integratedelectrophoresissystems

vertical horizontal dryblot tankblot

-biosciences-integratedelectrophoresisandblottingsystems-

Insight™ Semi-Dry BlottingSystems

Quick&Efficient Quicktransfertimesmakethesesystems idealfortherapidand efficienttransfer ofnucleicacidsandproteinsfromagaroseoracrylamidegels.

Twosizestofityourneeds: Unit 91-1010-SD 91-2020-SD Transferarea(cm) 11x11 21x21 Buffervolume(ml) 50 200

Convenient&Versatile Solidplatestyleelectrodesassureevenpressureandcomplete moleculartransfer. Galileosemi-dryelectroblotterswillaccomodatemostpre-cast gels,andformanylargerformatpre-castgels,oncethestacking areaofthegelisremovedthe"working"areaofwillalsofiteasily intothedevices. Sinceonlythetranfer"sandwich"ofgel,membraneandblotting papersmustbekeptwet,muchlessbufferisrequiredthan traditionaltanktransfersystems. Safe&Reliable Interlockingsafetylidpreventsreverseorientationofelectricfiled. Highqualityplate electrodes(stainlesssteelcathodeandplatinumanode) andgoldplatedcomponentsassurelong,trouble-freeperformance. Systemissuppliedcompletewithpowerleadsandasamplepackofour ultra-purecottonfiberfilterpaper. -galileobiosciences-integratedelectrophoresisandblottingsystems-1-877-481-9175- GalileoInsight™ Semi-DryBlottingSystems

91-1010-SD InsightMiniSemiDryElectroblotter,11x11cmblottingarea Semi-Dry Blotting 91-2020-SD InsightMaxiSemiDryElectroblotter,21x21cmblottingarea Systems 91-KNB ReplacementKnobs,3/Set 91-RPC ReplacementPowerCords

unit 91-1010-SD 91-1010-SD systemdimensions(cm) 19Wx19L x6H 29Wx29L x6H transferarea(cm) 11x11 21x21 buffervolume approx50ml approx200ml recommendedvoltage <100V <100V 0.8-3mA percmofgel 0.8-3mA percmofgel recommendedcurrent surfacearea(constant) surfacearea(constant) runtime 30-60minutes 30-60minutes

full-extensionelectrodes

Provide maximum transferarea forgels

GalileoBioscience•1-877-481-9175•www.galileobioscience.com integratedelectrophoresissystems

vertical horizontal dryblot tankblot

-galileobiosciences-integratedelectrophoresisandblottingsystems-

Insight™ Tank BlottingSystems

HighPerformance TheGalileoInsight™ tankstyle electroblottersaredesignedtorapidly transferawiderangeofnucleicacids orproteinsfromacrylamidegelsto nitrocellulose,nylonorPVFDmembranes. Uptofourgelscanbetransferedsimultaneously. Twosizestofityourneeds: Unit 91-1010-TB 91-2020-TB Cassettesize(cm) 9x9 18x20 Cassettecapacity 4 2 Buffervolume(ml) 1300 4000

Efficient&Versatile Platinumgridstyleelectrodesprovideevenfieldstrenghtandassure evenandcompletemoleculartransfer. Color-codedcassettesforeasyandcorrentlyorientedassemblyof transfersandwichanderror-freetransfer. Systemsaccomodateuptofourgelcassettes. Largebuffercapacityandintegralcoolingpermitshighcurrentfor efficientandcompletetransfersofeven“hardtotranser”proteins.

Safe&Reliable Interlockingsafetylidpreventsreverseorientationofelectricfiled. Platinumgridstyleelectrodesand andgoldplatedcomponents assurealong,trouble-free,performancelife. Systemissuppliedcompletewithpowerleads, fourblottingcassetes andasamplepackofourultra-purecottonfiberfilterpaper. -galileobiosciences-integratedelectrophoresisandblottingsystems-1-877-481-9175- GalileoInsight™ TankBlottingSystems

91-1010-TB InsightMini TankBlotter(10x10cm)with4cassettes Tank Blotting 91-2020-TB InsightMaxi TankBlotter(20x20cm)with2cassettes Systems 91-1010-TBCS TransferCassettewithPads 91-1010-BPD ReplacementBlottingPads,4perpack 91-2020-TBCS TransferCassettewithPads 91-2020-BPD ReplacementBlottingPads,2perpack 91-KNB ReplacementKnobs,3/Set 91-RPC ReplacementPowerCords

unit 91-1010-TD 91-1010-TD systemdimensions(cm) 13Wx15L x15H transferarea(cm) 9x9 cassettecapacity 4 buffervolume 1300ml recommendedvoltage 0-150V runtime 4hours - overnite

color-codedcassetes

Foreasy, error-free transfers.

integratedbufferports

Forcool, efficient transfers.

GalileoBioscience•1-877-481-9175•www.galileobioscience.com