SCST, a SCSI Target Framework Bart Van Assche, Ph.D
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Clustered Data ONTAP® 8.3 SAN Configuration Guide
Updated for 8.3.1 Clustered Data ONTAP® 8.3 SAN Configuration Guide NetApp, Inc. Telephone: +1 (408) 822-6000 Part number: 215-10114_A0 495 East Java Drive Fax: +1 (408) 822-4501 June 2015 Sunnyvale, CA 94089 Support telephone: +1 (888) 463-8277 U.S. Web: www.netapp.com Feedback: [email protected] Table of Contents | 3 Contents Considerations for iSCSI configurations .................................................... 5 Ways to configure iSCSI SAN hosts with single nodes .............................................. 5 Ways to configure iSCSI SAN hosts with HA pairs ................................................... 7 Benefits of using VLANs in iSCSI configurations ..................................................... 8 Static VLANs .................................................................................................. 8 Dynamic VLANs ............................................................................................. 9 Considerations for FC configurations ...................................................... 10 Ways to configure FC SAN hosts with single nodes ................................................. 10 Ways to configure FC with HA pairs ........................................................................ 12 FC switch configuration best practices ..................................................................... 13 Supported number of FC hop counts ......................................................................... 13 Supported FC ports ................................................................................................... -
Fibre Channel Interface
Fibre Channel Interface Fibre Channel Interface ©2006, Seagate Technology LLC All rights reserved Publication number: 100293070, Rev. A March 2006 Seagate and Seagate Technology are registered trademarks of Seagate Technology LLC. SeaTools, SeaFONE, SeaBOARD, SeaTDD, and the Wave logo are either registered trade- marks or trademarks of Seagate Technology LLC. Other product names are registered trade- marks or trademarks of their owners. Seagate reserves the right to change, without notice, product offerings or specifications. No part of this publication may be reproduced in any form without written permission of Seagate Technol- ogy LLC. Revision status summary sheet Revision Date Writer/Engineer Sheets Affected A 03/08/06 C. Chalupa/J. Coomes All iv Fibre Channel Interface Manual, Rev. A Contents 1.0 Contents . i 2.0 Publication overview . 1 2.1 Acknowledgements . 1 2.2 How to use this manual . 1 2.3 General interface description. 2 3.0 Introduction to Fibre Channel . 3 3.1 General information . 3 3.2 Channels vs. networks . 4 3.3 The advantages of Fibre Channel . 4 4.0 Fibre Channel standards . 5 4.1 General information . 6 4.1.1 Description of Fibre Channel levels . 6 4.1.1.1 FC-0 . .6 4.1.1.2 FC-1 . .6 4.1.1.3 FC-1.5 . .6 4.1.1.4 FC-2 . .6 4.1.1.5 FC-3 . .6 4.1.1.6 FC-4 . .7 4.1.2 Relationship between the levels. 7 4.1.3 Topology standards . 7 4.1.4 FC Implementation Guide (FC-IG) . 7 4.1.5 Applicable Documents . -
What Is It and How We Use It
Infiniband Overview What is it and how we use it What is Infiniband • Infiniband is a contraction of "Infinite Bandwidth" o can keep bundling links so there is no theoretical limit o Target design goal is to always be faster than the PCI bus. • Infiniband should not be the bottleneck. • Credit based flow control o data is never sent if receiver can not guarantee sufficient buffering What is Infiniband • Infiniband is a switched fabric network o low latency o high throughput o failover • Superset of VIA (Virtual Interface Architecture) o Infiniband o RoCE (RDMA over Converged Ethernet) o iWarp (Internet Wide Area RDMA Protocol) What is Infiniband • Serial traffic is split into incoming and outgoing relative to any port • Currently 5 data rates o Single Data Rate (SDR), 2.5Gbps o Double Data Rate (DDR), 5 Gbps o Quadruple Data Rate (QDR), 10 Gbps o Fourteen Data Rate (FDR), 14.0625 Gbps o Enhanced Data Rate (EDR) 25.78125 Gbps • Links can be bonded together, 1x, 4x, 8x and 12x HDR - High Data Rate NDR - Next Data Rate Infiniband Road Map (Infiniband Trade Association) What is Infiniband • SDR, DDR, and QDR use 8B/10B encoding o 10 bits carry 8 bits of data o data rate is 80% of signal rate • FDR and EDR use 64B/66B encoding o 66 bits carry 64 bits of data Signal Rate Latency SDR 200ns DDR 140ns QDR 100ns Hardware 2 Hardware vendors • Mellanox o bought Voltaire • Intel o bought Qlogic Infiniband business unit Need to standardize hardware. Mellanox and Qlogic cards work in different ways. -
AMD Opteron™ Shared Memory MP Systems Ardsher Ahmed Pat Conway Bill Hughes Fred Weber Agenda
AMD Opteron™ Shared Memory MP Systems Ardsher Ahmed Pat Conway Bill Hughes Fred Weber Agenda • Glueless MP systems • MP system configurations • Cache coherence protocol • 2-, 4-, and 8-way MP system topologies • Beyond 8-way MP systems September 22, 2002 Hot Chips 14 2 AMD Opteron™ Processor Architecture DRAM 5.3 GB/s 128-bit MCT CPU SRQ XBAR HT HT HT 3.2 GB/s per direction 3.2 GB/s per direction @ 0+]'DWD5DWH @ 0+]'DWD5DWH 3.2 GB/s per direction @ 0+]'DWD5DWH HT = HyperTransport™ technology September 22, 2002 Hot Chips 14 3 Glueless MP System DRAM DRAM MCT CPU MCT CPU SRQ SRQ non-Coherent HyperTransport™ Link XBAR XBAR HT I/O I/O I/O HT cHT cHT cHT cHT Coherent HyperTransport ™ cHT cHT I/O I/O HT HT cHT cHT XBAR XBAR CPU MCT CPU MCT SRQ SRQ HT = HyperTransport™ technology DRAM DRAM September 22, 2002 Hot Chips 14 4 MP Architecture • Programming model of memory is effectively SMP – Physical address space is flat and fully coherent – Far to near memory latency ratio in a 4P system is designed to be < 1.4 – Latency difference between remote and local memory is comparable to the difference between a DRAM page hit and a DRAM page conflict – DRAM locations can be contiguous or interleaved – No processor affinity or NUMA tuning required • MP support designed in from the beginning – Lower overall chip count results in outstanding system reliability – Memory Controller and XBAR operate at the processor frequency – Memory subsystem scale with frequency improvements September 22, 2002 Hot Chips 14 5 MP Architecture (contd.) • Integrated Memory Controller -
Architecture and Application of Infortrend Infiniband Design
Architecture and Application of Infortrend InfiniBand Design Application Note Version: 1.3 Updated: October, 2018 Abstract: Focusing on the architecture and application of InfiniBand technology, this document introduces the architecture, application scenarios and highlights of the Infortrend InfiniBand host module design. Infortrend InfiniBand Host Module Design Contents Contents ............................................................................................................................................. 2 What is InfiniBand .............................................................................................................................. 3 Overview and Background .................................................................................................... 3 Basics of InfiniBand .............................................................................................................. 3 Hardware ....................................................................................................................... 3 Architecture ................................................................................................................... 4 Application Scenarios for HPC ............................................................................................................. 5 Current Limitation .............................................................................................................................. 6 Infortrend InfiniBand Host Board Design ............................................................................................ -
FICON Native Implementation and Reference Guide
Front cover FICON Native Implementation and Reference Guide Architecture, terminology, and topology concepts Planning, implemention, and migration guidance Realistic examples and scenarios Bill White JongHak Kim Manfred Lindenau Ken Trowell ibm.com/redbooks International Technical Support Organization FICON Native Implementation and Reference Guide October 2002 SG24-6266-01 Note: Before using this information and the product it supports, read the information in “Notices” on page vii. Second Edition (October 2002) This edition applies to FICON channel adaptors installed and running in FICON native (FC) mode in the IBM zSeries procressors (at hardware driver level 3G) and the IBM 9672 Generation 5 and Generation 6 processors (at hardware driver level 26). © Copyright International Business Machines Corporation 2001, 2002. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . vii Trademarks . viii Preface . ix The team that wrote this redbook. ix Become a published author . .x Comments welcome. .x Chapter 1. Overview . 1 1.1 How to use this redbook . 2 1.2 Introduction to FICON . 2 1.3 zSeries and S/390 9672 G5/G6 I/O connectivity. 3 1.4 zSeries and S/390 FICON channel benefits . 5 Chapter 2. FICON topology and terminology . 9 2.1 Basic Fibre Channel terminology . 10 2.2 FICON channel topology. 12 2.2.1 Point-to-point configuration . 14 2.2.2 Switched point-to-point configuration . 15 2.2.3 Cascaded FICON Directors configuration. 16 2.3 Access control. 18 2.4 Fibre Channel and FICON terminology. -
Chapter 6 MIDI, SCSI, and Sample Dumps
MIDI, SCSI, and Sample Dumps SCSI Guidelines Chapter 6 MIDI, SCSI, and Sample Dumps SCSI Guidelines The following sections contain information on using SCSI with the K2600, as well as speciÞc sections dealing with the Mac and the K2600. Disk Size Restrictions The K2600 accepts hard disks with up to 2 gigabytes of storage capacity. If you attach an unformatted disk that is larger than 2 gigabytes, the K2600 will still be able to format it, but only as a 2 gigabyte disk. If you attach a formatted disk larger than 2 gigabytes, the K2600 will not be able to work with it; you could reformat the disk, but thisÑof courseÑwould erase the disk entirely. Configuring a SCSI Chain Here are some basic guidelines to follow when conÞguring a SCSI chain: 1. According to the SCSI SpeciÞcation, the maximum SCSI cable length is 6 meters (19.69 feet). You should limit the total length of all SCSI cables connecting external SCSI devices with Kurzweil products to 17 feet (5.2 meters). To calculate the total SCSI cable length, add the lengths of all SCSI cables, plus eight inches for every external SCSI device connected. No single cable length in the chain should exceed eight feet. 2. The Þrst and last devices in the chain must be terminated. There is a single exception to this rule, however. A K2600 with an internal hard drive and no external SCSI devices attached should have its termination disabled. If you later add an external device to the K2600Õs SCSI chain, you must enable the K2600Õs termination at that time. -
Application Note 904 an Introduction to the Differential SCSI Interface
DS36954 Application Note 904 An Introduction to the Differential SCSI Interface Literature Number: SNLA033 An Introduction to the Differential SCSI Interface AN-904 National Semiconductor An Introduction to the Application Note 904 John Goldie Differential SCSI Interface August 1993 OVERVIEW different devices to be connected to the same daisy chained The scope of this application note is to provide an introduc- cable (SCSI-1 and 2 allows up to eight devices while the pro- tion to the SCSI Parallel Interface and insight into the differ- posed SCSI-3 standard will allow up to 32 devices). A typical ential option specified by the SCSI standards. This applica- SCSI bus configuration is shown in Figure 1. tion covers the following topics: WHY DIFFERENTIAL SCSI? • The SCSI Interface In comparison to single-ended SCSI, differential SCSI costs • Why Differential SCSI? more and has additional power and PC board space require- • The SCSI Bus ments. However, the gained benefits are well worth the addi- • SCSI Bus States tional IC cost, PCB space, and required power in many appli- • SCSI Options: Fast and Wide cations. Differential SCSI provides the following benefits over single-ended SCSI: • The SCSI Termination • Reliable High Transfer Rates — easily capable of operat- • SCSI Controller Requirements ing at 10MT/s (Fast SCSI) without special attention to termi- • Summary of SCSI Standards nations. Even higher data rates are currently being standard- • References/Standards ized (FAST-20 @ 20MT/s). The companion Application Note (AN-905) focuses on the THE SCSI INTERFACE features of National’s new RS-485 hex transceiver. The The Small Computer System Interface is an ANSI (American DS36BC956 specifically designed for use in differential SCSI National Standards Institute) interface standard defining a applications is also optimal for use in other high speed, par- peer to peer generic input/output bus (I/O bus). -
Fibre Channel and Iscsi Configuration Guide for the Data ONTAP® 8.0 Release Family
Fibre Channel and iSCSI Configuration Guide for the Data ONTAP® 8.0 Release Family NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web: www.netapp.com Feedback: [email protected] Part number: 215-08164_A0 August 2013 Table of Contents | 3 Contents iSCSI configurations .................................................................................... 6 Single-network HA pair in an iSCSI SAN .................................................................. 6 Multi-network HA pair in an iSCSI SAN ................................................................... 7 Direct-attached single-controller configurations in an iSCSI SAN ............................ 8 VLANs for iSCSI configurations ................................................................................ 9 Static VLANs ................................................................................................ 10 Dynamic VLANs ........................................................................................... 10 Fibre Channel configurations .................................................................... 11 FC onboard and expansion port combinations .......................................................... 11 Fibre Channel supported hop count .......................................................................... 12 Fibre Channel supported speeds ................................................................................ 13 Fibre Channel switch -
Product Manual: Ultrastar DC HC620 (Hs14) SAS OEM
Hard disk drive specifications Ultrastar® DC HC620 (previously known as Ultrastar Hs14 14TB/15TB) 3.5 inch Serial Attached SCSI hard disk drive Model: HSH721414AL52M0/4 HSH721414AL42M0/4 HSH721415AL52M0/4 HSH721415AL42M0/4 Revision 1.6 31 January 2020 1 Hard Disk Drive Specification Publication Disclaimer Information One MB is equal to one million bytes, one GB is equal to one billion bytes and one TB equals 1,000GB (one trillion bytes) when referring to storage capacity. Accessible capacity will vary from the stated capacity due to formatting and partitioning of the drive, the computer’s operating system, and other factors. The following paragraph does not apply to any jurisdiction where such provisions are inconsistent with local law: THIS PUBLICATION IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This publication could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. There may be improvements or changes in any products or programs described in this publication at any time. It is possible that this publication may contain reference to, or information about, Western Digital products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Western Digital Corporation intends to announce such Western Digital products, programming, or services in your country. Technical information about this product is available by contacting your local Western Digital product representative or on the Internet at: [email protected]. -
IBM Flex System IB6131 Infiniband Switch User's Guide
IBM Flex System IB6131 InfiniBand Switch User’s Guide ii IBM Flex System IB6131 InfiniBand Switch User’s Guide IBM Flex System IB6131 InfiniBand Switch User’s Guide Note: Before using this information and the product it supports, read the general information in , ʺAppen‐ dix B: Noticesʺ on page 33, the Safety Information and Environmental Notices and Userʹs Guide docu‐ ments on the IBM Notices for Network Devices CD, and the Warranty Information document that comes with the product. First Edition February 2012 © Copyright IBM Corporation 2012. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Safety . vii Chapter1. Introduction . 1 Related documentation. 1 Notices and statements in this document . 3 Features and specifications. 3 Specifications . 4 Major components of the switch . 5 Chapter2. Installing the switch and basic setup. 7 Installing the IBM Flex system blade . 7 CMM . 7 Serial port access (Method 1) . 7 Configuration . 9 Configuration Wizard (Method 2) . 9 Cabling the switch . 15 Chapter3. LEDs and interfaces. 17 Port LEDs . 17 Switch status lights . 17 Power LED . 18 Fault LED . 18 Unit identification switch identifier LED . 18 RS‐232 interface through mini connector. 18 RJ‐45 Ethernet connector . 19 Configuring the IBM Flex System IB6131 InfiniBand switch . 19 Rerunning the Wizard. 19 Updating the switch software . 20 Chapter4. Connecting to the switch platform . 25 Starting an SSH connection to the switch (CLI) . 25 Starting a WebUI connection to the switch . 25 Managing the IBM Flex System IB6131 InfiniBand switch . 26 Chapter5. Solving problems . 27 Running POST . -
Global MV Standards English
www.visiononline.org www.emva.org www.jiia.org www.china-vision.org www.vdma.com/vision Member-supported trade associations promote the growth of the global vision and imaging industry. Standards development is key to the success of the industry and its trade groups help fund, maintain, manage and promote standards. In 2009, three leading vision associations, AIA, EMVA and JIIA began a cooperative initiative to coordinate the development of globally adopted vision standards. In 2015 they were joined by CMVU and VDMA-MV. This publication is one product of this cooperative effort. Version: April 2016 Copyright 2013, AIA, EMVA and JIIA. All rights reserved. Data within is intended as an information resource and no warranty for its use is given. Camera Link (including PoCL and PoCL-Lite), Camera Link HS, GigE Vision and USB3 Vision are the trademarks of AIA. GenICam is the trademark of EMVA. CoaXPress and IIDC2 are the trademarks of JIIA. FireWire is the trademark of Apple Inc. IEEE 1394 is the trademark of The 1394 Trade Association. USB is the trademark of USB Implementers Forum, Inc. All other names are trademarks or trade names of their respective companies. This is a comprehensive look at the various digital hardware and software interface standards used in machine vision and imaging. In the early days of machine vision, the industry adopted existing analog television standards such as CCIR or RS-170 for the interface between cameras and frame grabbers. The defining In the 1990s, digital technology became characteristics of today’s prevalent and a multitude of proprietary hardware and software interface solutions were used.