Effect of Aortic Insufficiency on Arterial Blood Pressure, Coronary Blood Flow and Cardiac Oxygen Consumption

Total Page:16

File Type:pdf, Size:1020Kb

Effect of Aortic Insufficiency on Arterial Blood Pressure, Coronary Blood Flow and Cardiac Oxygen Consumption EFFECT OF AORTIC INSUFFICIENCY ON ARTERIAL BLOOD PRESSURE, CORONARY BLOOD FLOW AND CARDIAC OXYGEN CONSUMPTION René Wégria, … , Robert Jreissaty, Jiro Nakano J Clin Invest. 1958;37(3):471-475. https://doi.org/10.1172/JCI103627. Research Article Find the latest version: https://jci.me/103627/pdf EFFECT OF AORTIC INSUFFICIENCY ON ARTERIAL BLOOD PRESSURE, CORONARY BLOOD FLOW AND CARDIAC OXYGEN CONSUMPTION' By RENE WEGRIA, GERHARD MUELHEIMS,2 JAMES R. GOLUB,3 ROBERT JREISSATY, AND JIRO NAKANO 4 (From the Department of Medicine, Columbia University College of Physicians and Surgeons, and the Presbyterian Hospital, New York, N. Y.) (Submitted for publication September 19, 1957; accepted November 21, 1957) In patients with aortic insufficiency and with- 10 ml. per kilogram of weight of a 1 per cent chloralose out disease of the coronary ostia or arteries, the solution. In the first four dogs the trachea, both com- of chest pain having some or many of mon carotid arteries and both external jugular veins occurrence were exposed through a midline incision and a Y-shaped the characteristics of cardiac pain due to myo- glass tube inserted into the trachea. Under artificial cardial ischemia has been ascribed classically to respiration, the left hemithorax was opened, the peri- a decrease in the coronary blood flow (1, 2), the cardium incised and the heart suspended in a peri- aortic insufficiency presumably decreasing the cardial cradle. The method used to measure and con- the mean aortic tinuously record the output of the left ventricle was a coronary blood flow by lowering modification of that previously described in this labora- diastolic pressure. However, the data available tory (6). The proximal ends of the left subclavian ar- on the effect of aortic insufficiency on the coronary tery and brachiocephalic trunk were cannulated. Then blood flow are contradictory. From acute ex- the aorta was clamped distally to the subclavian artery periments on the anesthestized dog, Green (3), so that the blood ejected by the left ventricle was di- as well as Green and Gregg (4), concluded that rected into an electromagnetic rotameter (7) and re- turned to the circulation via both carotid arteries can- when the aortic insufficiency is marked enough to nulated distally as well as both femoral arteries can- lower the aortic diastolic pressure, the increase nulated proximally and distally. Since the coronary in coronary blood flow occurring during systole sinus drains blood essentially only from the left coronary does not compensate for the decrease in flow dur- artery (8, 9) and since, in a given animal, the coronary and the mean coronary flow decreases. sinus blood flow represents a constant portion of the ing diastole left coronary artery flow (8), measurement of the coro- On the other hand, Foltz, Wendel, and West (5), nary sinus blood flow was used as a means of studying from measurements made on anesthetized dogs the left coronary artery blood flow. For that purpose, a in which one or two aortic cusps had been torn cannula was introduced via the left external jugular vein three or more days previously, concluded that the into the coronary sinus and tied in place by a string coronary blood flow was increased over levels passed around the coronary sinus. All the blood emerg- ing from the coronary sinus through this cannula was usually observed in normal dogs while oxygen directed into a second rotameter by means of which consumption was greatly increased over normal the coronary sinus blood flow was measured and con- levels. Because of the discrepancy in the opinions tinuously recorded. The coronary sinus blood was about the effect of aortic insufficiency on the coro- returned to the dog through a cannula introduced via the nary blood flow, it was thought advisable to rein- right external jugular vein down to the junction of the vestigate this problem. right auricle and the superior vena cava. Mean arterial blood pressure was recorded from the root of the aorta METHODS with a dampened Gregg manometer. Left ventricular output, mean aortic blood pressure and coronary sinus Eight dogs weighing between 17 and 40 kilograms blood flow were continuously recorded on photographic were anesthetized by the intravenous administration of paper. The heart rate was obtained by direct timing, 1 This work was made possible by grants-in-aid from from the blood pressure tracing or from an electro- the New York Heart Association, the Sidney A. Legendre cardiographic tracing. In the other four dogs the Gift and the Charles A. Frueauff Gift. output of the left ventricle was not measured and the 2 Postdoctorate Fellow of the United States Public coronary sinus flow was measured as in the first four Health Service. dogs. The mean femoral arterial blood pressure was $Fellow of the Dazian Foundation for Medical Re- recorded with a dampened Gregg manometer and the search. aortic pressure curve was recorded from the root of the 4 Research Fellow of the Hudson County (N. J.) aorta with another optical manometer. The instrument Heart Association. used to produce acute aortic insufficiency was the um- 471 472 R. WEGRIA, G. MUELHEIMS, J. R. GOLUB, R. JREISSATY, AND J. NAKANO TABLE I Effect of aortic insufficiency on heart rate, arterial blood pressure, cardiac output, coronary blood flow, coronary blood arteriovenous oxygen difference and cardiac oxygen consumption Duration Heart Arterial blood pressure Coronary Oxygen Exp. and of insuffi- rate Cardiac Coronary A-V 02 consump- dog no. ciency beat Mean Syst. Diast. output flow difference tion sec. min. mm. Hg mi./min. m./min. Vol. % ml./min. Aortic C.*. 136 150 1,220 59 15.5 9.2 1. A.I.t 235 160 135 830 80 15.4 12.4 R.t 152 140 1,000 57 15.9 9.1 C. 160 130 1,100 94 12.7 11.8 2. A.I. 316 160 110 960 113 13.4 15.1 R. 160 128 1,060 87 12.5 10.9 C. 167 97 810 49 15.8 7.7 3. A.I. 340 167 76 600 55 15.6 8.6 R. 176 94 675 50 15.5 7.7 C. 166 119 940 65 12.2 7.9 4. A.I. 214 170 105 940 78 12.7 9.9 R. 170 120 1,050 74 12.8 9.5 Femoral C. 160 120 38 17.3 6.6 5. A.I. 304 162 98 45 17.4 7.8 R. 162 110 40 17.9 7.2 Femoral Aortic Cl§ 144 132 157 116 68 16.2 11.0 A A.I.II 208 150 125 150 98 76 16.1 12.0 R, 146 132 148 114 68 16.2 11.0 C21 148 128 154 115 67 6.6 A.I.2 80 148 122 144 88 79 B A.I.8 155 150 117 145 80 80 7 C 4 210 150 118 148 76 85 A.I.5 277 150 108 141 63 87 R2 150 128 156 115 67 C, 183 128 140 105 61 14.9 9.1 A A.I.1 244 182 105 140 48 70 16.4 11.5 R, 185 128 140 105 61 14.9 9.1 7. C2 186 122 140 105 57 A.I.2 85 188 104 142 52 72 B A.I.s 243 188 104 145 64 72 A.I.4 348 188 104 142 64 70 R2 188 122 140 112 61 C, 112 160 183 132 65 21.1 13.7 A A.I., 126 140 128 154 55 83 21.5 17.8 R, 112 160 178 134 74 21.3 15.8 C2 112 158 182 125 62 A 30 120 139 172 86 81 8. *A.Las.I.2 83 122 156 172 95 72 A.I.4 130 132 138 176 96 77 B A.I.6 204 138 139 185 70 86 A.I.6 251 138 130 164 42 89 A.I.7 288 140 126 165 38 91 R2 138 160 180 120 68 * C., control. t A.I., aortic insufficiency. T R., recovery. § C1, control for part A. D A.I.,. 2 s, etc., aortic insufficiency of severity increasing or decreasing stepwise. C2, control for part B. AORTIC INSUFFICIENCY AND CORONARY CIRCULATION 473 brella type valve spreader previously described by Wig- gers and Maltby (10). While blood pressure, coronary 80 r-AORTIC BLOOD PRESSURE sinus blood flow and in some experiments left ventricu- lar output were being continuously recorded, the valve 160 H spreader was slipped into the aortic ring through the left 1- ventricular wall. The introduction of the instrument 140 into the aortic ring was without effect on blood pres- 120 1- CP sure, left ventricular output and coronary sinus flow. x Proper positioning of the instrument was judged by E I H0F palpation and the correctness of the position of the in- strument was checked by direct visualization at the end of each experiment. 80P In all eight experiments, after a control period an 60 k aortic insufficiency severe enough to lower definitely the mean and/or diastolic arterial blood pressure was in- 40 > duced and maintained from 126 to 340 seconds, after 90 -CORONARY BLLOOD FLOW which a period of recovery was observed. Arterial and coronary sinus blood samples were drawn simultane- 80 -\ ously at the end of the control period, the period of c aortic insufficiency and during the recovery period. The 70 _ oxygen content of the arterial and venous bloods was It> determined in duplicate by the method of Van Slyke and Neill (11). The oxygen consumption of that portion of the myocardium drained by the coronary sinus was cal- A.L A.
Recommended publications
  • Blood Vessels: Part A
    Chapter 19 The Cardiovascular System: Blood Vessels: Part A Blood Vessels • Delivery system of dynamic structures that begins and ends at heart – Arteries: carry blood away from heart; oxygenated except for pulmonary circulation and umbilical vessels of fetus – Capillaries: contact tissue cells; directly serve cellular needs – Veins: carry blood toward heart Structure of Blood Vessel Walls • Lumen – Central blood-containing space • Three wall layers in arteries and veins – Tunica intima, tunica media, and tunica externa • Capillaries – Endothelium with sparse basal lamina Tunics • Tunica intima – Endothelium lines lumen of all vessels • Continuous with endocardium • Slick surface reduces friction – Subendothelial layer in vessels larger than 1 mm; connective tissue basement membrane Tunics • Tunica media – Smooth muscle and sheets of elastin – Sympathetic vasomotor nerve fibers control vasoconstriction and vasodilation of vessels • Influence blood flow and blood pressure Tunics • Tunica externa (tunica adventitia) – Collagen fibers protect and reinforce; anchor to surrounding structures – Contains nerve fibers, lymphatic vessels – Vasa vasorum of larger vessels nourishes external layer Blood Vessels • Vessels vary in length, diameter, wall thickness, tissue makeup • See figure 19.2 for interaction with lymphatic vessels Arterial System: Elastic Arteries • Large thick-walled arteries with elastin in all three tunics • Aorta and its major branches • Large lumen offers low resistance • Inactive in vasoconstriction • Act as pressure reservoirs—expand
    [Show full text]
  • Cardiovascular Magnetic Resonance Pocket Guide
    Series Editors Bernhard A. Herzog John P. Greenwood Sven Plein Cardiovascular Magnetic Resonance Congenital Heart Disease Pocket Guide Bernhard A. Herzog Ananth Kidambi George Ballard First Edition 2014 Congenital Pocket Guide Tetralogy / Foreword Pulmonary Atresia Standard Views TGA Difficult Scans Single Ventricle Sequential Ebstein Anomaly Segmental Analysis Coronary Artery Shunts Anomalies AV Disease / References Aortic Coarctation Terminology Series Editors Authors Bernhard A. Herzog Bernhard A. Herzog John P. Greenwood Ananth Kidambi Sven Plein George Ballard Foreword The role of cardiovascular magnetic resonance (CMR) in evaluating the adult population with congenital heart disease continues to expand. This pocket guide aims to provide a day-to-day companion for those new to congenital CMR and for those looking for a quick reference guide in routine practice. The booklet gives an overview of the most common abnormalities and interventions as well as post-operative complications. It also provides typical scan protocols, key issues and a guide for reporting for each topic. Bernhard A. Herzog Ananth Kidambi George Ballard The Cardiovascular Magnetic Resonance Pocket Guide represents the views of the ESC Working Group on Cardiovascular Magnetic Resonance and was arrived at after careful consideration of the available evidence at the time it was written. Health professionals are encouraged to take it fully into account when exercising their clinical judgment. This pocket guide does not, however, override the individual responsibility of health professionals to make appropriate decisions in the circumstances of the individual patients, in consultation with that patient and, where appropriate and necessary, the patient's guardian or carer. It is also the health professional's responsibility to verify the applicable rules and regulations applicable to drugs and devices at the time of prescription.
    [Show full text]
  • Valve Replacement Alexander Zezulkal, John Mackinnon2 and D.G
    Postgrad Med J: first published as 10.1136/pgmj.68.797.180 on 1 March 1992. Downloaded from Postgrad Med J (1992) 68, 180 - 185 i) The Fellowship of Postgraduate Medicine, 1992 Hypertension in aortic valve disease and its response to valve replacement Alexander Zezulkal, John Mackinnon2 and D.G. Beevers' 'University Department ofMedicine and 2Department ofCardiology, Dudley Road Hospital, Birmingham BT18 7QH, UK Summary: We have investigated the prevalence ofhypertension and the response ofblood pressure to operation in 87 patients with lone aortic valve disease who underwent aortic valve replacement. In patients with aortic stenosis alone 26% were hypertensive pre-operatively (age and sex adjusted blood pressure > 160 systolic and or > 95 mmHg diastolic) and 24% were hypertensive post-operatively. In those with aortic regurgitation alone, hypertension was present in 65% before and 57% after valve replacement using the same criterion. For combined stenosis and regurgitation, the prevalence was 54% and 62%, respectively. The post-operative increase in systolic pressure in patients with aortic stenosis occurred mainly in those with a history of left ventricular failure. In those with aortic regurgitation or combined stenosis with regurgitation, diastolic pressure rose after valve replacement resulting in a prevalence of diastolic hypertension of 44% and 35%, respectively. Blood pressure changes were not predicted by the type of valve inserted nor its size. Our data show that despite severe symptomatic aortic valve disease, systolic hypertension was common in aortic stenosis and diastolic hypertension was found in aortic regurgitation. This underlines the by copyright. importance of blood pressure monitoring in patients following aortic valve replacement.
    [Show full text]
  • Time-Varying Elastance and Left Ventricular Aortic Coupling Keith R
    Walley Critical Care (2016) 20:270 DOI 10.1186/s13054-016-1439-6 REVIEW Open Access Left ventricular function: time-varying elastance and left ventricular aortic coupling Keith R. Walley Abstract heart must have special characteristics that allow it to respond appropriately and deliver necessary blood flow Many aspects of left ventricular function are explained and oxygen, even though flow is regulated from outside by considering ventricular pressure–volume characteristics. the heart. Contractility is best measured by the slope, Emax, of the To understand these special cardiac characteristics we end-systolic pressure–volume relationship. Ventricular start with ventricular function curves and show how systole is usefully characterized by a time-varying these curves are generated by underlying ventricular elastance (ΔP/ΔV). An extended area, the pressure– pressure–volume characteristics. Understanding ventricu- volume area, subtended by the ventricular pressure– lar function from a pressure–volume perspective leads to volume loop (useful mechanical work) and the ESPVR consideration of concepts such as time-varying ventricular (energy expended without mechanical work), is linearly elastance and the connection between the work of the related to myocardial oxygen consumption per beat. heart during a cardiac cycle and myocardial oxygen con- For energetically efficient systolic ejection ventricular sumption. Connection of the heart to the arterial circula- elastance should be, and is, matched to aortic elastance. tion is then considered. Diastole and the connection of Without matching, the fraction of energy expended the heart to the venous circulation is considered in an ab- without mechanical work increases and energy is lost breviated form as these relationships, which define how during ejection across the aortic valve.
    [Show full text]
  • 04. the Cardiac Cycle/Wiggers Diagram
    Part I Anaesthesia Refresher Course – 2018 4 University of Cape Town The Cardiac Cycle The “Wiggers diagram” Prof. Justiaan Swanevelder Dept of Anaesthesia & Perioperative Medicine University of Cape Town Each cardiac cycle consists of a period of relaxation (diastole) followed by ventricular contraction (systole). During diastole the ventricles are relaxed to allow filling. In systole the right and left ventricles contract, ejecting blood into the pulmonary and systemic circulations respectively. Ventricles The left ventricle pumps blood into the systemic circulation via the aorta. The systemic vascular resistance (SVR) is 5–7 times greater than the pulmonary vascular resistance (PVR). This makes it a high-pressure system (compared with the pulmonary vascular system), which requires a greater mechanical power output from the left ventricle (LV). The free wall of the LV and the interventricular septum form the bulk of the muscle mass in the heart. A normal LV can develop intraventricular pressures up to 300 mmHg. Coronary perfusion to the LV occurs mainly in diastole, when the myocardium is relaxed. The right ventricle receives blood from the venae cavae and coronary circulation, and pumps it via the pulmonary vasculature into the LV. Since PVR is a fraction of SVR, pulmonary arterial pressures are relatively low and the wall thickness of the right ventricle (RV) is much less than that of the LV. The RV thus resembles a passive conduit rather than a pump. Coronary perfusion to the RV occurs continuously during systole and diastole because of the low intraventricular and intramural pressures. In spite of the anatomical differences, the mechanical behaviour of the RV and LV is very similar.
    [Show full text]
  • Norepinephrine Induced Pulmonary Congestion in Patients with Aortic Valve Regurgitation
    NOREPINEPHRINE INDUCED PULMONARY CONGESTION IN PATIENTS WITH AORTIC VALVE REGURGITATION Timothy J. Regan, … , Kenan Binak, Harper K. Hellems J Clin Invest. 1959;38(9):1564-1571. https://doi.org/10.1172/JCI103935. Research Article Find the latest version: https://jci.me/103935/pdf NOREPINEPHRINE INDUCED PULMONARY CONGESTION IN PATIENTS WITH AORTIC VALVE REGURGITATION * By TIMOTHY J. REGAN, VALENTINO DEFAZIO, KENAN BINAKt AND HARPER K. HELLEMS (From the Cardiovascular Research Laboratories, Departments of Medicine, Wayne State Uni- versity College of Medicine, and City of Detroit Receiving Hospital, Detroit, Mich.) (Submitted for publication March 3, 1959; accepted May 14, 1959) The regulation of venous blood flow into the METHODS heart and the effects of blood volume redistribution All subjects were studied in the fasting state approxi- upon cardiac function have not been amply defined. mately two hours after receiving 0.1 Gm. of pentobarbital While enhanced venomotor tone induced by nor- sodium. A double lumen catheter was used to measure epinephrine has been found to increase the volume pressures simultaneously from the pulmonary "capillary" and pulmonary artery. The "capillary" position was as- of a central reservoir in the dog (1), such a vol- sumed to be present when the catheter could not be ad- ume shift has not been demonstrated in man, ex- vanced farther in the lung bed, the tip did not move with cept inferentially by the finding of a decrease in the cardiac cycle and a compatible pressure pattern was the limb venous volume (2). obtained. A specimen of blood saturated with oxygen This type of alteration might be expected to af- was secured from the wedged catheter tip whenever this particularly was possible.
    [Show full text]
  • Chapter 9 Monitoring of the Heart and Vascular System
    Chapter 9 Monitoring of the Heart and Vascular System David L. Reich, MD • Alexander J. Mittnacht, MD • Martin J. London, MD • Joel A. Kaplan, MD Hemodynamic Monitoring Cardiac Output Monitoring Arterial Pressure Monitoring Indicator Dilution Arterial Cannulation Sites Analysis and Interpretation Indications of Hemodynamic Data Insertion Techniques Systemic and Pulmonary Vascular Resistances Central Venous Pressure Monitoring Frank-Starling Relationships Indications Monitoring Coronary Perfusion Complications Electrocardiography Pulmonary Arterial Pressure Monitoring Lead Systems Placement of the Pulmonary Artery Catheter Detection of Myocardial Ischemia Indications Intraoperative Lead Systems Complications Arrhythmia and Pacemaker Detection Pacing Catheters Mixed Venous Oxygen Saturation Catheters Summary References HEMODYNAMIC MONITORING For patients with severe cardiovascular disease and those undergoing surgery associ- ated with rapid hemodynamic changes, adequate hemodynamic monitoring should be available at all times. With the ability to measure and record almost all vital physi- ologic parameters, the development of acute hemodynamic changes may be observed and corrective action may be taken in an attempt to correct adverse hemodynamics and improve outcome. Although outcome changes are difficult to prove, it is a rea- sonable assumption that appropriate hemodynamic monitoring should reduce the incidence of major cardiovascular complications. This is based on the presumption that the data obtained from these monitors are interpreted correctly and that thera- peutic decisions are implemented in a timely fashion. Many devices are available to monitor the cardiovascular system. These devices range from those that are completely noninvasive, such as the blood pressure (BP) cuff and ECG, to those that are extremely invasive, such as the pulmonary artery (PA) catheter. To make the best use of invasive monitors, the potential benefits to be gained from the information must outweigh the potential complications.
    [Show full text]
  • (BP1–BP2) Deletion in the UK Biobank
    European Journal of Human Genetics (2020) 28:1265–1273 https://doi.org/10.1038/s41431-020-0626-8 ARTICLE Association of congenital cardiovascular malformation and neuropsychiatric phenotypes with 15q11.2 (BP1–BP2) deletion in the UK Biobank 1 1 2 1 1 1 Simon G. Williams ● Apostol Nakev ● Hui Guo ● Simon Frain ● Gennadiy Tenin ● Anna Liakhovitskaia ● 3 3 4 1 Priyanka Saha ● James R. Priest ● Kathryn E. Hentges ● Bernard D. Keavney Received: 3 September 2019 / Revised: 12 February 2020 / Accepted: 24 March 2020 / Published online: 23 April 2020 © The Author(s) 2020. This article is published with open access Abstract Deletion of a non-imprinted 500kb genomic region at chromosome 15q11.2, between breakpoints 1 and 2 of the Prader–Willi/ Angelman locus (BP1–BP2 deletion), has been associated in previous studies with phenotypes including congenital cardiovascular malformations (CVM). Previous studies investigating association between BP1–BP2 deletion and CVM have tended to recruit cases with rarer and more severe CVM phenotypes; the impact of CVM on relatively unselected population cohorts, anticipated to contain chiefly less severe but commoner CHD phenotypes, is relatively unexplored. More precisely 1234567890();,: 1234567890();,: defining the impact of BP1–BP2 deletion on CVM risk could be useful to guide genetic counselling, since the deletion is frequently identified in the neurodevelopmental clinic. Using the UK Biobank (UKB) cohort of ~500,000 individuals, we identified individuals with CVM and investigated the association with deletions at the BP1–BP2 locus. In addition, we assessed the association of BP1–BP2 deletions with neuropsychiatric diagnoses, cognitive function and academic achievement. Cases of CVM had an increased prevalence of the deletion compared with controls (0.64%; OR = 1.73 [95% CI 1.08–2.75]; p = 0.03), as did those with neuropsychiatric diagnoses (0.68%; OR = 1.84 [95% CI 1.23–2.75]; p = 0.004).
    [Show full text]
  • Estimation of Central Systolic Blood Pressure Using an Oscillometric Blood Pressure Monitor
    Hypertension Research (2010) 33, 592–599 & 2010 The Japanese Society of Hypertension All rights reserved 0916-9636/10 $32.00 www.nature.com/hr ORIGINAL ARTICLE Estimation of central systolic blood pressure using an oscillometric blood pressure monitor Hao-Min Cheng1,2, Kang-Ling Wang2,3, Ying-Hwa Chen2,3, Shing-Jong Lin1,4, Lung-Ching Chen2,3, Shih-Hsien Sung2,3, Philip Yu-An Ding2,3, Wen-Chung Yu2,3, Jaw-Wen Chen1,4 and Chen-Huan Chen1,2,4 Current noninvasive techniques for assessing central aortic pressure require the recording of an arterial pressure wave using a high-fidelity applanation tonometer. We therefore developed and validated a novel method to estimate the central aortic systolic pressure using an oscillometric blood pressure monitor alone. Invasive high-fidelity right brachial and central aortic pressure waves, and left-brachial pulse volume plethysmography from an oscillometric blood pressure monitor, were obtained at baseline and 3 min after administration of sublingual nitroglycerin in 100 patients during cardiac catheterization. In the initial 50 patients (Generation Group), Central systolic blood pressure was predicted by a multi-variate prediction model generated from the comprehensive analysis of the invasive brachial pressure wave, including brachial late-systolic shoulder pressure value and parameters related to wave reflection and arterial compliance. Another prediction model was similarly constructed from the noninvasively calibrated pulse volume plethysmography. Both models were validated in the subsequent 50 patients (Validation Group) with results: r¼0.98 (Po0.001) and mean difference¼0.5±4.5 (95% confidence interval À8.3 to 9.3) mm Hg for the invasive model, and r¼0.93 (Po0.001) and mean difference¼À0.1±7.6 (95% confidence interval À15.0 to 14.8) mm Hg for the noninvasive model.
    [Show full text]
  • Monitoring of the Central Blood Pressure Waveform Via a Conformal Ultrasonic Device
    HHS Public Access Author manuscript Author ManuscriptAuthor Manuscript Author Nat Biomed Manuscript Author Eng. Author Manuscript Author manuscript; available in PMC 2019 March 21. Published in final edited form as: Nat Biomed Eng. 2018 September ; 2(9): 687–695. doi:10.1038/s41551-018-0287-x. Monitoring of the central blood pressure waveform via a conformal ultrasonic device Chonghe Wang#1, Xiaoshi Li#2, Hongjie Hu#2, Lin Zhang1, Zhenlong Huang1, Muyang Lin7, Zhuorui Zhang1, Zhenan Yin3, Brady Huang5, Hua Gong1, Shubha Bhaskaran3, Yue Gu2, Mitsutoshi Makihata6, Yuxuan Guo1, Yusheng Lei1, Yimu Chen1, Chunfeng Wang8, Yang Li1, Tianjiao Zhang1, Zeyu Chen4, Albert Pisano6, Liangfang Zhang1, Qifa Zhou4, and Sheng Xu1,2,3,9,* 1Department of Nanoengineering, University of California San Diego, La Jolla, CA, 92093-0448, USA. 2Materials Science and Engineering Program, University of California San Diego, La Jolla, CA, 92093-0418, USA. 3Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, 92093-0407, USA. 4Department of Ophthalmology and Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA 90089-1111, USA. 5Department of Radiology, School of Medicine, University of California San Diego, La Jolla, CA, 92103, USA. 6Department of Mechanical and Aerospace Engineering, University of California San Diego, La Jolla, CA, 92093-0411, USA. 7School of Precision Instrument and Optoelectronic Engineering, Tianjin University, Tianjin, 300072, China. 8The Key Laboratory of Materials Processing and Mold of Ministry of Education, School of Materials Science and Engineering, School of Physics & Engineering, Zhengzhou University, Zhengzhou, 450001, Henan, China. 9Department of Bioengineering, University of California San Diego, La Jolla, CA, 92093-0412, USA.
    [Show full text]
  • Effects of Inhibition of Nitric Oxide Formation on Basal Vasomotion and Endothelium-Dependent Responses of the Coronary Arteries in Awake Dogs
    Effects of inhibition of nitric oxide formation on basal vasomotion and endothelium-dependent responses of the coronary arteries in awake dogs. A Chu, … , S Moncada, F R Cobb J Clin Invest. 1991;87(6):1964-1968. https://doi.org/10.1172/JCI115223. Research Article The role of nitric oxide in basal vasomotor tone and stimulated endothelium-dependent dilations in the coronary arteries in chronically instrumented awake dogs was studied by examining the consequences of inhibiting endogenous nitric oxide formation with the specific inhibitor of nitric oxide formation, NG-monomethyl-L-arginine (L-NMMA). In four awake dogs, coronary dimension crystals were chronically implanted on the circumflex artery for the measurement of epicardial coronary diameter, and Doppler flow probes were implanted for quantitation of phasic coronary blood flow (vasomotion of distal regulatory resistance vessels). Basal epicardial coronary diameter, acetylcholine-stimulated endothelium-dependent dilation, and flow-induced endothelium-dependent dilation of the epicardial arteries and phasic blood flow were recorded before, and after 5, 15, 50, and 120 mg/kg of L-NMMA. L-NMMA induced a dose-related increase in basal epicardial coronary vasomotor tone. There was an accompanying increase in aortic pressure and a decrease in heart rate. At doses greater than or equal to 50 mg/kg, rest phasic coronary blood flow was also decreased. Left ventricular end-diastolic pressure and contractility were not significantly changed. In contrast, the flow-induced or acetylcholine-stimulated endothelium-dependent responses were attenuated only after infusion of the highest does of L-NMMA (120 mg/kg). The changes in the basal vasomotor tone and acetylcholine-stimulated endothelium-dependent responses returned towards the control states in the presence of L-arginine (660 mg/kg).
    [Show full text]
  • Phasic Coronary Blood Flow Patterns As Related to the Balance Between Oxygen Demand and Supply in the Myocardium
    Phasic Coronary Blood Flow Patterns as Related to the Balance between oxygen Demand and Supply in the Myocardium Fujio SHINTANI,M.D., Tan WATANABE,M.D., and Kazuzo KATO, M.D. SUMMARY To explore possible relationship between changing coronary arterial flow patterns and states of coronary circulation, the left circumflex arterial flow (mean and phasic) was measured simultaneously with the oxygensaturation of the great cardiac vein blood (SGCVO2,) in anesthetized open-chest dogs. Coronary vasomotion was altered either with admin- istration of drugs or with mechanical interventions. The "intermittent" flow pattern observed in the resting state persisted as far as SGCVO2re- mained unchanged or lowered regardless of changes in coronary flow, aortic pressure or heart rate. On the other hand, when increase in cir- cumflexflow occurred simultaneouslywith elevation of SGCVO2,a "con- tinuous" flow pattern of the circumflex flow was noticed. We suggest that (1) the "intermittent" flow pattern would indicate that efficient O2 uptake from the supplied arterial blood is taking place in the myocardium and (2) the "continuous" flow pattern would indicate presence of arterial flow excessto the myocardialrequirement, rendering the increased coronary blood flow less effectivefor its amount in terms of O2 supply to the myocardium. Additional Indexing Words: Oxygen saturation of the coronary vein blood Intermittent vs. con- tinuous flow pattern Coronary flow pathways BLOOD flow through the coronary circulation is modified principally by 1) changes in aortic
    [Show full text]