Diastolic Blood Pressure Is an Important Determinant of Augmentation Index and Pulse Wave Velocity in Young, Healthy Males

Total Page:16

File Type:pdf, Size:1020Kb

Load more

Journal of Human Hypertension (2003) 17, 153–158 & 2003 Nature Publishing Group All rights reserved 0950-9240/03 $25.00 www.nature.com/jhh ORIGINAL ARTICLE Diastolic blood pressure is an important determinant of augmentation index and pulse wave velocity in young, healthy males JNu¨ rnberger1, S Dammer1, A Opazo Saez2, T Philipp1 and RF Scha¨fers1 1Department of Nephrology, University of Essen, Essen, Germany; 2Department of Cellular and Integrative Physiology, Indiana University School of Medicine, Indianapolis, IN, USA Pulse wave velocity (PWV) and augmentation index are P ¼ 0.0002) and total peripheral resistance (r ¼ 0.266, widely used measures of arterial stiffness. The purpose P ¼ 0.0204). After multiple regression analysis, augmen- of this study was to evaluate the role of blood pressure tation index remained significantly correlated only to as a determinant of both indices independent of DBP (b ¼ 0.347, P ¼ 0.0051). Using simple regression potentially confounding factors including gender, age analysis, PWV was correlated to age (r ¼ 0.304, and cardiovascular disorders. A total of 77 young, P ¼ 0.0067), systolic blood pressure (r ¼ 0.280, healthy subjects were investigated under resting condi- P ¼ 0.0129). DBP (r ¼ 0.455, Po0.0001), MAP (r ¼ 0.446, tions. Augmentation index was derived by pulse wave Po0.0001) and heart rate (r ¼ 0.348, P ¼ 0.0018). After analysis using carotid applanation tonometry. PWV was multiple regression analysis, PWV remained correlated determined from pressure tracing over the carotid and only to age (b ¼ 0.218, P ¼ 0.0422) and DBP (b ¼ 0.4105, femoral artery. The relations between stiffness markers P ¼ 0.0316). In summary, DBP is an important determi- and haemodynamic parameters were analysed by sim- nant of augmentation index and PWV in young, healthy ple (r) and multiple (b) regression analysis. Using simple males. Further studies are needed to characterize the regression analysis, augmentation index was correlated impact of blood pressure on arterial stiffness in other to age (r ¼ 0.292, P ¼ 0.0105), diastolic blood pressure populations including females and older subjects. (DBP, r ¼ 0.483, Po0.0001), mean arterial blood pressure Journal of Human Hypertension (2003) 17, 153–158. (MAP, r ¼ 0.381, P ¼ 0.0007), pulse pressure (r ¼À0.414, doi:10.1038/sj.jhh.1001526 Keywords: augmentation index; pulse wave velocity; diastolic blood pressure; arterial stiffness Introduction ness have been developed such as characteristic impedance,8,9 PWV constitutes one of the most Stiffening of the arterial wall is an inevitable process 1 widely used surrogates of arterial stiffness. that occurs during ageing and is one major Recently, a new technique, pulse wave analysis, mechanism responsible for morbidity and mortality 2,3 has been developed that offers a simple way to in cardiovascular disease. Thus, measuring arter- measure arterial function.1 Pulse pressure waves are ial stiffness has become a widely used tool for recorded at a single conveniently exposed artery, investigating the function of large arteries in such as the carotid artery, and used to calculate aug- epidemiological and clinical studies. Arterial stiff- mentation index, a measure that reflects the degree ness has been traditionally assessed by measuring 4,5 to which central arterial pressure is enhanced by pulse wave velocity (PWV), which has been wave reflection of the pulse wave.1 This new shown to predict cardiovascular mortality in pa- technique is reproducible, noninvasive and increas- tients with essential hypertension and chronic renal 10,11 6,7 ingly used in clinical studies. failure. Although other measures of arterial stiff- A number of nonpathological factors influence augmentation index and PWV. It has been consis- tently reported that age,1,12 height,13,14 heart rate15,16 Correspondence: Dr R.F. Scha¨fers, Division of Nephrology, School and gender12,14 influence augmentation index, of Medicine, University of Essen, Hufelandstrasse 55, 45122 whereas PWV appears to be a more robust stiffness Essen, Germany. measure influenced by fewer factors including age1,5 E-mail: [email protected] 17 Received 16 August 2002; revised 6 November 2002; accepted 13 and heart rate. However, despite the wide use November 2002 of both augmentation index and PWV, there are Arterial stiffness and diastolic blood pressure JNu¨rnberger et al 154 controversial results in the literature regarding the electrocardiogram and routine laboratory screening. relation between both stiffness measures and blood Investigations were carried out in the Department of pressure, the classical haemodynamic parameter. Nephrology at the University of Essen, Germany. In some studies, augmentation index was found to The study was approved by the Ethics Committee of be correlated to diastolic blood pressure (DBP) but the University of Essen Medical School and was in not systolic blood pressure (SBP).18,19 Other studies accordance with the principles laid down in the reported that augmentation index was correlated to Declaration of Helsinki. both SBP and DBP20 or only to SBP.21,22 Interestingly, Measurements were performed in a quiet, tem- Cameron et al 21 found in a study population of 262 perature-controlled (241C) room. On the study day, hypertensive subjects that augmentation index was volunteers reported to the laboratory at 7–8 a.m. correlated to DBP only in males and that this after an overnight fast to eliminate postprandial relation was lost when augmentation index was haemodynamic changes. During the investigation, normalised for age. There are also inconsistent subjects remained in the supine position. Each sub- results in studies only measuring mean blood ject was instrumented with a blood pressure cuff pressure. London et al 23 found augmentation index and tape electrodes to measure transthoracic im- to be correlated to mean arterial pressure in patients pedance. After a period of 30 min of complete rest, with end-stage renal failure. In contrast, Wilkinson haemodynamic measurements were performed. All et al 24 did not find a correlation between augmenta- measurements were taken by the same investigator. tion index and mean arterial blood pressure in subjects with diabetes mellitus type 1. There is also conflicting evidence in the literature regarding Anthropometric and haemodynamic parameters the relation between PWV and blood pressure. Some studies showed that PWV was only correlated Height and weight were measured and body mass to SBP.22,25 Others found that PWV was correlated index (BMI) was calculated as weight to height to both SBP and DBP18 or was correlated to SBP in squared. Blood pressure (mmHg) was measured both men and women, but was correlated to DBP with a standard mercury sphygmomanometer with only in women.26 the disappearance of Korotkow’s sound defined as The controversial results reported in the literature DBP. Pulse pressure (PP) was calculated by sub- may be attributed to the large variability in the stracting DBP from SBP. Mean arterial pressure population studied, such as the broad age range, (MAP) was defined as DBP plus one-third of PP. gender distribution and the presence of different Heart rate (HR) (bpm) was calculated from the RR- diseases or drug regimens. Additionally, age-related interval of the electrocardiogram, which was re- changes in the vasculature including a widening corded using a Siemens-Cardirexs multichannel ink of pulse pressure,27 changes in heart rate, blood jet recorder (Siemens Medizintechnik, Erlangen, pressure and vascular resistance28 may further Germany) as previously described.29,30 complicate the evaluation of stiffness determinants. We used impedance cardiography to measure These controversial results suggest that it is neces- central haemodynamics. Impedance cardiography sary to identify the determinants of arterial stiffness agrees closely with measurements obtained by markers in the absence of the potential contribution Doppler echocardiography or thermodilution,31 of age, gender or disease-related changes of the and is acceptable for clinical use particularly in vasculature. studies investigating young subjects free from any The purpose of the present study was to evaluate cardiovascular disease.32 In our laboratory, we have the role of blood pressure as a determinant of determined that the variability of stroke volume augmentation index and PWV in a homogeneous measured by impedance cardiography is less than population of young, healthy males. We also 5.5% (expressed as coefficient of variation).30 Stroke measured central haemodynamics including stroke volume (SV) (ml) was measured by impedance volume, cardiac output and total peripheral resis- cardiography using the standard approach with tance. We found that DBP but not SBP is strongly circular tape electrodes and graphical signal analy- correlated to both augmentation index and PWV. sis according to Kubicek’s equation.33 A ‘Kardio- Dynagraph’ was used to record changes in trans- thoracic impedance (Heinz Diefenbach Elektrome- Materials and methods dizin, Frankfurt, Germany). Cardiac output (CO) À1 Study population and protocol (1  min ) was calculated as CO ¼ HR  SV/1000. Total peripheral resistance (TPR) (dyne  s  cmÀ5) The study population included 77 young (23–35 was calculated as MAP divided by CO. years old), male volunteers who gave informed, Pulse transmission time (ms) was determined written consent. Only male subjects were selected noninvasively from pressure tracings over the because augmentation index has been shown to
Recommended publications
  • Theoretical Biology and Medical Modelling Biomed Central

    Theoretical Biology and Medical Modelling Biomed Central

    Theoretical Biology and Medical Modelling BioMed Central Research Open Access The velocity of the arterial pulse wave: a viscous-fluid shock wave in an elastic tube Page R Painter Address: Office of Environmental Health Hazard Assessment, California Environmental Protection Agency, P. O. Box 4010, Sacramento, California, 95812, USA Email: Page R Painter - [email protected] Published: 29 July 2008 Received: 11 April 2008 Accepted: 29 July 2008 Theoretical Biology and Medical Modelling 2008, 5:15 doi:10.1186/1742-4682-5-15 This article is available from: http://www.tbiomed.com/content/5/1/15 © 2008 Painter; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Abstract Background: The arterial pulse is a viscous-fluid shock wave that is initiated by blood ejected from the heart. This wave travels away from the heart at a speed termed the pulse wave velocity (PWV). The PWV increases during the course of a number of diseases, and this increase is often attributed to arterial stiffness. As the pulse wave approaches a point in an artery, the pressure rises as does the pressure gradient. This pressure gradient increases the rate of blood flow ahead of the wave. The rate of blood flow ahead of the wave decreases with distance because the pressure gradient also decreases with distance ahead of the wave. Consequently, the amount of blood per unit length in a segment of an artery increases ahead of the wave, and this increase stretches the wall of the artery.
  • Pulse Wave Velocity As a Marker of Arteriosclerosis and Its Comorbidities in Chinese Patients

    Pulse Wave Velocity As a Marker of Arteriosclerosis and Its Comorbidities in Chinese Patients

    237 Hypertens Res Vol.30 (2007) No.3 p.237-242 Original Article Pulse Wave Velocity as a Marker of Arteriosclerosis and Its Comorbidities in Chinese Patients Xiao-Ning LIU1), Hai-Qing GAO1), Bao-Ying LI1), Mei CHENG1), Ya-Bing MA1), Zhi-Mian ZHANG2), Xi-Mei GAO2), Yuan-Ping LIU1), and Min WANG1) To obtain reliable data on the epidemiology of arteriosclerosis and the comorbidities in patients with hyper- tension (HP), coronary heart disease (CHD), type 2 diabetes mellitus (T2DM) and stroke, we evaluated the clinical significance of pulse wave velocity (PWV) as an indicator of arteriosclerosis and its comorbidities in Chinese patients. A total of 910 subjects, including 748 Chinese patients with one or more cardiovascular risk factors (80.2% male, mean age 73.69±5.03 years) and 162 healthy volunteers (78.4% male, mean age 73.60±5.32 years) were recruited into the study. PWV was measured in 910 subjects, and large artery arte- riosclerosis was defined as PWV ≥12 m/s. Multivariable logistic regression analyses were performed to iden- tify risk factors associated with arteriosclerosis. The prevalence of large artery arteriosclerosis in the patients overall was 67.4%, and the prevalence was higher in patients with than in those without HP (63.3% vs. 34.0%; odds ratio [OR]: 3.451), T2DM (24.8% vs. 11.1%; OR: 2.854), CHD (56.1% vs. 45.1%; OR: 1.246) and stroke (26.6% vs. 19.2%; OR: 1.236), but the OR values of CHD and stroke did not differ significantly (p>0.05). After multiple logistic regression analysis, female sex, older age, HP and T2DM were risk factors for large artery arteriosclerosis.
  • The Effect of Blood Pressure Alteration on the Pulse Wave Velocity

    The Effect of Blood Pressure Alteration on the Pulse Wave Velocity

    Br Heart J: first published as 10.1136/hrt.26.2.261 on 1 March 1964. Downloaded from Brit. Heart J., 1964, 26, 261. THE EFFECT OF BLOOD PRESSURE ALTERATION ON THE PULSE WAVE VELOCITY BY E. R. NYE From the Wellcome Research Institute, Dunedin, New Zealand Received January 21, 1963 Determinations of the pulse wave velocity (PWV) in living subjects have shown that higher values are found with increasing age (Rahier, 1961; Simonson and Nakagawa, 1960) and in the presence of hypertension, with or without presumed atherosclerosis, but more so in the former case (Miasnikov, 1960). Woolam et al. (1962) have also shown higher values in diabetics with presumed atherosclerosis, compared with normal subjects. Comparison of PWV values obtained by different workers is difficult because of the variable techniques employed and different criteria used in estimating the length of the vessel over which the recordings were made; in addition not all workers have used the same vessels for their measurements, or the same events in the cardiac cycle for timing purposes. It may be assumed further that record- ings are usually carried out with the patient in the supine position but this is not always specified. Attention to these points is essential in considering what importance to attach to differences in figures given by various authors in reported PWV measurements. It is noted for example that the "normal" values quoted by Miasnikov are lower than those of Rahier's series by almost two metres. http://heart.bmj.com/ per second for subjects in their third decade. The values of PWV measured in peripheral vessels are higher than corresponding measurements in the aorta.
  • Relationship Between Arterial Pressure and Pulse Wave Velocity Using Photoplethysmography During the Post-Exercise Recovery Period

    Relationship Between Arterial Pressure and Pulse Wave Velocity Using Photoplethysmography During the Post-Exercise Recovery Period

    Acta Universitatis Latviensis, 2009, Vol. 753, Biology, pp. 59–68 Relationship between arterial pressure and pulse wave velocity using photoplethysmography during the post-exercise recovery period Zbignevs Marcinkevics1*, Mara Greve1, Juris Imants Aivars1, Renars Erts2, Aram Hussain Zehtabi1 1Department of Human and Animal Physiology, Faculty of Biology, University of Latvia, Kronvalda Bulv. 4, Riga LV-1586, Latvia 2Institute of Atomic Physics and Spectroscopy, University of Latvia, Skunu 4, Riga LV-1586, Latvia *Corresponding author, E-mail: [email protected] Abstract Blood pressure is an important parameter for health assessment. Noninvasive continuous beat per beat blood pressure measurement is still a complicated and expensive procedure. There is a lack of agreement on the optimal blood pressure measurement technique. Potentially the most useful indirect parameter for blood pressure monitoring could be pulse wave velocity or the inverse – pulse transit time. The objectives of the study was to determine the relationship between blood pressure and pulse wave velocity under conditions when different cardiovascular parameters change independently but simultaneously with blood pressure and to clarify whether there is a difference in relationship between blood pressure and pulse wave velocity measured by two different methods in different vascular beds. We determined the relationship between arterial blood pressure (systolic, mean) and the pulse wave velocity from 20 healthy volunteers during a post-exercise recovery period after a load cycling test. A significant correlation (p < 0.05) and regression (p < 0.001) between arterial pressure and pulse wave velocity was obtained. Pulse wave velocity measurement measured in different vascular beds showed no impact on correlation of arterial blood pressure and pulse wave velocity.
  • Withings Body Cardio Versus Gold Standards of Pulse-Wave Velocity and Body Composition

    Withings Body Cardio Versus Gold Standards of Pulse-Wave Velocity and Body Composition

    Journal of Personalized Medicine Article Withings Body Cardio Versus Gold Standards of Pulse-Wave Velocity and Body Composition Scott R. Collier 1,*, Conner McCraw 1, Megan Campany 1, Austin Lubkemann 1, Price StClair 1, Hong Ji 2, Kathryn Sandberg 2, Joseph W. Morgan 1 and Caroline J. Smith 1 1 Department of Health and Exercise Science, Appalachian State University, Boone, NC 28608, USA; [email protected] (C.M.); [email protected] (M.C.); [email protected] (A.L.); [email protected] (P.S.); [email protected] (J.W.M.); [email protected] (C.J.S.) 2 Department of Medicine, Georgetown University, Washington, DC 20008, USA; [email protected] (H.J.); [email protected] (K.S.) * Correspondence: [email protected]; Tel.: +828-262-7145 Received: 11 February 2020; Accepted: 6 March 2020; Published: 11 March 2020 Abstract: Home blood pressure monitors are widely used by consumers yet cardiovascular health may be better defined by pulse-wave velocity (PWV). So far, the Withings Body Cardio scale is the only consumer device that has been designed to measure PWV and body composition, including fat mass (FM) and fat-free mass (FFM), in the home setting. While one study has demonstrated that this device meets the acceptable accuracy standards of the ARTERY Society, no study has accounted for the gravitational effect of standing on a scale on aortic-leg PWV. Purpose: The purpose of this study was to assess the accuracy of PWV and body composition as determined by the Body Cardio scale. Methods: Measurements of PWV and body composition in healthy, young males and females (n = 20) using the Body Cardio device were compared to PWV assessed by applanation tonometry (SphygmoCor) and body composition analysis determined by air displacement plethysmography (Bod Pod).
  • Physics of Within-Tissue Wave Propagation Generated by Pulse Propagation in the Carotid Artery

    Physics of Within-Tissue Wave Propagation Generated by Pulse Propagation in the Carotid Artery

    applied sciences Article Physics of Within-Tissue Wave Propagation Generated by Pulse Propagation in the Carotid Artery 1, , 1,2, 1 3 Daniela Tommasin * y , Annette Caenen y, Benedict Verhegghe , Steve Greenwald and Patrick Segers 1 1 IBiTech-bioMMeda, Ghent University, 9000 Ghent, Belgium 2 Biomedical Engineering, Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, 3015GD Rotterdam, The Netherlands 3 Blizard Institute, Queen Mary University of London, London E1 2AT, UK * Correspondence: [email protected]; Tel.: +32-93-324-198 Daniela Tommasin and Annette Caenen equally contributed to the manuscript. y Received: 18 May 2019; Accepted: 16 July 2019; Published: 18 July 2019 Abstract: (1) Background: We aimed to assess the validity of laser Doppler vibrometry (LDV) as an emerging method to measure the local pulse wave velocity (PWV) from skin displacement generated by the pressure pulse inside an underlying artery. (2) Methods: A finite element model representing a simplified common carotid artery embedded within a soft tissue mimicking material was used to reproduce how tissue motions due to a wave propagation along the artery radiates to the skin surface. A parametric study was set up, varying: (i) the pressure conditions inside the artery (shock and traveling pressure impulse), (ii) the arterial depth and (iii) the geometry in a patient-specific artery model. (3) Results: under all conditions, the arterial pulse induced primary and secondary waves at the skin surface; of which the propagation speed deviated from the imposed PWV (deviations between 5.0% to 47.0% for the primary wave front). (4) Conclusions: the propagation of a short pressure − impulse induced complex skin displacement patterns revealing a complicated link between PWV and measured propagation speeds at the skin surface.
  • A Physics Based Approach to the Pulse Wave Velocity Prediction in Compliant Arterial Segments

    A Physics Based Approach to the Pulse Wave Velocity Prediction in Compliant Arterial Segments

    Journal of Biomechanics ∎ (∎∎∎∎) ∎∎∎–∎∎∎ Contents lists available at ScienceDirect Journal of Biomechanics journal homepage: www.elsevier.com/locate/jbiomech www.JBiomech.com A physics based approach to the pulse wave velocity prediction in compliant arterial segments Alexander S. Liberson n, Jeffrey S. Lillie, Steven W. Day, David A. Borkholder Rochester Institute of Technology, James E. Gleason Building, 76 Lomb Memorial Drive, Rochester, NY 14623-5604, United States article info abstract Article history: Pulse wave velocity (PWV) quantification commonly serves as a highly robust prognostic parameter Accepted 12 September 2016 being used in a preventative cardiovascular therapy. Being dependent on arterial elastance, it can serve as a marker of cardiovascular risk. Since it is influenced by a blood pressure (BP), the pertaining theory can Keywords: lay the foundation in developing a technique for noninvasive blood pressure measurement. Previous Blood pressure studies have reported application of PWV, measured noninvasively, for both the estimation of arterial Pulse wave velocity compliance and blood pressure, based on simplified physical or statistical models. A new theoretical Nonlinear 1D model model for pulse wave propagation in a compliant arterial segment is presented within the framework of fl Convective uid phenomena pseudo-elastic deformation of biological tissue undergoing finite deformation. An essential ingredient is Hyperelasticity the dependence of results on nonlinear aspects of the model: convective fluid phenomena, hyperelastic constitutive relation, large deformation and a longitudinal pre-stress load. An exact analytical solution for PWV is presented as a function of pressure, flow and pseudo-elastic orthotropic parameters. Results from our model are compared with published in-vivo PWV measurements under diverse physiological conditions.
  • Relation Between Blood Pressure and Pulse Wave Velocity for Human Arteries

    Relation Between Blood Pressure and Pulse Wave Velocity for Human Arteries

    Relation between blood pressure and pulse wave velocity for human arteries Yinji Maa,b,1, Jungil Choic,d,e,1, Aurélie Hourlier-Fargettec,d,e, Yeguang Xuec,d,f,g, Ha Uk Chungd,e, Jong Yoon Leed,e, Xiufeng Wangh, Zhaoqian Xiec,d,f,g, Daeshik Kangi, Heling Wangc,d,f,g, Seungyong Hani, Seung-Kyun Kangj, Yisak Kangk, Xinge Yul, Marvin J. Slepianm, Milan S. Rajd, Jeffrey B. Modeld, Xue Fenga,b, Roozbeh Ghaffarid,e,n, John A. Rogersc,d,e,g,n,o,p,q,r,s,t,u,2, and Yonggang Huangc,d,f,g,2 aDepartment of Engineering Mechanics, Tsinghua University, 100084 Beijing, China; bCenter for Flexible Electronics Technology, Tsinghua University, 100084 Beijing, China; cDepartment of Materials Science and Engineering, Northwestern University, Evanston, IL 60208; dCenter for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208; eSimpson Querrey Institute for Bio-Nanotechnology, Northwestern University, Evanston, IL 60208; fDepartment of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208; gDepartment of Mechanical Engineering, Northwestern University, Evanston, IL 60208; hSchool of Materials Science and Engineering, Xiangtan University, 411105 Hunan, China; iDepartment of Mechanical Engineering, Ajou University, 16499 Suwon-si, Republic of Korea; jDepartment of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, 34141 Daejeon, Republic of Korea; kDepartment of Electrical and Computer Engineering, University of Illinois at Urbana–Champaign, Urbana, IL 61801; lDepartment of Biomedical Engineering,
  • Blood Pressure and Pulse Wave Velocity Measurement for Operant Conditioning of Autonomic Responding*

    Blood Pressure and Pulse Wave Velocity Measurement for Operant Conditioning of Autonomic Responding*

    Behavior Research Methods &Instrumentation 1974, Vol. 6 (4), 393-397 Blood pressure and pulse wave velocity measurement for operant conditioning of autonomic responding* G. C. JERNSTEDT Dartmouth College, Hanover, New Hampshire 03755 and JEFFREY P. NEWCOMER School ofMedicine, Boston University, Boston, Massachusetts 02215 Presently available procedures for measuring blood pressure are not completely satisfactory for Es wishing to investigate the operant conditioning of cardiovascular activity. A system is described for measuring a correlate of the blood pressure information obtained with conventional sphygmomanometric systems. The procedure involves the measurement of speed of propagation through the arterial system of the pressure pulse from the heart's contraction. This speed, the pulse wave velocity, is closely related to cuff-derived blood pressure. Many of the problems present with current sphygmomanometric systems are absent with this apparatus and procedure. The apparatus can be assembled from common instruments or constructed from integrated circuits. Data collected with the apparatus confirm earlier studies which indicate that pulse wave velocity is correlated with sphygmomanometrically measured blood pressure and is a valuable cardiovascular response measure. Operant conditioning techniques have been employed provide information about a response: (a) immediately to train animals to effect changes in a great variety of after the response, (b) continuously over long periods of responses mediated by the autonomic nervous system time without necessary interruption, (c) with allowance (cf. Miller & Banuazizi, 1968). Operant techniques have for E control of feedback to the S about the response also been used successfully in controlling autonomic and reinforcement, (d) reliably and simply, (e) without responses with human Ss, particularly responses of the alteration of the response being measured, and (f) if cardiovascular system (cf.
  • Aortic Pulse Wave Velocities Using Real-Time Phase-Contrast MRI

    Aortic Pulse Wave Velocities Using Real-Time Phase-Contrast MRI

    Send Orders for Reprints to [email protected] The Open Medical Imaging Journal, 2015, 9, 9-14 9 Open Access Aortic Pulse Wave Velocities Using Real-Time Phase-Contrast MRI Arun A. Josepha,b, Martin Fasshauserc, Klaus-Dietmar Merboldta and Jens Frahma,b,* aBiomedizinische NMR Forschungs GmbH am Max-Planck-Institut für biophysikalische Chemie, Göttingen, Germany bDZHK, German Center for Cardiovascular Research, partner site Göttingen, Germany cAbteilung Diagnostische Radiologie, Universitätsmedizin, Göttingen, Germany Abstract: Purpose: To evaluate aortic pulse wave velocities obtained by real-time phase-contrast (PC) MRI in compari- son to cine PC MRI. Methods: Real-time PC MRI of eight healthy volunteers employed highly undersampled radial FLASH sequences and phase-sensitive image reconstructions by regularized nonlinear inversion (NLINV) at 40 ms temporal resolution and 1.3 mm in-plane resolution. Pulse wave velocities were analyzed for combinations of 2, 3 and 4 locations of aortic flow using time-to-upslope and cross-correlation methods. Results: For the time-to-upslope analysis mean pulse wave velocities ranged from 3.5 to 3.9 m s-1 for real-time PC MRI and from 3.5 to 3.8 m s-1 for cine PC MRI. A cross-correlation analysis of the same data resulted in 2.9 to 3.3 m s-1 and 3.3 to 3.7 m s-1, respectively. Conclusion: Real-time PC MRI determined aortic pulse wave velocities from single cardiac cycles in close correspond- ence to values obtained by cine PC MRI. Keywords: Real-time MRI, Phase-contrast MRI, Pulse wave velocity, Blood flow.
  • Relationship Between Blood Pressure Parameters and Pulse Wave Velocity in Normotensive and Hypertensive Subjects: Invasive Study

    Relationship Between Blood Pressure Parameters and Pulse Wave Velocity in Normotensive and Hypertensive Subjects: Invasive Study

    Journal of Human Hypertension (2007) 21, 141–148 & 2007 Nature Publishing Group All rights reserved 0950-9240/07 $30.00 www.nature.com/jhh ORIGINAL ARTICLE Relationship between blood pressure parameters and pulse wave velocity in normotensive and hypertensive subjects: invasive study EJ Kim1, CG Park1, JS Park1, SY Suh1, CU Choi1, JW Kim1, SH Kim2, HE Lim1, SW Rha1, HS Seo1 and DJ Oh1 1Division of Cardiology, Department of Internal Medicine, Korea University Guro Hospital, Guro-gu, Seoul, Republic of Korea and 2Division of Cardiology, Department of Internal Medicine, Hallym University Medical Center, Youngdeungpo-dong, Seoul, Republic of Korea Blood pressure (BP) is one of the most important (MAP) showed significant association with PWV. To contributing factors to pulse wave velocity (PWV), a avoid multiple colinearity among SBP, PP and MAP, we classic measure of arterial stiffness. Although there performed multiple regression analysis predicting PWV have been many non-invasive studies to show the thrice. Age, DM and each BP were significantly and relation between arterial stiffness and BP, the results consistently correlated to PWV. In the first and third are controversial. The aim of this study is to evaluate modules, compared to age, SBP and MAP were less the role of BP as an influencing factor on PWV using strong predictors, respectively. However, PP was the invasive method. We observed 174 normotensive stronger predictor than age and DM in the second and untreated hypertensive subjects using coronary module. Lastly, we simultaneously forced MAP and PP angiography. Arterial stiffness was assessed through with other variables in the fourth multivariate analysis.
  • Parameters Describing the Pulse Wave

    Parameters Describing the Pulse Wave

    Physiol. Res. 58: 473-479, 2009 MINIREVIEW Parameters Describing the Pulse Wave D. KORPAS, J. HÁLEK, L. DOLEŽAL Department of Medical Biophysics, Faculty of Medicine, Palacký University Olomouc, Czech Republic Received December 8, 2007 Accepted July 2, 2008 On-line July 25, 2008 Summary transformation between kinetic and potential energy of Pulse wave analysis permits non-invasive assessment of arterial each segment of ejected blood. On each artery or venous elasticity indices. The contour varies in different parts of the section affected by a pulse wave, three coherent circulation. It depends on physiological or pathophysiological phenomena can be observed: blood flow (flow pulse), the conditions of the organism. The pathological events like increase of blood pressure (pressure pulse) and extension arteriosclerosis or diabetes have a primary effect to the artery of transverse profile (profile or volume pulse). Several elasticity. Hypertension or some heart diseases also influence the invasive methods are available to detect the PW. The PW pulse wave velocity and resulted in earlier wave reflections. contour varies in different parts of the circulation. It There are several methods of pulse wave measurements based depends on physiological or pathophysiological on different principles and depending on the type of measured conditions of the organism. The heart rate, the body pulse wave. The evaluation parameters can be assessed from the height and the age (Filipovsky et al. 2000), as well as time domain, derivations, velocity or frequency domain. The main BMI or body fat (Wykretowicz et al. 2007) belong to aim of this review article is to offer a recent overview of pulse important physiological phenomena.