Application areas • HighresistantagainstambientairwithhumidityandIP65 Ingressprotectionrating. • Homogenouslight • Energysavingsupto80%(comparedluminairesthat useshalogen) • Replacehalogenlampswithfloodlightluminaires(up to750W) Benefits • Beamangle115° • Colourrenderingindex:CRI80+ • Colourtemperatures:3000,4000and5000K • Operatingfrequenzy:50/60Hz • Built-instaticdriver • Fixedmounting,1meterpre-cableconnectedtothefixture • Nominalvoltage:220-240V • L70B5025.000hourslifetimeat25°C • Ratedlumenupto9000lm • UV-free&IR-free • Operatingtemperature-20°Cto+40°C • Light-weight,upto2.23kg(100W) • Ultraslim Features aluminum housingwithsafetyglasscover,thefloodlightsareidealforoutdooruse. floodlights TungsramLEDFloodlightsuppliesimmediatelightwithoutstart-uporcoolingdowntimes.Thanksto arobust ing ofbuildingsaswelllightinggardens,pathsneartobuildings,garages,entrancewaysanddrives.Compared totraditional efficiency. Therangeissuitableforvariousapplicationswallmountedaroundbuildingfacades,idealtheclassic floodlight LED Floodlightisauniversal,compactrangeoffloodlightswithlumenoutputlevelsfrom800to9000and upto90LPW Product information G2 (ECO) LED Floodlight • housing colour:grey • housingmade ofdie-castaluminiumwith temperedglass Structures andmaterials IP65 IK05 Industrial CLASS I Garages Car park, Public areas facades Building areas Construction - DATA SHEET Specification summary

Beam System Product Product Wattage Lumen Efficacy IK Weight Description CCT (K) pattern CRI IP Code Code (DS) (W) (Lm) (lm/W) rating (kg) (°) rating

93115847 93115855 LED Flood G2 TU S 10W 840 SY ST GN 10 850 85 4000K 115 >80 IP65 05 0.284

93115848 93115856 LED Flood G2 TU S 30W 840 SY ST GN 30 2700 90 4000K 115 >80 IP65 05 1.085

93115849 93115857 LED Flood G2 TU S 50W 840 SY ST GN 50 4500 90 4000K 115 >80 IP65 05 1.529

93115850 93115858 LED Flood G2 TU S 100W 840 SY ST GN 100 9000 90 4000K 115 >80 IP65 05 2.223

93115851 TBD LED Flood G2 TU S 10W 830 SY ST GN 10 800 80 3000K 115 >80 IP65 05 0.284

93115852 TBD LED Flood G2 TU S 30W 830 SY ST GN 30 2550 85 3000K 115 >80 IP65 05 1.085

93115853 TBD LED Flood G2 TU S 50W 830 SY ST GN 50 4250 85 3000K 115 >80 IP65 05 1.529

93115854 TBD LED Flood G2 TU S 100W 830 SY ST GN 100 8500 85 3000K 115 >80 IP65 05 2.223

TBD 93115859 LED Flood G2 TU S 10W 850 SY ST GN 10 850 85 5000K 115 >80 IP65 05 0.284

TBD 93115860 LED Flood G2 TU S 30W 850 SY ST GN 30 2700 90 5000K 115 >80 IP65 05 1.085

TBD 93115861 LED Flood G2 TU S 50W 850 SY ST GN 50 4500 90 5000K 115 >80 IP65 05 1.529

TBD 93115862 LED Flood G2 TU S 100W 850 SY ST GN 100 9000 90 5000K 115 >80 IP65 05 2.223

Dimensions (mm)

Length Width Height Weight Wattage (mm) (mm) (mm) (kg)

10W 106 108 27 0.284 30W 250 173 42 1.085 50W 290 213 46 1.529 100W 345 250 48 2.223

Photometric data

105° 105° 105° 105° 105° 105° 105° 105°

90° 90° 90° 90° 90° 90° 90° 90°

75° 75° 75° 75° 75° 75° 75° 75°

60° 60° 60° 400 60° 60° 60° 60° 60°

160 800 1600

600

45° 45° 45° 45° 45° 45° 45° 45° 240 1200 2400

800

30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30°

cd 850 lm cd 2700 lm cd 4500 lm cd 9000 lm C0 - C180 C90 - C270 C0 - C180 C90 - C270 C0 - C180 C90 - C270 C0 - C180 C90 - C270 10W 30W 50W 100W

Photometry is based on LM79 Regulatory and standards Regulatory mark: CE Regulations: 2014/35/EU, 2014/30/EU, 2011/65/EU, (framework 2009/125/EC) EU/1194/2012 amended by EU 2015/1428, (framework 2010/30/EC) 874/2012 and 518/2014*, 2012/19/EU* Harmonised standards: EN 60598, EN 62493, EN 61547, EN55015, EN 61000, refer to CE Declaration of Conformity and Technical File for details Photobiological risk assessment group 0. The product is considered safe, does not pose any photobiological hazard. *not on DOC

Order logic

Internal Housing Gen. Brand Control System CRI CCT Reflector Voltage Special Shipment Code color

30 - 10W 3000K G2 - ST - N- DS - TU - S - 30W 40 - SY - G- LED Flood Genera- 8 - 80 220- Standard Direct Static 4000K Symetrical Grey tion 2 50W 240V version shipment 100W 50 - 5000K

Example: LED Flood G2 TU S 30W 840 SY ST GN 30W 80 CRI 4000K Floodlight with static driver and symmetrical optic in grey housing

We in Tungsram Operations Kft. are constantly developing and improving our products. For this reason, all product descriptions in this catalogue are intended as a general guide, and we may change specifications from time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, Tungsram cannot accept any liability arising from the reliance on such data to the extent permitted by law. LED Floodlight G2 ECO Datasheet - April 2020 tungsram.com GE Lighting

LED Floodlight SHEET DATA

CLASS IP65/66 IK07/08 I

Product information GE LED Floodlight is a universal, compact range of floodlights with six lumen output levels from 2.000 to 20.000lm and up to 130 LPW efficiency. The range is suitable for various applications wall mounted around building facades, ideal for the classic floodlighting of buildings as well as lighting gardens, paths near to buildings, garages, entrance ways and drives. Compared to traditional floodlights GE Floodlight supplies immediate light without start-up or cooling down times. Thanks to a robust aluminium housing with safety glass cover, the floodlights are ideal for outdoor use.

Features • High performance with outstanding efficiency with 6 lumen packages – up to 130 lm/W • L70/B50 @25C° 30 000 hours lifetime (20-50W) or 50 000 hours lifetime (75-150W) • 2 colour temperatures: 4000 and 6500K with SDCM<=6 • Wide beam angle: 100° (20-50W) or 120° (75-150W) • Robust aluminimum die-cast luminaire with high protection rating IP65 (20-50W) or IP66 (75-150W) and high impact resistance of IK07 (20-50W) or IK08 (75-150W) • Suitable for operation in ambient temperature of -20°C to +40°C (20-50W) or -30°C to +50°C (75-150W) • Static built-in driver • PF >0,9 • THD < 20% • Nominal Voltage: 220-240V • Operating frequency: 50-60Hz • Insulation Class I • Breather valve to maintain good ingress protection in case of over pressurization for 75-150W products

Benefits • Replacement for floodlight luminaires with halogen lamps (up to 1500W) • savings up to 90% (compared to luminaires that use halogen) • Homogenous light • High resistance against ambient air with humidity and high particle loads

Application areas

Industrial Car park, Garages Public areas

Building Construction areas facades Structures and materials • Body: housing made of die cast aluminium with tempered glass cover • Colour: black • Fixtures are pre-wired with 0.3 meter (20-50W) or 1 meter (75-150W) H05RN-F rubber cable • Easy mounting with bracket included in the package (angle max 160°)

Specification summary

DS Product Product Wattage Lumen Efficiency CCT IK IP Current Replacement Weight CRI Product Code Description (W) (lm) (lm/W) (K) rating rating (mA) for Halogen (kg) code 93081605 FL-YP1-2040-7S-BN 20 2 000 100 4 000 >80 IK07 IP65 92 0,62 93082107 160W 93082101 FL-YP1-2065-7S-BN 20 2 000 100 6 500 >80 IK07 IP65 92 0,62 93082113

93082096 FL-YP1-3040-7S-BN 30 3 000 100 4 000 >80 IK07 IP65 135 0,97 93082108 250W 93082102 FL-YP1-3065-7S-BN 30 3 000 100 6 500 >80 IK07 IP65 135 0,97 93082114

93082097 FL-YP1-5040-7S-BN 50 6 000 120 4 000 >80 IK07 IP65 230 1,14 93082109 400W 93082103 FL-YP1-5065-7S-BN 50 6 000 120 6 500 >80 IK07 IP65 230 1,14 93082115

93082098 FL-YP1-7540-7S-BN 75 10 000 133 4 000 >80 IK08 IP66 340 3,29 93082110 750W 93082104 FL-YP1-7565-7S-BN 75 10 000 133 6 500 >80 IK08 IP66 340 3,29 93082116

93082099 FL-YP1-11540-7S-BN 115 15 000 130 4 000 >80 IK08 IP66 520 4,20 93082111 1000W 93082105 FL-YP1-11565-7S-BN 115 15 000 130 6 500 >80 IK08 IP66 520 4,20 93082117

93082100 FL-YP1-15040-7S-BN 150 20 000 133 4 000 >80 IK08 IP66 700 5,33 93082112 1500W 93082106 FL-YP1-15065-7S-BN 150 20 000 133 6 500 >80 IK08 IP66 700 5,33 93082118

Dimensions (mm)

L

Type L (mm) W (mm) H (mm) FL-YP1-20... 163±1 35,5±1 163±1 FL-YP1-30... 203±1 36,0±1 202±1 FL-YP1-50... 223±1 35,5±1 216±1

H FL-YP1-75... 286±1 90,5±1 368±1 FL-YP1-115... 337±1 90,5±1 419±1 FL-YP1-150... 373±1 90,5±1 450±1 Photometric data

1 1 1 1 1 1

1

3 3

3

3 1 1 3 3 1 1 3 3 1 1 3 cdlm η 1 cdlm η 1 cdlm η 1 1 1 1 20W - 4000K 30W - 4000K 50W - 4000K

1 1 1 1 1 1

3 3 3

3 1 1 3 3 1 1 3 3 1 1 3 cdlm η 1 cdlm η 1 cdlm η 1 1 1 1 75W - 4000K 115W - 4000K 150W - 4000K

Regulatory and standards Regulatory mark: CE Regulations: 2014/35/EU, 2014/30/EU, 2011/65/EU, (framework 2009/125/EC) EU/1194/2012 amended by EU 2015/1428, (framework 2010/30/EC) 874/2012 and 518/2014*, 2012/19/EU* Harmonised standards: EN 60598, EN 62493, EN 61547, EN55015, EN 61000, refer to CE Declaration of Conformity and Technical File for details *not on DOC

Order logic

Internal System Housing Type Generation CCT Voltage Controller Special Code Wattage colour

20 30 N= YP = 50 40= 4000K 7 = FL = FLOOD 1 = Gen1 S= Static B= Black Standard Premium 220-240V 75 65= 6500K version 115 150

Example: FL-YP1-5040-7S-BN Gen1 50W 4000K Floodlight, Static, 220-240V built-in driver, standard version with black housing

GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general www.gelighting.com guide, and we may change specifications time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in and are both registered trademarks this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on of the such data to the extent permitted by law. LED Floodlight Data Sheet – February 2018 Application areas Floodlight LED 12M/110°),detectionrangeofdaylightsensor(0-1000lux) andswitchingtimecanbemodified. • IP65infraredmotion&daylightsensoroptionalforupto50Wproducts.Detectionrangeof(3M/180° or • Breathervalvetomaintaingoodingressprotectionincaseofoverpressurizationfor75-150Wproducts • InsulationClassI • Operatingfrequency:50-60Hz • NominalVoltage:220-240V • THD<20% • PF>0,9 • Staticbuilt-indriver • Suitableforoperationinambienttemperatureof-20°Cto+40°C(20-50W)or-30°C+50°C(75-150W) ofIK07(20-50W)orIK08(75-150W) • Robustaluminimumdie-castluminairewithhighprotectionratingIP65(20-50W)orIP66(75-150W)andimpact resistance • Widebeamangle:100°(20-50W)or120°(75-150W) • 2colourtemperatures:4000and6500KwithSDCM<=6 • 50000hoursL80B10lifetime@25°C • Highperformancewithoutstandingefficiency6lumenpackages–upto130lm/W Features robust aluminiumhousingwithsafetyglasscover,thefloodlightsareidealforoutdooruse. traditional floodlightsTungsramLEDFloodlightsuppliesimmediatelightwithoutstart-uporcoolingdowntimes. Thankstoa floodlighting ofbuildingsaswelllightinggardens,pathsneartobuildings,garages,entrancewaysanddrives. Comparedto LPW efficiency.Therangeissuitableforvariousapplicationswallmountedaroundbuildingfacades,ideal the classic LED Floodlightisauniversal,compactrangeoffloodlightswithsixlumenoutputlevelsfrom2.000to20.000lmandup Product information • Highresistanceagainstambientairwithhumidityand high particleloads • Homogenouslight • Energysavingsupto90%(comparedluminairesthat usehalogen) • Replacementforfloodlightluminaireswithhalogenlamps (upto1500W) Benefits IP65/66 Industrial IK07/08 CLASS I Garages Car park, Public areas facades Building areas Construction 130

DATA SHEET Structures and materials • Body: housing made of die cast aluminium with tempered glass cover • Colour: black • Fixtures are pre-wired with 0.3 meter (20-50W) or 1 meter (75-150W) H05RN-F rubber cable • Easy mounting with bracket included in the package (angle max 160°)

Specification summary

Repl. DS Wattage Lumen Efficiency IK IP Current Weight Product Code Description CCT (K) CRI for Product (W) (lm) (lm/W) rating rating (mA) (kg) Halogen code Standard version - Symmetric optic 93101677 LED Flood G1 TU S 20W 840 SY ST BN 20 2 000 100 4000 >80 IK07 IP65 92 0.62 93103709 160W 93107561 LED Flood G1 TU S 20W 865 SY ST BN 20 2 000 100 6500 >80 IK07 IP65 92 0.62 93103715

93101678 LED Flood G1 TU S 30W 840 SY ST BN 30 3 000 100 4000 >80 IK07 IP65 135 0.97 93103710 250W 93107562 LED Flood G1 TU S 30W 865 SY ST BN 30 3 000 100 6500 >80 IK07 IP65 135 0.97 93103716

93101679 LED Flood G1 TU S 50W 840 SY ST BN 50 6 000 120 4000 >80 IK07 IP65 230 1.14 93103711 400W 93107563 LED Flood G1 TU S 50W 865 SY ST BN 50 6 000 120 6500 >80 IK07 IP65 230 1.14 93103717

93101680 LED Flood G1 TU S 75W 840 SY ST BN 75 10 000 133 4000 >80 IK08 IP66 340 3.29 93103712 750W 93107564 LED Flood G1 TU S 75W 865 SY ST BN 75 10 000 133 6500 >80 IK08 IP66 340 3.29 93103718

93101681 LED Flood G1 TU S 115W 840 SY ST BN 115 15 000 130 4000 >80 IK08 IP66 520 4.20 93103713 1000W 93107565 LED Flood G1 TU S 115W 865 SY ST BN 115 15 000 130 6500 >80 IK08 IP66 520 4.20 93103719

93101683 LED Flood G1 TU S 150W 840 SY ST BN 150 20 000 133 4000 >80 IK08 IP66 700 5.33 93103714 1500W 93107566 LED Flood G1 TU S 150W 865 SY ST BN 150 20 000 133 6500 >80 IK08 IP66 700 5.33 93103720 Standard version - Asymmetric optic 93101682 LED Flood G1 TU S 115W 840 AS ST BN 115 14 500 126 4000 >80 IK08 IP66 520 5.33 -

93101684 LED Flood G1 TU S 150W 840 AS ST BN 150 18 000 120 4000 >80 IK08 IP66 700 5.33 - Motion sensor version - Symmetric optic 93107575 LED Flood G1 TU S 20W 840 SY ST BM 20 2 000 100 4000 >80 IK07 IP65 92 0.73 93103748 160W 93107577 LED Flood G1 TU S 30W 840 SY ST BM 20 2 000 100 6500 >80 IK07 IP65 92 0.73 93103750

93107579 LED Flood G1 TU S 50W 840 SY ST BM 30 3 000 100 4000 >80 IK07 IP65 135 1.08 93103752 250W 93107576 LED Flood G1 TU S 20W 865 SY ST BM 30 3 000 100 6500 >80 IK07 IP65 135 1.08 93103749

93107578 LED Flood G1 TU S 30W 865 SY ST BM 50 6 000 120 4000 >80 IK07 IP65 230 1.25 93103751 400W 93107580 LED Flood G1 TU S 50W 865 SY ST BM 50 6 000 120 6500 >80 IK07 IP65 230 1.25 93103753 Adjustable Accessories* 93090320 IP68 connector for Floodlight/DL01-3A

* accessories to be ordered separately Dimensions (mm) Standard version Motions sensor version

L L W

W H H 50 mm

59 mm 107 mm

Type L (mm) W (mm) H (mm) Type L (mm) W (mm) H (mm) LED Flood G1 TU S 20W...BN 163±1 35 163±1 LED Flood G1 TU S 20W...BM 224±1 35 163±1 LED Flood G1 TU S 30W...BN 203±1 35 202±1 LED Flood G1 TU S 30W...BM 264±1 35 202±1 LED Flood G1 TU S 50W...BN 223±1 35 216±1 LED Flood G1 TU S 50W...BM 284±1 35 216±1 LED Flood G1 TU S 75W...BN 286±1 91 368±1 LED Flood G1 TU S 115W...BN 337±1 91 419±1 LED Flood G1 TU S 150W...BN 373±1 91 450±1

Photometric data symmetric optic

105° 105° 105° 105° 105° 105°

90° 90° 90° 90° 90° 90°

75° 75° 75° 75° 75° 75°

60° 200 60° 60° 60° 60° 60° 200 160

300 45° 45° 45° 45° 45° 45° 300 240 400

400 320 500

30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30° cd/klm η = 100% cd/klm η = 100% cd/klm η = 100% C0 - C180 C90 - C270 C0 - C180 C90 - C270 C0 - C180 C90 - C270 20W - 4000K 30W - 4000K 50W - 4000K

105° 105° 105° 105° 105° 105°

90° 90° 90° 90° 90° 90°

75° 75° 75° 75° 75° 75°

60° 60° 60° 60° 60° 60° 200 200 200

45° 45° 45° 45° 45° 45° 300 300 300

400 400 400

30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30° cd/klm η = 100% cd/klm η = 100% cd/klm η = 100% C0 - C180 C90 - C270 C0 - C180 C90 - C270 C0 - C180 C90 - C270 75W - 4000K 115W - 4000K 150W - 4000K asymmetric optic

105° 105° 105° 105°

90° 90° 90° 90°

75° 75° 75° 75°

4000

60° 60° 60° 60° 6000 8000

8000

45° 45° 45° 45° 12000 10000

12000 16000

14000

30° 15° 0° 15° 30° 30° 15° 0° 15° 30°

cd 14993 lm cd 19991 lm C0 - C180 C90 - C270 C0 - C180 C90 - C270 G1 - 115W - 4000K G1 - 150W - 4000K

Regulatory and standards Regulatory mark: CE Regulations: 2014/35/EU, 2014/30/EU, 2011/65/EU, (framework 2009/125/EC) EU/1194/2012 amended by EU 2015/1428, (framework 2010/30/EC) 874/2012 and 518/2014*, 2012/19/EU* Harmonised standards: EN 60598, EN 62493, EN 61547, EN55015, EN 61000, refer to CE Declaration of Conformity and Technical File for details *not on DOC

Order logic

Internal Housing Gen. Brand Control System CRI CCT Reflector Voltage Special Shipment Code color

30 - 20W 3000K N- 30W SY - Standard G1 - Symetrical ST - version DS - TU - S - 50W 40 - B- LED Flood Genera- 8 - 80 220- Direct Tungsram Static 4000K Black tion 1 75W AS - 240V M- shipment 115W Assymetrical Sensor version 150W 65 - 6500K Example: LED Flood G1 TU S 50W 840 SY ST BN Gen1 50W 4000K Floodlight, Static, 220-240V built-in driver, standard version with black housing and symmetrical optic

We in Tungsram Operations Kft. are constantly developing and improving our products. For this reason, all product descriptions in this catalogue are intended as a general guide, and we may change specifications from time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, Tungsram cannot accept any liability arising from the reliance on such data to the extent permitted by law. LED Floodlight Datasheet - April 2020 tungsram.com