PROTECTION

Seibersdorf Labor GmbH · v13082015 © 2015 DOSIMETRY SERVICE RADIATION PROTECTION DOSIMETRY | DOSIMETRY SERVICE

Monte Carlo computer simulation model of the area dosemeter Seibersdorf

AREA AND ENVIRONMENTAL DOSEMETER PERFORMANCE CHARACTERISTICS SEIBERSDORF

The dosimetry service Seibersdorf is an accredited testing laborato- • measurement of external X-ray and gamma radiation in terms ry for ionising radiation and radiation protection providing area do- of ambient dose equivalent H*(10) semeters for workplace monitoring (TLD-1K-V4) and environmental • dose range 50 μSv to10 Sv with standard measurement peri- monitoring (TLD-2K-V4). ods of three months • optimized radiation energy range beyond 30 keV to 7 MeV for Our passive thermoluminescent dosemeters (TLDs) are routinely all angles of radiation incidence used for long-term surveillance of exposure limits according Austri- • inherent secondary equilibrium up to several MeV for an, European and International radiation protection safety standards. high energy radiation detection • high measurement accuracy by using TLD detector chips on a Dosemeter development and performance optimization are based on detector card protected by a -tight envelope foil Monte Carlo simulations and verification measurements (Radiation • robust construction with an inner casing and an Alumi- Measurements 43, 2008) and international standards (IEC 62387, nium protection cap DIN 25483). • optionally standing or hanging positioning on specified mea- surement sites The area dosemeter is trademarked as a registered Community de- • excellent performance results at the PTB intercomparisons sign (OHIM 371190 11/07/2005). 2005-2007 and 2011/2012 and the EURADOS intercomparison 2014

02 AREA DOSEMETER Registered Community Design

AREA DOSEMETER DESIGN . 2,1 2,0 The cylindrical area dosemeter Seibersdorf consists of a powder- 1,9 IEC upper limit 75°-90° 1,8 coated protection cap and an inner plastic casing with 1,7 IEC upper limit 0°-75° a central slit. Both parts can be combined and secured by a simple 1,6 1,5 0° cable tie or an official seal. Main items of the area dosemeter as 1,4 30°-75° 1,3 90° angle of radiation incidence ) TLD-1K-V4 used and tested by the Dosimetry Service Seibersdorf are coded de- 1,2 1,1 tection cards containing lithium fluoride TLD chips. One or two cards (Cs,0 ° 0 1,0 0,9 are centred within the dosemeter and protected against humidity ) / R α α α α 0,8 IEC lower limit 0°-75° and by an envelope foil. ( E , 0,7 R 0,6 IEC lower limit 75°-90° 0,5 • Outer Dimensions: 60 mm diameter, 63 mm height 0,4 0,3 • Inner slit dimensions: 32 mm x 5 mm x 50 mm 10 100 1000 10000 • Reference point: geometrical centre, not marked Eave (keV) • Reference direction: seal towards source Combined energy and angular response of the TLD-1K-V4 • Reference radiation quality: S-Cs gamma radiation (ISO 4037)

Components of the area dosemeter Seibersdorf TLD-2K-V4 used for environmental monitoring

TLD AREA DOSIMETRY DOSIMETRY SERVICE SEIBERSDORF

Thermoluminescent dosimetry (TLD) is one of the most reliable me- The monitoring service of the Seibersdorf offers an ex- thods for detecting ionising radiation covering a wide dose range tensive radiation safety programme for our costumers from medical and measurement periods of several months. professions, industry, emergency organizations und research insti- tutions. Our highest quality standards are based on many years of In contrast to personal monitoring, area dosemeter measurements experience as one of the first European services using continuously are related to fixed measurement sites assessing potential exposure improved and extended thermoluminescent dosemeters. to individuals. Accurate determination of ambient dose equivalent within restricted areas or in their environment allows safeguarding or improving radiation protection policy. ISO 9001 certified Ambient dose equivalent (unit microsievert µSv) results include con- ISO/IEC 17025 accredited tributions due to natural and transport, which approved by the Federal Office may be taken into account by the user. Analysis of provided average of Metrology and Surveying ambient dose equivalent rates (unit µSv/h) allows comparisons to previous measurement results and exposure limits and estimations of annual dose values.

03 CONTACT Seibersdorf Labor GmbH Radiation Protection Dosimetry DOSIMETRY SERVICE 2444 Seibersdorf, Austria www.seibersdorf-laboratories.at/dosimeterservice Fax: +43 (0) 50550 - 3001

DOSIMETRY SERVICE Secretary +43 (0) 50550 - 3000 [email protected] Seibersdorf Labor GmbH · v13082015 © 2015