Daikin Roofpak Applied System With

Total Page:16

File Type:pdf, Size:1020Kb

Daikin Roofpak Applied System With Catalog 220-1 RoofPak® Applied Rooftop Systems with Energy Recovery Wheels Packaged Heating and Cooling Units Type RFS/RPS – 15 to 75 Tons Type RDT – 45 to 75 Tons Rooftop Air Handlers Type RAH/RDS – 4,000 to 30,000 CFM MEA 368-93-N TABLE OF CONTENTS TABLE OF CONTENTS Introduction . 3 Physical Data . 18 Daikin Energy Recovery Systems................3 Cooling Capacity Data . 20 Factory-Installed and Tested Package ............3 Heating Capacity Data . 28 Roofpak Energy Recovery Systems . 4 Gas Heat ..................................28 Energy Savings ..............................4 Electric Heat . .30 Satisfies ASHRAE 90.1-2004 Energy Recovery Steam and Hot Water Heat ...................31 Requirements . .4 Component Pressure Drops . 32 A Complete, Factory-Tested Package.............4 Energy Recovery Module Air Pressure Drop Enthalpy Wheel Design........................4 Fan Loss ..................................32 Return/Exhaust Air Fan ........................5 Fan Performance Data . 35 Handling Moisture ............................5 Supply Fans ...............................35 Summer Performance .........................5 Airfoil Return Fans . 40 First Cost and Operating Cost Reductions .........6 Dimensional Data . 41 Two Arrangements Offered .....................6 Section Options and Locations . 41 Parallel Air Paths on Energy Recovery Wheel Electrical Knockout Locations ..................46 Applications.................................7 Drain and Air Connection Locations .............47 Enthalpy Wheel Controls and Wiring . .8 Piping Entrance Locations ....................48 Energy Recovery Bypass Damper Control .........8 Roof Curbs . 49 Application Considerations . 9 Recommended Clearances . 52 General ....................................9 Service Clearance...........................52 Unit Location ................................9 Overhead Clearance .........................52 Split Units ..................................9 Ventilation Clearance ........................52 Curb Installation .............................9 Electrical Data . 53 Acoustical Considerations.....................10 Supply Power Wiring.........................56 Ductwork ..................................11 Weight Data . 57 Filters . 11 Unit Weights . .57 Variable Air Volume Application.................12 Fan Motor Weights ..........................58 Fan Operating Range ........................12 Roof Curb Weights . 61 Altitude Adjustments .........................12 Engineering Guide Specification . 62 Condenser Performance ......................13 Wheel Performance .........................13 Furnace Performance . .13 Unit Selection . 14 DesignFlow, Hi-F, MicroTech, Protocol Selectability, RoofPak, SelectTools, SpeedTrol, SuperMod, UltraSeal, and VaneTrol are trademarks Daikin Applied Americas. Microsoft is a registered trademark of Microsoft Corporation. Windows is a trademark of Microsoft Corporation. © 2018 Daikin Applied. All rights reserved throughout the world. CAT 220-1 • ROOFPAK APPLIED ROOFTOPS 2 www.DaikinApplied.com INTRODUCTION INTRODUCTION Daikin Energy Recovery Systems Factory-Installed and Tested Our energy recovery device transfers both heat and moisture energy between the exhaust and ventilation air. In doing so, it Package conditions the incoming ventilation air. This total energy device Daikin energy recovery systems are provided as a one-piece, offers a cost-effective and efficient method for containing factory-installed and tested package. The package includes energy costs while meeting the ventilation requirements of an AHRI certified enthalpy wheel, exhaust fan with VFD, ASHRAE Standard 62.1-1999. prefilters, and, for economizer applications, optional bypass dampers and controls (see Figure 1). This helps to eliminate field coordination and leakage problems associated with field installation. The outdoor and exhaust air flows are arranged in counterflow for better efficiency, and to reduce field cleaning requirements. Exhaust contaminants cannot enter the ventilation air because the exhaust air static pressure is always less than the ventilation air static pressure. Frost protection and purge options are also available. Figure 1: Energy Recovery Module www.DaikinApplied.com 3 CAT 220-1 • ROOFPAK APPLIED ROOFTOPS ROOFPAK ENERGY RECOVERY SYSTEMS ROOFPAK ENERGY RECOVERY SYSTEMS Energy Savings Enthalpy Wheel Design Daikin energy wheels normally recover 70–75% both sensible The unique composition of the Daikin energy wheel (see and latent energy. The result can be considerable energy Figure 2) provides significant advantages. Composed savings: of synthetic fiber, it allows moisture-absorbing desiccant • They provide twice as much summer energy recovery to be uniformly and permanently dispersed throughout as sensible only alternatives such as plate frame heat the wheel, maximizing its life expectancy. The desiccant exchangers and run-around loops. forms a molecular sieve that attracts water and minimizes contamination. The honeycombed design and small aperture • Energy recovery increases the air conditioning capacity sizes of our wheel provide even air flow and minimize internal by 25% if minimum outdoor air design is 33%. Therefore, wheel bypass - unlike other energy recovery wheels that can a 75 ton unit with energy recovery provides about 90 separate or be spread apart by air flow and risk contamination tons of cooling capacity. The cost savings on mechanical of ventilation air from the exhaust air. Other benefits include: heating and cooling components offset the additional cost of energy recovery. • Homogenous media - not coated or bonded and will not delaminate • Winter humidification energy costs may be cut up to 60%. • Synthetic wheel media is completely corrosion resistant • Winter latent energy recovery lowers the dew point of exhaust air, compared to sensible only alternatives and • Unitary wheel construction maximizes face flatness allows frost-free operation to lower ambient temperatures. • Fluted geometry minimizes internal cross leakage • Molecular sieve desiccant reduces cross contamination Satisfies ASHRAE 90.1-2004 • Wheel is completely water washable Energy Recovery Requirements Cassette Design • ASHRAE 90.1-2004 usually requires energy recovery if • Heavy duty galvanized steel construction with removable the design requires more than 5000 total CFM and more side panels than 70% minimum outdoor air. • No-maintenance bearings standard on small cassettes • The Daikin energy recovery effectiveness exceeds ASHRAE 90.1-2004 requirements. • Flanged outboard bearings used on larger cassettes • Full contact brush seals minimize leakage A Complete, Factory-Tested • AC drive motor with Power Twist link belt Package • Optional variable speed drive motor available • Adjustable purge section, provided as standard, reduces Outdoor and Return Air Prefilters cross-contamination 2" pre-filters are provided in both the outdoor and return air, to Figure 2: Energy Wheel Construction minimize the need for cleaning the wheel. AHRI and UL Conformance The Daikin energy recovery wheel is AHRI certified for performance and UL recognized for safety. Integrated Cooling, Heating and Recovery Control Mechanical heating and cooling are supplied as necessary to supplement the wheel and maintain space conditions. Free Cooling Units with economizers include bypass dampers that are opened when “free cooling” is available. The wheel is simultaneously turned OFF. Proper Exhaust Exhaust fan speed is controlled for proper exhaust, using a factory installed Variable Frequency Drive (VFD) and space building pressure sensor. CAT 220-1 • ROOFPAK APPLIED ROOFTOPS 4 www.DaikinApplied.com ROOFPAK ENERGY RECOVERY SYSTEMS Figure 3: Adjustable Purge Return/Exhaust Air Fan Outside Air at A return/exhaust air fan is provided in a typical exhaust fan Atmospheric Pressure Supply Air configuration. This allows the exhaust to be at a lower pressure than the OA intake and minimizes cross-contamination. Any leakage must occur However, this fan has characteristics of both a return air fan from outside to Exhaust Air Adjustable Purge (RAF) and an exhaust air fan (EAF). due to pressure gradient (See Detail) • EAF characteristic - It only exhausts air and must be sized to handle return duct APD at maximum exhaust Exhaust Air cfm. • RAF characteristic - It always operates whenever the SAF operates and the SAF does not need to be sized for the return duct APD. Plenum Fan • RAF characteristic - The fan will do an excellent job of draws a negative pressure NOTE: Maintain the pressure gradient to preventing positive building pressure because it draws a prevent cross contamination from the large negative at the return of the unit. Exhaust to Outside Supply Air The EAF/RAF must be controlled by building pressure. This control is included with the MicroTech® II controls option. Figure 4: Purge Detail Adjust purge in this Handling Moisture direction to decrease OUTSIDE AIR capacity and increase Low space humidity is a common problem in the winter and purge can cause both discomfort and health problems for tenants. It also leads to increased static electricity, which can be damaging to computer equipment. However, mechanical humidification requires 1,100 btu per pound of humidity. Our energy recovery system provides the added benefit of significantly raising the humidity level of outdoor air in the winter. Not only can this have EXHAUST AIR a dramatic impact on the first cost and operating cost of an HVAC system, it can also dramatically improve indoor air quality and
Recommended publications
  • CAT 633 Model WSC Centrifugal Water Cooled Chillers
    Catalog 633 Centrifugal Compressor Water Chillers Model WSC, B-vintage 300 to 1800 Tons (700 to 6330 kW) HFC-134a Refrigerant 60/50 Hz TABLE OF CONTENTS TABLE OF CONTENTS Introduction . 3 Features and Benefits . 4 Unit Layouts . 7 Options and Accessories . .8 Retrofit Disassembly (Knockdown Options) . 10 Electrical Data . 11 Application Considerations . 15 Specifications (WSC 079-126) . 22 Specifications (WSC 160) . 28 Limited Product Warranty . 35 Manufactured in an ISO 9001 & ISO 14001 certified facility * TSC and HSC models are outside the scope of AHRI certification program. ©2018 Daikin Applied. Illustrations and data cover the Daikin Applied product at the time of publication and we reserve the right to make changes in design and construction at any time without notice. CAT 633 • CENTRIFUGAL WATER CHILLERS 2 www.DaikinApplied.com INTRODUCTION INTRODUCTION Water-Cooled Chiller Products Magnitude® Magnetic Bearing Centrifugal Chiller WMC 86 - 400 Tons Heat Recovery options available WME Magnitude® Magnetic Bearing Centrifugal Chiller 400 - 1500 Tons WSC Single Centrifugal Compressor Chiller 300 - 1800 Tons WDC WCC Dual Centrifugal Compressor Chiller Series Counterflow Centrifugal Compressor Chiller 600 - 2500 Tons 1000 - 2700 Tons Navigator® Water-Cooled Screw Chiller WWV 120 - 300 Tons Templifier® Heat Recovery Water Heaters WGZ TG (Scroll Compressor) 15� - �255� tons �cooling 320� - �3410� MH �heating TMC (Centrifugal Compressor) 86� - �400� tons �cooling 1600-6800 � MH �heating Water-Cooled Scroll Chiller TSC (Centrifugal Compressor)
    [Show full text]
  • SCHOOL BOARD of BREVARD COUNTY, FLORIDA BOARD AGENDA ITEM – August 27, 2019 PURCHASING SOLICITATION PB # 16-PB-008-LU: Daikin GSA Pricing
    SCHOOL BOARD OF BREVARD COUNTY, FLORIDA BOARD AGENDA ITEM – August 27, 2019 PURCHASING SOLICITATION PB # 16-PB-008-LU: Daikin GSA Pricing ☐ (ITB) Invitation To Bid ☐ (ITN) Invitation To Negotiate ☒ (PB) Piggyback ☐ (RFP) Request For Proposal ☐ (RFQ) Request For Qualifications ☐ (SC) State Contract ☐ (SS) Sole Source REQUESTOR: Plant Operations & Maintenance Legal Review: ☐ Yes ☒ No VENDOR NAME AMOUNT AWARDED REQUIRED PRODUCTS/SERVICES Daikin Applied Americas Inc. Variable Refrigeration, Air-Conditioning, and Air-Circulating Equipment and Services Total Variable ☒ Contract Renewal New Contract Amount Variable ☐ Recurring Contract Previous Contract Amount Variable ☐ New Contract Variance N/A PRICE INCREASE / DECREASE EXPLANATION: N/A DISCUSSION: The School Board of Brevard County currently has installed Daikin HVAC equipment. Daikin Applied Americans Inc. is the only authorized service and repair provider allowed to work on their proprietary equipment. Pricing is based on GSA Schedule 84, Contract No. GS-07F-0377V: Refrigeration, Air- Conditioning and Air-Circulating Equipment. State Board of Education Rule 6A-1.012(6) allows school districts to make purchases at or below the specified prices from contracts awarded by other city or county governmental agencies, other district school boards, community colleges, federal agencies, the public or governmental agencies of any state, or from state university system cooperative bid agreements, when the proposer awarded a contract by another entity will permit purchases by a district school board at the same terms, conditions, and prices (or below such prices) awarded in such contract, and such purchases are to the economic advantage of the district school board. CONTRACT TERM: The initial contract term commenced July 22, 2015 and will continue until June 21, 2024.
    [Show full text]
  • HVAC Equipment, Controls and Service
    HVAC Equipment, Controls and Service Effective November 1, 2019 through October 31, 2022 Products and Services Available Contracted Suppliers This category includes chillers, air handlers, condensing units, roof top New Expiring units, generator sets, control systems, rental equipment (disaster Supplier Contract Contract preparedness), maintenance and services (such as design, installation, repair, restoration and modernization) necessary to provide proper comfort, PP-FA-773 New air quality, ventilation and room air distribution throughout your facility. How to Operationalize These Agreements PP-FA-774 PP-FA-613 • A Participating Member Designation Form (PMDF) or electronic price activation (PA) is required at Tier 2 or higher with Armstrong, PP-FA-775 PP-FA-512 Daikin and Lennox. • A PMDF/PA is required at all tiers with Carrier and Trane. PP-FA-776 New • When ordering, reference the Premier agreement and your facility’s entity code. PP-FA-777 PP-FA-513 Aggregation Opportunities Aggregation is allowed for multi-facility systems, group purchasing ASCEND®: There is no ASCEND award in this organizations and established networks of facilities with all suppliers. category. Class of Trade • Agreements with Armstrong, Daikin and Lennox are available to acute care, non-acute healthcare and non-healthcare facilities. • Agreements with Carrier and Trane are available to healthcare facilities, including academic health systems. Other Key Value and Terms • Pricing and product price multipliers are firm for the term of the agreement with all suppliers. • Financial analysis reveals: • Carrier’s new agreement pricing is flat compared to its expiring agreement pricing. • Daikin’s new agreement pricing offers up to a 1.3 percent savings compared to its expiring agreement pricing.
    [Show full text]
  • IOM 1264-2 Navigator WWV Water-Cooled Chillers
    Installation, Operation, IOM 1264-2 and Maintenance Manual Group: Chiller Part Number: IOM1264-2 Date: August 2020 Navigator® Water-cooled Screw Chillers Model WWV 120 to 300 Tons (527 to 1055 kW) HFC-134a Refrigerant 50/60 Hz Table of Contents Table of Contents Introduction . 5 Installation and Application Considerations . 7 Installation - Knockdown . 16 Dimensional Drawings . 20 Controller Operation . 21 Unit Functions . 27 Circuit Functions . 33 Alarms and Events . 37 Using the Controller . 49 Startup and Shutdown . 50 System Maintenance . 51 Manufactured in an ISO 9001 & ISO 14001 certified facility ©2020 Daikin Applied. Illustrations and data cover the Daikin Applied product at the time of publication and we reserve the right to make changes in design and construction at any time without notice. IOM 1264-2 • NAVIGATOR® MODEL WWV CHILLERS 2 www.DaikinApplied.com Pre-Start Checklist – Screw Chillers Must be completed, signed and provided to Daikin Applied at least 2 weeks prior to requested start date. Job Name Installation Location Customer Order Number Model Number(s) G.O. Number(s) Chilled Water and Condenser Water for Water-cooled Chiller Yes No N/A Initials Piping complete Water strainer(s) installed in piping per manual requirements Water System – flushed, filled, and vented; Water treatment in place Cooling tower flushed, filled, vented; Water treatment in place (if applicable) Pumps installed and operational (rotation checked, strainers installed and cleaned) Controls operational (3-way valves, face/bypass dampers, bypass valves,
    [Show full text]
  • Installation, Operation, and Maintenance Manual Navigator® Water-Cooled Screw Chillers IOM 1264
    Installation, Operation, IOM 1264 and Maintenance Manual Group: Chiller Part Number: IOM1264 Date: December 2017 Navigator® Water-cooled Screw Chillers Model WWV 120 to 300 Tons (527 to 1055 kW) HFC-134a Refrigerant 60 Hz TABLE OF CONTENTS TABLE OF CONTENTS Introduction . 3 Installation and Application Considerations . 5 Dimensional Drawings . 12 Controller Operation . 13 Unit Functions . 19 Circuit Functions . 25 Alarms and Events . 29 Using the Controller . 38 Startup and Shutdown . 40 System Maintenance . 42 Manufactured in an ISO 9001 & ISO 14001 certified facility ©2017 Daikin Applied. Illustrations and data cover the Daikin Applied product at the time of publication and we reserve the right to make changes in design and construction at any time without notice. IOM 1264 • NAVIGATOR® MODEL WWV CHILLERS 2 www.DaikinApplied.com Pre-Start Checklist – Screw Chillers Must be completed, signed and provided to Daikin Applied at least 2 weeks prior to requested start date. Job Name Installation Location Customer Order Number Model Number(s) G.O. Number(s) Chilled Water Yes No N/A Initials Piping Complete Water strainer installed on evaporator, 0.125” (3.2mm) or smaller perforations Water System filled, flushed and vented Pumps installed and operational (rotation checked, strainers cleaned) Controls operational (3-way valves, face/bypass dampers, bypass valves, etc.) Water system operated and tested; flow meets unit design requirements Flow switch installed and wired Vent installed on evaporator Glycol at design % Electrical Yes No N/A Initials Building controls operational *Power leads connected to power block or optional disconnect Power leads have been checked for proper phasing and voltage All interlock wiring complete and compliant with Daikin specifications Power applied at least 24 hours before startup Oil heaters energized at least 24 hours before startup Chiller components (EXV Sensors Transducers) installed and wired properly.
    [Show full text]
  • Mergers, Acquisitions, Name Changes
    164 AIR CONDITIONING, HEATING & REFRIGERATION NEWS Mergers, Acquisitions, Name Changes Looking for a manufacturing company that doesn’t seem to be listed in this 2017 Directory Issue? If you can’t find it in the Manufacturers Alphabetic Listings, then one of several things may have happened. The company could have dropped out of the hvacr industry — ceased to operate altogether, or just stopped making hvacr products; or the company may have changed owners and it is now a part of another corpo- rate identity. In either case, this listing may help. Following are the names of hundreds of manufacturers and their brand names that were found in previous editions of the Directory Issue. Many of these companies continue to exist, but are now known under dif- ferent names. To find the new identity, just look up the old name in this alphabetic listing. If no informa- tion is available, we simply provide the last year the company was listed in the Directory Issue. This listing represents our best efforts at tracking the manufacturer-members of the hvacr community. If we have erred or provided incomplete information, we apologize and hope that you will set us straight. Contact The News Editorial Department at P.O. Box 2600, Troy, Mich. 48007. Watsco would acquire ACR’s outstanding common stock A in a cash tender offer. AAF International, Louisville, Ky. Adams Manufacturing Co., Cleveland In 2006, Daikin obtained AAF as part of its acquisition Acquired assets and rights to G1 and G2 power gas of the OYL Group. In 2016, AAF acquired Flanders burners from R.W.
    [Show full text]
  • MWSU Chiller #3 Proposed by Daikin Applied Page 1 August 9, 2017 Presented To
    MWSU Chiller #3 National IPA/TCPN Proposal: Missouri Western State University 4525 Downs Drive St Joseph, MO 64507 Project Location: Missouri Western State University 4525 Downs Drive St Joseph, MO 64507 Project Title: MWSU Chiller #3 Proposal Number: R150505-MO-15317 Proposal Date: August 9, 2017 Presented to: Jerry P. Gentry Director of Physical Plant Email: [email protected] O: 816.271.4417 C: 816.244.3675 Presented by: Duane Rothstein Kevyn Gordon National IPA/TCPN Account Manager Sales Representative Daikin Applied Thermal Mechanics, Inc. Email: [email protected] Email: [email protected] C: 952.261.9313 C: 816.694.7899 F: 763.383.4584 O: 816.298.6281 Proposed by Daikin Applied Page 1 August 9, 2017 MWSU Chiller #3 Table of Contents Table of Contents................................................................................................................... 2 Introducing Daikin Applied ...................................................................................................... 3 Key Team Members ............................................................................................................... 4 Prime Contractor – Daikin Applied....................................................................................... 4 Scope .................................................................................................................................... 5 National IPA/TCPN Price Breakdown .....................................................................................
    [Show full text]
  • Gsa Gs-07F-0377V
    Authorized Federal Supply Schedule Price List General Services Administration - Federal Supply Service Schedule Number 84: Total Solutions for Law Enforcement, Security, Facilities Management, Fire, Rescue, Clothing, Marine Craft and Emergency/Disaster Response Business Size: Large FSC Group: 41 - Refrigeration, Air-Conditioning and Air-Circulating Equipment FSC Class/Product Code/Service Code: 4110, 4120, 4130, 4140, NO63, R414 Contractor Information: Daikin Applied Americas Inc. dba Daikin Applied. 13600 Industrial Park Blvd. Minneapolis, MN 55441-3743 Phone: 800-432-1342 Website: www.daikinapplied.com Contract Administration: Robert Preston Email: [email protected] Phone: 540-680-0749 Contract No: GS-07F-0377V Contract Period: June 22, 2014 to June 21, 2024 Contract Modification(s): P0-0172 dated October 07, 2019 On-line access to contract ordering information, terms and conditions, up-to-date pricing, and the option to create an electronic delivery order are available through GSA Advantage!, a menu-driven database system. The Internet address for GSA Advantage is: http://gsaadvantage.gov. For more information on ordering from Federal Supply Schedules, visit http://www.fss.gsa.gov GS-07F0377V (October 2019) Table of Contents Customer Information ................................................................................................................................................................................ 3 Daikin Representative Listing ...................................................................................................................................................................
    [Show full text]
  • Installation, Operation, and Maintenance Manual Magnitude® Magnetic Bearing Centrifugal Chillers IOM 1210-7
    Installation, Operation, IOM 1210-7 and Maintenance Manual Group: Chiller Part Number: IOM1210-7 Date: June 2018 Magnitude® Supercedes: April 2018 Magnetic Bearing Centrifugal Chillers Model WMC-D, Model TMC 125 to 400 Tons (440 to 1400 kW) HFC-134a Refrigerant 50/60 Hz TABLE OF CONTENTS TABLE OF CONTENTS Introduction . 3 Installation . 6 Operation . 28 Maintenance . 63 Appendix . 65 Manufactured in an ISO 9001 & ISO 14001 certified facility ©2018 Daikin Applied. Illustrations and data cover the Daikin Applied product at the time of publication and we reserve the right to make changes in design and construction at any time without notice. IOM 1210-7 • MAGNITUDE® MODEL WMC CHILLERS 2 www.DaikinApplied.com Pre-Start Checklist – Centrifugal Chillers Must be completed, signed and returned to Daikin Applied service dept. at least 2 weeks prior to requested start date. Job Name Installation Location Customer Order Number Model Number(s) G.O. Number(s) Chilled Water Yes No N/A Initials Piping Complete Water System – flushed, filled, vented; Water treatment in place Pumps installed and operational (rotation checked, strainers installed and cleaned) Controls operational (3-way valves, face/bypass dampers, bypass valves, etc.) Water system operated and tested; flow meets unit design requirements Condenser Water Yes No N/A Initials Cooling tower flushed, filled, vented; Water treatment in place Pumps installed and operational (rotation checked, strainers installed and cleaned) Controls (3-way valves, bypass valves, etc.) operable per IM/IOM Water system operated and flow balance to meet unit design requirements Electrical Yes No N/A Initials 115 volt service completed, but not connected to control panel (remote mounted starters) Line Power Leads connected to starter; load leads(b) run from starter to compressor, ready for connection by Service (Do not connect load leads to starter or compressor terminals).
    [Show full text]
  • Air-Cooled Scroll Compressor Water Chillers
    Installation, Operation and Maintenance Manual IOMM 1155-1 Group: Chiller Part Number: 331975001 Effective: July 2016 Supersedes: March 2012 Air-Cooled Scroll Compressor Water Chillers AGZ 010BS – AGZ 034BS, Packaged Chiller AGZ 010BM – AGZ 034BM, Remote Evaporator 10 to 34 Tons, 35 to 120 kW R-407C 60 Hertz Software Version AGZSU0102D Table of Contents Lubrication.............................................. 31 Introduction........................................3 Electrical Terminals ................................ 31 General Description...................................3 Condensers.............................................. 31 Inspection ..................................................3 Refrigerant Sight glass............................ 31 Installation.................................................3 Handling ....................................................3 Standard MicroTech II Controller.32 Location.....................................................4 Table of Contents.................................... 32 Service Access...........................................4 Overview................................................. 33 Vibration Isolators .....................................5 General Description ................................ 33 Chilled Water System ................................9 Setpoint Security..................................... 37 Water Connections...................................11 Equipment Protection Alarms................. 37 Refrigerant Charge ..................................11 Control Functions
    [Show full text]
  • IOM 1274-2 Installation, Operation, and Maintenance Manual
    Installation, Operation, IOM 1274-2 and Maintenance Manual Group: Chiller Part Number: IOM1274-2 Date: September 2020 Centrifugal Chillers Model WSC, HSC, TSC - B Vintage 300 to 1800 Tons (1050 to 6330 kW) HFC-134a Refrigerant 60/50 Hz Table of Contents Table of Contents Introduction . 5 Use with On-Site Generators ..................19 General Description . 6 Long Term Storage . 23 Installation . 7 Retrofit Knockdown .........................24 Receiving and Handling .......................7 Operation . 35 Location....................................8 Dual/Multi-Chiller Operation . .35 Operating Limits .............................9 Operator Responsibilities .....................36 Field Insulation ..............................9 Unit Enabling/Disabling .......................36 Water Piping . 9 Human Machine Interface (HMI) ................37 Condenser Water Control .....................11 Alarms ....................................58 Heat Recovery Chillers . 12 Controller Inputs and Outputs ..................62 Relief Valves ...............................12 Unit Startup and Maintenance . 64 Oil Coolers . 14 Pre-Startup ................................64 Field Wiring ................................17 Routine Maintenance ........................64 Building Automation Systems (BAS) ............19 Manufactured in an ISO 9001 & ISO 14001 certified facility Models TSC and HSC are outside of the AHRI certification program and not optionally certified. ©2020 Daikin Applied. Illustrations and data cover the Daikin Applied product at the time
    [Show full text]
  • News Release
    News Release Daikin Innovations Advance Air Intelligence™ at AHR EXPO 2019 Industry-leading products in booth demonstrate Daikin’s commitment to maintaining its status as the world’s leading HVAC manufacturer ATLANTA— January 14, 2019 –– Revolutionary products and experiences are at the center of Daikin’s presence at this year’s AHR Expo. The Daikin booth will highlight new, advanced residential and commercial HVAC equipment for providing superior air to end-users. Daikin’s Innovation Roadshow trailer also made the trip to Atlanta, and is featured as an interactive demonstration of Daikin’s industry-leading commercial HVAC solutions, for show attendees to experience Daikin’s advanced technology first-hand. “Daikin is invested in the next generation of HVAC technology by continuously creating innovative solutions for improving building efficiency,” said Mike Schwartz, CEO of Daikin Applied Americas. “With the Innovation Roadshow trailer, we are able to give visitors a unique and immersive experience with the latest Daikin technology. Customers can dive into the products and fully experience how buildings of all sizes can benefit.” Debut of new Daikin One™ Ecosystem With the introduction of the Daikin One ecosystem, Daikin is up-ending the status quo in the HVAC market, where players have been conservative in adopting IoT technologies and, until recently, relegated leadership in the smart thermostat category to consumer electronics brands. At the heart of the new Daikin One ecosystem is the new Daikin One+™ smart thermostat, engineered to communicate seamlessly with all Daikin One ecosystem components, including the new Daikin Fit™ condensing units, Daikin One air cleaners, and communicating furnaces and evaporator coils.
    [Show full text]