clarity and/or viscosity. This method can also be utilized Particulate Matter and in the event a product does not meet the USP criteria Size Testing for the Obscuration Method. Volume requirements: A minimum of 25 mL sample Eurofins BioPharma Product Testing is well-versed solution is required to meet the harmonized USP/EP/ in testing particulate matter ranging from <0.001 µm JP requirements. If the fill volume is >25 mL then only to >3,000 µm and uses a variety of techniques to 1 container is needed for testing. However, if the fill develop and validate methods. Our volume is <25 mL, than a minimum of 10 containers scientists are experienced in using orthogonal are required. Dilutions of samples can be performed as techniques to address a wide range of product and required. formulation issues—from protein aggregation through Particle sizes: The compendial requirement is to detect extraneous matter contamination. at >10 µm and >25 µm. Particles <10 µm cannot be accurately detected using the Microscopic Method. Why Choose Eurofins BioPharma Product Testing? Instrumentation: Olympus BMAX BX60 microscope, •  Direct interaction with our technical staff will equipped with an internal episcopic brightfield ensure a testing strategy appropriate for your illuminator, a circular diameter graticule and an external product formulation. focusable auxiliary illuminator. •  Our more than 30-year history of cGMP regulatory Micro Flow Imaging System (MFI) compliance ensures delivery of the highest quality data. Flow cell and digital photography are used to •  We offer a broad set of orthogonal methods individually image, size, and count particles in covering the entire particle size range. formulations. Using an autosampler or by manual Particulate Matter Testing injection, the sample is passed through the flow cell and Light Obscuration Test pictures are captured after automatic illumination and Based on the principle of light obscuration, this test precision focusing. MVSS software is used to process allows for automatic determination of the size and the captured images and determine the particle size number of particles according to their size. The test and count within a desired particle size range. MVAS is performed in a biological safety cabinet, under software is also used to identify the sample particle’s conditions that limit foreign particulate matter. morphology and shape attributes that traditional light Volume requirements: obscuration (LO) and size exclusion chromatography USP <788>/EP 2.9.19/JP 6.07: A minimum of 25 mL (SEC) technologies are not able to detect. sample solution is required to meet the harmonized Volume requirements: USP/EP/JP requirements. If the fill volume is >25 mL 1.0 – 2.0 mL per sample (5200 Model) then only 1 container is needed for testing. However, 1.0 – 6.0 mL per sample (5100 Model) if the fill volume is <25 mL, than a minimum of 10 Particle Sizes: containers are required. Dilutions of samples can be 1 µm – 70 µm (5200 with 100 µm flow cell) performed as required. 2 µm – 300 µm (5100 with 400 µm flow cell) USP <787>: Can be used as an alternative to USP <788> Instrumentation: Protein Simple MFI 5100 Micro and specifically addresses testing of therapeutic protein Flow Imaging System (comprised of MFI 5100 Flow injections and related preparations. Smaller test volumes Microscope, MFI View System Software (MVSS) and are allowed, and there is no specific volume requirement MFI View Analysis Suite (MVAS) Software). as compared to USP <788>. Specific sample handling Particle Size Testing instructions take into account potential issues associated Dynamic Light Scattering with analysis of these types of materials. Particle size distribution of sub-micron particles is Particle sizes: The compendial requirement is to enumerate measured at a 90 degree scattering angle using Dynamic particles at ≥10 µm and ≥25 µm, although particles in the Light Scattering. range of ≥2 µm - 400 µm can also be enumerated. Volume requirements: 0.1 g – 0.5 g per sample Instrumentation: HIAC 9703+ Liquid Particle Counting determination. System. Particle sizes: 0.0003 µm – 5 µm. Microscopic Particle Count Test Instrumentation: Malvern Zetasizer Nano ZS90. Utilized when certain test articles cannot be analyzed by the Light Obscuration method due to color, reduced BioPharma Product Testing

Quasi Elastic Light Scattering (QELS) Particle sizes: 3.8 µm – 100 µm. This test measures and uses molecular motion to Instrumentation: Malvern Zetasizer Nano ZS90. determine the diffusion coefficient of a molecule in Analytical Sieving solution. The diffusion coefficient for a spherical particle Sieving is usually the method of choice for classification is directly related to its “hydrodynamic radius.” of the coarser grades of single powders or granules. It Volume requirements: Approximately 100 µg (i.e., 100 µL is a particularly attractive method in that powders and injection of 1 mg/mL solution for in-line SEC operation). granules are classified only on the basis of particle size, Particle Sizes: Approximately 0.0005 µm – 0.03 µm. and in most cases, the analysis can be carried out in the Instrumentation: WyattQELS, which is embedded within dry state. Mechanical sieving is most suitable where the Wyatt HELEOS II. majority of the particles are larger than about 75 µm. For Multi-Angle Light Scattering (MALS) smaller particles, other means of agitation such as air-jet A static light scattering technique can be used in sieving may be more appropriate. conjunction with Size Exclusion Chromatography (SEC) Volume requirements: 10 g – 100 g is generally as an in-line detection technique, or it can be used for required per test. However, if the information needed to non-fractionated samples in the batch mode of operation. perform sieve testing for a specific material (i.e. sample Volume requirements: Approximately 100 µg (i.e., amount, sieve sizes and sieve time) cannot be provided, 100 µL injection of 1 mg/mL solution for in-line SEC then approximately 500 g will be required in order to operation) and 1,000 µg (direct 1000 µL infusion of 1 perform feasibility/endpoint determination to establish mg/mL solution for batch mode operation). the appropriate parameters prior to testing the material. Particle Sizes: 0.01 µm – 0.5 µm. Particle sizes: Certified ISO 3310-1, ASTM E-11 sieves Instrumentation: Wyatt Technologies HELEOS II. in sizes ranging from 25 µm to 2,000 µm. Larger sizes up to 11.20 mm may be purchased upon request. Laser Light Diffraction Instrumentation: Endecotts Octagon 200 Test Sieve Particle size distribution is measured by the dispersion Shaker, W.S. Tyler Model RX-29 Ro-Tap Shaker and and absorption of light (red and blue) generated by a Hosokawa Micron AirJet Sieve (Version II). laser using either the wet or dry dispersion techniques. Volume requirements: 0.1 g – 0.5 g per sample determination for wet dispersion. 0.5 g – 5 g per sample determination for dry dispersion. Particle sizes: 0.01 µm – 600 µm for wet dispersion and 0.02 µm – 3,500 µm for Scanning Electronic Microscopy (SEM) dry dispersion. Dynamic Light Scattering Instrumentation: Malvern Mastersizer Quasi Elastic Light Scattering (QELS) 3000 with Hydro MV wet dispersion unit Multi-Angle Light Scattering (MALS)

and the Aero S dry dispersion unit. Laser Light Diffraction - Dry Dispersion Zeta Potential (Electrophoretic Light Laser Light Diffraction - Wet Dispersion Scattering) Micro Flow Imaging System (MFI) Zeta potential is a measurement of Zeta Potential (Electrophoretic Light Scattering) the electrokinetic potential in colloidal Light Obscuration Test

dispersions. The Zeta Potential is Microscopic Particle Count Test measured at a 90 degree scattering angle Analytical Sieving using Electrophoretic Light Scattering.

Volume requirements: 0.1 g – 0.5 g per .0001 .01.001 .1 1 50 100 1,000 2,000 sample determination. Particle size in µm

Comprehensive GMP Testing Services Flexible Service Models Global Facilities

Method Development & Validation • Release Testing • Raw Materials Testing Fee For Service (FFS) Australia Denmark Ireland New Zealand Switzerland

Cell Banking Services • Virology Services • Facility & Process Validation Full-Time-Equivalent (FTE) Austria France Italy Spain UK Chemistry • Biochemistry • Molecular & Cell Biology • Microbiology Belgium Germany Japan Slovakia US Professional Scientific Stability Testing & Storage • Primary & Secondary Package Testing Services® (PSS) Canada India Netherlands Sweden

9132_EU 0621 www.eurofins.com/BPT