Code for Protection Against Lightning

Total Page:16

File Type:pdf, Size:1020Kb

Code for Protection Against Lightning CODE FOR PROTECTION AGAINST LIGHTNING Miscellaneous Publication of the Bureau of Standards No. 92 DEPARTMENT OF COMMERCE BUREAU OF STANDARDS MISCELLANEOUS PUBLICATION, BUREAU OF STANDARDS, No. 92 CODE FOR PROTECTION AGAINST LIGHTNING April 8, 1929 Approved April 4, 1929, by the American Standards Association PRICE 25 CENTS UNITED STATES GOVERNMENT PRINTING OFFICE WASHINGTON : 1929 MEMBERS OF THE SECTIONAL COMMITTEE Sponsors: American Institute of Electrical Engineers. National Bureau of Standards. NAME AND BUSINESS AFFILIATION ORGANIZATION REPRESENTED *M. G. Lloyd (chairman), Bureau of Standards, National Bureau of Standards. Washington, D. C. *F. W. Peek, jr. (vice chairman), General Electric American Institute of Electrical Engi- Co., Pittsfield, Mass. neers. *0. S. Peters (secretary), Bureau of Standards, National Bureau of Standards. Washington, D. C. W. R. Arbuckle, superintendent of fire alarm, International Association of Municipal Bayonne, N. J. Electricians. A. L. Atherton, Westinghouse Electric & Manu- American Institute of Electrical Engi- facturing Co., East Pittsburgh, Pa. neers. *W. C. Beckjord, American Light & Traction Co., American Gas Association. New York, N. Y. J. C. Bogle, Cook Electric Co., Chicago, 111 United States Independent Telephone Association. Bureau of Construction and Repair, Navy De- United States Navy Department. partment, Washington, D. C. W. L. Cook, Reliable Electric Co., Chicago, ni._. United States Independent Telephone Association. R. N. Covert, United States Weather Bureau, United States Weather Bureau. Washington, D. C. *H. W. Drake, Western Union Telegraph Co., Western Union Telegraph Co. New York, N. Y. Frank E. Epps, Tidewater Oil Co., New York, National Safety Council. N. Y. (Alternate: William F. Rooney.) V. E. Goodwin, General Electric Co., Pittsfield, National Electrical Manufacturers' As- Mass, sociation. *F. L. Hunt, Turners Falls Power & Electric Co., American Institute of Electrical En- Greenfield, Mass. gineers. Holger Jensen, Maryland Casualty Co., Balti- National Bureau of Casualty and more, Md. Surety Underwriters. S. D. Kretzer, St. Louis Lightning Rod Co., St. National Lightning Rod Manufacturers Louis, Mo. Association. •Member of Executive Committee. Ill IV MEMBERS OP THE SECTIONAL COMMITTEE NAME AND BUSINESS AFFILIATION OBGANIZATION REPRESENTED F. McVittie, New York State Railways, Roch- American Electric Railway Association. ester, N. Y. (Alternate: P. V. C. See.) J. L. Niesse, C. C. C. & St. L. Railway, Indian- American Railway Association. apolis, Ind. P. Norton, Western Electric Co., New York, Western Electric Co. N. Y. J. P. O'Donohue, Postal Telegraph-Cable Co., Postal Telegraph-Cable Co. New York, N. Y. (Alternate: D. H. Gage.) Dana Pierce, Underwriters' Laboratories, Chi- Underwriters' Laboratories (Inc.). cago, 111. (Alternate: B. H. Glover.) D. W. Roper, Commonwealth Edison Co., Chi- National Electric Light Association. cago, 111. (Alternates: A. Maxwell and E. C. Stone.) E. R. Scales, Edison Lamp Works, Harrison, American Society of Safety Engineers- N. J. Engineering Section, National Safety Council. •A.M. Schoen, South-Eastern Underwriters Asso- National Fire Protection Association and ciation, Atlanta, Ga. American Institute of Architects. W. C. Shinn, W. C. Shinn Manufacturing Co., National Lightning Rod Manufacturers' Chicago, 111. Association. F B. Silsbee, Bureau of Standards, Washington, National Bureau of Standards. D. C. *C. E. Skinner, Westinghouse Electric & Manu- American Petroleum Institute. facturing Co., East Pittsburgh, Pa. Thomas Sproule, Public Service Electric & Gas National Electric Light Association. Co., Newark, N. J. (Alternate: R. N. Conwell.) E. R. Stbtts, Dodd & Struthers, Des Moines, National Lightning Rod Manufacturers' Iowa. Association. H. S. Warren, American Telephone & Telegraph American Telephone & Telegraph Co. Co., New York, N. Y. W. C. Wagner, Philadelphia Electric Co., Phila- Association of Edison Illuminating Com- delphia, Pa. panies. Member of Executive Committee. PREFACE The protection of persons and property against lightning is a subject of widespread interest and of considerable im- portance. Since the time of Benjamin Franklin the value of lightning rods in the protection of buildings has been recog- nized. Early in the art of utilization of electrical energy, the use of lightning arresters in connection with exposed overhead lines was introduced. In the fields of both build- ings and electrical equipment there has been a great variety of practice, and many installations have been made which did not adequately fulfill the purpose for which they were intended. In order to meet the definite need for standards of prac- tice in connection with lightning protection, the American Engineering Standards Committee included in the first list of safety codes on its program a code of practice on this subject. The American Institute of Electrical Engineers and the National Bureau of Standards were designated as sponsors for this project, whose scope included the protec- tion of buildings, oil tanks and other structures, trees, live- stock, and persons; overhead electrical lines, and apparatus which is connected to them. A sectional committee was organized by the sponsors in 1921 and has been working for a number of years upon the formulation of definite standards which should be a guide in securing protection from this hazard. The needs of both Y VI PREFACE industry and the public have been kept in mind, and the standards now set up have been taken largely from Amer- ican practice and experience, although foreign practice has also been given consideration. The subject matter contemplated for this code comprises five parts, three of which are presented here. The other two parts, dealing with electrical apparatus and lines, are with- held for further consideration. In each part an introduc- tory statement to the particular subject in hand is given, and the code Is followed by an appendix in which is given a general discussion of lightning, its origin and characteris- tics, and the effects which it produces. An attempt is made in the appendix to indicate how much is definitely known about lightning and its properties and also theories of its origin and speculations regarding the magnitude of the electrical quantities involved in lightning phenomena. There is also appended a bibliography in which the more impor- tant contributions to the present state of the art are listed. The part of the code dealing with specifications for light- ning rods used to protect buildings goes into the questions of practical construction and sets forth in detail the require- ments of good design for such installations. These are of general application, and particular types of buildings may need more specific consideration. For the protection of per- sons and of oil tanks the standards are not so detailed but are aimed rather to state the general principles which should be applied. In spite of the value of lightning rods in the protection of buildings their use has at times and in places come into disrepute owing to a general lack of information as to the best methods of protection, and it is hoped that the publica- PREFACE VII tion of definite standards on this subject will enable the public to demand installations which will give them adequate protection. Lightning is considered responsible for a majority of tank fires of the petroleum industries. A realization of the im- portance of this source of loss to the industry and to the re- sources of the Nation has awakened a general interest in proper standards of protection. In this field, as in the pro- tection of ordinary buildings, many inadequate installations have been made in the past. By the application of the proper principles and standards of construction it is believed that this loss can be greatly reduced. Further experience and the accumulating knowledge of the properties of lightning may lead later to changes in these specifications, and future revisions are contemplated from time to time as experience and progress in the art may warrant. Comments regarding these specifications and recommended changes are invited by the committee from all who may have experience in applying them. CONTENTS Page Members of the sectional committee in Preface v Part I.—Protection of persons 1 Introduction 1 100. Purpose 2 101. Personal conduct 2 Part II.—Protection of buildings and miscellaneous property 3 Introduction 3 Relative losses from lightning 4 Factors to be considered 5 Fundamental principles of protection 10 Sec. 20. Scope, definitions, etc 14 200. Scope and purpose 14 201. Interpretations and exceptions 14 202. Mandatory and advisory requirements 15 203. Terms and definitions 15 Sec. 21. Lightning rods for ordinary buildings 16 210. Conductors 16 (a) Materials , 16 (b) Form and size 18 (c) Joints 19 (d) Fasteners 20 211. Points and elevation rods 21 (a) Attachment of points 21 (&) Elevation rods 21 (c) Braces for elevation rods 22 212. Prevention of deterioration 23 (0) General 23 (&) Corrosion 23 (c) Mechanical injury 23 (d) Use of ornaments 23 IX — X CONTEXTS Part IL—Protection of buildings and miscellaneous property Continued. Page 213. Location of air terminals 24 (a) General 24 (6) Projections 24 (c) Ridges, parapets, and edges of flat roofs— 24 (d) Metal projections and parts of buildings. 24 (e) Coursing of conductors 24 (f) Roof conductors 25 (g) Down conductors 25 (70 Obstructions 25 (i) Bends 25 214. Metal-roofed and metal-clad buildings 25 (a) Metal in overlapping sections 25 (&)
Recommended publications
  • Lightning on Transmission Line of the Harm and Prevention Measures
    Lightning on transmission lines hazards and Prevention Measures Wang Qinghao, Ge Changxin, Xue Zhicheng, Sun Fengwei, Wu Shaoyong, Li Zhixuan, Shi Dongpeng, Ren Hao, Li Jinye, Ma Hui, Cao Feiyi Fushun Power Supply Company, Liaoning Electric Power Company Limited, State Grid, China, [email protected] Keywords: power transmission line, lightning hazard, prevention measures Abstract. Through the analysis of lightning to the harmfulness of the power transmission line, puts forward the specific measures to prevent lightning accidents, improving insulation, installing controllable discharge lightning rod, reducing the tower grounding resistance, adding coupling ground wire and the proper use of send arrester electrical circuit transmission line. And take on the unit measures nearly were compared, statistics and analysis. Introduction Lightning accident is always an important factor affecting the reliability of the power supply of the electric line to send. Because of the randomness and complexity of lightning activity in the atmosphere, currently the world's research on knowledge transmission line lightning and many unknown elements. Lightning accident of overhead power transmission line is always a problem of safe power supply, lightning accidents accounted for almost all the accidents of 1/2 or more line. Therefore, how to effectively prevent lightning, lightning damage reduced to more and more by transmission line of the relevant personnel to pay attention[1-2]. At present, the measures of lightning protection of transmission line itself mainly rely on the erection of the overhead ground wire of the tower top, its operation and maintenance work is mainly on the detection and reconstruction of tower grounding resistance. Due to its single lightning protection measures, can not well meet the requirements of lightning protection.
    [Show full text]
  • Management of Radioactive Disused Lightning Rods
    2013 International Nuclear Atlantic Conference - INAC 2013 Recife, PE, Brazil, November 24-29, 2013 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-05-2 MANAGEMENT OF RADIOACTIVE DISUSED LIGHTNING RODS Paulo de Oliveira Santos, Fábio Silva Centro de Desenvolvimento da Energia Nuclear – CDTN/CNEN CP 941, Pampulha 30123-970 Belo Horizonte, MG [email protected], [email protected] ABSTRACT The manufacture of radioactive lightning rod was allowed from 1970 to 1989. This authorization was based on state-of-the art science of that time that verified that radioactive lightning rods had efficiency superior to the conventional lightning rods, denominated Franklin. However, the experience showed that their efficiency was not superior enough to justify the use of radioactive sources. Consequently, in 1989, the National Commission for Nuclear Energy - CNEN, issued the Resolution 04/89 from 04-19-1989, that forbidden the importation of 241Am tapes, assembling and commercialization of radioactive lightning-rods. The institutes of CNEN are responsible for receiving these lightning-rods and sending to the users procedures for removing and dispatch to the institutes. Therewith, these devices are kept away from the human being and environment. The Nuclear Technology Development Center - CDTN and Institute for Energy and Nuclear Research - IPEN of CNEN, has built laboratories appropriate for dismantling such devices and store the 241Am tapes safely. Nowadays are being researched methodologies to evaluate the contamination levels of the frame for
    [Show full text]
  • Efficacy of Lighting Rods
    The Ohio Naturalist, and Journal of Science PUBLISHED BY The Biological Club of the Ohio State University. Volume XV. FEBRUARY, 1915. No. 4. TABLE OF CONTENTS. SMITH—Efficacy of Lightning Rods 437 LINNELL—Wild and Cultivated Clovers of Ohio 443 Essentials of College Botany 448 WALTON—Cell Division and the Formation of Paramylou in Euglena oxyuris Schmarda 449 MCAVOY—Meeting of the Biological Club 452 The Ferns of Allegheny County, Pennsylvania 452 EFFICACY OF LIGHTNING RODS. J. WARREN SMITH. FIRE LOSSES. It is stated on good authority that in the United States fire costs over $500 a minute. The National Fire Prevention Associa- tion of New York states that fire losses and the cost of fire pro- tection amounts to $450,000,000 in the United States each year. This is $850 a minute. Fire Losses Due to Lightning.—The Wisconsin Fire Marshal says that lightning in this country destroys more property than matches, sparks, and kerosene together, and more than any other cause, except defective flues. Figures gathered from the reports of the State Fire Marshals in Iowa, Indiana, and Ohio, for 1913, indicate that the number of fires due to lightning was one-sixth of the number from all causes and the loss by lightning one-eleventh of the total fire loss. In the summer of 1914, the writer gathered statistics from 121 Mutual Fire Insurance Companies operating in 15 different States, largely in the central part of the country. These statistics show that in 1913 the total number of buildings burned from any cause was 1,174.
    [Show full text]
  • Numerical Analysis of Transient Performance of Grounding Grid with Lightning Rod Installed on Multi-Grounded Frame
    energies Article Numerical Analysis of Transient Performance of Grounding Grid with Lightning Rod Installed on Multi-Grounded Frame Zhuoran Liu 1, Weidong Shi 2 and Bo Zhang 1,* 1 State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China; [email protected] 2 High Voltage Department, China Electric Power Research Institute, Beijing 100192, China; [email protected] * Correspondence: [email protected] Abstract: In large substations, many lightning rods are installed on multi-grounded frames. The lightning rods, the frame, the grounding grid and the soil form a whole body, and the lightning current will be discharged from many grounding points. In this paper, based on the partial element equivalent circuit method, a numerical model, in the time domain, is developed to simulate the lightning-caused electromagnetic transients on the frame and the grounding grid. The model is verified by field testing and by comparison with commercial software. The model has several features: (1) it has a simple time domain form; (2) it is stable due to a staggered arrangement of space and time variables and an implicit difference scheme used, and (3) the dimension of the equations is relatively small because the unknown variables are divided into several groups, which are calculated one by one. With this method, the transient characteristics of the grounding grid with lightning rods on the frame are calculated, and the factors affecting the results are analyzed. It can be seen that although the frame causes the ground potential rise in an evenly distributed manner, compared with the situation in which the lightning strikes an independent lightning rod, the ground potential decrease Citation: Liu, Z.; Shi, W.; Zhang, B.
    [Show full text]
  • Physics 115 Lightning Gauss's Law Electrical Potential Energy Electric
    Physics 115 General Physics II Session 18 Lightning Gauss’s Law Electrical potential energy Electric potential V • R. J. Wilkes • Email: [email protected] • Home page: http://courses.washington.edu/phy115a/ 5/1/14 1 Lecture Schedule (up to exam 2) Today 5/1/14 Physics 115 2 Example: Electron Moving in a Perpendicular Electric Field ...similar to prob. 19-101 in textbook 6 • Electron has v0 = 1.00x10 m/s i • Enters uniform electric field E = 2000 N/C (down) (a) Compare the electric and gravitational forces on the electron. (b) By how much is the electron deflected after travelling 1.0 cm in the x direction? y x F eE e = 1 2 Δy = ayt , ay = Fnet / m = (eE ↑+mg ↓) / m ≈ eE / m Fg mg 2 −19 ! $2 (1.60×10 C)(2000 N/C) 1 ! eE $ 2 Δx eE Δx = −31 Δy = # &t , v >> v → t ≈ → Δy = # & (9.11×10 kg)(9.8 N/kg) x y 2" m % vx 2m" vx % 13 = 3.6×10 2 (1.60×10−19 C)(2000 N/C)! (0.01 m) $ = −31 # 6 & (Math typos corrected) 2(9.11×10 kg) "(1.0×10 m/s)% 5/1/14 Physics 115 = 0.018 m =1.8 cm (upward) 3 Big Static Charges: About Lightning • Lightning = huge electric discharge • Clouds get charged through friction – Clouds rub against mountains – Raindrops/ice particles carry charge • Discharge may carry 100,000 amperes – What’s an ampere ? Definition soon… • 1 kilometer long arc means 3 billion volts! – What’s a volt ? Definition soon… – High voltage breaks down air’s resistance – What’s resistance? Definition soon..
    [Show full text]
  • Protection of Life and Property Against Lightning
    DEPARTMENT OF COMMERCE Technologic Papers OF THE Bureau of Standards S. W. STRATTON, Director No. 56 PROTECTION OF LIFE AND PROPERTY AGAINST LIGHTNING BY 0. S. PETERS, Assistant Physicist Bureau of Standards [ISSUED DECEMBER 15, 1915] WASHINGTON GOVERNMENT PRINTING OFFICE 1915 ADDITIONAL COPIES OF THIS PUBLICATION MAY BE PROCURED FROM THE SUPERINTENDENT OF DOCUMENTS GOVERNMENT PRINTING OFFICE WASHINGTON, D. C. AT 35 CENTS PER COPY .. .. PROTECTION OF LIFE AND PROPERTY AGAINST LIGHTNING By O. S. Peters CONTENTS Page I. Introduction 4 1. Early history of the lightning rod 4 2. Present status of the practice of protection against lightning 7 3. Lack of attention by the public to protection against lightning. 8 4. The need for investigation and spreading information concerning protection against lightning 9 5. Object of this paper 10 II. Desirability of protection against lightning 11 1. Lightning as a cause of fire and damage to property 11 2. Lightning as a cause of injury and loss of life 16 III. Efficiency of lightning rods 24 1. Results of the use of lightning rods in the United States 25 2. Results of the use of lightning rods in Europe 28 IV. Some points of disagreement among various authorities 30 1. Notes on causes and supposed causes of damage to protected buildings 31 2. Iron conductors versus copper conductors 34 3 Systems of protection against lightning with points versus systems without points 35 4. Use of insulators between rods and buildings 36 V. Characteristics of lightning flashes 37 1. Current intensities of lightning flashes 38 2. Frequency and duration of lightning flashes 41 3.
    [Show full text]
  • Adoption of IEC 62305 As the Basis for One Major U.S. Electric Utility's Lightning Protection Standard
    Adoption of IEC 62305 as the Basis for One Major U.S. Electric Utility’s Lightning Protection Standard Gary T. Brandon Duke Energy Charlotte, NC USA [email protected] Abstract— Lightning protection systems designed for electric In 1882, the Royal Meteorological Society convened a power generation facilities in the United States, by default, are lightning rod conference to formulate the existing knowledge typically designed according to the specifications of NFPA 780, as of atmospheric electricity for the protection of property from this is the governing lightning protection standard in this damage by lightning, as well as, to prepare and issue a general country. These facilities use the design guidance of this standard code of rules for the erection of lightning conductors in an even though this standard explicitly states that electric effort to take action for the public. The Report of the Lightning generating facilities are excluded from its requirements. Rod Conference (Symons 1882) provided the code of rules for Justification for this exclusion is given in Annex A of NFPA 780 those who installed lightning protection systems in Britain. and states, "Most electric utilities have standards covering the Following the conference proceeding, the first British code for protection of their facilities and equipment." Therefore, electric the protection against lightning was developed. generating facilities have no guidance on how to implement lightning protection for their facilities. Duke Energy's Fossil Up until this time no guidance was available in the United Hydro Operations Division performed a one to one comparison States for the design and implementation of LPS.
    [Show full text]
  • The Performance of Lightning Rod Arrester and Its Effect on the Top Potential of Tower for 500 Kv Transmission System
    Journal of Power and Energy Engineering, 2014, 2, 19-23 Published Online November 2014 in SciRes. http://www.scirp.org/journal/jpee http://dx.doi.org/10.4236/jpee.2014.211003 The Performance of Lightning Rod Arrester and Its Effect on the Top Potential of Tower for 500 kV Transmission System Jian’gang Gong1, Zhouyou Lin2, Yangyong Xu1, Shen Zhao2, Qiang Zhang3 1State Grid Zhejiang Electric Power Company, Hangzhou, China 2Wenzhou Power Supply Company of State Grid Zhejiang Electric Power Company, Wenzhou, China 3Chengdu Xinghe Technology Industry Corporation, LTD, Chengdu, China Email: [email protected] Received 12 September 2014; revised 25 October 2014; accepted 14 November 2014 Copyright © 2014 by authors and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/ Abstract When the tower overhead is struck by the lightning impulse, the lightning current flows into the earth through the impedance of tower and the grounding resistance, which heightens potential of the tower overhead and possibly induces insulator flashover. Lighting rod arrester is used to shield the tower and provide another routine for lightning current, decreasing the potential of tower overhead. In this paper, the performance of a 500 kV lighting rod arrester is tested used in AC transmission system under the current impulse. Besides, the influence of the lightning rod ar- rester performance on the top potential of tower is also studied. The results show that, when the rod arrester is connected to the tower, the top potential of tower can be obviously limited under the lightning strike.
    [Show full text]
  • Effects of Lightning Rod on a Substation After a Lightning Stroke
    Proceedings of the World Congress on Engineering 2010 Vol III WCE 2010, June 30 - July 2, 2010, London, U.K. Effects of Lightning Rod on a Substation after a Lightning Stroke M. Derakhshanfar, Student Membrer, IEEE, M. Javdani E. carrying masts or shield wires. A typical design consists of a Abstract—This paper presents analysis effects of a lightning 4 rod system forming a 3 m × 3 m .The lightning stroke rod in a substation with different grounding systems. A injects a very high amount of current about 10 KA[5] in the lightning stroke is injected to a lightning rod, and then the rod that makes a strong electric field and potential induced voltage on the ground around the rod is calculated distribution around it. This electric field is dangerous for using simulation software. At the end the best grounding both the installations and people around it. So the current system that causes less induced voltage around the rod is should flow in the rod in such a way that induces the least suggested. electric field and potential both on the ground and in air. Index Terms—lightning stroke, Lightning rod, Substation, In this project a singular lightning rod in a substation is safety, Step Voltage. simulated and its behavior like potential distributions and step voltages in different conditions is investigated. I.INTRODUCTION If a current passed through the ground there would be a Substations are within the most important components of voltage difference on the ground. The voltage difference for the power system. They are subsidiary station of an one meter is called voltage step [6].
    [Show full text]
  • Lightning Protection for Historic Structures
    PRESERVATION 50 BRIEFS Lightning Protection for Historic Structures Charles E. Fisher National Park Service U.S. Department of the Interior Technical Preservation Services Introduction Old systems that have survived in whole or in part on historic structures may be historic features in their own The loss of historic buildings as a result of lightning right and deserve preservation. Such historic lightning strikes makes local front page news every year. protection systems may still be operating properly Lightning strikes make no distinction between historic or can be repaired and upgraded. Some old systems properties and other types of structures. Historic simply are too deteriorated, incomplete, or archaic to barns, churches, museums, homes, stores, factories, repair and make fully functional, raising the question lighthouses, schools, and other buildings, as well whether they should be saved in place or removed as structures such as tall monuments, may be at in whole or in part for safety. For historic structures unnecessary risk of damage or loss as a result of a strike that have none and are located in areas that are prone by lightning. to lightning strikes, or are of special significance and deemed irreplaceable, a modern lightning protection The insurance industry reports that 5% of all claims system may merit installation. are lightning-related in the U.S., with annual building damage estimated as high as $1 billion according This Preservation Brief is designed for owners, property to Underwriters Laboratories, Inc. Certain types managers, architects, contractors, and others involved of structures are especially susceptible to damage, in the preservation of historic structures.
    [Show full text]
  • Electric Conductors and Insulators
    Electric Conductors and Insulators Jean Brainard, Ph.D. Say Thanks to the Authors Click http://www.ck12.org/saythanks (No sign in required) AUTHOR Jean Brainard, Ph.D. To access a customizable version of this book, as well as other interactive content, visit www.ck12.org CK-12 Foundation is a non-profit organization with a mission to reduce the cost of textbook materials for the K-12 market both in the U.S. and worldwide. Using an open-source, collaborative, and web-based compilation model, CK-12 pioneers and promotes the creation and distribution of high-quality, adaptive online textbooks that can be mixed, modified and printed (i.e., the FlexBook® textbooks). Copyright © 2016 CK-12 Foundation, www.ck12.org The names “CK-12” and “CK12” and associated logos and the terms “FlexBook®” and “FlexBook Platform®” (collectively “CK-12 Marks”) are trademarks and service marks of CK-12 Foundation and are protected by federal, state, and international laws. Any form of reproduction of this book in any format or medium, in whole or in sections must include the referral attribution link http://www.ck12.org/saythanks (placed in a visible location) in addition to the following terms. Except as otherwise noted, all CK-12 Content (including CK-12 Curriculum Material) is made available to Users in accordance with the Creative Commons Attribution-Non-Commercial 3.0 Unported (CC BY-NC 3.0) License (http://creativecommons.org/ licenses/by-nc/3.0/), as amended and updated by Creative Com- mons from time to time (the “CC License”), which is incorporated herein by this reference.
    [Show full text]
  • Lightning & Surge Protection
    Lightning & Surge Protection Contents 1. What is Lightning? How to Protect Instruments? .... ............................. 2 1-1 Emergence of thundercloud ............................................................................................................. 2 1-2 What is lightning surge? ................................................................................................................... 2 1-3 Electrostatic induction ...................................................................................................................... 3 1-4 Electromagnetic induction ................................................................................................................ 3 1-5 Increased ground potential .............................................................................................................. 4 1-6 Entry pathway of lightning surge ...................................................................................................... 4 1-7 Breaking mode of electrical instrument ............................................................................................ 5 1-8 Fundamentals of surge absorbing ................................................................................................... 6 1-9 Surge protector selection ................................................................................................................. 7 1-10 Points of caution when installing surge protectors ......................................................................... 8 2. FAQ for Surge
    [Show full text]