General Service Safety SSR3-Solid State Relay...... 22 Information Start and Run Introduction...... 6 Replacement Kits...... 24

Trained Personnel Only...... 6 Introduction to ESP Master Replacement Guide...... 25 Terminal Venting and Electrocution...... 7 ESP Master Refrigerants and Other Chemicals...... 10 Replacement Guide...... 26

Compressor Removal...... 11 Introduction to Electrical Drawings...... 81 System Flushing, Purging, and Pressure Testing for Leaks...... 12 Trouble Shooting and Service Chart...... 103 System Charging...... 14

Prevention of Water-Utilizing System Explosions...... 15

Start Capacitor Overheating...... 18

System Evacuation...... 18

Follow the Labels...... 18

Additional Information...... 18

Serial Label Information...... 19 Introduction Tecumseh Products Company LLC has prepared this guidebook to assist service personnel in safely working with refrigeration and air conditioning equipment that uses Tecumseh hermetic compressors. It is not designed to replace the training required for professional service personnel. It is also not intended to replace other information available from refrigeration and air conditioning equipment manufacturers.

Trained Personnel Only Servicing, repairing, and troubleshooting refrigeration and air conditioning systems should be done only be those with the necessary knowledge, training, and equipment.

WARNING

Never service, repair, or troubleshoot unless you are qualified to perform these functions. Improper servicing can lead to serious injury or death from fire, electrical shock, or explosion.

6 Terminal Venting and Electrocution Improperly servicing, repairing, or troubleshooting a compressor can lead to electro- cution or fire due to terminal venting with ignition. Follow the precautions below to avoid serious injury or death from electrocution or terminal venting with ignition.

Fire Hazard from Terminal Venting with Ignition Oil and refrigerant can spray out of the compressor if one of the terminal pins is ejected from the hermetic terminal. This “terminal venting” can occur as a result of a ground fault (also known as a short circuit to ground) in the compressor. The oil and refrigerant spray from terminal venting can be ignited by and produce flames that can lead to serious burns or death. See figures 1 through 3 for detail.

Figure 1

Compressor with (1) protective terminal cover and (2) bale strap removed to show (3) hermetic terminal.

7 Figure 2

Close-up view of hermetic terminal showing individual terminal pins with power leads removed.

Figure 3

Close-up view of hermetic terminal after it has vented.

Terminal Venting and Electrocution Precautions To reduce the risk of electrocution or serious burns or death from terminal venting with ignition: Be alert for sounds or arcing (sizzling, sputtering or popping) inside the compressor, IMMEDIATELY GET AWAY if you hear these sounds. Disconnect ALL electrical power before removing the protective terminal cover. Make sure that all power legs are open. (NOTE: the system may have more than one power supply.) Never energize the system unless: 1) the protective terminal cover is securely fastened, and 2) the compressor is properly connected to ground. Figures 4 through 6 illustrate the different means of fastening protective terminal covers.

8 Figure 4

Compressor with (1) protective terminal cover held in place by (2) metal bale strap.

Figure 5

Compressor with (1) protective terminal cover held in place by (2) nut.

Figure 6

Compressor with (1) snap-in protective terminal cover.

9 Terminal Venting and Electrocution Precautions (continued)

Never reset a breaker or replace a without first checking for a ground fault (a short circuit to ground). An open fuse or tripped is a strong indication of a ground fault (also know as a short circuit to ground). Use only a megohmmeter (“megger”) or a Hi-Potential Ground tester (Hi-Pot) to check for a ground fault. A conventional ohmmeter will not reliably detect a ground fault under certain circumstances. See the Service Handbook for more information on checking for a ground fault. Also, always follow the megger or Hi-Pot manufacturer’s procedures and safety rules. If a ground fault does exist, keep the power off. WARNING! To avoid electric shock, electrocution, and terminal venting with ignition, do not energize a compressor that has a ground fault. Mark and red tag the compressor to indicate that there is a ground fault. Do not reconnect the power leads. Tape and insulate each power lead separately. Disconnect power before servicing. Always disconnect power before servicing, unless it is required for a specific troubleshooting technique. In these situations, use extreme caution to avoid electrical shock.

Refrigerants and Other Chemicals Contact with refrigerant, mixtures of refrigerant and oil, or other chemicals can cause a variety of injuries including burns and frostbite. For example, if refrigerant contacts skin or eyes it can cause severe frostbite. Also, in the event of a compressor motor failure, some refrigerant and oil mixtures can be acidic and cause chemical burns.

To avoid injury, wear appropriate protective eyewear, gloves, and clothing when servicing an air conditioning or refrigeration system. Refer to your refrigerant supplier for more information.

If refrigerant or mixtures of refrigerant and oil come in contact with skin or eyes, flush the exposed area with water and get medical attention immediately.

10 Compressor Removal Failure to properly remove the compressor can result in serious injury or death from electrocution, fire, or sudden release of refrigerant and oil.

Follow these precautions when removing a compressor from a system:

Disconnect ALL electrical power.

Disconnect all electrical power supplies to the system, making sure that all power legs are open. (NOTE: The system may have more than one power supply.)

Be sure refrigerant is recovered before removing compressor.

Attempting to remove the compressor before removing all refrigerant from the system can cause a sudden release of refrigerant and oil. Among other things, this can: • Cause a variety of injuries including burns or frostbite. • Cause a fire if a torch is used to disconnect tubing. • Expose the service person to toxic gas. To avoid serious injury or death, be sure to remove and recover all refrigerant before removing the compressor.

Use a tubing cutter, not a torch.

Use a tubing cutter to remove the compressor. A torch can cause even trace amounts of refrigerant to decompose and release toxic fumes. In addition, using a torch to remove the compressor can cause a fire. If you ignore this recommendation and use a torch, be prepared to extinguish a fire.

11 System Flushing, Purging, and Pressure Testing for Leaks Failure to properly flush, purge, or pressure test a system for leaks can result in serious injury or death from explosion, fire, or contact with acid-saturated refrigerant or oil mists.

Follow these precautions when flushing/purging a system or pressure testing a system for leaks: Use flushing products according to the manufacturer’s instructions. To purge a system, use only dry nitrogen. When pressure testing for leaks, use only regulated dry nitrogen or dry nitrogen plus trace amounts of the serial label refrigerant. When purging or pressure testing any refrigeration or air conditioning system for leaks, never use air, oxygen or acetylene. • Oxygen can explode on contact with oil. • Acetylene can decompose and explode when exposed to pressures greater than approximately 15 psig. • Combining an oxidizing gas, such as oxygen air, with an HCFC or HFC refrigerant under pressure can result in a fire or explosion.

Use a pressure regulating valve and pressure gauges. Commercial cylinders of nitrogen contain pressures in excess of 2000 psig at 70°F. At pressures much lower than 2000 psig, compressors can explode and cause serious injury or death. To avoid overpressurizing the system, always use a pressure regulating valve on the nitrogen cylinder discharge (see Figure 7). The pressure regulator must be able to reduce the pressure down to 1 or 2 psig and maintain this pressure. The regulating valve must be equipped with two pressure gauges: • one gauge to measure cylinder pressure, and • one gauge to measure discharge or downstream pressure.

12 Use a pressure relief valve. In addition to pressure regulating valve and pressure gauges, always install a pressure relief valve. This can also be a frangible disc type pressure relief device. This device should have a discharge port of at least ½" MPT size. The valve or frangible disc device must be set to release at 175 psig (see Figure 7).

Figure 7

Gauges

Regulating To System Valve

Relief Valve 175 psig Setting

Dry nitrogen cylinder with attached pressure regulating and relief valves and pressure gauges needed for pressure testing for leaks and purging.

Do not pressurize the system beyond 150 psig field leak test pressure. When field testing a system for leaks, 150 psig is adequate test pressure.

Disconnect nitrogen cylinder and evacuate the system before connecting the refrigerant container. Disconnect the nitrogen cylinder and release the pressure in the system before connecting a refrigerant container to the system. The higher pressure gas in the system can explode the refrigerant container.

13 System Charging Failure to properly charge the system can result in serious injury or death from explosion or fire.

Follow these precautions when charging a system:

Do not operate the compressor without charge in the system. Operating the compressor without a charge in the system can damage the hermetic terminal. As always, to avoid serious injury or death from terminal venting with ignition, never energize the compressor unless the protective terminal cover is securely fastened.

Use proper refrigerant. Use only the compressor serial label refrigerant when charging the system. Using a different refrigerant can lead to excess system pressure and an explosion. Use of a refrigerant other than the serial label refrigerant voids the compressor warranty.

Do not overcharge a refrigeration or air conditioning system. Overcharging a refrigeration or air conditioning system can result in an explosion. To avoid serious injury or death, never overcharge the system. Always use proper charging techniques. Limit charge amounts to those specified on the system equipment serial label or in the original equipment manufacturer’s service information. Overcharging the system immerses the compressor motor, piston, connecting rods, and cylinders in liquid refrigerant. This creates a hydraulic block preventing the compressor from starting. The hydraulic block is also known as locked rotor. Continued supply of electricity to the system causes heat to build in the compressor. This heat will eventually vaporize the refrigerant and rapidly increase system pressure. If, for any reason, the thermal protector fails to open the electrical circuit, system pressure can rise to high enough levels to cause a compressor housing explosion.

14 Prevention of Water-Utilizing System Explosions In certain water-utilizing refrigeration systems, water can leak into the refrigerant side of the system. This can lead to an explosion of system components, including but not limited to the compressor. If such an explosion occurs, the resulting blast can kill or seriously injure anyone in the vicinity.

Systems at Risk of Explosion Water-utilizing systems that have single-wall heat exchangers may present a risk of explosion. Such systems may include:

• water source heat pump/air conditioning systems, and • water cooling systems, such as icemakers, water coolers, and juice dispensers. Water-utilizing systems that have single-wall heat exchangers present a risk of explosion unless they have either:

• a high pressure cut-out which interrupts power to ALL leads to compressor, or • an external pressure relief valve.

How an Explosion Occurs If the refrigerant tubing in the heat exchanger develops a leak, water can enter the refrigerant side of the system. Water entering the refrigerant side can come in contact with live electrical connections in the compressor causing a short circuit or a path to ground. When this occurs, extremely high temperatures can result. The heat build-up creates steam vapor that can cause excessive pressure throughout the entire system. This system pressure can lead to an explosion of the compressor or other system components.

15 Service Procedures In light of the risk of explosion, be especially alert for signs of water leaking into the refrigerant side of the system. Whenever servicing or troubleshooting a water- utilizing system, always check to see if it has either a pressure relief valve or a high pressure cut-out as previously described. If the system does not have at least one of these, DISCONNECT ALL ELECTRICAL POWER and look for indications that water has leaked into the refrigerant side of the system. These indications may include: • Observation of a report of a blown fuse or tripped circuit breaker. • Signs that water has leaked to the outside of the system. • Reports that the system has made gurgling or percolating noises. • A history of loss of refrigerant charge without a leak being found in the system. NOTE: Common leak detection methods will not detect a water-to-refrigerant leak in the system’s heat exchanger(s). • Observation of or a report of the compressor giving off an unusual amount of heat. If ANY of these indications are present, do the following checks to determine if water has leaked into the refrigerant side:

Step 1: Check for a Ground Fault (a short to ground) Use only a megohmmeter (“megger”) or a Hi-Potential Ground tester (“Hi-Pot”) to check for a ground fault. A conventional ohmmeter will not reliably detect a ground fault under certain circumstances. See the Service Handbook for more information on checking for a ground fault. Also, always follow the megger or Hi-Pot manufacturer’s procedures and safety rules. • If a ground fault does not exist, go to Step 2. • If a ground fault does exist, keep the power off. WARNING! To avoid electric shock, electrocution, and terminal venting with ignition, do not energize a compressor that has a ground fault. Mark and red tag the compressor to indicate that there is a ground fault. Do not reconnect the power leads. Tape and insulate each power lead separately. Proceed to Step 2. Do not replace the compressor or energize the system before performing Step 2.

16 Step 2: Check for Water in the System Once the compressor is cool to the touch, open the system process valve slightly to see if any water comes out of the system. WARNING! Opening the system process valve while the compressor is hot can cause severe burns from steam coming out of the valve.

If ANY water comes out of the process valve, the entire system must be replaced. See “Replacing a Single-Wall Water-Utilizing System” below. If water does not come out of the process valve, there is still a possibility that some water has leaked into the refrigerant side of the system. To address this possibility, determine if the system has a history of losing refrigerant charge without a leak being found or repaired. If you find ANY indication of a history of losing refrigerant charge without detection of a leak, this is a sign that refrigerant has leaked in the water inside the heat exchanger. The entire system must be replaced. See “Replacing a Single-Wall Water-Utilizing System” below. If you do not find any indication of a history of loss of charge without detection of a leak, you still need to install: • a high pressure cut-out which interrupts power to ALL leads to the compressor, or • an external pressure relief valve. Also, if you found a ground fault in the compressor in Step 1, replace the compressor before applying power to the system.

Replacing a Single-Wall Water-Utilizing System When replacing a single-wall water-utilizing system, replace the system with one that has: • a double-wall heat exchanger(s), or • a high-pressure cut-out which interrupts power to ALL leads to the compressor, or • an external pressure relief valve.

17 Start Capacitor Overheating An overheated start capacitor can burst and spray or splatter hot material which can cause burns. Applying voltage to a start capacitor for more than a few seconds can cause the capacitor to overheat.

Check with a capacitance meter, and never check a capacitor with the power on. Use a 20,000 Ohm to discharge the start capacitor, before removing it from the system. System Evacuation Never use a compressor to evacuate a system. Instead, use a high pump specifically designed for that purpose.

Never start the compressor while it is under deep vacuum. Always break a vacuum with refrigerant charge before energizing the compressor.

Failure to follow these instructions can damage the hermetic terminal. As always, to avoid serious injury or death from terminal venting with ignition, never energize the compressor unless the protective terminal cover is securely fastened. Follow the Labels Tecumseh compressors have labels and markings with important information. For your safety and the safety of others, read the labels and markings on the product. Additional Information For additional information, request a Tecumseh Service Handbook (call 1-800-211-3427), contact a Tecumseh Authorized Wholesale Distributor, or visit www.tecumseh.com.

18 Serial Label Information The only source for complete compressor information is on the compressor serial label. On earlier compressors, the serial plate is usually spot welded on the upper housing of the compressor. For current compressors, the serial label is affixed in the same location. Both describe the characteristics of the compressor. The months are identified in Table 1. Figure 8 Model Number Bill of Material Number Serial Number AH301FT - 077 Code Date SE1490C 281254 AH5540E Second letter indicates month V230/208Hz60 LRA103.0 Next 2 digits indicate day of month V200 Hz50 PHI USA P Last 2 digits indicate year Electrical Rating Phase Volts - Hertz Example compressor serial plate

Figure 9 Bill of Material Number Appropriate Refrigerant*

Model Electrical Rating Number Volts - Hertz LRA (Locked Rotor Amps)

Code Date Data Matrix Code Letter indicates month Next 2 digits indicate day of month *NOTE: Actual color of background box is Yellow. Yellow box appears on all compressor serial labels. However, flammable symbol Last 2 digits indicate year only appears on R290/R600a compressors. Example compressor serial label

Table 1: Serial Label Month Identifiers A – January D – April G – July K – October B – February E – May H – August L – November C – March F – June J – September M – December

19 Figure 10 Manufacturing Code Date Month = September 0J0 Year = 2000 The letter represents the month (see Table 1). The numbers represent the year.

Example indoor condensing unit serial label

Figure 11

First letter indicates month (see Table 1), next 2 digits indicate day of the month, following 2 digits indicate year. Example outdoor condensing unit serial label

20 Electrical Parts Program

While Tecumseh compressors are designed and manufactured to the most exacting standards, a small percentage will require service, primarily due to the normal wear of electrical component parts such as compressor motor relays and overloads.

Replacement relays and overloads must be accurately matched to the specific compressor involved in order to assure proper performance and prevent equipment failure.

The Tecumseh Electrical Parts Program together with the comprehensive Parts Guidebook are designed to assist the service engineer in obtaining correct Tecumseh parts for Tecumseh compressors regardless of the end product in which the compressor is installed.

Your Tecumseh Authorized Wholesaler Distributor has complete stock of these parts, detailed wiring diagrams, cross reference data and the know-how to help you.

Any part numbers removed from this cross reference is due to obsolescence of the part. This also means that no current replacement parts are available to replace the old numbers and their existence has outlasted the lifetime expectations of the product.

21 Tecumseh Solid State Relay – SSR3 The SSR3 solid state relay may be used as a replacement for the current type on certain Tecumseh 115 volt RSIR compressors. Below and on the following page is information concerning the Tecumseh SSR3 relay. Instruction Sheet Solid State Relay – SSR3 This relay is intended to replace all current type push-on relays now specified for Tecumseh resistance start induction run (RSIR) compressors applied in household refrigerators and freezers. It is restricted to 115 volt operation. It is not to be used • to replace current type relays now specified for Tecumseh RSIR compressors applied in rapid-cycling systems such as water coolers, etc. • to replace current or potential type relays on Tecumseh capacitor start induction run (CSIR) compressors; it cannot be used along with a start capacitor. Note: For the above applications refer to Electrical Service Parts Guidebook for proper relay selection. Figure 13 Caution: This relay runs very hot during compressor operation. Temperatures in excess of 150°F (66°C) are not uncommon. Allow a cool down period after compressor shut down before attempting to handle or remove.

Installing and Wiring: 1. Disconnect power before removing protective cover. 2. Remove faulty relay and replace with SSR3. 3. Install and wire as shown in Figure 13. 4. If screw type relay termination is required, use adapter and screw provided. 5. Replace protective cover.

22 Use of Solid State Relays

Tecumseh’s position limiting the use of solid state relays to normal cycling 115 volt RSIR compressors is as follows:

A. It must be realized that a solid state relay is actuated on a thermal basis through the use of a material designated PTC. This PTC material is of a given cold resistance. It heats up rapidly as power is supplied, becomes non- conductive, and effectively opens the start winding circuit.

B. The usage of a CSIR compressor is generally one of intent in that high starting torque is needed in the application involved. Usually, this is because the compressor will be called upon to restart prior to complete pressure equalization (example, expansion valve systems). If a solid state relay is used on a CSIR compressor, the resistance added to the start winding circuit substantially reduced the starting torque. The result may be that the compressor will not start when required and will cycle on the overload for an undesirable length of time.

C. Additionally, if a solid state relay is used on an RSIR compressor applied in a rapid-cycling system, again a no-start situation could result. This is due to the cool-down period required of the PTC material, usually 4 to 6 minutes. In effect, the relay may still be hot (non-conductive) when called upon, the start winding will not be energized and the compressor will not restart.

The preceding comments apply to the Tecumseh SSR3 as well as all other solid state relays on the market.

23 Start and Run Capacitor Replacement Kits Replacement Replacement Start Cap P/N Kit Start Cap P/N Kit 85704 K146-03 85PS330C23 K146-12 85PS110C76 K146-17 85PS330084 K146-10 85PS110C90 K146-21 85PS330D12 K146-65 85PS110C91 K146-22 85PS330D14 K146-41 85PS110C92 K146-23 85PS330D15 K146-42 85PS125D59 K146-52 85PS330D16 K146-43 85PS165C27 K146-14 85PS330D17 K146-44 85PS165C27L1 K146-28 85PS330D18 K146-45 85PS165C42 K146-16 85PS330D23 K146-49 85PS165C77 K146-18 85PS330D80 K146-42 85PS165C78 K146-19 85PS165C95 K146-24 Start Cap P/N Replacement 85PS165C96 K146-25 Kit 85PS165C98 K146-27 85PR220F12 K150-02 85PS165C99 K146-28 85PR240F37 K150-08 85PS165D21 K146-47 85PR370E35 K150-06 85PS165D64 K146-55 85PR370E36 K150-03 85PS220D01 K146-29 85PR370E63 K150-16 85PS220D02 K146-66 85PR370F17 K150-14 85PS220D57 K146-51 85PR370F20 K150-07 85PS250A58 K146-05 85PR370F21 K150-18 85PS250B87 K146-09 85PR370F23 K150-12 85PS250C19 K146-10 85PR440E65 K150-19 85PS250C30 K146-15 85PR440E90 K150-22 85PS250D05 K146-32 85PR440F18 K150-15 85PS250D06 K146-33 85PR440F19 K150-10 85PS250D07 K146-34 85PR440F22 K150-11 85PS250D09 K146-36 85PR440F24 K150-04 85PS250D10 K146-37 85PR440F27 K150-13 85PS250D19 K146-46 85PR440F28 K150-17 85PS330C20 K146-11 85PR440F90 K150-23

24 Introduction to ESP Master Replacement Guide

This Guide should be used if the model number, voltage and application of the compressor are known.

Attention should be given to any explanation of information covered under the “Remarks” column. Coding is as follows:

S/Cap Start Capacitor R/Cap Run Capacitor Opt. Optional

All voltage shown are 60 hertz and unless otherwise specified are single phase.

All 3450 RPM air conditioning compressors have PSC motors but can be operated CSR by adding the optional starting components. When PSC starting problems are encountered, we recommend using the specified relay and start capacitor.

Certain refrigeration compressors may be serviced with either the specified current type relay or the SSR3 solid state relay.

25 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay K71-19 K71-19 K71-19 K71-19 K71-19 K71-19 K71-19 K71-19 K71-19 K71-19 K71-19 K71-17 K71-19 K71-17 K71-19 K71-17 K71-19 K71-17 K71-19 K71-17 K71-19 K71-19 K71-17 K71-19 K71-17

Run CapRun Part Number K150-06 K150-06 K150-06 K150-10 K150-06 K150-10 K150-10 K150-10 K150-10 K150-10 K150-07 K150-11 K150-07 K150-11 K150-07 K150-11 K150-07 K150-11 K150-07 K150-11 K150-07 K150-07 K150-11 K150-07 K150-11 Number Start Cap Part K146-12 K146-12 K146-11 K146-12 K146-11 K146-12 K146-12 K146-12 K146-12 K146-12 K146-36 K146-12 K146-36 K146-12 K146-36 K146-12 K146-36 K146-12 K146-36 K146-12 K146-36 K146-36 K146-12 K146-36 K146-12 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Start Winding Resistance ~ ~ 43.0 39.5 43.0 39.5 49.0 45.0 49.0 45.0 53.0 46.0 53.0 46.0 53.0 46.0 56.0 54.0 56.0 54.0 56.0 63.0 59.2 63.0 59.2 LRA ~ ~ 7.2 6.6 7.2 6.6 7.8 7.3 7.8 7.3 9.0 8.5 9.0 8.5 9.0 8.5 9.4 8.9 9.4 8.9 9.4 9.6 9.6 10.5 10.5 RLA Volts/Hz/Ph 208-230/60/1 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 Model AB5513G AB5513H AB5515G AB5515G AB5515H AB5515H AB5517G AB5517G AB5517H AB5517H AB5519 AB5519F AB5519G AB5519G AB5519H AB5519H AB5520F AB5520F AB5520G AB5520G AB5520H AB5522F AB5522F AB5522G AB5522G

26 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL 830-10109 K90-58 K90-58 K90-57 K90-80 830-10055 K90-80 K90-59 T96119-23-ZP 830-10118 570726 K90-117 830-10283 Relay K71-19 K71-19 82964 K71-19 82964 K71-19 K71-19 K71-19 K71-20 K71-19 K71-19 K71-19 SR171102-BE K71-38 K71-38 K71-37 K71-57 820-10109 K71-57 K71-39 8209660L74 820-10087 562692 K71-85 820-10219

Run CapRun Part Number K150-07 K150-14 K150-17 K150-14 K150-17 K150-14 K150-14 K150-14 K150-15 K150-14 K150-14 K150-14 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part K146-36 K146-36 K146-12 K146-36 K146-12 K146-36 K146-12 K146-36 K146-12 K146-36 K146-12 K146-12 ~ K146-28 K146-28 K146-28 K146-55 85PS165E36 K146-55 K146-28 85685 85PS165E26 581226 K146-14 85S-10009 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.4 2.3 2.3 2.0 1.4 2.0 1.4 1.7 6.7 1.4 0.9 0.9 3.6 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 6.0 4.6 4.6 5.0 3.4 6.2 3.4 4.1 4.2 3.9 4.1 15.6 19.2 Start Winding Resistance 63.0 64.0 61.0 64.0 61.0 64.0 77.0 80.0 72.0 80.0 87.0 87.0 26.5 28.5 28.5 28.0 29.0 25.5 29.0 32.0 15.5 32.5 36.0 45.0 19.0 LRA 2.7 3.1 3.1 3.6 3.5 3.5 3.5 4.5 2.1 5.2 5.8 5.8 2.6 10.5 11.0 10.2 11.0 10.2 11.0 12.9 13.3 11.9 13.3 14.0 14.0 RLA Volts/Hz/Ph 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 220/60/1 115/60/1 115/60/1 115-127/60/1 220/60/1 Model AB5522H AB5524F AB5524F AB5524G AB5524G AB5524H AB5527H AB5528G AB5528G AB5528H AB5530G AB5530H AE1390Y-AA1A AE2410A-AA1A AE2410Y-AA1A AE2410Z-AA1A AE2413A-AA1B AE2413U-AA1A AE2413Y-AA1B AE2415Z-AA1A AE2415Z-GS1A AE2420U-AA1A AE2420Z-AA1B AE2420Z-DS1B AE2420Z-GS1B

27 Remarks Overload 571555 K90-68 K90-54 K90-54 K90-60 K90-60 830-10143 830-10189 K90-65 830-10304 K90-55 K90-55 830-10113 K90-55 ~ 830-10325 830-10179 K90-66 830-10110 K90-56 K90-67 830-10071 K90-56 830-10310 K90-64 Relay 565411 K71-14 K71-34 K71-34 K71-42 K71-42 820-10069 820-10214 K71-45 RP4208-CXR K71-35 K71-35 820-10037 K71-35 820-10162 820-10030 820-10162 K71-46 8209660L88 K71-36 K71-41 820-10085 K71-36 ~ K71-44

Run CapRun Part Number 585310 85PR370E35 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part 541163 K146-58 ~ ~ ~ ~ 85PS250D07 85PS165E23 K146-28 85PS330E25 K146-17 K146-55 85PS165C99 K146-17 85S-10016 85PS110C76 85S-10016 K146-55 85PS165E26 K146-55 K146-28 85PS165E26 K146-55 ~ 85S-10016 3.9 0.9 2.9 2.9 1.9 1.6 5.4 3.0 2.1 8.3 1.9 1.7 2.3 1.9 8.6 1.9 8.6 1.7 1.6 1.7 1.3 1.6 1.7 1.1 5.5 Run 6.1 3.9 5.7 5.7 5.0 4.2 5.2 5.6 5.4 3.4 5.4 5.4 5.4 3.4 4.0 3.4 3.6 4.0 3.4 4.2 18.4 29.6 10.0 10.0 11.2 Start Winding Resistance 19.4 39.0 29.0 29.0 39.0 43.0 18.0 20.0 27.0 13.0 27.5 35.5 24.5 27.5 12.5 27.5 13.0 32.0 30.5 32.0 42.0 30.5 32.0 32.5 16.0 LRA 1.8 5.9 3.7 3.7 4.9 6.0 3.1 3.6 4.2 2.0 4.9 4.8 4.2 4.9 2.4 4.9 2.4 5.1 5.0 5.8 5.7 5.5 5.8 4.7 3.0 RLA Volts/Hz/Ph 220/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 115-127/60/1 115/60/1 115/60/1 220/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 115-127/60/1 115/60/1 115/60/1 100-115/60/1 208-230/60/1 Model AE2420Z-GS3C AE2425Z-AA3C AE3425A-AA1A AE3425Y-AA1A AE3430Y-AA1A AE3440Y-AA1A AE3440Y-XN1A AE4425Y-AA1A AE4425Z-AA1A AE4425Z-XN1A AE4430A-AA1A AE4430E-DS1A AE4430U-AA1A AE4430Y-AA1A AE4430Y-GS1A AE4430Y-XA1A AE4430Y-XN1A AE4430Z-AA1A AE4435U-AA1A AE4440A-AA1A AE4440E-DS1A AE4440U-AA1A AE4440Y-AA1A AE4440Y-AC3C AE4440Y-XN1A

28 Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Remarks Overload 83643 83004TMN16 8300MRPG06 T0926-58-ZP T43GC-58-ZP 83643 83781 8300MRTJ37 83004TMN72 K90-11 K90-67 K90-93 K90-61 830-10245 K90-69 K90-117 K90-70 830-10289 830-10036 ~ K90-71 K90-72 571328 ~ 8300MRTJ36 Relay 82404 K71-26 820RR12C20 RP4215-ZR RP2815-ZR 82462 82462 K71-01 82008EAJ54 8200EMBE47 K71-41 K71-73 K71-41 8200RVAM08 K71-48 K71-48 K71-49 820-10165 820-10095 ~ K71-51 K71-52 565172 ~ 82453

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 85PR440F95 ~ ~ ~ 85R-10016 ~ ~ 85PR370F23 85PR370F17 545103 ~ ~ Number Start Cap Part ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ K146-28 K146-55 K146-55 85PS330C24 K146-28 K146-55 K146-28 85PS330E25 85S-10085 ~ K146-28 K146-28 541162 ~ ~ ~ 5.2 5.2 4.2 4.7 7.6 7.6 1.0 4.6 1.6 1.4 0.9 1.1 3.5 1.2 0.9 0.8 3.3 0.9 0.8 0.8 2.4 1.6 1.6 Run 15.2 ~ 3.9 4.4 3.8 3.6 3.3 4.3 4.0 3.8 3.7 7.4 15.7 15.7 13.2 12.0 55.5 16.4 16.4 17.3 35.8 13.5 16.8 16.9 12.3 12.3 Start Winding Resistance ~ 8.5 13.9 14.6 14.0 11.7 11.7 40.0 21.8 28.0 36.0 42.5 42.0 24.5 38.0 45.0 44.5 18.0 43.5 49.6 49.0 48.0 29.0 28.0 28.0 LRA ~ 1.4 1.6 1.2 0.9 1.2 1.2 6.7 2.8 4.3 6.3 6.2 7.8 3.1 8.2 7.6 8.5 3.3 8.9 8.9 7.3 9.5 5.1 3.7 4.0 RLA Volts/Hz/Ph 115/60/1 115/60/1 115-127/60/1 115/60/1 220/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115-127/60/1 115/60/1 208-230/60/1 115/60/1 115-127/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 115/60/1 220/60/1 115/60/1 115/60/1 Model AEA1332AXA AEA1332YXA AEA1336ADS AEA1326YXA AEA1336AGS AEA1320AXA AEA1316YXA AEA0423AXA AEA0415ZXD AEA0418AXA AE4440Z-AA1A AE4450E-DS1B AE4450Y-AA1A AE4450Y-XN3C AE4450Z-AA1A AE4456E-DS1B AE4456Y-AA1C AE4456Y-XN3C AE4460U-AA1C AE4460U-AA2C AE4460Y-AA3C AE4470Z-AA3C AE4470Z-ES3C AEA0415EXA AEA0415ZXA

29 Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Remarks Overload 8300MRPD92 K90-15 K90-14 K90-17 K90-10 MRT24AIN-69 K90-79 K90-16 K90-11 8300MRPD60 K90-17 K90-11 K90-01 K90-03 T0513-58-ZP K90-02 T7112-58-ZP T0910-58-ZP K90-07 K90-04 T9506-58-ZP T1402-23-ZP 830-10014 K90-07 K90-07 Relay 8209660K28 K71-01 820RR12B11 K71-01 K71-09 RP6502-ZR 8209660A09 K71-60 K71-12 K71-12 K71-01 K71-12 K71-61 K71-05 RP3515-ZR K71-05 RP5015-ZR RP4015-ZR K71-08 K71-08 RP5715-ZR RP4218-ZR RP6018-ZR 82403 K71-04

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part K146-35 K146-14 ~ ~ K146-17 ~ ~ K146-17 K146-17 K146-17 K146-04 K146-17 K146-22 ~ ~ K146-22 ~ ~ ~ ~ ~ ~ 302P243-292F110 K146-22 ~ ~ ~ ~ 4.0 1.1 1.5 1.6 1.4 1.5 1.0 0.9 1.4 1.4 1.1 1.4 5.2 3.4 3.4 2.7 2.7 2.4 1.5 1.4 1.9 1.7 Run ~ ~ ~ 5.9 6.9 6.9 6.6 6.6 6.2 6.6 6.2 20.6 12.3 12.4 14.0 15.2 15.7 16.4 16.4 11.1 11.0 13.4 11.9 12.0 11.8 Start Winding Resistance ~ 20.5 40.0 35.0 28.0 31.0 35.0 37.5 39.0 30.2 30.2 40.0 30.2 14.6 18.0 11.0 18.0 19.5 15.3 22.0 20.7 36.0 36.0 31.0 24.0 LRA 2.9 5.9 4.1 3.2 4.5 4.6 5.0 5.2 4.4 4.5 5.6 4.4 1.7 2.1 1.2 2.3 2.5 1.3 2.5 2.0 3.7 1.5 3.5 3.7 2.6 RLA Volts/Hz/Ph 208-230/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 220/60/1 115/60/1 115/60/1 220/60/1 115/60/1 115/60/1 115-127/60/1 220/60/1 115/60/1 115/60/1 115/60/1 Model AEA2411ZXD AEA2411ZXA AEA1410AXA AEA1410YXA AEA1411EXA AEA1413AXA AEA1413YXA AEA1415EXA AEA2380ZXA AEA2410AXA AEA2410YXA AEA2411JXA AEA1336AXA AEA1338YXA AEA1343AGS AEA1343AXA AEA1360AAS AEA1360AGS AEA1360AXA AEA1360YXA AEA1380ADS AEA1380AGS AEA1380ALS AEA1380AXA AEA1380YXA

30 Alt relay: K71-01; Alt overload: K90-22 Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Remarks Overload K90-16 K90-21 8300MRPM67 8300MRAJ87 K90-07 K90-07 K90-01 K90-08 K90-10 8300MRAN80 K90-10 K90-10 K90-15 K90-15 ~ 83701 K90-07 K90-07 8300MRPF31 K90-07 K90-12 K90-17 K90-17 8300MRPD92 Relay K71-10 K71-10 K71-08 820RR12C28 K71-08 K71-08 8209660B21 ~ K71-04 82415 K71-09 K71-09 82453 K71-01 ~ RP13501-ZR K71-05 K71-05 820-10148 K71-08 K71-12 K71-01 K71-01 K71-04

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part K146-22 K146-22 ~ ~ K146-22 K146-22 ~ ~ K146-22 K146-29 ~ K146-22 ~ K146-14 ~ ~ K146-22 K146-22 ~ ~ K146-17 K146-04 K146-23 K146-30 1.5 1.5 4.6 1.0 2.7 2.7 6.9 2.3 2.3 6.9 1.8 1.8 1.0 1.1 0.7 3.4 3.4 2.7 1.4 1.1 1.1 3.9 Run 12.8 12.8 9.7 5.9 3.2 9.2 6.6 6.2 6.2 10.9 10.9 35.8 16.1 11.0 11.0 44.8 13.3 13.3 44.8 13.9 13.9 60.7 16.4 16.4 60.7 20.4 Start Winding Resistance 8.5 8.5 35.0 35.0 21.8 40.0 22.0 22.0 13.7 24.0 24.0 13.7 28.0 28.0 36.0 40.0 45.0 18.0 18.0 22.0 30.2 40.0 40.0 20.5 LRA ~ 6.8 6.9 3.6 8.7 3.4 3.4 1.9 4.4 4.4 2.2 5.0 5.2 5.7 5.9 1.2 2.9 2.9 1.6 3.3 4.8 5.9 6.0 3.1 RLA Volts/Hz/Ph 115/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 100/60/1 115/60/1 220/60/1 115/60/1 115/60/1 220/60/1 115/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 Model AEA3440AXA AEA3440YXA AEA3440YXD AEA3448AXA AEA2419ZXA AEA3417AXA AEA3417YXA AEA3417YXD AEA3425AXA AEA3425YXA AEA3425YXD AEA3430AXA AEA3430YXA AEA3430YXU AEA2416JXA AEA3414APP AEA3414AXA AEA3414YXA AEA3414YXP AEA3415ZXA AEA2413AXA AEA2413YXA AEA2415AAB AEA2415AXD

31 Tested without Condenser Fan Tested without Condenser Fan Remarks Overload T99394-23-ZP T12132-58-ZP T96107-58-ZP K90-16 K90-08 K90-19 K90-22 8300MRAN89 83949 K90-21 8300MRAA06 K90-114 8300MRPB68 T8900-83-ZP T96112-23-ZP T8632-42-ZP K90-12 8300MRAN76 T24932-58-ZP T89400-33-ZP K90-16 8300MRPA97 8300MRAJ87 K90-11 8300MRPB02 Relay RP6818-ZR RP6918-ZR RP5418-ZR K71-10 K71-08 K71-01 K71-01 8200EMBH90 K71-19 K71-19 K71-19 ~ K71-21 RP16208-ZR RP5218-ZR RP7008-ZR K71-09 820-10100 RP5418-ZR RP7518-ZR K71-10 K71-08 8209660K13 K71-09 82476

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ K150-07 K150-03 K150-03 K150-03 K150-04 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part 302P145-175F110 302P270-324F110 302P43-53F330 K146-21 K146-32 K146-23 K146-04 K146-35 ~ ~ ~ K146-11 K146-11 301P243-292F110 302P64-77F250 301P340-408F110 K146-17 K146-33 302P43-53F250 302P216-259F110 K146-21 K146-32 K146-23 K146-17 K146-29 ~ 1.3 1.1 4.6 1.3 4.7 1.1 1.1 3.7 1.4 1.1 0.9 3.0 4.5 5.8 5.8 1.4 1.8 5.8 1.1 1.3 4.8 1.0 1.8 5.6 Run ~ 8.4 6.2 6.2 8.6 4.9 5.1 8.6 5.2 10.6 18.8 10.9 27.4 20.8 13.6 12.8 11.8 12.0 24.6 25.9 14.9 10.9 26.7 17.3 14.8 Start Winding Resistance 32.7 40.0 18.0 32.7 19.0 40.0 40.0 24.5 28.0 31.0 34.0 20.0 16.0 29.0 17.5 39.0 29.0 14.4 18.0 39.0 32.7 16.8 40.0 29.0 14.4 LRA 7.4 8.2 3.9 7.2 3.9 8.0 8.2 5.3 6.2 7.0 7.7 4.0 3.3 5.6 3.1 6.6 5.3 2.8 4.0 7.4 6.8 3.6 8.7 5.0 2.8 RLA Volts/Hz/Ph 115/60/1 115-127/60/1 220/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 265/60/1 115-127/60/1 220/60/1 115/60/1 115/60/1 208-230/60/1 220/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 208-230/60/1 Model AEA4440YAS AEA4440YDS AEA4440YES AEA4440YXA AEA4440YXD AEA4448AXA AEA4448YXA AEA4448YXD AEA5455EXA AEA5460EXA AEA5465EXA AEA5465EXD AEA5465EXV AEA4430YDS AEA4430YES AEA4430YLS AEA4430YXA AEA4430YXD AEA4440AES AEA4440ALS AEA4440AXA AEA4440AXD AEA3448YXA AEA4430AXA AEA4430AXD

32 Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Remarks Alternate overload kit: K90-13 kit: overload Alternate Overload ~ 8300MRPG15 K90-08 K90-09 K90-09 K90-07 8300MRPJ91 83613 83974 K90-15 8300MRAN11 K90-21 8300MRPP74 8300MRTE81 83643 830-10003 8300MRAA94 8300MRAC45 K90-10 K90-10 8300MRAB59 K90-12 8300MRPP75 K90-13 8300MRPE79 Relay ~ ~ RP8102-ZR K71-09 RP6202-ZR 82403 K71-08 82404 820RR12B99 K71-01 RP15518-ZR K71-01 820RR12L30 K71-06 82462 RVA2AE3C K71-19 K71-19 K71-19 K71-19 K71-19 K71-09 K71-12 K71-09 K71-01

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 15MFD400V-R ~ K150-03 K150-03 K150-03 K150-03 ~ ~ ~ ~ Number Start Cap Part ~ ~ ~ K146-22 K146-23 ~ ~ ~ ~ K146-14 302P72-88F250 K146-14 K146-15 K146-04 ~ 21-25MFD330V-D ~ K146-56 K146-56 K146-56 K146-56 K146-17 85PS110C92 K146-17 K146-14 ~ ~ ~ ~ ~ ~ ~ 1.6 1.3 1.3 3.5 5.2 1.1 4.0 1.1 3.3 0.8 3.9 0.8 1.6 1.0 1.8 1.3 1.8 1.0 Run ~ ~ ~ ~ ~ ~ ~ 6.2 6.2 5.8 5.1 6.1 5.1 6.1 12.0 10.5 10.6 12.5 15.7 20.6 17.3 11.5 11.7 13.3 12.4 Start Winding Resistance 37.5 22.1 26.6 32.0 32.0 26.6 18.0 14.6 14.0 40.0 20.5 40.0 21.0 45.0 12.9 19.5 38.0 24.0 34.0 34.0 34.0 29.0 30.0 29.0 38.0 LRA ~ 6.2 2.2 2.8 3.8 4.2 4.0 1.8 1.7 1.3 6.1 3.3 6.7 3.4 7.4 1.0 8.3 5.2 6.0 6.2 7.0 4.3 4.2 4.5 5.4 RLA Volts/Hz/Ph 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 220/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 Model AEB3440AXA AEB1360AXA AEB1380AXA AEB1411AXA AEB1413AXA AEB3425AXA AEB1343AXA AEB1336AXA AEB1332AXA AEA5470EES AEA9422EXA AEA9422EXD AEA9422ZXA AEA9422ZXD AEA9423YXA AEB1320AXA AEA5470EXA AEA8458EXA AEA8467EXA AEA8469EXA AEA8475EXA AEA9415EXA AEA9415YXA AEA9415ZXA AEA9419YXA

33 Tecumseh Europe compressor, compressor, Europe Tecumseh available service kits shown Remarks Tested without Condenser Fan Tecumseh Europe compressor, compressor, Europe Tecumseh available service kits shown Overload ~ ~ ~ K90-18 INTERNAL INTERNAL INTERNAL ~ ~ ~ ~ ~ ~ 830-10266 K90-07 INTERNAL INTERNAL K90-11 INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ ~ K71-09 ~ K71-20 ~ ~ ~ ~ ~ ~ ~ RP7108-ZR K71-04 ~ ~ K71-04 K71-20 ~ K71-20 ~ ~ ~

Run CapRun Part Number ~ ~ ~ ~ ~ K150-17 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ K150-17 ~ ~ ~ ~ ~ Number Start Cap Part ~ ~ ~ K146-14 ~ K146-43 ~ ~ ~ ~ ~ ~ ~ 85S-10015 K146-12 ~ ~ K146-16 K146-43 ~ ~ ~ ~ ~ ~ ~ ~ 1.1 1.7 8.1 8.1 1.6 1.0 1.0 0.7 0.7 1.2 1.2 4.0 5.6 3.9 0.8 2.0 0.8 3.8 0.5 0.5 3.2 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 3.1 4.7 4.4 2.4 2.4 5.9 3.8 3.8 2.8 2.5 3.2 11.4 18.5 23.9 Start Winding Resistance ~ 47.0 31.0 24.0 12.9 18.0 21.5 20.0 32.0 34.0 30.0 45.0 30.0 90.0 30.0 60.0 40.0 93.0 93.0 46.0 38.5 LRA 115.0 115.0 103.0 7.0 3.1 6.7 4.4 2.4 6.4 5.9 5.9 6.6 3.9 4.5 6.0 5.5 8.9 5.3 3.3 3.2 17.0 10.4 14.5 13.8 13.5 22.7 22.5 RLA Volts/Hz/Ph 460/60/3 208-220/60/1 115/60/1 115/60/1 220-230/60/1 115/60/1 208-230/60/1 200-230/60/3 460/60/3 115/60/1 208-220/60/1 115/60/1 115/60/1 115/60/1 115-127/60/1 115/60/1 208-220/60/1 208-230/60/1 208-230/60/1 200-230/60/3 575/60/3 200-230/60/3 200-230/60/3 575/60/3 Model AGA4534AXG AED1413ZHZ AED1413ZXA AED2418ZXA AED4430YWZ AEZ4440Z AGA4534AXN AGA4534AXT AGA4543AXG AED2411ZXA AED2413ZHZ AED2413ZXA AED2415ZXA AED4456YXA AEX413Y-DS1B AEZ4425Z AEZ4440E AGA4543AXN AGA5546EXN AGA4543AXT AGA5546EXH AGA5546EXT AGA5549CXT AGA5553EXH

34 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay K71-20 ~ ~ ~ ~ ~ K71-20 ~ ~ ~ ~ ~ K71-20 ~ ~ ~ ~ ~ K71-20 K71-20 ~ ~ ~ K71-20 ~

Run CapRun Part Number K150-19 ~ K150-19 ~ ~ ~ K150-22 ~ K150-22 ~ ~ ~ K150-22 ~ ~ ~ ~ ~ K150-22 K150-22 ~ ~ ~ K150-15 ~ Number Start Cap Part K146-43 ~ ~ ~ ~ ~ K146-43 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ K146-43 K146-45 ~ ~ ~ K146-20 ~ ~ ~ 1.7 0.7 0.7 0.7 2.7 0.4 0.4 0.4 0.4 0.4 0.4 5.9 0.6 0.6 0.6 0.6 0.8 0.8 2.0 0.3 0.3 2.5 0.3 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.1 2.1 1.7 1.7 1.7 1.6 1.6 1.6 Start Winding Resistance 75.0 79.0 75.0 39.0 62.0 62.0 42.5 LRA 179.0 179.0 179.0 128.4 128.4 126.0 126.0 132.0 126.0 132.0 135.0 135.0 165.0 165.0 165.0 165.0 103.0 103.0 7.0 7.5 9.4 5.5 9.2 8.3 17.1 11.8 18.7 16.0 18.0 18.0 15.5 15.5 25.0 20.0 20.0 28.0 34.5 30.5 30.5 34.5 26.2 26.2 22.2 RLA Volts/Hz/Ph 208-230/60/1 200-230/60/3 208-230/60/1 200-230/60/3 575/60/3 460/60/3 208-230/60/1 200-230/60/3 208-230/60/1 200-230/60/3 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 200-230/60/3 208-230/60/1 208-230/60/1 200-230/60/3 200-230/60/3 460/60/3 440/60/3 208-230/60/1 200-230/60/3 Model AGA5553EXN AGA5553EXT AGA5553WXN AGA5553WXT AGA5561EXH AGA9530ZXG AGA5561EXN AGA5561EXT AGA5561WXN AGA5561WXT AGA5562CXT AGA5563CXG AGA5568WXN AGA5568WXT AGA5573EXG AGA5573EXH AGA5573EXT AGA9530ZXN AGA5568EXN AGA5568EXT AGA9530ZXT AGA9534ZXG AGB4537YTZ AGA9534ZXN AGA9534ZXT

35

Two (2) eaTwo req’d: Relays, Start Two (2) RelaysTwo and Start Caps required Two (2) RunTwo Caps required Two (2) RunTwo Caps required Two (2) RunTwo Caps required Two (2) eaTwo req’d: Relays, Start Remarks and Run Caps and Run Caps Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay K71-17 ~ ~ ~ ~ ~ ~ K71-24 ~ K71-21 K71-20 ~ K71-20 K71-19 K71-19 ~ K71-19 K71-20 ~ K71-19 K71-20 ~ K71-19

Run CapRun Part Number K150-06 ~ ~ ~ ~ ~ ~ ~ ~ K150-18 K150-14 ~ K150-14 K150-14 K150-14 ~ K150-14 K150-15 ~ K150-14 K150-15 ~ K150-14 Number Start Cap Part K146-05 ~ ~ ~ ~ ~ ~ K146-05 ~ K146-45 K146-45 ~ K146-45 K146-36 K146-36 ~ K146-36 K146-12 ~ K146-36 K146-12 ~ K146-36 ~ ~ ~ ~ ~ ~ ~ ~ ~ 0.4 3.4 3.8 2.9 2.5 2.0 0.6 1.6 1.6 1.6 Run 5 - 9 3 - 7 3 - 7 3 - 7 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Start 4 - 7 2 - 5 2 - 5 2 - 5 Winding Resistance 71.0 49.0 47.0 54.0 62.0 75.0 51.0 58.0 71.0 50.0 51.0 51.0 60.0 51.0 51.0 60.0 51.0 55.0 LRA 158.0 137.0 180.0 148.0 130.0 9.7 7.7 7.0 7.8 9.5 8.2 6.0 6.0 6.0 18.0 10.6 15.1 27.8 24.6 11.5 20.8 12.0 11.5 10.0 11.0 10.0 11.0 10.5 RLA Volts/Hz/Ph 208-230/60/1 200-230/60/3 575/60/3 460/60/3 460/60/3 460/60/3 460/60/3 208-230/60/1 200-230/60/3 208-230/60/1 208-230/60/1 440/60/3 208-230/60/1 208-230/60/1 208-230/60/1 200-230/60/3 208-230/60/1 265/60/1 200-230/60/3 208-230/60/1 265/60/1 200-230/60/3 208-230/60/1 Model AH2513AT AGB5561EXT AGB5568EXH AGC5546EXG AGC5553EXG AGC5561EXG AGC5568EXG AH2490AT AGB5553EXT AGB5561EXN AGB5553EXN AGB4568ZTZ AGB5546EXN AH4550AT AH5519E AH5520E AH5520E AH5520E AH5520F AH5520F AH5520F AH5522E AH5522E

36 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay K71-20 K71-19 K71-20 ~ K71-19 K71-20 K71-19 K71-20 ~ K71-20 K71-20 K71-19 K71-19 ~ K71-19 K71-20 K71-19 K71-20 K71-19 K71-20 ~ ~ K71-19 ~ ~

Run CapRun Part Number K150-15 K150-14 K150-15 ~ K150-14 K150-15 K150-14 K150-15 ~ K150-15 K150-15 K150-14 K150-14 ~ K150-14 K150-15 K150-14 K150-15 K150-14 K150-15 ~ ~ K150-14 ~ ~ Number Start Cap Part K146-12 K146-36 K146-12 ~ K146-36 K146-12 K146-36 K146-12 ~ K146-12 K146-12 K146-36 K146-36 ~ K146-36 K146-12 K146-36 K146-12 K146-36 K146-12 ~ ~ K146-36 ~ ~ ~ 1.6 1.3 1.3 1.6 6.3 1.3 5.3 Run 4 - 7 3 - 7 4 - 7 3 - 7 3 - 7 3 - 7 3 - 7 2 - 6 2 - 6 2 - 6 2 - 6 2 - 6 3 - 6 2 - 6 3 - 6 3 - 6 2 - 5 ~ ~ ~ ~ ~ ~ ~ ~ 2 - 7 2 - 5 2 - 7 2 - 5 2 - 5 2 - 5 2 - 5 1 - 5 1 - 5 2 - 5 2 - 5 2 - 5 2 - 5 2 - 5 2 - 5 2 - 5 1 - 5 Start Winding Resistance 65.0 55.0 65.0 60.0 60.0 65.0 60.0 65.0 63.4 73.0 73.0 76.0 76.0 63.4 76.0 71.0 76.0 71.0 76.0 71.0 65.1 32.8 88.0 73.4 37.7 LRA 6.5 7.6 8.2 9.7 4.8 5.3 11.5 10.5 11.5 10.4 11.5 10.4 11.5 11.5 11.5 15.0 15.0 16.5 14.4 16.5 14.4 16.5 14.4 15.8 10.8 RLA Volts/Hz/Ph 265/60/1 208-230/60/1 265/60/1 200-230/60/3 208-230/60/1 265/60/1 208-230/60/1 265/60/1 200-230/60/3 265/60/1 265/60/1 208-230/60/1 208-230/60/1 200-230/60/3 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 460/60/3 Model AH5522E AH5522F AH5522F AH5524E AH5524E AH5524E AH5524F AH5524F AH5527E AH5527E AH5527F AH5530E AH5530F AH5531E AH5531E AH5531E AH5531F AH5531F AH5533E AH5533E AH5534E AH5534E AH5534E AH5540E AH5540E

37 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay K71-20 K71-19 K71-19 K71-19 K71-19 K71-19 K71-19 K71-20 K71-19 K71-20 K71-19 K71-19 K71-20 K71-20 K71-20 K71-25 K71-24 ~ ~ K71-17 ~ K71-17 ~ ~ K71-17

Run CapRun Part Number K150-15 K150-14 K150-14 K150-15 K150-14 K150-15 K150-14 50/440 K150-14 50/440 K150-14 K150-14 50/440 K150-14 50/440 ~ ~ ~ ~ K150-06 ~ K150-06 ~ ~ K150-06 Number Start Cap Part K146-43 K146-36 K146-36 K146-12 K146-36 K146-12 K146-36 K146-12 K146-36 K146-12 K146-36 K146-36 K146-12 K146-43 K146-43 K146-05 K146-05 ~ ~ K146-20 ~ K146-07 ~ ~ K146-05 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 1.8 1.1 2.6 6.3 0.7 1.7 0.7 3.4 6.3 0.7 Run 1 - 5 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.5 2.5 3.6 3.6 3.6 Start 1 - 5 Winding Resistance 57.0 57.0 50.0 57.0 50.0 65.0 61.0 75.0 70.0 88.0 88.0 76.0 92.0 45.0 51.0 34.0 24.0 75.0 47.0 71.0 47.0 24.0 75.0 LRA 103.0 104.0 9.7 9.2 6.4 8.2 3.8 2.7 6.0 9.7 5.4 2.7 9.7 22.0 10.2 11.2 10.0 13.0 11.3 14.9 12.8 16.4 17.1 14.8 20.5 17.8 10.7 RLA Volts/Hz/Ph 208-230/60/1 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 208-230/60/3 460/60/3 230/60/1 208-230/60/1 208-230/60/1 208-230/60/3 460/60/3 230/60/1 Model AH5540E AH8524E AH8526E AH8526E AH8529E AH8529E AH8532E AH8532E AH8538E AH8538E AH8539E AH8543E AH8543E AH8548E AH8548E AHA2435AXD AHA2445AXD AHA2445AXF AHA2445AXG AHA2465ZXB AHA2465ZXF AHA2466AXD AHA2466AXF AHA2466AXG AHA2480JXB

38 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ ~ ~ K71-17 K71-19 ~ ~ K71-19 ~ ~ K71-19 ~ K71-19 ~ ~ K71-19 ~ ~ K71-19 ~ ~ K71-20 ~ ~

Run CapRun Part Number ~ ~ ~ ~ K150-14 K150-14 ~ ~ K150-14 ~ ~ K150-14 ~ K150-14 ~ ~ K150-15 ~ ~ K150-14 ~ ~ K150-15 ~ ~ Number Start Cap Part ~ ~ ~ ~ K146-05 K146-10 ~ ~ K146-36 ~ ~ K146-36 ~ K146-36 ~ ~ K146-10 ~ ~ K146-36 ~ ~ K146-43 ~ ~ ~ 1.7 0.5 1.5 6.1 1.3 2.6 6.3 1.0 1.6 6.3 1.0 1.6 0.9 1.6 6.3 0.9 1.5 6.3 0.6 1.5 6.1 0.5 1.1 4.6 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.1 3.7 3.7 3.7 3.7 2.8 3.8 2.1 Start Winding Resistance 47.0 65.0 27.0 45.0 34.0 24.0 51.0 55.5 24.0 51.0 55.5 60.0 55.5 24.0 71.0 55.5 24.0 76.0 65.0 27.0 72.0 35.0 LRA 103.0 108.0 103.0 5.6 8.1 3.8 6.2 3.6 5.0 3.2 7.0 8.0 3.8 9.2 4.5 9.8 4.9 6.2 14.2 11.4 10.0 11.0 12.2 15.0 16.5 22.5 12.5 RLA 10..0 Volts/Hz/Ph 208-230/60/1 208-230/60/1 208-230/60/1 460/60/3 230/60/1 208-230/60/1 208-230/60/1 460/60/3 208-230/60/1 208-230/60/1 460/60/3 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 460/60/3 208-230/60/1 208-230/60/1 460/60/3 208-230/60/1 208-230/60/1 460/60/3 208-230/60/1 208-230/60/1 460/60/3 Model AHA2480JXF AHA2490ZXD AHA2490ZXF AHA2490ZXG AHA2511JXB AHA4518AXD AHA4518AXF AHA4518AXG AHA4520EXD AHA4520EXF AHA4520EXG AHA4522EXD AHA4522EXF AHA4524EXD AHA4524EXF AHA4524EXG AHA4525AXD AHA4525AXF AHA4525AXG AHA4531EXD AHA4531EXF AHA4531EXG AHA4540EXD AHA4540EXF AHA4540EXG

39 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL ~ ~ ~ ~ Relay K71-19 K71-17 ~ K71-17 ~ K71-16 ~ ~ K71-19 ~ K71-19 ~ K71-20 ~ K71-20 ~ 820ARR3C44 ~ ~ K71-19 ~ ~ ~ ~ ~

Run CapRun Part Number K150-14 K150-03 ~ K150-07 ~ ~ ~ ~ K150-14 ~ K150-14 ~ K150-15 ~ K150-15 ~ K150-07 ~ ~ K150-14 ~ ~ ~ ~ ~ Number Start Cap Part K146-36 K146-43 ~ K146-43 ~ ~ ~ ~ K146-10 ~ K146-36 ~ K146-43 ~ K146-43 ~ K146-45 ~ ~ K146-10 ~ ~ ~ K146-47 K146-47 ~ ~ ~ ~ ~ 1.8 2.6 1.8 2.6 0.8 2.8 0.8 1.5 0.9 1.6 0.5 1.5 0.5 1.5 0.5 1.5 6.1 1.3 6.3 Run 2 - 6 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 4.3 4.3 3.5 3.4 3.7 2.1 2.1 2.4 3.7 1- 5 Start Winding Resistance ~ 71.0 41.0 34.0 41.0 34.0 67.4 55.5 24.0 60.0 55.5 60.0 55.0 65.0 65.0 94.8 65.0 27.0 45.0 45.0 35.0 48.0 36.0 LRA 103.0 103.0 ~ 6.5 4.2 9.0 5.7 7.8 3.9 7.3 7.5 7.0 3.8 8.6 3.4 5.6 6.4 5.9 14.4 11.7 10.4 11.5 18.4 10.4 21.0 11.0 11.4 RLA Volts/Hz/Ph 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 460/60/3 208-230/60/1 208-230/60/1 230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 460/60/3 208-230/60/1 440/60/3 115/60/1 115/60/1 115/60/1 115/60/1 Model AHA5527EXD AHA7480AXD AHA7480AXF AHA7511AXD AHA7511AXF AHA7513ZXD AHA7513ZXF AHA7513ZXG AHA7514AXD AHA7514AXF AHA7515JXB AHA7515JXF AHA7521ZXD AHA7521ZXF AHA7524JXB AHA7524ZXF AHB2511JXD AHB2511JXF AHB2511JXG AHB7511AXD AHC4518YTZ AJ1416A AJ1420E AJ2416B AJ4443A

40

Remarks 85PS330C23, 88-108/330 88-108/330 85PS330C23, Start Cap also approved Overload K90-21 K90-38 K90-31 K90-17 K90-30 K90-30 K90-09 8300CRBL10 K90-09 K90-92 K90-98 K90-35 K90-18 K90-35 K90-29 K90-34 K90-11 K90-51 K90-91 K90-51 K90-91 K90-88 K90-23 K90-36 83726 Relay K71-11 820ARR3A17 ~ K71-11 K71-13 K71-13 8200RVAL98 K71-13 820ARR3B89 K71-15 K71-29 K71-18 K71-16 K71-02 K71-19 K71-02 K71-32 K71-14 K71-11 K71-14 K71-11 K71-69 K71-16 K71-19 K71-21

Run CapRun Part Number ~ K150-03 ~ ~ K150-03 K150-03 K150-03 K150-03 K150-03 ~ ~ K150-03 K150-03 ~ K150-12 ~ ~ ~ ~ ~ ~ K150-03 K150-03 K150-06 K150-10 Number Start Cap Part K146-36 K146-23 K146-27 K146-25 K146-04 K146-04 K146-49 K146-23 K146-38 K146-14 K146-66 K146-28 K146-49 K146-52 K146-16 K146-27 K146-34 K146-03 K146-36 K146-18 K146-36 K146-13 K146-13 K146-13 K146-11 ~ 1.5 0.9 0.5 0.5 1.9 0.5 1.8 0.6 1.8 0.5 1.8 0.6 3.7 0.8 2.8 0.4 1.6 0.4 1.6 1.6 1.6 1.2 1.3 Run 6 - 9 ~ 8.2 3.1 3.1 3.5 3.1 3.4 4.2 3.1 3.7 3.8 0.6 4.8 3.1 3.1 7.1 7.1 5.1 6.1 10.0 16.1 19.6 11.6 11.6 Start 6 - 10 Winding Resistance ~ 41.8 48.0 38.2 68.0 68.0 34.0 68.0 34.0 57.0 30.0 68.4 38.7 57.0 67.0 47.0 24.0 69.0 41.8 69.0 41.8 41.0 41.0 55.0 52.0 LRA ~ 7.0 6.4 6.8 6.8 6.7 3.0 6.6 3.0 7.9 4.3 7.9 4.4 8.9 8.4 9.1 4.5 7.0 7.0 7.0 7.0 9.2 13.7 13.0 10.2 RLA Volts/Hz/Ph 208-230/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 265/60/1 Model AJ4492A AJ7465K AJA1420EXA AJA2416AXA AJA2419YXA AJA2419ZXA AJA2419ZXD AJA2424JXA AJA2424JXD AJA2425AXA AJA2425AXD AJA2425ZXA AJA2425ZXD AJA2430JXA AJA2432ZXA AJA4461AXA AJA4461AXD AJA4492AXA AJA4492AXD AJA4492YXA AJA4492YXD AJA4512AXD AJA4512YXD AJA5517EXD AJA5517EXV

41 Remarks Overload 83735 K90-34 K90-39 K90-36 83918 K90-49 K90-97 ~ ~ K90-38 K90-18 K90-38 K90-24 ~ K90-24 K90-35 570427 K90-29 K90-20 8300GB3S28 8300GB3S28 K90-48 K90-48 8300MRTH21 8300MRTH19 Relay K71-19 K71-21 K71-19 K71-21 K71-11 K71-03 K71-31 ~ K71-16 K71-13 K71-11 K71-13 K71-16 K71-16 ~ K71-16 ~ K71-19 K71-17 ~ ~ K71-30 K71-30 K71-02 ~

Run CapRun Part Number K150-07 K150-13 K150-07 K150-11 ~ ~ ~ K150-03 K150-03 K150-03 ~ K150-03 K150-18 K150-07 K150-18 K150-07 ~ K150-12 K150-03 K150-18 K150-18 K150-06 K150-06 ~ ~ Number Start Cap Part 85PS250D65 K146-11 ~ ~ K146-24 K146-52 K146-46 K146-19 K146-38 K146-04 K146-12 K146-04 K146-13 K146-09 ~ K146-09 ~ K146-16 K146-13 K146-28 K146-28 K146-42 K146-42 K146-25 K146-33 1.2 1.4 1.2 1.3 0.8 0.7 6.6 0.6 2.0 0.5 1.3 0.5 1.5 1.1 1.5 1.2 2.9 0.6 1.6 0.4 0.4 1.0 1.0 0.8 2.7 Run 5.1 5.8 5.1 6.1 8.5 2.8 2.3 2.9 3.7 3.1 6.6 3.1 2.7 2.6 2.7 2.7 2.9 2.8 8.1 1.7 1.7 4.1 4.1 4.8 21.7 Start Winding Resistance 54.0 47.0 57.0 55.0 38.2 49.5 29.0 65.0 34.0 68.0 46.0 68.0 40.6 54.0 40.6 54.0 36.0 67.0 37.0 87.0 87.0 55.0 55.0 45.0 25.0 LRA 8.8 8.2 8.8 5.0 5.1 6.4 6.9 8.9 7.8 6.9 3.9 4.7 6.5 6.5 9.5 4.8 11.2 11.6 10.0 11.2 10.1 11.6 10.0 13.0 13.0 RLA Volts/Hz/Ph 208-230/60/1 265/60/1 208-230/60/1 265/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 200-230/60/3 115/60/1 208-230/60/1 115/60/1 115/60/1 208-230/60/1 208-230/60/1 115/60/1 208-230/60/1 Model AJA5518EXD AJA5518EXV AJA5519EXD AJA5519EXV AJA6435AXA AJA7441AXA AJA7441AXD AJA7455ZXA AJA7455ZXD AJA7461YXA AJA7461YXD AJA7465AXA AJA7490ZXD AJA7494ZXD AJA8520EXD AJA9484EXD AJA9484EXT AJB2433ZXA AJB2433ZXD AJB2444ZXA AJB2444ZXA AJB2444ZXD AJB2444ZXD AJB4461AXA AJB4461AXD

42 Remarks Tecumseh Europe model CAJ2432Z, model Europe Tecumseh available service kits shown CAJ2446Z, model Europe Tecumseh available service kits shown CAJ2446Z, Model: Europe Tecumseh available service kits shown CAJ2464Z, model: Europe Tecumseh available service kits shown CAJ4461Y, model Europe Tecumseh available service kits shown TAJ4461Y model Europe Tecumseh CAJ4461Y, model Europe Tecumseh available service kits shown CAJ4476Y, model Europe Tecumseh available service kits shown CAJ4476Y, model Europe Tecumseh available service kits shown Overload 8300CRAC08 83927 K90-34 K90-31 ~ ~ K90-18 ~ K90-39 INTERNAL K90-35 K90-23 K90-40 K90-35 K90-16 INTERNAL K90-35 K90-17 K90-38 Relay ~ K71-19 K71-19 K71-21 ~ K71-16 K71-02 ~ K71-19 K71-19 K71-19 K71-17 K71-19 K71-17 K71-22 ~ K71-11 K71-31 K71-15

Run CapRun Part Number K150-07 K150-05 K150-06 K150-10 K150-03 K150-03 ~ K150-07 K150-07 K150-16 K150-13 K150-04 K150-13 K150-10 ~ ~ ~ ~ ~ Number Start Cap Part K146-11 ~ ~ K146-11 ~ ~ K146-12 ~ K146-11 K146-11 K146-14 K146-10 K146-16 K146-41 K146-39 ~ K146-27 K146-39 K146-27 ~ 1.8 1.5 1.7 0.6 2.0 1.3 1.1 1.2 2.0 0.7 1.6 0.5 1.0 2.6 0.7 2.2 0.7 Run 21.0 ~ 9.5 7.8 8.6 2.9 3.7 6.6 2.6 5.1 2.5 3.9 8.1 2.6 4.1 5.0 3.7 10.2 21.0 11.5 Start Winding Resistance 70.0 37.5 41.0 42.0 65.0 34.0 46.0 54.0 57.0 34.0 61.0 37.0 67.0 55.0 24.0 10.5 46.0 29.0 54.0 LRA 7.5 8.5 7.4 5.2 7.0 8.8 6.2 7.0 4.8 6.5 5.3 1.4 9.0 6.0 14.9 11.2 11.6 10.0 10.7 RLA Volts/Hz/Ph 115/60/1 208-230/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 265/60/1 115/60/1 208-220/60/1 115/60/1 208-220/60/1 208-220/60/1 440/60/3 115/60/1 208-220/60/1 115/60/1 Model AJB5513EXA AJB5513EXD AJB5515EXD AJB5515EXV AJB7461JXA AJB7461JXD AJB7465AXD AJB7510JXD AJC5519EXD AJD8520EXV AJE2422ZXA AJE2433ZHZ AJE2433ZXA AJE2444ZHZ AJE4461YHZ AJE4461YTZ AJE4461YXA AJE4476YHZ AJE4476YXA

43 Remarks Tecumseh Europe model CAJ4492Y, CAJ4492Y, model Europe Tecumseh available service kits shown CAJ4492Y, model Europe Tecumseh available service kits shown CAJ4511Y, model Europe Tecumseh available service kits shown TAJ4511Y model Europe Tecumseh CAJ4517Z, model Europe Tecumseh available service kits shown TAJ4517Z model Europe Tecumseh TAJ4517Z model Europe Tecumseh CAJ9513Z, model Europe Tecumseh available service kits shown CAJ9513Z, Model Europe Tecumseh available service kits shown Overload K90-19 K90-39 K90-21 INTERNAL K90-35 INTERNAL INTERNAL K90-24 K90-40 K90-124 K90-127 K90-107 K90-127 K90-128 K90-126 830-10381 K90-126 830-10381 K90-126 K90-107 Relay K71-31 K71-15 K71-20 ~ K71-20 ~ ~ K71-20 K71-19 K71-90 K71-90 K71-91 K71-90 K71-91 K71-90 ~ K71-67 ~ K71-90 K71-62

Run CapRun Part Number ~ ~ K150-04 ~ K150-10 ~ ~ K150-04 K150-13 K150-06 K150-06 K150-06 K150-06 K150-06 K150-06 K150-06 K150-06 K150-06 K150-06 K150-06 Number Start Cap Part K146-12 K146-27 K146-10 ~ K146-10 ~ ~ K146-13 K146-28 K146-49 K146-49 K146-02 K146-49 K146-02 K146-54 ~ K146-70 ~ K146-49 K146-13 ~ ~ 1.4 0.4 1.3 3.5 0.8 3.5 0.9 0.7 0.7 0.8 4.2 1.5 0.5 1.2 3.6 1.1 2.9 11.0 Run ~ ~ 6.1 2.6 5.0 4.6 4.0 4.6 4.5 4.4 4.4 4.0 4.2 3.1 6.9 3.6 6.1 2.9 11.0 10.0 Start Winding Resistance ~ 38.0 63.0 47.0 27.6 51.0 35.0 43.0 75.0 32.0 51.5 22.9 51.5 22.9 47.4 47.4 59.8 59.8 51.5 23.7 LRA 7.3 7.3 4.6 9.2 5.8 3.0 8.2 4.6 6.0 2.9 5.8 2.7 6.7 6.7 7.8 7.3 8.3 3.8 12.5 16.1 RLA Volts/Hz/Ph 208-220/60/1 115/60/1 208-220/60/1 220/60/3 208-220/60/1 220/60/3 440/60/3 208-220/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 Model AJE4492YHZ AJE4492YXA AJE4511YHZ AJE4511YKZ AJE4517ZHZ AJE4517ZKZ AJE4517ZTZ AJEK513ZHZ AJEK513ZXA AK2424U-XA3B AK2430Z-XA3B AK2430Z-XD3B AK2431U-XA3B AK2431U-XN3B AK4461V-XA3B AK4461Y-XA3B AK4468V-XA3B AK4468Y-XA3B AK4481V-XA3B AK4481V-XD3B

44 Remarks Overload 830-10381 K90-126 830-10381 K90-125 K90-125 K90-84 8300MSTH07 8300MRPT82 8300RBCT81 K90-63 K71-62 K90-35 K90-50 K90-27 K90-86 K90-27 8300MRAC75 K90-22 8300MRAD31 ~ K90-19 K90-26 K90-16 8300MRAB55 K90-25 Relay ~ K71-90 K71-67 K71-90 K71-90 K71-62 K71-19 820ARR3K53 K71-16 K71-43 K90-106 K71-02 K71-22 K71-02 K71-22 K71-11 820ARR3B09 K71-19 820ARR3H13 ~ K71-19 K71-19 K71-19 K71-19 K71-19

Run CapRun Part Number K150-06 K150-06 K150-06 K150-06 K150-06 K150-06 K150-14 K150-06 K150-03 K150-14 K150-07 ~ ~ ~ ~ ~ K150-07 K150-03 K150-03 K150-03 K150-03 K150-03 K150-03 K150-03 K150-03 Number Start Cap Part ~ K146-49 K146-27 K146-54 K146-54 K146-02 K146-41 K146-41 K146-39 K146-42 K146-41 K146-25 K146-39 K146-52 K146-37 K146-34 K146-11 ~ K146-11 K146-11 K146-11 K146-11 ~ ~ K146-56 ~ ~ ~ ~ ~ ~ ~ ~ 0.7 0.6 1.1 3.7 3.3 0.8 3.0 0.7 2.8 0.6 2.2 0.6 1.0 0.6 0.7 2.9 4.1 Run ~ ~ ~ ~ ~ ~ ~ ~ 4.4 3.9 3.4 4.7 7.5 3.2 3.4 4.6 6.2 4.2 4.7 9.9 4.2 7.8 10.2 12.1 12.4 Start Winding Resistance 51.5 51.5 59.8 58.9 58.9 36.1 30.0 20.0 20.0 40.0 27.0 48.0 23.0 58.8 27.4 59.0 29.8 35.0 22.4 19.0 58.8 43.0 21.3 22.3 46.0 LRA 8.3 8.0 9.1 6.8 4.9 2.3 2.6 6.3 3.2 9.5 4.8 5.7 6.0 7.1 3.5 3.0 9.0 4.4 3.9 11.2 12.1 11.3 12.3 11.3 10.4 RLA Volts/Hz/Ph 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 Model AK4481Y-XA3B AK4482U-XA3B AK4492U-XA3B AK4510Z-XA3B AK4511Z-XA3B AK4513Z-XD3B AKA2415ZXA AKA2415ZXD AKA2419ZXD AKA2425ZXA AKA2425ZXD AKA4460YXA AKA4460YXD AKA4476YXA AKA4476YXD AKA4482YXA AKA5460EXA AKA5470EXA AKA5470EXD AKA5470EXV AKA5470YXA AKA5483EXA AKA5483EXD AKA5483EXV AKA5494EXA

45 Remarks Overload 8300MRAC72 K90-25 K90-19 K90-14 8300MRAB63 K90-39 8300MRAC46 K90-39 K90-22 K90-18 8300MRAC75 8300MRAE77 8300MRAE78 ~ 8300MRAD64 8300MRAD96 8300MRAD97 K90-39 8300MRAC46 8300MRAF48 8300MRAD17 ~ 8300MRAF10 8300MRAD17 8300MRAC46 Relay ~ K71-19 K71-19 K71-19 ~ K71-19 82243 K71-21 K71-16 K71-21 ~ K71-19 K71-19 K71-19 ~ K71-19 K71-19 K71-19 K71-19 K71-19 K71-19 ~ ~ K71-19 K71-19

Run CapRun Part Number K150-03 K150-07 K150-03 K150-03 ~ K150-07 K150-03 K150-07 K150-03 K150-04 K150-07 K150-03 K150-03 K150-03 K150-14 K150-03 K150-03 K150-07 K150-05 K150-03 K150-03 ~ K150-07 K150-03 ~ Number Start Cap Part K146-56 ~ ~ K146-11 ~ ~ K146-39 ~ K146-11 K146-11 ~ K146-11 ~ K146-11 ~ K146-11 ~ ~ ~ ~ K146-11 ~ K146-11 K146-11 ~ ~ ~ ~ 3.9 6.1 0.8 3.3 4.2 0.7 1.8 2.7 2.8 2.4 2.7 1.8 0.7 1.9 3.0 1.7 0.7 1.8 0.5 1.7 2.4 1.3 Run ~ ~ ~ 6.5 9.2 3.2 7.5 7.8 6.0 7.1 7.2 4.5 7.1 6.2 7.2 9.6 6.0 7.2 8.8 5.3 10.4 10.4 10.2 10.4 10.2 Start Winding Resistance 26.0 47.0 28.0 27.4 34.0 50.0 31.0 62.0 34.0 33.0 29.8 15.9 12.3 35.0 40.0 20.0 16.0 50.0 31.0 26.3 26.3 53.0 31.2 26.3 31.0 LRA 5.5 5.7 5.0 6.7 6.0 6.8 5.5 5.6 2.8 2.6 6.6 7.0 3.5 3.1 8.9 4.8 3.8 4.0 9.4 4.6 4.2 5.6 10.5 11.0 12.5 RLA Volts/Hz/Ph 208-230/60/1 115/60/1 208-230/60/1 265/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 208-230/60/1 Model AKA5494EXD AKA5510EXA AKA5510EXD AKA5510EXV AKA5511CXD AKA5511EXA AKA5511EXD AKA5512EXA AKA5512EXD AKA5512EXV AKA8475EXA AKA8475EXD AKA8475EXV AKA8483EXA AKA8494EXA AKA8494EXD AKA8494EXV AKA8511EXA AKA8511EXD AKA8511EXV AKA8512CXV AKA8512EXA AKA8512EXD AKA8512EXV AKA8513CXD

46 Remarks Overload K90-39 8300MRAC46 8300MRAD17 8300CRAC05 8300MRAE61 8300MRAE57 K90-18 8300CRAC08 8300MSTE14 K90-18 K90-94 K90-100 K90-35 K90-13 K90-23 K90-23 K90-34 K90-87 K90-23 K90-19 K90-37 K90-87 K90-90 8300MRAM71 K90-20 Relay K71-19 K71-19 K71-19 820ARR3B16 ~ K71-19 K71-21 K71-19 K71-19 K71-21 K71-02 K71-32 K71-02 K71-32 K71-02 K71-02 K71-02 K71-17 K71-02 8200EMBJ93 K71-02 K71-17 K71-19 K71-17 K71-17

Run CapRun Part Number K150-07 K150-03 K150-03 K150-18 K150-07 K150-04 ~ K150-14 K150-07 K150-04 ~ ~ ~ ~ ~ ~ K150-12 K150-03 ~ ~ ~ K150-03 K150-07 K150-03 K150-03 Number Start Cap Part ~ K146-56 ~ K146-56 ~ ~ ~ ~ K146-11 K146-11 K146-25 K146-39 K146-25 K146-39 K146-25 K146-39 K146-52 K146-02 K146-52 85PS250D10 K146-52 K146-02 K146-15 K146-02 K146-02 0.7 1.8 2.7 0.7 2.4 2.8 2.4 0.5 2.2 2.4 0.7 2.8 0.7 2.8 0.7 0.7 0.6 1.8 0.6 2.2 0.6 1.8 0.7 1.8 1.8 Run 6.0 7.1 3.0 4.6 8.2 8.8 8.2 6.1 8.8 4.6 6.2 4.6 6.2 4.6 4.6 4.2 4.2 4.7 4.2 6.0 10.4 10.4 10.4 10.4 10.4 Start Winding Resistance 50.0 31.0 26.3 53.0 31.2 27.0 33.0 75.0 36.0 33.0 48.0 23.0 48.0 23.0 48.0 23.0 58.8 31.0 58.8 27.4 58.8 31.0 50.0 31.0 31.0 LRA 5.8 4.7 5.5 4.8 4.9 6.2 5.4 7.8 3.8 7.3 3.7 7.8 4.2 9.2 4.3 9.2 4.6 8.8 4.0 9.4 5.2 4.9 10.8 10.8 13.0 RLA Volts/Hz/Ph 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 208-230/60/1 Model AKA8513EXA AKA8513EXD AKA8513EXV AKA8514EXA AKA8514EXD AKA8514EXV AKA8515CXV AKA8515EXA AKA8515EXD AKA8515EXV AKA9427ZXA AKA9427ZXD AKA9428EXA AKA9428EXD AKA9434AXA AKA9434AXD AKA9438ZXA AKA9438ZXD AKA9441AXA AKA9441AXD AKA9442EXA AKA9442EXD AKA9451ZXA AKA9451ZXD AKA9455EXD

47 Remarks Overload K90-27 K90-20 K90-27 K90-16 K90-20 K90-40 K90-84 8300MRAG76 K90-20 K90-40 K90-22 K90-27 INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay K71-19 K71-17 K71-19 K71-17 K71-17 K71-19 K71-69 K71-19 K71-17 K71-16 K71-16 820ARR3K56 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

Run CapRun Part Number K150-07 K150-03 K150-07 K150-03 K150-03 K150-07 K150-03 ~ K150-03 K150-07 K150-03 K150-03 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part K146-15 K146-02 K146-15 K146-39 K146-02 K146-15 K146-02 ~ K146-39 K146-39 K146-15 K146-38 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 0.7 1.8 0.7 1.8 1.8 0.4 1.7 0.7 1.8 0.5 1.7 0.7 1.4 0.3 1.3 0.3 0.9 1.6 0.3 0.8 1.3 0.2 1.4 0.3 1.3 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 6.0 6.0 7.1 6.0 7.1 6.7 10.4 10.4 10.4 10.2 10.4 10.2 Start Winding Resistance 50.0 31.0 50.0 31.0 31.0 68.0 34.0 50.0 31.0 68.0 34.0 43.5 86.1 93.3 91.0 99.0 86.1 93.3 LRA 172.0 183.0 116.0 229.0 135.0 269.0 172.0 5.7 9.3 5.2 5.3 6.8 5.9 6.8 10.1 11.9 10.4 12.2 10.0 13.7 27.0 14.4 29.0 17.8 14.5 36.0 20.8 15.8 42.0 13.7 27.0 14.4 RLA Volts/Hz/Ph 115/60/1 208-230/60/1 115/60/1 208-230/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 460/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 Model AKA9455ZXA AKA9455ZXD AKA9458JXA AKA9458JXD AKA9462EXD AKA9462ZXA AKA9462ZXD AKA9466JXA AKA9466JXD AKA9474JXA AKA9474JXD AKB4476YXA ANA5590EXG ANA5590EXT ANA5610EXG ANA5610EXT ANA5612EXG ANA5612EXH ANA5612EXT ANA5614EXG ANA5614EXH ANA5614EXT ANB5590EXG ANB5590EXT ANB5610EXG

48 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 0.3 0.9 1.6 0.3 0.8 1.3 0.2 1.4 0.3 1.3 0.3 0.9 1.6 0.3 0.8 1.3 0.2 1.4 0.3 1.3 0.3 0.9 1.6 0.3 0.8 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Start Winding Resistance 91.0 99.0 86.1 93.3 91.0 99.0 86.1 93.3 91.0 LRA 183.0 116.0 229.0 135.0 269.0 172.0 183.0 116.0 229.0 135.0 269.0 172.0 183.0 116.0 229.0 135.0 29.0 17.8 14.5 36.0 20.8 15.8 42.0 13.7 27.0 14.4 29.0 17.8 14.5 36.0 20.8 15.8 42.0 13.7 27.0 14.4 29.0 17.8 14.5 36.0 20.8 RLA Volts/Hz/Ph 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 Model ANB5610EXT ANB5612EXG ANB5612EXH ANB5612EXT ANB5614EXG ANB5614EXH ANB5614EXT ANC5590EXG ANC5590EXT ANC5610EXG ANC5610EXT ANC5612EXG ANC5612EXH ANC5612EXT ANC5614EXG ANC5614EXH ANC5614EXT AND5590EXG AND5590EXT AND5610EXG AND5610EXT AND5612EXG AND5612EXH AND5612EXT AND5614EXG

49 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ ~ K71-20 ~ ~ K71-20 ~ K71-20 ~ K71-20 ~ K71-19 ~ K71-20 ~ ~ K71-20 ~ K71-20 ~ K71-20 ~ ~ ~

Run CapRun Part Number ~ ~ ~ K150-19 ~ ~ K150-19 ~ K150-17 ~ K150-14 ~ K150-15 ~ K150-16 ~ ~ K150-15 ~ ~ ~ K150-15 ~ ~ ~ Number Start Cap Part ~ ~ ~ K146-44 ~ ~ K146-45 ~ K146-43 ~ K146-43 ~ ~ ~ K146-43 ~ ~ K146-02 ~ ~ ~ ~ ~ ~ ~ ~ 1.3 0.2 3.4 0.5 1.6 3.4 0.4 1.6 0.6 6.2 0.8 1.6 1.0 6.2 0.6 1.6 5.2 0.6 1.4 0.8 5.2 0.6 1.4 5.2 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 1.8 1.7 2.2 2.8 3.0 2.7 3.4 3.2 3.4 Start Winding Resistance 99.0 38.3 65.1 38.3 65.1 32.8 78.0 59.5 73.8 32.8 88.0 65.1 37.7 95.0 73.4 86.3 37.7 95.0 73.4 74.0 37.0 LRA 269.0 106.6 120.3 108.0 3.6 7.4 4.6 9.3 4.4 8.9 4.8 9.7 5.3 5.3 6.0 15.8 42.0 11.4 16.9 19.7 14.5 12.2 15.8 17.2 10.8 14.6 17.2 10.8 11.3 RLA Volts/Hz/Ph 575/60/3 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 208-230/60/1 460/60/3 208-230/60/1 200-230/60/3 265/60/1 460/60/3 208-230/60/1 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 265/60/1 460/60/3 208-230/60/1 200-230/60/3 200-230/60/3 460/60/3 Model AND5614EXH AND5614EXT AVA2490ZXG AVA2490ZXN AVA2490ZXT AVA2512ZXG AVA2512ZXN AVA2512ZXT AVA4542EXN AVA5532EXG AVA5532EXN AVA5532EXT AVA5532EXV AVA5535EXG AVA5535EXN AVA5535EXT AVA5538EXG AVA5538EXN AVA5538EXT AVA5538EXV AVA5538WXG AVA5538WXN AVA5538WXT AVA5539CXT AVA5542EXG

50 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay K71-20 ~ ~ ~ ~ ~ K71-20 ~ ~ ~ ~ ~ K71-20 ~ ~ ~ ~ ~ K71-20 ~ ~ K71-20 ~ ~ K71-63

Run CapRun Part Number K150-17 ~ ~ ~ ~ ~ K150-17 ~ ~ ~ ~ ~ K150-19 ~ ~ K150-19 ~ ~ K150-15 ~ ~ K150-19 ~ ~ K150-23 Number Start Cap Part K146-43 ~ ~ ~ ~ ~ K146-43 ~ ~ ~ ~ ~ K146-43 ~ ~ ~ ~ ~ K146-13 ~ ~ K146-44 ~ ~ K146-44 ~ 0.6 1.3 5.2 1.3 4.4 0.5 1.1 0.7 2.8 0.7 3.4 0.5 1.6 3.4 0.4 0.9 5.2 0.6 1.4 5.2 0.6 1.3 2.8 0.3 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.2 2.5 2.1 1.8 1.7 3.4 2.2 1.3 Start Winding Resistance 74.0 95.2 37.0 74.0 46.0 92.0 55.0 38.3 65.1 38.3 75.0 37.7 95.0 73.4 37.0 74.0 55.0 LRA 108.0 116.0 102.0 110.0 106.6 120.3 108.0 132.0 6.0 6.6 7.8 5.1 6.2 4.6 9.4 5.1 6.6 19.7 12.0 16.0 12.0 21.5 13.3 18.2 15.7 16.7 10.9 22.2 12.2 14.5 17.0 10.3 20.0 RLA Volts/Hz/Ph 208-230/60/1 200-230/60/3 265/60/1 460/60/3 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 265/60/1 460/60/3 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 460/60/3 208-230/60/1 Model AVA5542EXN AVA5542EXT AVA5542EXV AVA5542WXG AVA5542WXT AVA5546EXG AVA5546EXN AVA5546EXT AVA5546EXV AVA5555EXG AVA5555EXT AVA7524ZXG AVA7524ZXN AVA7524ZXT AVA7528ZXG AVA7528ZXN AVA7528ZXT AVA9519ZXG AVA9519ZXN AVA9519ZXT AVA9522ZXG AVA9522ZXN AVA9522ZXT AVA9528ZXG AVA9528ZXN

51 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ ~ K71-19 ~ ~ ~ K71-19 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ K71-20 ~ ~ ~ K71-20 ~

Run CapRun Part Number ~ ~ ~ K150-18 ~ ~ ~ K150-18 ~ ~ ~ K150-19 ~ ~ ~ K150-19 ~ ~ ~ K150-19 ~ ~ ~ K150-19 ~ Number Start Cap Part ~ ~ ~ K146-12 ~ ~ ~ K146-13 ~ ~ ~ ~ ~ ~ ~ K146-43 ~ ~ ~ K146-43 ~ ~ ~ K146-43 ~ 0.7 6.2 0.7 1.6 6.2 8.2 0.6 1.6 5.2 8.2 0.6 1.3 5.2 8.2 0.5 1.3 4.3 4.1 0.5 1.1 3.3 4.1 0.4 0.8 10.2 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 1.4 1.5 1.7 1.7 1.8 1.7 Start Winding Resistance 32.8 26.0 78.8 65.1 32.8 31.0 86.7 65.1 37.7 31.0 97.6 73.4 37.0 31.0 73.4 46.0 44.0 92.0 55.0 44.0 LRA 110.0 107.4 110.0 141.0 110.0 4.6 3.5 8.9 4.6 4.0 9.2 5.2 4.2 5.7 4.6 6.7 5.4 7.8 6.3 13.3 13.5 14.2 15.4 10.3 17.1 11.3 20.5 13.5 24.8 15.7 RLA Volts/Hz/Ph 200-230/60/3 460/60/3 575/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 208-230/60/1 200-230/60/3 Model AVA9528ZXT AVB5533EXG AVB5533EXH AVB5533EXN AVB5533EXT AVB5535EXG AVB5535EXH AVB5535EXN AVB5535EXT AVB5538EXG AVB5538EXH AVB5538EXN AVB5538EXT AVB5542EXG AVB5542EXH AVB5542EXN AVB5542EXT AVB5549EXG AVB5549EXH AVB5549EXN AVB5549EXT AVB5558EXG AVB5558EXH AVB5558EXN AVB5558EXT

52 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay K71-19 K71-19 ~ ~ K71-20 K71-19 ~ ~ ~ K71-19 ~ ~ ~ ~ K71-19 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

Run CapRun Part Number K150-18 K150-18 K150-19 ~ K150-19 K150-18 ~ K150-18 ~ K150-18 ~ ~ K150-18 ~ 50/440 ~ ~ K150-21 ~ ~ ~ K150-21 ~ ~ ~ Number Start Cap Part K146-12 ~ K146-43 ~ K146-43 K146-44 ~ ~ ~ K146-45 ~ ~ ~ ~ K146-45 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 0.7 0.6 0.6 0.5 0.5 0.6 3.4 0.5 0.9 0.5 3.1 4.5 0.5 0.8 0.4 2.9 4.5 0.4 0.7 2.4 4.5 0.4 0.6 1.9 3.0 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 1.4 1.5 1.7 1.7 1.8 1.3 1.3 1.3 1.3 1.3 1.3 1.3 Start Winding Resistance 78.8 86.7 97.6 76.0 37.5 92.0 75.0 92.0 42.0 35.0 92.0 84.0 46.0 37.0 90.0 52.5 44.0 63.0 55.5 LRA 107.4 110.0 110.0 110.0 110.0 105.0 4.4 8.8 5.0 4.0 5.8 4.7 6.2 5.0 8.0 6.1 13.4 14.9 16.5 18.3 20.4 13.2 13.8 15.1 16.2 10.0 16.9 18.2 11.5 19.2 12.3 RLA Volts/Hz/Ph 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 460/60/3 208-230/60/1 200-230/60/3 208-230/60/1 460/60/3 575/60/3 208-230/60/1 200-230/60/3 208-230/60/1 460/60/3 575/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 Model AVC5532EXN AVC5535EXN AVC5538EXN AVC5542EXN AVC5546EXN AVD5533EXN AVD5535EXG AVD5535EXN AVD5535EXT AVD5538EXN AVD5540EXG AVD5540EXH AVD5540EXN AVD5540EXT AVD5542EXN AVD5545EXG AVD5545EXH AVD5545EXN AVD5545EXT AVD5548EXG AVD5548EXH AVD5548EXN AVD5548EXT AVD5558EXG AVD5558EXH

53 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ K71-19 ~ ~ K71-16 ~ K71-19 ~ ~ ~ K71-19 ~ K71-19 K71-19 K71-19 K71-19 K71-19 K71-19 ~ K71-19 K71-16 K71-19 ~ K71-20

Run CapRun Part Number K150-24 ~ K150-14 ~ ~ 85PR370F23 ~ K150-18 ~ ~ ~ K150-17 ~ K150-06 K150-11 K150-07 K150-11 K150-07 K150-11 K150-18 K150-18 K150-07 K150-14 ~ K150-15 Number Start Cap Part ~ ~ K146-44 ~ ~ K146-43 ~ K146-44 ~ ~ ~ K146-45 ~ K146-44 K146-12 K146-11 K146-12 K146-44 K146-12 ~ K146-12 K146-43 K146-43 ~ K146-41 ~ ~ ~ ~ ~ ~ 0.4 0.5 0.9 8.7 2.3 1.1 2.3 0.7 5.1 1.3 5.1 0.8 1.3 1.5 0.8 1.3 0.9 1.3 0.6 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 1.2 2.1 3.3 2.2 2.4 4.7 1.6 2.7 2.1 3.3 Start Winding Resistance ~ 73.0 20.3 40.5 56.0 40.5 86.0 36.0 63.4 36.0 73.1 63.4 43.0 39.5 43.0 45.0 52.0 45.0 69.4 52.0 73.0 63.4 96.8 LRA 123.0 128.0 ~ 5.1 1.8 3.8 5.9 4.2 8.2 2.9 5.6 3.1 8.4 6.2 7.2 6.1 7.6 6.6 8.4 4.3 7.4 9.6 8.0 24.0 15.9 11.4 12.5 RLA Volts/Hz/Ph 208-230/60/1 200-230/60/3 208-230/60/1 460/60/3 200-230/60/3 208-230/60/1 200-230/60/3 208-230/60/1 460/60/3 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 200-230/60/3 208-230/60/1 Model AVD5558EXN AVD5558EXT AWA2440ZXD AWA2440ZXG AWA2440ZXT AWA2450ZXD AWA2450ZXT AWA2460ZXD AWA2460ZXG AWA2460ZXT AWA2480ZXG AWA2480ZXN AWA2480ZXT AWA5515EXD AWA5515EXV AWA5517EXD AWA5517EXV AWA5519EXD AWA5519EXV AWA5528CXN AWA5530EXD AWA7490ZXD AWA7512ZXD AWA7512ZXT AWA7515ZXD

54 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ K71-16 ~ K71-62 ~ ~ K71-19 ~ K71-19 ~ K71-19 ~ K71-19 K71-19 K71-21 K71-19 K71-21 K71-21 K71-19 K71-21 K71-19 K71-21 K71-19 K71-19 K71-21

Run CapRun Part Number ~ K150-07 ~ K150-14 ~ ~ K150-14 ~ K150-14 ~ K150-18 ~ K150-18 K150-07 K150-11 K150-07 K150-11 K150-14 K150-11 K150-14 K150-11 K150-14 K150-15 K150-14 K150-14 Number Start Cap Part ~ 85PS330D16 ~ K146-44 ~ ~ K146-43 ~ ~ ~ K146-44 ~ ~ K146-11 K146-12 K146-11 K146-12 K146-44 K146-39 K146-44 K146-39 K146-44 K146-39 K146-12 K146-44 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 1.3 1.3 6.5 1.3 1.6 8.7 1.1 1.6 0.9 0.7 1.3 0.6 1.0 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.7 2.7 2.5 2.1 2.1 1.6 2.4 Start Winding Resistance ~ 63.4 52.0 25.0 52.0 51.0 20.3 60.0 50.0 73.0 36.0 90.0 63.4 84.0 49.0 46.5 49.0 46.5 49.0 41.0 49.0 41.0 49.0 47.0 60.7 LRA ~ 7.7 6.5 2.4 7.5 4.7 2.8 8.9 5.5 3.6 7.3 7.2 6.4 8.1 7.1 6.4 5.6 6.8 6.0 8.0 7.1 9.8 10.6 12.0 13.1 RLA Volts/Hz/Ph 200-230/60/3 208-230/60/1 460/60/3 208-230/60/1 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 208-230/60/1 460/60/3 208-230/60/1 200-230/60/3 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 Model AWA7515ZXT AWA9480ZXN AWA9490ZXG AWA9490ZXN AWA9490ZXT AWA9512ZXG AWA9512ZXN AWA9512ZXT AWA9513ZXD AWA9514ZXG AWA9514ZXN AWA9514ZXT AWA9518ZXN AWB5517EXD AWB5517EXV AWB5519EXD AWB5519EXV AWC5515EXD AWC5515EXV AWC5517EXD AWC5517EXV AWC5519EXD AWC5519EXV AWC5522EXD AWC5524EXD

55 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay K71-19 K71-19 ~ K71-19 K71-19 ~ K71-19 K71-19 K71-19 K71-19 ~ ~ K71-21 ~ ~ ~ ~ ~ K71-19 K71-21 ~ K71-19 ~ 820ARR3G70 ~

Run CapRun Part Number K150-14 K150-14 K150-11 K150-14 K150-14 K150-15 K150-14 K150-15 K150-14 K150-14 K150-15 ~ K150-14 ~ K150-15 ~ K150-14 ~ K150-18 K150-15 ~ K150-18 ~ K150-19 ~ Number Start Cap Part K146-12 K146-12 ~ K146-13 K146-13 K146-13 K146-12 ~ K146-13 K146-12 K146-13 ~ K146-44 ~ ~ ~ K146-44 ~ K146-44 K146-13 ~ K146-44 ~ K146-12 ~ ~ ~ 1.8 1.2 1.2 1.5 1.2 1.5 1.2 1.2 1.2 6.5 1.0 1.6 1.2 6.5 1.0 1.6 0.8 1.0 5.1 0.8 1.3 0.8 5.1 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.8 2.5 2.5 3.0 2.5 3.0 2.5 2.5 2.9 2.5 2.9 2.4 1.6 3.2 1.6 2.5 Start Winding Resistance 48.3 48.3 41.0 48.3 48.3 47.0 48.3 47.0 48.3 48.3 58.0 25.0 60.0 50.0 58.0 25.0 60.0 50.0 69.4 65.0 36.0 69.4 63.4 83.0 36.0 LRA 6.5 7.1 5.8 6.6 6.7 6.7 7.1 7.0 7.7 8.3 7.8 2.9 9.0 5.6 8.9 3.3 6.5 3.8 7.6 4.1 10.0 10.9 10.5 11.4 12.0 RLA Volts/Hz/Ph 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 265/60/1 460/60/3 208-230/60/1 200-230/60/3 265/60/1 460/60/3 208-230/60/1 200-230/60/3 208-230/60/1 265/60/1 460/60/3 208-230/60/1 200-230/60/3 265/60/1 460/60/3 Model AWD5516EXD AWD5517EXD AWF5516EVA AWF5516EXN AWF5517EXN AWF5518EVA AWF5518EXN AWF5519EVA AWF5519EXN AWF5520EXN AWF5522EVA AWF5522EXG AWF5522EXN AWF5522EXT AWF5524EVA AWF5524EXG AWF5524EXN AWF5524EXT AWF5526EXN AWF5528EVA AWF5528EXG AWF5528EXN AWF5528EXT AWF5530EVA AWF5530EXG

56 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay K71-19 ~ 820ARR3G70 ~ K71-19 ~ 820ARR3G70 K71-19 ~ ~ K71-16 ~ K71-19 ~ K71-19 ~ K71-19 K71-64 ~ ~ K71-19 K71-62 ~ K71-16 ~

Run CapRun Part Number K150-18 ~ K150-19 ~ K150-18 ~ K150-19 K150-18 ~ ~ K150-07 ~ K150-14 ~ K150-18 ~ K150-10 K150-06 ~ K150-11 K150-07 K150-07 K150-11 K150-07 K150-11 Number Start Cap Part K146-44 ~ K146-12 ~ K146-44 ~ K146-12 K146-44 ~ ~ K146-44 ~ K146-13 ~ K146-44 ~ ~ K146-44 ~ K146-13 ~ K146-44 ~ K146-44 ~ ~ ~ ~ 0.7 1.3 0.8 5.1 0.7 1.3 0.8 0.7 6.5 1.3 6.5 1.1 0.7 1.5 1.8 1.5 1.6 1.7 1.6 1.7 1.3 1.4 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ 1.6 2.5 1.6 2.5 1.6 2.7 2.5 2.1 4.7 6.5 4.7 5.3 4.0 5.3 2.7 4.7 Start Winding Resistance 84.0 63.4 83.0 36.0 84.0 63.4 83.0 84.0 25.0 25.0 52.0 25.0 60.0 36.0 90.0 43.0 39.0 43.0 51.0 45.0 43.0 52.0 45.0 52.0 51.0 LRA 8.2 4.3 8.6 2.4 2.9 9.3 3.4 4.2 6.7 6.2 6.9 4.7 6.8 7.6 8.7 7.5 8.6 8.0 12.5 12.0 13.4 13.2 13.8 11.0 14.4 RLA Volts/Hz/Ph 208-230/60/1 200-230/60/3 265/60/1 460/60/3 208-230/60/1 200-230/60/3 265/60/1 208-230/60/1 460/60/3 460/60/3 208-230/60/1 460/60/3 208-230/60/1 460/60/3 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 200-230/60/3 265/60/1 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 Model AWF5530EXN AWF5530EXT AWF5532EVA AWF5532EXG AWF5532EXN AWF5532EXT AWF5533EVA AWF5533EXN AWG4515EXG AWG4520EXG AWG4520EXN AWG4524EXG AWG4524EXN AWG4530EXG AWG4530EXN AWG5514CXN AWG5515EVA AWG5515EXN AWG5515EXT AWG5517EVA AWG5517EXN AWG5518CXN AWG5519EVA AWG5519EXN AWG5520EVA

57 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ K71-16 ~ ~ ~ ~ ~ ~ K71-19 ~ ~ K71-19 ~ ~ ~ ~ K71-33 K71-21 K71-19 ~ ~ K71-19 ~ ~ ~

Run CapRun Part Number ~ K150-07 ~ ~ K150-07 ~ ~ K150-11 K150-07 K150-15 ~ K150-14 ~ ~ K150-14 ~ K150-18 K150-15 K150-14 K150-18 K150-19 K150-18 ~ K150-18 ~ Number Start Cap Part ~ K146-44 ~ ~ ~ ~ ~ ~ 85PS330C23 K146-13 ~ K146-13 ~ ~ ~ ~ K146-43 ~ K146-13 K146-59 ~ K146-44 ~ ~ ~ ~ 6.5 1.3 1.6 6.5 1.3 1.6 1.6 1.4 1.1 1.4 6.5 1.1 1.6 6.5 1.1 1.6 0.8 1.2 0.9 0.8 0.8 0.7 1.3 1.3 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.7 2.7 4.7 2.9 3.0 2.5 2.5 2.5 2.6 2.1 2.5 2.5 2.1 Start Winding Resistance 25.0 52.0 51.0 25.0 52.0 51.0 50.0 51.0 60.0 54.0 25.0 60.0 50.0 25.0 60.0 50.0 70.0 65.0 73.0 70.0 83.0 90.0 63.4 70.0 63.4 LRA ~ 2.9 9.3 5.8 2.9 9.3 5.8 8.6 9.5 3.4 6.7 3.4 6.7 8.4 8.4 10.1 11.0 11.0 12.5 10.9 13.0 12.5 11.7 14.4 14.4 RLA Volts/Hz/Ph 460/60/3 208-230/60/1 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 200-230/60/3 265/60/1 208-230/60/1 265/60/1 460/60/3 208-230/60/1 200-230/60/3 460/60/3 208-230/60/1 200-230/60/3 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 200-230/60/3 208-230/60/1 200-230/60/3 Model AWG5520EXG AWG5520EXN AWG5520EXT AWG5520WXG AWG5520WXN AWG5520WXT AWG5521CXT AWG5522EVA AWG5522EXN AWG5524EVA AWG5524EXG AWG5524EXN AWG5524EXT AWG5524WXG AWG5524WXN AWG5524WXT AWG5526CXN AWG5528EVA AWG5528EXN AWG5530CXN AWG5530EVA AWG5530EXN AWG5530EXT AWG5530WXN AWG5530WXT

58 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ K71-19 ~ 82765 K71-19 K71-19 K71-19 82765 K71-19 K71-16 K71-20 820ARR3G70 K71-19 K71-21 K71-19 ~ K71-19 ~ ~ ~ ~ ~ ~ ~ ~

Run CapRun Part Number K150-19 K150-18 ~ K150-06 K150-06 ~ K150-06 K150-06 K150-07 K150-07 K150-11 K150-15 K150-14 K150-15 K150-14 K150-19 K150-18 ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part ~ K146-44 ~ K146-44 ~ ~ K146-11 K146-44 K146-11 ~ K146-12 K146-12 ~ K146-12 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 0.8 0.7 1.3 1.5 1.5 1.1 1.8 1.5 1.6 1.3 1.4 1.4 1.1 1.2 0.9 0.8 0.7 1.3 1.0 0.9 0.9 0.7 0.6 0.6 0.6 Run ~ 3.0 2.5 2.6 2.1 2.5 2.1 4.1 2.8 2.8 2.8 2.4 2.2 2.2 2.3 2.5 2.1 4.7 4.7 2.9 6.5 4.7 4.0 2.7 4.7 Start Winding Resistance 83.0 90.0 63.4 43.0 43.0 60.0 39.0 43.0 43.0 52.0 51.0 54.0 60.0 65.0 73.0 83.0 90.0 43.0 52.0 60.0 60.0 73.0 85.0 90.0 96.0 LRA 9.0 6.1 7.0 6.2 6.9 7.6 9.7 8.8 9.5 7.0 9.7 12.5 15.1 10.0 11.0 10.9 13.0 12.8 15.6 10.0 11.0 13.0 13.2 14.5 15.4 RLA Volts/Hz/Ph 265/60/1 208-230/60/1 200-230/60/3 208-230/60/1 208-230/60/1 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 208-230/60/1 265/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Model AWG5532EVA AWG5532EXN AWG5532EXT AWH5513EXN AWH5516EXN AWH5522EXN AWJ5515EVA AWJ5515EXN AWJ5517EXN AWJ5520EXN AWJ5522EVA AWJ5524EVA AWJ5524EXN AWJ5528EVA AWJ5528EXN AWJ5532EVA AWJ5532EXN AWZ5516EXN AWZ5520EXN AWZ5522EXN AWZ5524EXN AWZ5528EXN AWZ5530EXN AWZ5532EXN AWZ5535EXN

59 Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Tested without Condenser Fan Remarks Overload ~ ~ ~ ~ ~ K90-06 MRP61AMK-5587 8300MRPG06 8300MRPG04 ~ T0926-23-ZP 8300MRPG04 K90-06 T8826-24-ZP ~ ~ K90-04 ~ ~ 8300MRPH91 INTERNAL INTERNAL 8300MRPH38 ~ Relay ~ ~ ~ ~ ~ K71-08 RP13502-ZR 82451 82461 RP4815-ZR RP4815-ZR 82402 K71-08 820-10080 ~ ~ K71-07 ~ ~ 820RR12C20 ~ K71-21 8209660H15 ~

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ K150-19 ~ ~ Number Start Cap Part ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ K146-25 ~ ~ ~ 302P130-156J110 ~ ~ ~ ~ K146-44 ~ ~ ~ 2.7 3.8 5.2 8.0 9.9 2.7 5.1 3.8 8.0 6.5 6.5 2.3 2.3 8.7 3.1 3.7 4.4 4.5 0.5 8.1 8.0 10.2 Run 28.0 ~ ~ 9.6 9.6 9.7 9.8 2.3 14.8 14.1 15.4 25.3 14.0 12.3 15.7 34.6 34.6 23.2 34.3 12.8 13.6 14.5 14.5 15.4 15.3 Start Winding Resistance 8.4 8.4 18.8 15.9 13.2 10.9 18.8 13.2 15.9 10.9 16.5 16.5 28.0 13.2 25.3 18.5 18.5 16.3 13.6 13.6 10.2 10.2 LRA 110.0 100.0 1.9 1.5 1.2 1.0 0.8 1.9 1.2 1.5 1.0 2.0 2.0 0.8 2.9 1.6 2.9 2.1 2.2 1.9 1.6 1.6 1.2 1.1 18.3 18.5 RLA Volts/Hz/Ph 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 220/60/1 220/60/1 115/60/1 115/60/1 220/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 208-230/60/1 115/60/1 115/60/1 Model AZB1355AXA AZB1340AXA AZB1335AXA AZB1328AXA AZB1320AXA AZA1350YXA AZA1332YXA AZA1338YXA AZA1326YXA AZA0413YES AZA0413YES AZA1316YXA AZA0395YXA AZA0395YXP AZA0411AXA AZA0387AXA AZA0370YXA AZA0374AXA AZA0360AXA AZA0349YXA AWZ5538EXN AWZ5542EXN AZA0335YXA AZA0345AXA

60 Tecumseh Europe compressor, compressor, Europe Tecumseh available service kits shown Tecumseh Europe compressor, compressor, Europe Tecumseh available service kits shown Tecumseh Europe compressor, compressor, Europe Tecumseh available service kits shown Tecumseh Europe compressor, compressor, Europe Tecumseh available service kits shown Tecumseh Europe compressor, compressor, Europe Tecumseh available service kits shown Tecumseh Europe compressor, compressor, Europe Tecumseh available service kits shown Tecumseh Europe compressor, compressor, Europe Tecumseh available service kits shown Tecumseh Europe compressor, compressor, Europe Tecumseh available service kits shown Tecumseh Europe compressor, compressor, Europe Tecumseh available service kits shown Remarks Overload K90-39 K90-40 K90-39 8308347A15 K90-21 8308347A15 K90-35 8308347A15 K90-35 8308347A15 K90-34 83749 K90-23 83749 K90-21 83749 83749 8300MRAN19 Relay K71-19 K71-19 K71-21 K71-20 K71-20 K71-20 K71-17 K71-20 K71-14 K71-20 K71-18 K71-20 K71-06 K71-20 K71-01 K71-20 K71-20 K71-19

Run CapRun Part Number K150-13 K150-13 K150-15 K150-15 K150-04 K150-15 K150-10 K150-17 K150-13 K150-17 ~ K150-19 ~ K150-19 ~ K150-22 K150-22 K150-08 Number Start Cap Part K146-16 K146-16 K146-12 135-155/330 K146-12 135-155/330 K146-42 135-155/330 K146-14 K146-39 K146-16 135-155/330 K146-14 K146-39 K146-14 135-155/330 K146-39 K146-12 ~ ~ ~ ~ ~ ~ ~ ~ 0.6 0.5 0.8 1.2 1.0 0.6 0.6 0.8 0.8 1.1 Run ~ ~ ~ ~ ~ ~ ~ ~ 3.6 6.9 4.1 3.7 4.3 3.8 3.1 2.5 4.1 3.6 Start Winding Resistance 64.0 60.0 92.5 52.0 92.5 47.0 55.0 58.0 51.0 43.5 37.5 36.2 LRA 115.0 115.0 140.0 140.0 147.0 175.0 7.3 6.5 6.9 7.6 9.0 6.7 4.8 13.9 12.3 20.0 10.8 22.0 23.0 23.0 27.0 27.0 34.0 36.0 RLA Volts/Hz/Ph 115/60/1 208-220/60/1 208-230/60/1 115/60/1 230/60/1 208-220/60/1 208-230/60/1 208-220/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 Model CAJ9510Z CAJ9519Z CL5538E CAJ9480Z CL5540E CAJ4511Y CL5544E CAJ2464Z CL5544F CAJ2432Z CL5550E CAJ2428Z CL5550G CAE4456Y CL5562E CAE2420Z CL5562G HGA0440EXA

61 Remarks Overload 8300MRAN94 K90-27 ~ 14945125 8300MRAU04 MRT16ADZ-118 MRA5731-114 MSP00AMZ-113 MSP18APZ-114 ~ MRA5731-114 MSP00AMZ-113 MRA5731-114 MRA5742-114 MRA5754-114 MRA5805-113 MST22ALZ-114 MSP18APZ-114 MRA5805-113 8300MRAT71 MSP18APZ-114 K90-24 MRA3711-114 MRA5753-114 8300MSTT78 Relay K71-19 K71-19 K71-16 ~ 820ARR3K63 ~ ~ ~ ~ ~ ~ ~ K71-19 K71-16 ~ ~ ~ ~ ~ ~ ~ K71-19 K71-16 ~ ~

Run CapRun Part Number K150-08 K150-14 ~ K150-08 K150-06 K150-08 ~ ~ ~ ~ ~ ~ K150-08 K150-03 K150-03 ~ ~ ~ K150-08 K150-04 ~ 545107 K150-03 ~ K150-06 Number Start Cap Part K146-12 K146-12 ~ K146-54 K146-12 K146-54 ~ ~ ~ ~ ~ ~ K146-13 K146-13 ~ ~ ~ ~ K146-13 K146-13 ~ ~ K146-13 ~ ~ ~ ~ ~ ~ 0.7 0.6 2.3 2.9 1.0 4.2 5.3 1.0 4.1 1.0 4.1 0.7 3.0 4.3 0.7 3.0 4.3 0.7 3.0 4.3 2.3 Run ~ ~ ~ ~ 6.6 3.5 7.4 3.5 7.4 3.5 7.4 5.9 3.8 4.0 5.9 5.9 3.6 6.6 6.8 3.6 6.6 3.6 10.7 10.7 10.7 Start Winding Resistance 45.6 58.4 27.9 46.5 23.0 58.7 36.2 17.7 13.5 36.2 36.2 17.7 36.2 17.7 15.0 45.6 22.2 18.8 45.6 22.2 17.5 45.6 22.2 18.8 27.9 LRA ~ 6.2 4.1 6.0 2.9 8.4 5.0 2.5 2.1 5.7 3.1 5.6 2.8 2.4 7.0 3.4 2.9 7.7 3.6 3.4 7.0 3.5 2.9 3.6 10.2 RLA Volts/Hz/Ph 115/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 208-230/60/1 Model HGA0450EXA HGA0470EXA HGA0470EXD HGA2425ZXA HGA2425ZXD HGA2434ZXA HGA5453BAA HGA5453BXD HGA5453BXV HGA5457BAA HGA5460BAA HGA5460BXD HGA5467EXA HGA5467EXD HGA5467EXV HGA5471BAA HGA5471BXD HGA5471BXV HGA5479BAA HGA5479BXD HGA5479BXV HGA5480EXA HGA5480EXD HGA5480EXV HGA5480YXD

62 Remarks Overload MRA8940-113 MRA5806-113 MRA7943-113 MRA3711-114 MRA5753-114 MST00ADZ-113 MST00AJK-113 MST00AJK-113 14957962 MRA4734-113 T8900-78-ZP 8300MRAP11 MRA5751-113 14957914 MST00AHZ-113 MRA5809-113 570540 MRA5751-113 MRA3736-113 CRA4794-133 MRA5785-114 8300MSPU05 8300MRAS17 8300MSTT87 8300MSTT84 Relay ~ ~ K71-19 K71-16 ~ ~ ~ ~ ~ ~ ~ K71-19 ~ ~ ~ ~ K71-19 K71-16 ~ ~ K71-19 820ARR3K63 K71-19 820ARR3K63 820ARR3J44

Run CapRun Part Number K150-08 K150-04 K150-08 ~ ~ K150-14 ~ K150-04 ~ K150-10 ~ K150-14 K150-06 ~ ~ K150-04 545107 K150-06 K150-04 ~ K150-14 K150-04 K150-14 K150-06 K150-06 Number Start Cap Part K146-13 K146-13 K146-13 ~ ~ K146-13 ~ ~ ~ K146-13 ~ K146-12 ~ ~ ~ ~ 540244 K146-13 ~ ~ K146-42 64-77/330 K146-42 K146-12 K146-42 ~ ~ ~ ~ 0.7 3.0 0.7 3.0 4.3 0.6 2.3 3.5 2.2 0.7 2.3 2.3 3.6 0.6 2.3 3.5 0.7 3.0 0.6 2.3 2.6 Run ~ ~ ~ ~ 3.5 7.4 3.5 7.4 4.0 5.9 8.7 5.7 3.7 5.9 5.5 7.4 4.0 5.9 8.7 3.5 7.4 4.0 5.9 4.8 10.7 Start Winding Resistance 45.6 22.2 45.6 22.2 18.8 58.4 27.9 22.2 63.0 32.5 31.5 58.4 27.9 63.0 29.0 20.0 58.4 27.9 22.2 63.0 45.6 22.2 58.4 27.9 32.5 LRA ~ 8.0 4.0 7.6 3.7 3.3 9.6 4.6 3.8 5.6 4.2 9.0 4.4 5.6 4.6 5.0 4.6 2.1 6.5 3.1 4.1 11.8 12.7 10.4 13.9 RLA Volts/Hz/Ph 115/60/1 208-230/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 208-230/60/1 Model HGA5485BAA HGA5485BXD HGA5492EXA HGA5492EXD HGA5492EXV HGA5494BAA HGA5494BXD HGA5494BXV HGA5510BAA HGA5510BXD HGA5510BXV HGA5510EXA HGA5510EXD HGA5512BAA HGA5512BXD HGA5512BXV HGA5512EXA HGA5512EXD HGA5512EXV HGA5513BAA HGA9430YXA HGA9430YXD HGA9443YXA HGA9443YXD HGA9450ZXD

63 Remarks Overload K90-28 MRA5798-113 14957914 MRA5752-113 CRA4794-133 ~ MRA5785-114 ~ ~ ~ 571343 K90-18 MRA5731-114 MSP00AMZ-113 MSP18APZ-114 8300MRAN19 MRA5731-114 8300MSPT59 MSP00AMZ-113 K90-18 MRA5731-114 MRA5742-114 MRA5731-114 MRA5742-114 MRA5754-114 Relay ~ K71-17 ~ ~ ~ ~ K71-19 ~ ~ ~ 700357 K71-19 ~ ~ ~ ~ ~ ~ ~ K71-19 ~ ~ K71-19 K71-16 K71-19

Run CapRun Part Number K150-08 K150-10 ~ ~ ~ ~ K150-14 ~ ~ ~ ~ K150-08 K150-08 K150-03 ~ K150-08 K150-08 K150-03 K150-03 K150-08 K150-08 K150-03 K150-08 K150-03 K150-03 Number Start Cap Part K146-54 K146-13 ~ ~ ~ ~ K146-42 ~ ~ ~ 541170 K146-13 K146-13 ~ ~ ~ ~ ~ K146-13 K146-13 ~ ~ K146-13 K146-13 K146-13 ~ ~ ~ ~ ~ ~ 0.6 2.2 0.6 0.7 0.6 0.6 0.5 0.6 1.2 1.0 4.2 5.3 1.0 1.0 4.1 4.1 1.2 1.0 4.1 Run ~ ~ ~ ~ ~ ~ 6.6 6.8 3.6 3.6 6.6 6.6 3.6 3.6 6.6 2.9 5.9 4.0 2.0 4.0 2.0 2.1 4.1 3.6 3.6 Start Winding Resistance ~ 64.0 34.0 63.0 58.4 63.0 45.5 58.4 54.2 59.3 54.0 47.0 30.1 36.2 17.7 13.5 36.2 17.7 17.7 30.1 36.2 17.7 36.2 17.7 15.0 LRA 5.2 9.0 9.3 7.2 9.8 7.1 4.4 5.0 2.5 2.1 5.5 5.7 2.8 3.1 5.0 5.7 2.7 5.6 2.8 2.5 11.7 11.6 12.0 10.0 10.6 RLA Volts/Hz/Ph 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 115/60/1 208-230/60/1 208-230/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 265/60/1 Model HGA9468ZXA HGA9468ZXD HGAB514BAA HGAB514EXA HGAB515BAA HGB5510BAA HGB9443YAA HGBB514BAA HGBB515BAA HKGB515EXA RGA4450YXA RGA5450EXA RGA5453BAA RGA5453BXD RGA5453BXV RGA5457BAA RGA5460BAA RGA5460BXD RGA5460BXN RGA5460EXA RGA5467CXA RGA5467CXD RGA5467EXA RGA5467EXD RGA5467EXV

64 Remarks Overload MRA5805-113 MST22ALZ-114 MSP18APZ-114 MRA5731-114 MRA5742-114 MRA5754-114 MRA5805-113 8300MRAT71 MSP18APZ-114 MRA5723-114 K90-24 K90-24 MRA3711-5602 MRA8940-113 MRA5806-113 T14732-77-ZP MRA5743-114 MRA3711-114 MRA5753-114 ~ MRA3711-114 8300MRAP16 MST00ADZ-113 MST00AJK-113 MST00AJK-113 Relay ~ ~ ~ K71-19 K71-16 K71-19 ~ ~ ~ ~ ~ K71-19 K71-16 ~ ~ ~ K71-19 K71-16 ~ ~ K71-16 ~ ~ ~ ~

Run CapRun Part Number K150-08 K150-03 ~ K150-08 ~ ~ K150-08 K150-03 ~ ~ 545107 K150-08 15MFD400V-R K150-08 K150-04 ~ K150-08 K150-03 ~ K150-08 K150-03 10/440 K150-14 K150-06 K150-04 Number Start Cap Part ~ ~ ~ K146-13 ~ ~ ~ ~ ~ ~ ~ K146-13 ~ ~ ~ ~ K146-13 K146-13 ~ ~ K146-13 ~ ~ ~ ~ ~ ~ ~ 0.7 3.0 4.3 1.0 4.1 0.7 3.0 4.3 0.7 0.7 3.0 0.7 3.0 4.3 0.7 3.0 4.3 2.9 4.3 0.6 2.3 3.5 Run ~ ~ ~ 3.5 7.4 3.6 6.6 3.5 7.4 3.5 3.5 7.4 3.5 7.4 3.5 7.4 7.0 4.0 5.9 8.7 10.7 10.7 10.7 10.7 10.6 Start Winding Resistance ~ 45.6 22.2 19.0 36.2 17.7 15.0 45.5 17.5 45.6 45.6 45.6 22.2 45.6 22.2 18.8 45.6 22.2 18.8 45.6 22.2 18.8 58.4 27.9 22.0 LRA 7.0 3.4 2.9 6.1 3.0 2.7 7.6 3.6 3.4 7.0 7.0 7.0 3.5 8.0 4.0 3.3 7.2 3.4 3.1 7.6 3.8 3.3 9.6 4.6 3.8 RLA Volts/Hz/Ph 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 Model RGA5471BAA RGA5471BXD RGA5471BXV RGA5472EXA RGA5472EXD RGA5472EXV RGA5479BAA RGA5479BXD RGA5479BXV RGA5480CAA RGA5480CXA RGA5480EXA RGA5480EXD RGA5485BAA RGA5485BXD RGA5485BXV RGA5485EXA RGA5485EXD RGA5485EXV RGA5492EXA RGA5492EXD RGA5492EXV RGA5494BAA RGA5494BXD RGA5494BXV

65 Remarks Overload K90-27 MRA4734-113 T8900-78-ZP K90-21 K90-27 K90-27 14957914 MST00AHZ-113 MRA5809-113 K90-27 T24500-78-ZP K90-21 K90-27 MRA5751-113 MRA3736-113 830-10287 ~ ~ PURCH.BRAZIL PURCH.BRAZIL PURCH.BRAZIL 8300MRAN99 K90-27 ~ ~ Relay ~ ~ ~ K71-16 K71-19 ~ ~ ~ ~ ~ ~ K71-16 K71-19 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

Run CapRun Part Number K150-14 K150-10 ~ K150-06 K150-14 K150-14 K150-16 K150-11 K150-04 K150-14 K150-06 K150-06 K150-14 ~ K150-04 K150-16 ~ ~ K150-08 K150-08 K150-08 K150-08 50/370 ~ ~ Number Start Cap Part ~ ~ ~ K146-12 K146-13 ~ ~ ~ ~ ~ ~ K146-12 K146-13 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.3 3.5 0.5 1.2 1.1 0.8 0.8 0.6 0.6 0.5 2.2 3.3 0.6 0.5 2.3 3.6 0.6 2.3 2.3 0.6 Run ~ ~ ~ ~ ~ 5.7 5.9 4.0 3.9 5.5 7.4 4.0 5.9 5.9 4.0 5.9 8.7 3.5 2.7 2.6 2.9 3.0 2.1 2.0 2.1 Start Winding Resistance 63.0 32.5 31.5 27.9 58.4 63.0 63.0 29.0 20.0 58.4 27.9 27.9 58.4 27.9 22.2 63.0 63.0 63.0 30.7 31.5 41.1 45.6 58.4 54.2 59.3 LRA 5.6 4.2 4.4 9.2 5.6 4.6 4.7 5.0 5.0 4.3 4.1 4.8 6.0 7.7 9.0 9.8 11.8 12.5 12.7 10.1 10.2 13.9 11.6 12.0 10.0 RLA Volts/Hz/Ph 115/60/1 208-230/60/1 265/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 208-230/60/1 115-127/60/1 208-230/60/1 265/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 Model RGA5510BAA RGA5510BXD RGA5510BXV RGA5510ENA RGA5510EXA RGA5511BAA RGA5512BAA RGA5512BXD RGA5512BXV RGA5512CXA RGA5512CXD RGA5512ENA RGA5512EXA RGA5512EXD RGA5512EXV RGA5513BAA RGAB514BAA RGAB515BAA RGB5450EXA RGB5460EXA RGB5472EXA RGB5492EXA RGB5510EXA RGBB514BAA RGBB515BAA

66 Remarks Overload 570490 570519 K90-25 8300MRAL20 8300MRAL22 K90-17 K90-25 8300MRAL20 8300MRAL21 571312 570519 8300MRAL22 K90-17 8300MRAL19 K90-16 K90-25 K90-16 K90-12 8300MRAR96 8300MRAL22 K90-17 K90-12 ~ 8300MSTT52 K90-19 Relay 565115 ~ ~ ~ ~ ~ ~ ~ ~ 565115 ~ ~ K71-21 ~ 820ARR3H43 ~ ~ ~ ~ ~ ~ ~ ~ K71-21 ~

Run CapRun Part Number 545114 ~ K150-03 K150-03 K150-07 K150-03 K150-07 K150-03 K150-07 545104 ~ K150-07 K150-07 K150-07 K150-07 K150-07 K150-07 K150-07 K150-07 K150-07 K150-07 K150-07 K150-08 K150-07 K150-07 Number Start Cap Part 540160 ~ ~ ~ ~ ~ ~ ~ ~ 541160 ~ ~ ~ ~ K146-39 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.5 0.9 3.6 0.7 3.0 0.9 3.6 4.8 2.5 0.7 3.0 0.9 3.7 0.9 3.7 4.0 0.7 0.7 3.0 0.6 1.7 2.5 Run 13.5 13.5 ~ 6.7 5.0 5.9 4.3 4.0 5.0 5.9 3.9 6.7 4.3 4.0 4.0 4.2 4.0 4.2 3.6 4.3 4.3 4.0 2.9 3.8 3.6 13.5 13.5 Start Winding Resistance 25.0 16.0 39.2 23.0 48.3 27.0 39.2 23.0 16.0 26.0 16.0 48.3 27.0 44.0 20.0 44.0 20.0 18.6 48.3 48.3 27.0 22.0 57.0 38.0 26.3 LRA 3.8 1.9 5.5 2.4 6.0 3.2 6.6 3.4 3.2 3.8 2.0 7.3 3.6 7.4 3.7 7.4 3.8 3.3 8.6 8.6 4.3 4.2 8.4 4.5 4.6 RLA Volts/Hz/Ph 230/60/1 460/60/3 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 265/60/1 230/60/1 460/60/3 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 208-230/60/1 Model RKA5450YUZ RKA5450YXG RKA5454YXA RKA5454YXD RKA5470YXA RKA5470YXD RKA5480EXA RKA5480EXD RKA5480EXV RKA5480YUZ RKA5480YXG RKA5486YXA RKA5486YXD RKA5490CXA RKA5490CXD RKA5490EXA RKA5490EXD RKA5490EXV RKA5510CXA RKA5510EXA RKA5510EXD RKA5510EXV RKA5510YXA RKA5510YXD RKA5512CXD

67 Remarks Overload K90-27 K90-19 K90-14 ~ ~ K90-24 570519 K90-28 K90-21 8300MRAL29 K90-28 K90-21 8300MRAL29 8300MRAL30 8300MSTT80 K90-24 K90-21 570519 8300MSTM90 K90-26 8300MSTM90 K90-28 ~ K90-28 K90-28 Relay K71-19 ~ ~ 565105 ~ K71-21 ~ ~ ~ ~ K71-19 K71-21 ~ ~ ~ K71-21 ~ ~ ~ K71-16 ~ K71-19 K71-66 K71-19 K71-19

Run CapRun Part Number K150-07 K150-07 K150-11 545105 K150-08 K150-07 ~ K150-07 K150-07 ~ K150-07 K150-07 K150-11 ~ K150-11 K150-07 K150-11 ~ ~ K150-07 K150-11 K150-12 K150-16 ~ ~ Number Start Cap Part K146-13 K146-13 ~ 541160 ~ ~ ~ K146-41 K146-13 ~ K146-41 K146-13 ~ ~ ~ K146-13 ~ ~ ~ K146-13 ~ K146-13 K146-13 ~ ~ ~ ~ ~ 1.7 2.2 1.7 2.2 2.2 1.5 0.6 0.5 0.6 0.6 0.6 2.5 2.9 2.2 0.6 1.7 0.6 2.4 2.8 0.6 2.4 Run 13.5 ~ ~ ~ 4.4 3.6 4.6 4.9 4.0 3.8 4.0 5.0 5.6 4.0 5.0 3.8 4.9 3.8 4.9 4.9 4.3 4.4 3.2 4.1 4.1 13.5 Start Winding Resistance 38.0 32.0 38.0 32.0 31.0 32.0 45.0 32.0 54.0 71.0 54.0 54.0 54.0 26.3 28.0 30.0 57.0 38.0 16.0 67.0 29.0 27.0 67.0 29.0 27.0 LRA 9.7 4.8 4.2 4.8 9.8 4.9 2.3 5.2 4.8 5.4 4.8 6.4 5.3 6.4 5.4 4.7 6.3 7.6 6.3 9.0 11.0 11.4 11.0 13.0 10.8 RLA Volts/Hz/Ph 115/60/1 208-230/60/1 265/60/1 230/60/1 115/60/1 208-230/60/1 460/60/3 115/60/1 208-230/60/1 265/60/1 115/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 208-230/60/1 265/60/1 220/60/3 265/60/1 208-230/60/1 265/60/1 115/60/1 115/60/1 115/60/1 115/60/1 Model RKA5512EXA RKA5512EXD RKA5512EXV RKA5512YUZ RKA5512YXA RKA5512YXD RKA5512YXG RKA5513CXA RKA5513CXD RKA5513EVA RKA5513EXA RKA5513EXD RKA5513EXV RKA5515CXD RKA5515CXV RKA5515EXD RKA5515EXV RKA5518CKZ RKA5518EVA RKA5518EXD RKA5518EXV RKB5513EXA RKC5515EXA RKG5513EXA RKGB515EXA

68 Remarks Overload ~ ~ ~ ~ ~ EXRN104501 ~ INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

Run CapRun Part Number K150-19 ~ ~ ~ ~ ~ ~ ~ ~ K150-19 ~ ~ K150-22 ~ ~ ~ ~ K150-22 ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part ~ ~ ~ ~ ~ ~ ~ ~ ~ K146-44 ~ ~ K146-44 ~ ~ ~ ~ K146-44 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.3 3.6 0.3 0.6 2.0 3.1 0.5 2.0 3.1 0.3 0.5 1.9 2.9 0.5 1.8 0.5 1.5 0.3 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 1.8 1.5 1.5 Start Winding Resistance 52.0 58.0 58.0 71.0 65.0 72.0 71.0 60.0 48.4 66.0 54.0 66.0 54.0 72.0 58.0 75.9 89.0 LRA 155.0 108.0 125.0 160.0 125.0 142.0 151.0 160.0 ~ 7.4 8.1 9.4 7.0 5.7 7.7 6.1 7.8 6.4 9.5 7.6 11.3 12.7 13.7 24.4 22.5 14.3 15.0 25.2 15.7 19.0 10.5 21.0 12.4 RLA Volts/Hz/Ph 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 460/60/3 575/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 200-230/60/3 208-230/60/1 460/60/3 575/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 Model RNA5518YNA RNA5520YNA RNA5522YNA RNA5526CXN RNA5528BNA RNA5532BNA RNC5526CXN SFA5554EXG SFA5554EXH SFA5554EXN SFA5554EXT SFA5558EXG SFA5558EXH SFA5558EXT SFA5558EXN SFA5560EXG SFA5560EXH SFA5560EXN SFA5560EXT SFA5572EXG SFA5572EXH SFA5572EXT SFA5581EXG SFA5581EXT SFA5594EXG

69 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL 4TM213NFBYY-53 4TM283RFBYY-53 4TM283RFBYY-53 Relay ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ SR171104-ZR SR171102-ZR SR171102-ZR

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ K150-15 ~ ~ ~ K150-19 ~ ~ ~ ~ 85R-10070 ~ ~ Number Start Cap Part ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ K146-44 ~ ~ ~ K146-44 ~ ~ ~ ~ ~ ~ ~ ~ 0.5 0.7 2.3 3.6 0.3 0.6 2.0 3.1 0.5 7.4 2.0 0.4 1.2 2.0 0.3 1.0 1.4 0.3 0.9 1.4 0.2 2.8 5.0 Run 10.7 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.6 1.8 5.5 10.4 Start Winding Resistance 78.4 78.4 48.0 37.0 95.0 59.9 48.4 66.0 54.0 13.5 14.5 18.5 LRA 185.0 104.0 205.0 119.0 111.0 239.0 135.0 111.0 269.0 122.0 155.0 117.0 134.0 6.4 4.9 7.8 6.1 8.6 7.0 0.5 1.3 1.1 10.4 25.0 14.4 11.4 28.3 17.0 15.2 34.5 20.7 17.2 41.0 22.0 12.6 27.2 15.4 17.1 RLA Volts/Hz/Ph 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 208-230/60/1 200-230/60/3 460/60/3 575/60/3 200-230/60/3 115-127/60/1 115-127/60/1 115-127/60/1 Model SFA5594EXH SFA5594EXT SFA5611EXG SFA5611EXH SFA5611EXT SFA5612EXG SFA5612EXH SFA5612EXT SFA5615EXG SFA5615EXH SFA5615EXT SFAA530ZXG SFAA530ZXH SFAA530ZXN SFAA530ZXT SFAA536ZXG SFAA536ZXH SFAA536ZXN SFAA536ZXT SFAA540ZXG SFAA540ZXH SFAA540ZXT TA1325Y-DS3C TA1340Y-DS1A TA1340Y-DS1B

70 Remarks Overload 830-10148 4TM419TFBYY-53 4TM419TFBYY-53 830-10349 830-10040 830-10087 830-10040 830-10087 830-10087 830-10087 830-10383 830-10383 ~ 830-10281 T9019-24-ZP T28306-24-ZP T5706-23-ZP T88331-23-ZP 4TM232KFBYY-53 830-10281 ~ ~ 4TM408TFBYY-53 T7910-98-ZP 4TM197NFBYY-53 Relay SR171102-ZR SR171224-ZR SR171224-ZR 820-10293 820-10293 820-10294 820-10110 820-10082 820-10303 820-10082 9660C-3018-172 9660C-3018-172 ~ RP14701-ZR 820-10256 RP5501-ZR RP5815-ZR 820-10318 K71-23 RP4408-ZR ~ ~ 82008EAH05 14950763 SR171104-ZR

Run CapRun Part Number ~ 85R-10059 85R-10058 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ K150-01 14943072 ~ ~ ~ ~ ~ Number Start Cap Part ~ 85S-10098 85S-10098 85S-10097 85S-10097 85S-10097 85S-10088 85S-10097 85S-10096 85S-10097 85S-10099 85S-10099 ~ ~ ~ ~ ~ 301P270-324F165 ~ 85S-10021 ~ ~ ~ 14950762 ~ ~ ~ 4.0 3.3 2.8 4.0 4.0 4.5 3.4 2.3 2.4 2.3 2.2 2.1 3.8 3.1 2.3 2.0 1.7 3.8 3.6 2.3 2.6 9.2 8.7 Run ~ ~ 5.1 5.6 9.2 9.8 9.8 9.6 9.5 5.0 5.0 9.8 7.4 9.2 8.7 9.8 6.6 9.0 16.9 16.4 16.4 15.3 12.8 10.4 24.5 Start Winding Resistance 23.5 23.5 23.5 15.5 20.5 21.0 20.0 26.0 26.0 26.0 29.0 30.5 14.0 14.4 18.5 25.3 27.5 33.0 16.4 18.0 20.0 25.3 22.2 10.0 12.0 LRA 1.5 1.7 2.1 1.4 1.5 1.8 2.0 2.4 2.5 2.7 3.2 3.3 1.4 1.9 2.2 2.9 3.4 4.0 1.0 1.8 2.5 3.5 2.2 1.7 0.5 RLA Volts/Hz/Ph 115-127/60/1 115-127/60/1 115-127/60/1 115-127/60/1 115-127/60/1 115/60/1 115-127/60/1 115-127/60/1 115/60/1 115-127/60/1 115-127/60/1 115-127/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115-127/60/1 115/60/1 115/60/1 208-220/60/1 115-127/60/1 Model TA1360Y-DS1B TC1410U-DS7C TC1413U-DS7C TCW330U-DS8B TCW350U-DS6B TCW360U-LS6A TCW380U-DS6B TCW390U-DS6B TCW390U-LS6B TCW410U-DS6B TCX413U-DS1B TCX415U-DS1B THA0347YXA THA0370YXA THA0384YXA THA0410YXA THA0412YXA THA0414YXA THA1340YXA THA1358YXA THA2395UDS THA9416UAA THB1355YXA THB4419YHZ THG1328YCS

71 Remarks Overload 4TM308MFBYY-53 ~ ~ 4TM314PFBYY-53 ~ T86635-23-ZP 4TM419LFBYY-53 ~ 8300MRPS30 8300MRAS43 8300MRPS44 8300MRAS43 ~ 8300MRPR89 ~ K90-05 K90-05 K90-05 K90-05 83004TMP67 K90-73 T91531-23-ZP MRA58179-5586 ~ 8300MRAT26 Relay SR171102-ZR ~ K71-23 SR171102-ZR ~ SR171102-ZR SR171104-ZR ~ K71-08 82767 K71-08 82767 ~ K71-04 ~ K71-23 K71-23 K71-23 K71-23 82008EAJ54 K71-23 RP16218-ZR 820-10267 ~ K71-05

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ K150-02 K150-02 K150-02 K150-02 K150-03 K150-02 ~ ~ ~ ~ Number Start Cap Part ~ ~ ~ ~ ~ ~ ~ ~ K146-22 K146-29 K146-22 K146-29 ~ ~ ~ ~ ~ ~ ~ ~ ~ K146-23 85S-10086 ~ K146-24 ~ ~ ~ ~ ~ 4.0 3.8 4.1 2.7 4.3 1.6 4.8 1.6 4.8 1.4 4.2 1.0 2.7 2.7 2.7 2.7 6.1 1.8 1.3 5.7 Run ~ ~ ~ ~ ~ 9.2 8.5 6.1 9.2 9.1 9.1 4.5 4.5 4.5 4.5 4.0 7.9 11.0 11.3 30.1 30.1 16.8 10.6 19.2 16.6 Start Winding Resistance 16.0 17.5 16.4 18.0 10.5 22.0 21.0 17.0 30.0 19.2 30.0 19.2 37.5 25.5 42.5 21.3 21.3 21.3 21.3 15.8 20.5 31.0 42.0 26.5 15.5 LRA 1.4 1.4 1.0 1.5 0.8 2.1 1.6 1.1 3.8 2.2 4.0 2.3 5.5 3.4 6.1 1.2 1.4 1.6 1.8 1.1 2.2 4.3 4.6 3.9 2.0 RLA Volts/Hz/Ph 115/60/1 115/60/1 115/60/1 115-127/60/1 220/60/1 115/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115-127/60/1 115/60/1 208-230/60/1 Model THG1335YLS THG1340YLS THG1340YXA THG1352YDS THG1352YGS THG1358YLS THG1374YXA THK1358YAS TPA0413YXA TPA0413YXD TPA0415YXA TPA0415YXD TPA0421YXA TPA0421YXD TPA0423YXA TPA1370YXA TPA1380YXA TPA1390YXA TPA1410YXA TPA1410YXD TPA1413YXA TPA2411ZAA TPA2414UDS TPA9415YXA TPA9415YXD

72 Remarks Overload ~ ~ K90-14 K90-14 8300MRPR89 ~ ~ K90-17 8300MRAT74 T13494-23-ZP T89506-23-CXF K90-05 83004TMR17 8300MRAT23 ~ T28794-23-ZP K90-17 K90-05 K90-05 K90-05 K90-05 K90-05 K90-05 ~ ~ Relay ~ K71-10 K71-06 K71-06 K71-27 ~ ~ K71-06 820RR12L03 8200EMBJ77 14949970 K71-23 K71-23 8209660L79 ~ 14949065 K71-06 K71-23 K71-23 K71-23 K71-23 K71-23 K71-23 ~ ~

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ K150-02 K150-02 ~ K150-02 K150-02 15MFD220V-H ~ ~ Number Start Cap Part ~ K146-17 K146-25 K146-25 K146-31 ~ ~ K146-51 K146-36 302P216-259F220 K146-51 ~ ~ K146-14 ~ K146-51 K146-51 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 1.2 1.0 1.0 4.3 0.9 3.3 2.3 1.9 1.6 1.0 0.8 2.6 2.6 2.8 2.8 2.8 3.3 9.0 3.3 Run ~ ~ ~ ~ ~ ~ 7.9 5.9 5.9 4.8 8.7 4.7 6.0 5.1 4.3 4.3 4.5 4.5 4.5 4.3 4.3 13.9 15.4 10.2 14.5 Start Winding Resistance 32.0 34.0 40.0 40.0 21.2 36.0 36.0 44.5 24.0 36.0 27.9 23.5 25.5 26.0 34.0 44.4 44.5 21.3 21.3 19.5 19.5 19.5 19.0 12.5 19.0 LRA 5.0 5.0 6.2 6.4 3.3 4.8 6.1 6.9 3.6 6.1 3.4 2.1 2.7 3.7 4.7 6.2 6.6 1.4 1.6 1.2 1.4 1.5 1.1 0.7 1.3 RLA Volts/Hz/Ph 115/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 208-230/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 220/60/1 115/60/1 Model TPA9415ZAA TPA9417YXA TPA9419YXA TPA9421YXA TPA9421YXD TPA9423UAA TPA9423XAA TPA9423YXA TPA9423YXD TPA9423ZAA TPB0413YAA TPB1370YXA TPB1390YXA TPB9415YAA TPB9417YAA TPB9421YAA TPB9423YAA TPD1380YXA TPD1390YXA TPE1370YXA TPE1380YXA TPE1390YXA TPG1370YXA TPG1380YMS TPG1380YXA

73 Remarks Overload ~ ~ 4TM427NFBYY-53 ~ 10590379 10590379 4TM435PFBZZ-53 4TM757TFBZZ-53 ~ INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ SR171224-ZR ~ SR171104-ZR ~ SR171403-ZR RP5618-ZR ~ K71-43 ~ ~ K71-19 ~ ~ ~ K71-19 ~ ~ K71-43 ~ ~ ~ K71-43 ~

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ K150-14 ~ ~ K150-14 ~ ~ ~ K150-14 ~ ~ ~ ~ ~ ~ K150-18 ~ Number Start Cap Part ~ ~ 302P216-259F165 ~ ~ ~ ~ 302P270-324F165 ~ K146-13 ~ ~ K146-13 ~ ~ ~ K146-13 ~ ~ K146-13 ~ ~ ~ K146-13 ~ ~ ~ ~ 9.0 3.3 2.5 4.3 2.3 7.5 1.1 8.8 2.3 0.9 8.8 8.8 2.3 0.9 7.4 1.9 0.6 7.4 7.4 1.9 0.6 5.1 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 4.3 3.8 6.1 5.6 7.5 2.7 2.8 2.8 1.9 1.9 14.5 Start Winding Resistance 4.0 12.5 19.0 22.5 30.0 17.0 19.0 23.0 28.5 50.7 21.0 40.5 65.9 19.9 21.0 40.5 65.9 25.0 48.5 83.0 21.5 25.0 48.5 83.0 35.1 LRA 0.8 1.5 1.7 3.1 1.1 0.9 2.1 2.6 1.0 7.2 2.5 5.2 8.0 2.8 2.8 5.6 8.8 3.3 6.5 3.7 3.7 7.1 4.0 10.3 12.0 RLA Volts/Hz/Ph 208-230/60/1 115/60/1 115/60/1 115-127/60/1 115/60/1 115/60/1 115-127/60/1 115-127/60/1 250/53-150/1 208-230/60/1 460/60/3 200-230/60/3 208-230/60/1 440/60/3 460/60/3 200-230/60/3 208-230/60/1 460/60/3 200-230/60/3 208-230/60/1 440/60/3 460/60/3 200-230/60/3 208-230/60/1 440/60/3 Model TPG1390YMR TPG1390YXA TPG1410YXA TPH1410YDS TSA1374YAS TSB1355YAS TSB1380YDS TSB1390YDS VE1348Y-MA5C VSA9490ZNA VSA9490ZXG VSA9490ZXT VSA9510ZNA VSA9510ZTZ VSA9510ZXG VSA9510ZXT VSA9512ZNA VSA9512ZXG VSA9512ZXT VSA9514ZNA VSA9514ZTZ VSA9514ZXG VSA9514ZXT VSA9517ZNA VSA9517ZTZ

74 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ K71-21 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

Run CapRun Part Number ~ ~ K150-21 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part ~ ~ K146-13 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 5.1 0.7 0.5 4.1 4.1 1.1 0.8 4.2 1.1 2.7 2.7 0.7 1.8 1.8 0.4 1.5 0.4 0.7 1.1 4.2 1.1 1.1 2.7 0.7 1.8 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 2.0 Start Winding Resistance 33.7 77.5 40.4 40.4 80.0 40.8 80.0 47.5 47.5 96.0 72.9 72.9 80.4 77.5 80.0 40.8 80.0 80.0 48.3 96.0 73.0 LRA 101.6 104.0 153.0 156.0 7.0 8.2 5.1 5.4 9.8 5.2 6.0 8.0 7.6 9.0 9.4 7.0 8.3 4.2 8.6 9.3 5.7 7.4 14.6 12.6 10.2 12.2 15.9 19.1 11.4 RLA Volts/Hz/Ph 460/60/3 200-230/60/3 208-230/60/1 440/60/3 460/60/3 200-230/60/3 200-230/60/3 460/60/3 200-230/60/3 440/60/3 460/60/3 200-230/60/3 440/60/3 460/60/3 200-230/60/3 460/60/3 200-230/60/3 200-230/60/3 200-230/60/3 460/60/3 200-230/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 Model VSA9517ZXG VSA9517ZXT VSA9521ZNA VSA9521ZTZ VSA9521ZXG VSA9521ZXT VSA9524ZTB VSA9524ZXG VSA9524ZXT VSA9528ZTZ VSA9528ZXG VSA9528ZXT VSA9536ZTZ VSA9536ZXG VSA9536ZXT VSA9544ZXG VSA9544ZXT VSAG475ZXT VSAG494ZXT VSAG511ZXG VSAG511ZXT VSAG513ZXT VSAG514ZXG VSAG514ZXT VSAG518ZXG

75 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ ~ K71-43 ~ K71-43 ~ K71-43 K71-58 K71-58 K71-59 K71-58 K71-59 K71-58 K71-59 K71-59 K71-59 K71-59 K71-59 K71-59 K71-59 K71-59 K71-59 K71-59 K71-59

Run CapRun Part Number ~ ~ ~ K150-18 ~ K150-18 ~ K150-21 85PR370F21 85PR370F21 85PR370F26 85PR370F21 85PR370F31 85PR370F21 85PR370F31 85PR370F29 85PR370F31 85PR370F29 85PR370F29 85PR370F29 85PR370F29 85PR370F29 85PR370F32 85PR370F32 85R-10046 Number Start Cap Part ~ ~ ~ K146-13 ~ K146-41 ~ K146-43 K146-44 K146-44 K146-12 K146-44 K146-12 K146-44 K146-12 K146-12 K146-12 K146-12 K146-12 K146-12 K146-12 K146-12 K146-49 K146-49 K146-64 0.7 0.5 0.6 0.6 0.6 0.6 0.5 0.6 0.5 0.4 0.4 0.3 0.4 1.5 0.4 0.8 6.0 0.8 6.0 0.6 0.8 0.7 0.7 0.7 0.5 Run ~ ~ ~ ~ ~ 1.8 1.9 1.5 1.7 1.6 1.7 1.6 1.4 1.6 1.4 1.5 1.5 1.5 1.5 1.5 1.5 1.3 1.1 1.1 0.8 Start Winding Resistance 96.7 80.4 69.8 29.5 71.9 29.5 83.6 69.0 96.7 87.5 96.7 LRA 105.0 115.0 105.0 115.0 115.0 115.0 115.0 120.0 135.0 135.0 145.0 153.0 156.1 105.0 8.4 9.0 3.1 3.4 14.7 16.8 10.8 11.9 12.2 17.0 16.0 16.7 21.5 16.7 21.5 21.0 19.5 21.0 21.0 21.0 23.0 24.4 27.0 27.5 29.0 RLA Volts/Hz/Ph 200-230/60/3 460/60/3 200-230/60/3 208-230/60/1 460/60/3 208-230/60/1 460/60/3 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 Model VSAG518ZXT VSAG523ZXG VSAG523ZXT VSBG475ZNA VSBG475ZXG VSBG494ZNA VSBG494ZXG VSBG511ZNA VSC5525ENA VSC5529BNA VSC5532BNA VSC5532ENA VSC5534BNA VSC5534ENA VSC5536BNA VSC5538BNA VSC5538ENA VSC5540BNA VSC5540ENA VSC5542ENA VSC5545ENA VSC5547ENA VSC5548BNA VSC5550BNA VSC5554BNA

76 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay K71-59 K71-59 K71-59 K71-58 ~ ~ ~ ~ ~ ~ ~ K71-58 ~ ~ ~ ~ ~ ~ ~ K71-58 ~ ~ ~ ~ ~

Run CapRun Part Number 85PR370F32 85R-10046 85R-10046 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part K146-49 K146-64 K146-64 K146-44 ~ ~ ~ ~ ~ ~ ~ K146-44 ~ ~ ~ ~ ~ ~ ~ K146-44 ~ ~ ~ ~ ~ 0.3 0.3 0.3 0.8 6.7 1.7 0.8 6.7 1.7 0.7 4.7 7.3 1.2 0.7 4.7 7.3 1.2 0.7 4.7 7.3 1.2 0.7 4.7 Run 10.6 10.6 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 0.8 0.8 0.8 1.7 1.7 1.6 1.6 1.6 1.6 Start Winding Resistance 69.0 30.0 26.0 60.0 69.0 30.0 26.0 60.0 97.0 45.0 38.0 95.0 97.0 45.0 38.0 95.0 97.0 45.0 38.0 95.0 97.0 45.0 LRA 150.0 145.0 145.0 4.5 3.5 9.3 4.5 3.5 9.3 6.1 5.0 6.1 5.0 6.1 4.5 6.1 25.0 30.1 28.8 12.2 12.2 16.0 11.2 16.0 11.2 16.7 11.2 16.7 RLA Volts/Hz/Ph 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 460/60/3 575/60/3 200-230/60/3 208-230/60/1 460/60/3 575/60/3 200-230/60/3 208-230/60/1 460/60/3 575/60/3 200-230/60/3 208-230/60/1 460/60/3 575/60/3 200-230/60/3 208-230/60/1 460/60/3 575/60/3 200-230/60/3 208-230/60/1 460/60/3 Model VSC5554ENA VSC5556BNA VSC5560ENA VSC9515XNA VSC9515XXG VSC9515XXH VSC9515XXT VSC9515ZNA VSC9515ZXG VSC9515ZXH VSC9515ZXT VSC9519XNA VSC9519XXG VSC9519XXH VSC9519XXT VSC9519ZNA VSC9519ZXG VSC9519ZXH VSC9519ZXT VSC9521XNA VSC9521XXG VSC9521XXH VSC9521XXT VSC9521ZNA VSC9521ZXG

77 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ K71-59 ~ ~ ~ ~ ~ ~ ~ K71-59 ~ ~ ~ ~ ~ ~ ~ K71-67 ~ ~ ~ ~ ~ ~

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part ~ ~ K146-13 ~ ~ ~ ~ ~ ~ ~ K146-49 ~ ~ ~ ~ ~ ~ ~ K146-13 ~ ~ ~ ~ ~ ~ 7.3 1.2 0.5 4.7 7.3 1.2 0.5 4.7 7.3 1.2 0.3 2.6 4.4 0.7 0.3 2.6 4.4 0.7 0.3 2.3 4.1 0.6 0.3 2.3 4.1 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 1.5 1.5 0.9 0.9 1.8 1.8 Start Winding Resistance 60.0 42.0 70.0 53.0 70.0 53.0 38.0 95.0 45.0 38.0 95.0 45.0 38.0 95.0 60.0 42.0 LRA 120.0 150.0 120.0 160.0 123.0 160.0 115.0 115.0 150.0 4.5 6.4 5.1 6.4 5.1 8.3 5.1 8.3 5.1 9.6 4.7 9.6 4.7 11.2 21.0 14.1 21.0 14.1 24.4 16.7 24.4 16.7 28.9 16.7 28.9 RLA Volts/Hz/Ph 575/60/3 200-230/60/3 208-230/60/1 460/60/3 575/60/3 200-230/60/3 208-230/60/1 460/60/3 575/60/3 200-230/60/3 208-230/60/1 460/60/3 575/60/3 200-230/60/3 208-230/60/1 460/60/3 575/60/3 200-230/60/3 208-230/60/1 460/60/3 575/60/3 200-230/60/3 208-230/60/1 460/60/3 575/60/3 Model VSC9521ZXH VSC9521ZXT VSC9526XNA VSC9526XXG VSC9526XXH VSC9526XXT VSC9526ZNA VSC9526ZXG VSC9526ZXH VSC9526ZXT VSC9530XNA VSC9530XXG VSC9530XXH VSC9530XXT VSC9530ZNA VSC9530ZXG VSC9530ZXH VSC9530ZXT VSC9538XNA VSC9538XXG VSC9538XXH VSC9538XXT VSC9538ZNA VSC9538ZXG VSC9538ZXH

78 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 0.6 1.8 2.9 0.5 1.8 2.9 0.5 1.7 2.5 0.4 1.7 2.5 0.4 1.4 2.3 0.4 1.4 2.3 0.4 1.3 2.0 0.3 1.3 2.0 0.3 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Start Winding Resistance 82.0 64.0 82.0 64.0 87.0 67.0 87.0 67.0 95.0 75.0 95.0 75.0 95.0 95.0 LRA 123.0 170.0 170.0 190.0 190.0 190.0 190.0 110.0 235.0 110.0 235.0 9.6 7.7 9.6 7.7 8.3 8.3 9.4 9.4 16.7 19.2 19.2 10.3 23.7 10.3 23.7 12.8 25.6 12.8 25.6 16.0 11.5 29.5 16.0 11.5 29.5 RLA Volts/Hz/Ph 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 Model VSC9538ZXT VSC9545XXG VSC9545XXH VSC9545XXT VSC9545ZXG VSC9545ZXH VSC9545ZXT VSC9548XXG VSC9548XXH VSC9548XXT VSC9548ZXG VSC9548ZXH VSC9548ZXT VSC9558XXG VSC9558XXH VSC9558XXT VSC9558ZXG VSC9558ZXH VSC9558ZXT VSC9566XXG VSC9566XXH VSC9566XXT VSC9566ZXG VSC9566ZXH VSC9566ZXT

79 Remarks Overload INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL INTERNAL Relay ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

Run CapRun Part Number ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Number Start Cap Part ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 1.1 1.7 0.3 1.1 1.7 0.3 0.6 2.3 0.5 1.7 0.4 1.7 0.4 1.5 0.4 Run ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Start Winding Resistance 90.0 95.0 62.0 88.5 184.0 190.0 150.0 240.0 LRA 140.0 100.0 235.0 140.0 100.0 235.0 123.0 180.0 8.0 9.6 19.2 14.2 32.0 19.2 14.2 32.0 17.9 18.5 10.0 20.0 13.5 25.6 16.7 32.0 RLA Volts/Hz/Ph 460/60/3 575/60/3 200-230/60/3 460/60/3 575/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 200-230/60/3 460/60/3 200-230/60/3 Model VSC9576XXG VSC9576XXH VSC9576XXT VSC9576ZXG VSC9576ZXH VSC9576ZXT VSCF513ZXG VSCF513ZXT VSCF515ZXG VSCF515ZXT VSCF518ZXG VSCF518ZXT VSCF524ZXG VSCF524ZXT VSCF534ZXG VSCF534ZXT

80 Introduction to Electrical Drawings

1. The drawings which follow cover both current production and obsolete compressor models.

2. For ease in determination of the proper drawing, indexes are provided.

3. Each drawing has a descriptive title, a representative compressor photograph.

4. The following general points should be considered:

A. All notations are important and must be heeded. B. All ESP relays must be mounted as shown in the drawings or, in the case of remote installations, exactly as was the original. C. The two terminal overloads shown in the drawings are typical examples. ESP overloads may be provided with terminals at #1 and #3 or #1 and #2 or may have factory applied leads or straps. Regardless, as long as they are wired as shown in the drawings, the circuit will be correct. D. Fan motor leads, if not originally connected elsewhere in the equipment, are always connected to line terminals.

81 Page Compressor Series Description

83 AE/AE2 RSIR and CSIR with current relay 84 AE/AE2 PSC or CSR with potential relay 85 AG PSC or CSR with potential relay 86 AH CSIR with current relay 87 AH PSC or CSR with potential relay 88 AJ CSIR with current relay 89 AJ PSC or CSR with potential relay 91 AK CSIR with current relay 92 AK/AK2 PSC or CSR with potential relay 93 AV PSC or CSR with potential relay 94 AW PSC or CSR with potential relay 95 AZ/TH RSIR or CSIR with current relay 96 RG, RK PSC or CSR with potential relay 97 SF PSC or CSR with potential relay 98 TP PTCS-CR and CSIR with current relay 99 VS PSC or CSR with potential relay 100 AB PSC or CSR with potential relay 101 CL PSC or CSR with potential relay (internal overload models) 102 CL PSC or CSR with potential relay (internal models) 103 CL 3 Phase (internal thermostat models)

82 AE/AE2 Series Compressor

Representative photo only Many variations possible

Compressor 2 Terminal Fence C S R Overload 1 3 1 Relay - Current (push on)

Jump Wire 115V Only - Neutral

(RSIR)

Compressor 2 Terminal Fence C S R Overload 1 3 1 Relay - Current (push on)

115V Only - Neutral Start Capacitor

(CSIR)

83 AE/AE2 Series Compressor

Representative photo only Many variations possible Compressor

C Terminal Fence S R

3 1 Overload

115V Only - Neutral Run Capacitor (PSC)

Compressor Terminal Fence C S R

3 1 Overload

6 5 2 4 1 115V Only - Neutral

(CSR) Relay - Potential Start Run Capacitor Capacitor

NOTE: Wire to relay as shown regardless of terminal location.

84 AG Series Compressor

Representative photo only Many variations possible Crankcase Heater must be connected to Compressor C S line side of . Terminal Fence R

L

T1 L T2 Crankcase Heater Run Capacitor (PSC)

C S Crankcase Heater Compressor must be connected to Terminal Fence R line side of contactor.

L L Crankcase Heater

5 6 2

4 1

Relay - Potential Start Run Capacitor Capacitor (CSR) NOTE: Wire to relay as shown regardless of terminal location.

85 AH Series Compressor

Representative photo only Many variations possible

Compressor Terminal Fence C R S

1 2 M

Start Capacitor S L Relay - Current (remote mount with bracket)

(CSIR)

NOTE: Wire to relay as shown regardless of terminal location.

86 AH Series Compressor

Representative photo only Many variations possible

Compressor Terminal Fence S C R

(PSC) Run Capacitor

Compressor C Terminal Fence S R

5 6 2 4 1

Run Relay - Potential Capacitor Start (CSR) Capacitor

NOTE: Wire to relay as shown regardless of terminal location.

87 AJ Series Compressor

Representative photo only Many variations possible

Compressor Terminal Fence C R 1 S 3 Overload

115V Only - Neutral 1 2 M Relay - Current (remote mount) Start Capacitor L S

(CSIR)

NOTE: Wire to relay as shown regardless of terminal location.

88 AJ Series Compressor

Representative photo only Many variations possible

Compressor C R 1 Terminal Fence S 3

Overload

115V Only - Neutral 5 6 2 4 1

Relay – Potential Start Capacitor (CSIR)

NOTE: Wire to relay as shown regardless of terminal location.

89 AJ Series Compressor

Representative photo only Many variations possible Compressor Terminal Fence C R 1 3 S Overload

Run Capacitor

(PSC) 115V Only - Neutral

Compressor Terminal Fence C R 1 3 S Overload

5 6 2 4 1 115V Only - Neutral Run Relay - Potential Capacitor Start (CSR) Capacitor

NOTE: Wire to relay as shown regardless of terminal location.

90 AK Series Compressor

Representative photo only Many variations possible

Compressor

Terminal Fence C R 1 3 S Overload

115V Only - Neutral 1 2 M Start Capacitor Relay – Current L (remote mount) S

(CSIR)

NOTE: Wire to relay as shown regardless of terminal location.

91 AK/AK2 Series Compressor

Representative photo only Many variations possible

3 Overload 1

S Compressor C R Terminal Fence

115V Only - Neutral Run Capacitor (PSC)

3 1 Overload Compressor S C R Terminal Fence

115V Only - Neutral 5 6 2 4 1

Run Relay – Potential Start Capacitor (CSR) Capacitor

NOTE: Wire to relay as shown regardless of terminal location.

92 AV Series Models

Representative photo only Many variations possible Crankcase Heater must be connected to line side of contactor.

C S R Compressor Terminal Fence

L 1

L 2 T1

Crankcase T2 Heater Run Capacitor (PSC)

C Crankcase Heater must be connected S to line side of contactor. R Compressor Terminal Fence

L 1

L 2

T1 5 6 2

4 1 Crankcase T2 Heater

Relay – Potential Start Capacitor Run Capacitor (CSR)

93 AW Series Compressor

Representative photo only Many variations possible Compressor Terminal Fence

C

R S

Run Capacitor (PSC)

Compressor Terminal Fence

C R S

6 5 2 4 1

Run Relay – Potential Capacitor Start (CSR) Capacitor

NOTE: Wire to relay as shown regardless of terminal location.

94 AZ/TH Series Compressor

Representative photo only Many variations possible

Compressor 2 Terminal Fence C 1 S R Overload 1 3 Jumper Wire

Relay – Current 115V Only - Neutral (Push On) (RSIR)

Compressor 2 Terminal Fence C 1 S R Overload 1 3

Relay – Current 115V Only - Neutral (Push On)

Start Capacitor (CSIR)

95 RG and RK Series Rotary Compressor

Representative photos only Compressor Many variations possible C Terminal Fence S R

3 1 Overload

115V Only - Neutral Run Capacitor (PSC)

Compressor C S R Terminal Fence

3 1 Overload

5 6 2 4 1 115V Only - Neutral Run Capacitor Relay –Potential Start Capacitor (CSR)

NOTE: Wire to relay as shown regardless of terminal location.

96 SF Series Compressors

Compressor Terminal Fence

C

R S

(PSC) Run Capacitor

Compressor Terminal Fence

C R S

5 6 2 4 1

Run Relay – Potential Capacitor Start Capacitor (CSR)

NOTE: Wire to relay as shown regardless of terminal location.

97 TP Series Compressor (LBP Models)

4 T M Overload

C

115 Volt Only – Neutral S

Relay – PTC (push-on) R Run Capacitor (PTCS-CR)

TP Series Compressor (CBP Models)

Compressor 2 Terminal Fence C 1 S R Overload 1 3

Relay – Current 115V Only - Neutral (Push On)

Start Capacitor (CSIR)

98 VS Series Compressor

Representative photo only Many variations possible

TRMNAL PN ORNTATON Ring Connect Screw Terminal Quick Connect Spade Terminal

CT1 CT1 1 RT3 3 2 ST2 RT3

ST2

WRN ARAMS

PSC C S

Line Run Capacitor

R

CSR Potential C S Relay

Line Run Start Capacitor Capacitor

R

99 AB Series Compressor

Representative photo only Many variations possible Compressor Terminal Fence

C

R S

Run Capacitor (PSC)

Compressor Terminal Fence

C R S

6 5 2 4 1

Run Relay – Potential Capacitor Start Capacitor (CSR)

NOTE: Wire to relay as shown regardless of terminal location.

100 CL Series Compressor

Representative photo only Many variations possible

Compressor Equipped Terminal Fence C with S Internal R Overload

Run Capacitor (PSC)

Compressor Terminal Fence Equipped with Internal Overload S Relay – C Potential R 5 Run 2 Capacitor 4 6 1

Capacitor Box Ass’y (if used) (CSR) Start Capacitor

NOTE: Wire to relay as shown regardless of terminal location.

101 CL Series Compressor

Representative photo only Many variations possible Supplementary Overload

3 To Control Circuit 2 Internal Thermostat 1 4 Compressor Terminal Fence S C R

Run Capacitor

(PSC)

Supplementary Overload

2 3 To Control Circuit Internal Thermostat 1 4 Compressor

C Terminal Fence S R

6 5 2 4 1

(CSR) Run Relay – Potential Start Capacitor Capacitor

NOTE: Wire to relay as shown regardless of terminal location.

102 CL Series Compressor

Representative photo only Many variations possible

Internal Thermostat To Control Circuit

3 300V Max - 125V Max Supplementary 1 1 4 2 3 Overload 4 2

L1 L2 L3 Supplementary Overload

Compressor Terminal Fence

(3 Phase)

103 Trouble Shooting and Service Chart Complaint Possible Cause Repair

Compressor will 1. Line disconnect open. 1. Close start or disconnect . A not start - no 2. Fuse removed or blown. 2. Replace fuse. hum 3. Overload protector tripped. 3. Refer to electrical section. 4. Control stuck in open position. 4. Repair or replace control. 5. Control off due to cold location. 5. Relocate control. 6. Wiring improper or loose. 6. Check wiring against diagram.

Compressor will 1. Improperly wired. 1. Check wiring against diagram. B not start - hums 2. Low voltage to unit. 2. Determine reason and correct. but trips on 3. Starting capacitor defective. 3. Determine reason and replace. overload 4. Relay failing to close. 4. Determine reason and correct, protector replace if necessary. 5. Compressor motor has a 5. Replace compressor. winding open or shorted. 6. Internal mechanical trouble 6. Replace compressor. in compressor. 7. Liquid refrigerant in compressor. 7. Replace compressor.

Compressor 1. Improperly wired. 1. Check wiring against diagram. C starts, but does 2. Low voltage to unit. 2. Determine reason and correct. not switch off 3. Relay failing to open. 3. Determine reason and correct, of start winding replace if necessary. 4. Run capacitor defective. 4. Determine reason and replace. 5. Excessively high discharge 5. Check discharge shut-off valve, pressure. possible overcharge, or in- sufficient cooling on condenser. 6. Compressor motor has a 6. Replace compressor. winding open or shorted. 7. Internal mechanical trouble in 7. Replace compressor. compressor (tight).

Compressor 1. Additional current passing 1. Check wiring diagram. Check D starts and runs, through overload protector. for added fan motors, pumps, but short cycles etc., connected to wrong side on overload of protector. protector 2. Low voltage to unit (or un- 2. Determine reason and correct. balanced if three phase). 3. Overload protector defective. 3. Check current, replace protector. 4. Run capacitor defective. 4. Determine reason and replace. 5. Excessive discharge pressure. 5. Check ventilation, restrictions in cooling medium, restrictions in refrigeration system. 6. Suction pressure too high. 6. Check for possibility of mis- application. Use stronger unit. 7. Compressor too hot - return 7. Check refrigerant charge (fix gas hot. leak), add if necessary. 8. Compressor motor has a 8. Replace compressor. winding shorted.

104 Trouble Shooting and Service Chart Complaint Possible Cause Repair

Unit runs OK, 1. Overload protector. 1. See D on previous page. E but short 2. Thermostat. 2. Differential set too close-widen. cycles on 3. High pressure cut-out due to: 3. a - Insufficient air/water supply a -Check air/water supply to condenser - correct. b - Overcharge b - Reduce refrigerant charge c - Air in system c -Purge 4. Low pressure cut-out due to: 4. a - Liquid line leaking a - Replace b - Compressor valve leak b - Replace c - Undercharge c - Fix leak, add refrigerant d - Restriction in expansion device d - Replace device

Unit operates 1. Shortage of refrigerant. 1. Fix leak, add charge. F long or 2. Control contacts stuck or 2. Clean contacts or replace continuously frozen closed. control. 3. Refrigerated or air conditioned 3. Determine fault and correct. space has excessive load or poor insulation. 4. System inadequate to handle 4. Replace with larger system. load. 5. Evaporator coil iced. 5. Defrost. 6. Restriction(s) in 6. Determine location and refrigeration system. remove. 7. Dirty condenser. 7. Clean condenser. 8. Filter dirty. 8. Clean or replace.

Start capacitor 1. Relay contacts not operating 1. Clean contacts or replace relay G open, shorted, properly. if necessary. or blown 2. Prolonged operation on start 2. cycle due to: a - Low voltage to unit a - Determine reason and correct b - Improper relay b - Replace c - Starting load too high c - Correct by using pump down arrangement if necessary 3. Excessive short cycling. 3. Determine reason for short-cycle (E above) and correct. 4. Improper capacitor. 4. Determine reason and correct.

Run capacitor 1. Improper capacitor. 1. Determine correct size and replace. H open, shorted, 2. Excessively high line voltage 2. Determine reason and correct. or blown (110% of rated-max).

105 Trouble Shooting and Service Chart Complaint Possible Cause Repair

Relay defective 1. Incorrect relay. 1. Check and replace. I or burned out 2. Incorrect mounting angle. 2. Remount relay in correct position. 3. Line voltage too high or too low. 3. Determine reason and correct. 4. Excessive short cycling. 4. Determine reason (See E on previous page) and correct. 5. Relay being influenced by 5. Remount rigidly. loose mounting. 6. Incorrect run capacitor. 6. Replace with proper capacitor.

Conditioned 1. Control setting too high. 1. Reset control. J space temperature 2. Expansion valve too small. 2. Use larger valve. too high 3. Cooling coils too small. 3. Add surface area or replace. 4. Inadequate air circulation. 4. Improve air movement.

Suction line 1. Expansion valve passing excess 1. Adjust valve or replace with K frosted or refrigerant or is oversized. smaller valve. sweating 2. Expansion valve stuck open. 2. Clean valve or foreign particles, replace if necessary. 3. Evaporator fan not running. 3. Determine reason and correct. 4. Overcharge of refrigerant. 4. Correct charge.

Liquid line 1. Restriction in filter-drier or 1. Replace part. L frosted or strainer. sweating 2. Liquid shut-off (king-valve) 2. Open valve fully. partially closed.

Unit noisy 1. Loose parts or mounting. 1. Find and tighten. M 2. Tubing rattle. 2. Reform to be free of contact. 3. Bent fan blade causing vibration. 3. Replace blade. 4. Fan motor bearings worn. 4. Replace motor.

106

Tecumseh Products Company LLC 5683 Hines Drive Ann Arbor, MI 48108 800.211.3427 | 734.585.9500 www.tecumseh.com

©2017 Tecumseh Products Company. All rights reserved. Publication no. AF-110 Rev 1, 05/17