Minimizing Galvanic Corrosion Tech Data

Minimizing Galvanic Corrosion Tech Data

Tech Data Minimizing Galvanic Corrosion This document is subject to updates. For Electrical separation or transition fittings are not the most current Viega technical literature necessary between copper and most copper alloys please visit www.viega.us. like brass and bronze. Similar grades of stainless steel connected together, e.g., 304 and 316, do not require electrical separation. Dry systems installed indoors do not typically require electrical separation between dissimilar Viega products are designed to be installed by metals because there is no electrolyte present, but can licensed and trained plumbing and mechanical experience moderate galvanic corrosion in humid or professionals who are familiar with Viega corrosive environments. products and their installation. Installation by non-professionals may void Viega LLC’s warranty. When connecting copper to carbon steel or galvanized steel, flanges or dielectric unions should be used to electrically insulate each material. When connecting Galvanic corrosion (or bimetallic corrosion) is the process copper to stainless steel, a brass or bronze fitting between where dissimilar metals in direct contact with one another the two metals provides sufficient electrical separation in and an electrolyte corrode or oxidize. The metals corrode most environments. by creating an electrochemical path which allows metal ions to move from one metal (anode) to the other metal The relative size of dissimilar metals also affects galvanic (cathode). The rate and severity of corrosion depends on corrosion. A small, more noble (cathode) component in a the strength of the electrolyte, the difference in electrical system is usually acceptable. For example, stainless steel potential (or position in annodic index) between the metals or brass valves are often used in carbon steel pipelines and the relative size of anode compared to the cathode. with no adverse affects. Material selection and material transitions are the responsibility of the design engineer. The following are general guidelines for reference only. TD-PP 1119 Minimizing Galvanic Corrosion 1 of 2 Viega Minimizing Galvanic Corrosion Tech Data Pipe Material Flanges Dielectric Unions Threaded Adapters Carbon steel Not to copper Recommended Stainless steel to copper Carbon steel to stainless steel Application Specific Viega LLC 585 Interlocken Blvd. Broomfield, CO 80021 Phone (800) 976-9819 www.viega.us TD-PP 1119 Minimizing Galvanic Corrosion 2 of 2.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us