection of fundamental data for the industries 22 Training of experts in various industrial fields 22 4. Relation of the Bureau's work to the Government 2:! Comparison of standards of other Government depart- ments with those of the Bureau 2:'» Performance of tests and investigations and the collec- tion of scientific data of a fundamental nature 23 Advisory consulting capacity and : 24 The Bureau as a testing laboratory and its work in the preparation of specifications on which to base the pur- chase of materials 24 5.
    [Show full text]
  • Precision Quality Innovation
    Precision Quality Innovation Catalogue 32E starrett.co.uk After more than 130 years, we remain as dedicated today to the making of great tools for our customers as we were when L.S. Starrett founded the company in 1880. He created a business and a brand that has become synonymous with precision, quality and innovation, backed by unmatched service and support. We accomplish this by offering application- designed precision tools, saws, and custom solutions that optimise job and process “ I have believed that I could performance. Our confidence hinges on do no greater good than help create a business that would 130 years of experience focusing on your give people employment and needs and your success. We take great a chance to earn an honest pride in manufacturing long-lasting, easy-to- living” – L.S.Starrett use tools that provide consistent and reliable performance. Today, Starrett offers five product categories: Precision Measurement Tools, Metrology Equipment, Granite-based Engineered Solutions, Saw Blades, and Jobsite and Shop Tools. Whether you need to modify a standard tool, require assistance in selecting the best saw blade for your cutting application or desire a custom solution for your business, we have the breadth of knowledge to assist you. We are committed to providing you with complete solutions created for your exact needs. Problem solving is part of what we do every day. If the right tool for your application does not exist, contact us – we would appreciate the opportunity to build it. President and CEO Precision, Quality, Innovation Table of Contents Micrometers . 1 Surface & Hardness Testers .
    [Show full text]
  • E-1 Small Tool Instruments and Data Management Gauge Blocks Height
    Small Tool Instruments and E Data Management INDEX Gauge Blocks Features E-2 Gauge Blocks Accuracies E-4 Metric Rectangular Gauge Block Sets E-6 Inch Rectangular Gauge Block Sets E-11 Micrometer Inspection Gauge Block Sets E-12 Caliper Inspection Gauge Block Sets E-13 Individual Metric Rectangular Gauge Blocks E-14 Individual Inch Rectangular Gauge Blocks E-16 Height Master Rectangular Gauge Blocks with CTE E-17 ZERO CERA BLOCKS E-17 Rectangular Gauge Block Accessories E-18 Metric Square Gauge Block Sets E-20 Inch Square Gauge Block Sets E-21 Individual Metric Square Gauge Blocks E-22 Reference Gages Individual Inch Square Gauge Blocks E-23 Square Gauge Block Accessories E-24 Ceraston E-26 Maintenance Kit for Gauge Blocks E-26 Step Master E-27 Custom-made Blocks & Gages E-27 Gauge Block Interferometer GBI E-28 Granite Surface Gauge Block Comparator GBCD-100A E-28 Plates & Bench Gauge Block Comparator GBCD-250 E-29 Gauge Block Comparator GBCS-250 E-29 Comparator Height Master Height Master E-30 Digital Height Master E-30 CERA Height Master E-31 Auxiliary Block Kit E-31 Riser Blocks E-31 Universal Height Master E-32 Check Master E-33 Reference Gages Standard Scales E-34 Working Standard Scales E-34 CERA Straight Master E-35 Snap Gage Checker E-36 High Precision Square E-36 CERA/Steel Combination Square Master E-37 Gauge Block Sets Precision Square E-38 Precision Dial Square E-38 Combination Square Set E-39 E Steel Rules E-40 Thickness Gages E-41 Radius Gages E-42 Thread Pitch Gages E-42 E Digital Universal Protractor E-43 Universal Bevel
    [Show full text]
  • PRECISION ENGINEERING TOOLS WE HAVE WHAT IT TAKES to EXCEED & EXCEL the Plant
    PRECISION ENGINEERING TOOLS WE HAVE WHAT IT TAKES TO EXCEED & EXCEL The plant. The people. The passion 500,000 sq ft manufacturing | integrated research & development | advanced cnc machining | quality assurance Groz has always exceeded the expectations of tool manufacturers and users the world over. Groz carefully makes each tool under stringent quality control processes that are achieved in a hi-tech manufacturing environment in a 500,000 square foot plant. If you demand quality, trust Groz. ADDITIONS 07 08 Straight Straight & Edge Knife Edges Squares Dear Valued Customer, It is my pleasure to present to you the new catalogue that covers our 13 17 range of Precision Engineering Multi-Use Magnetic Tools. Rule and Compass Gauge We have covered fair ground over the last few years and with our state-of-the art production facility, we can now do much more 22 31 than before. You will see many Electronic Adjustable technologically superior products Edge Finders Vee Block Set as well as modifications to some of the earlier designs, in the following pages. Further, I assure you of the same top performance to which you are accustomed to from Groz. 31 35 Ball Bearing Pot We appreciate your business and Vee Block & Magnets value your loyalty & trust. Clamp Sets Warm Regards, 37 38 Sine Bars Sine Plates ANIL BAMMI Managing Director 46 49 Tweezersezers Tap Wrenchesnches - Prefessionalnal 68 7777 Rotaryry RRapidap Headd AActionct Millingng DDrillri Pressressess VicesVices Machinehine VicesVi CA02 PRECISION ENGINEERING TOOLS 1 Measuring and Marking
    [Show full text]
  • FOR IMMEDIATE RELEASE CONTACT: Tel: Chuck Bates, Dgs
    FOR IMMEDIATE RELEASE CONTACT: Chuck Bates, dgs Tel: 317.813.2230 MSC Industrial Direct Co., Inc. Offers SPI® Precision Measurement Products Melville, New York, January 27, 2011 – With precision, quality, and value in mind, MSC Industrial Direct Co., Inc., the country's leading supplier of cost down metalworking solutions, presents the SPI brand of precision measurement products. The SPI, Swiss Precision Instruments ®, product line spans over 7,000 of the most popular measuring tools and accessories, and more than 1,000 of the companyʼs tools and gauges are calibration certified traceable to NIST or NPL. For the past 50 years, SPI has continuously researched and developed high-quality measurement products to exacting standards. Nowhere else is this more evident than in the companyʼs free Certified Right Out Of The Box™ calibration certification that ensures customers of a productʼs accuracy. The expansive SPI product line covers calipers, gauges, indicators and holders, layout tools, micrometers, optical inspection equipment, setup accessories, and test equipment. Certified Right Out Of The Box products include models of dial indicators, micrometers, vernier calipers, dial calipers, electronic calipers, and gauge block sets. Certified Right Out Of The Box dial indicator products encompass standard, deluxe, and electronic versions. Micrometers within the certified line are outside micrometers (both digital and electronic), indicating micrometers, ball anvil type, depth gauge micrometers (both standard and electronic), internal bore gauge models, groove micrometers, and many more. Within the caliper family of Certified Right Out Of The Box SPI products are various models of vernier, dial, and electronic caliper types for performing extremely accurate I.D., O.D., step, and depth measuring.
    [Show full text]
  • Gauge Blocks an Inspection Certificate Is Supplied As Standard
    Gauge Blocks An inspection certificate is supplied as standard. Refer to page E-4 for details. Length Standards Brought to You by Mitutoyo Micrometer Inspection Gauge Block Sets SERIES 516 • Dedicated gauge block sets for micrometer inspection. Sets 516-106/7/8 and 516-322/3 are recommended for checking instrumental errors in micrometers due to the choice of block sizes ensuring that the instrument is checked through a full rotation of the spindle over the range 0-25 mm (or 0-1 inch). Sets 516-115/6/7, 516-165/6 and 516-177 contain blocks in 25 mm (or 1 inch) steps for aiding inspection of large micrometers in conjunction with one of the abovementioned sets. Sets 516-580/1/2, 516-390/1/2 are dedicated to the QuantuMike with its 2 mm/rev spindle feed. Steel CERA Steel 10-block set Steel 10-block set CERA 10-block set CERA 10-block set Steel 8-block set Steel 10-block set CERA 8-block set CERA 10-block set E Gauge Block Sets for Micrometer Inspection A set consisting of a Micro Checker and gauge blocks for micrometer inspection. (516-132/3/4/5/6/7) • Micro Checker Usage example Can clamp a stack of gauge SPECIFICATIONS blocks to be used for micrometer Metric Micro Checker (holder only) inspection. Order No. 516-607 Applicable gauge 516-106/107/108, block sets 516-156/157/158 Applicable gauge 2.5, 5.1, 7.7, 10.3, 12.9, 15, 17.6, block sizes (mm) 20.2, 22.8, 25 Inch Micro Checker (holder only) Order No.
    [Show full text]
  • Jkhan Noblesse
    Welcome to Huma-Air. We design and manufacture brand- and model specific precision regulators for PCP air rifles. By using only the highest quality materials such as aircraft grade aluminum, aluminum- bronze, chrome-moly steel and precision belleville springs, our ultra-compact regulators are high performing with less than 1% fluctuation. Regulator installation guide Jkhan Noblesse For adjustment tips, frequently asked questions and a complete list of installation manuals and instructions on how to adjust your Huma-Air regulator https:/www.huma-air.com/Fitting-instructions Or go there directly by scanning the QR code Before you you start, realize this; Working on a high pressure rifle could potentially be harmful or lethal to you or bystanders if you do not know what you are doing. The pictures of the rifleparts in this manual are universal and mend as an example to explain the working principle. They might not be equal to the parts in your rifle. Do not attempt to install this regulator yourself if you do not have a clear understanding of how these pcp rifles and regulators work. Do not attempt to install this regulator if you are not skilled to work on an airrifle; contact your local gunsmith to do the fitting. Installation and operation is done completely at your own risk. Installing this regulator might void your rifle’s factory warranty. Your rifle may never be filled higher in pressure as stated in your rifle’s manual. Do not attempt to fit this regulator in another rifle as mentioned in our order conformation. These regulators are not suitable to use as a CO2 to HPA conversion, this could potentially be harmful or lethal to you or bystanders.
    [Show full text]