ENVIRONMENTAL IMPACT ASSESSMENT (EIA) October 2019 Proposed Development of Sustainable Scheduled Waste Treatment Center (SSWTC) at PT1682 Bukit Tagar Sanitary Landfill, Mukim Sungai Tinggi, Daerah Hulu Selangor, Selangor Darul Ehsan for Berjaya Alam Murni Sdn. Bhd. CHAPTER 5 PROJECT DESCRIPTION 5.0 Introduction This chapter presents the project description of the Development of Sustainable Scheduled Waste Treatment Center (SSWTC) at PT1682 Bukit Tagar Sanitary Landfill, Mukim Sungai Tinggi, District of Hulu Selangor, Selangor Darul Ehsan proposed by Berjaya Alam Murni Sdn. Bhd. (BAM), as the Project Proponent. BAM is proposing to build an integrated scheduled waste treatment and disposal facility to be located within Bukit Tagar Sanitary Landfill (BTSL). BTSL is developed by KUB-Berjaya Enviro Sdn. Bhd., a subsidiary of Berjaya Corporation Berhad, a conglomerate listed on the Kuala Lumpur Stock Exchange. BTSL is premised on a long-term concession from the Government of Malaysia. The proposed site is located within BTSL which is strategically located in the central region of Peninsular Malaysia and easily accessible with good road network. The treatment center will consist of WTE thermal treatment plant and secure landfill as well as other support facilities (i.e. storage facility, solidification facility, oil recovery facility, leachate treatment plant, surface water treatment plant etc.) and associated amenities with the Proposed Project implementation. The technical information presented in this chapter are provided by the Project Proponent and the potential technology provider involved in the project. 5.1 Project Location The proposed SSWTC site will be built in the West of Peninsular Malaysia (i.e. State of Selangor), in the Hulu Selangor district. The project will be developed within the existing BTSL boundary. The site of the planned facility is located at PTD1682, Jalan Bukit Tagar, 45500 Bukit Tagar, Selangor with GPS coordinates of latitude of 3°29'54.87"N and longitude of 101°28'41.01"E and easily accessible through the North-South Expressway’s Bukit Tagar interchange. The location of the proposed SSWTC project is shown in Figure 5.1 with the following address: Berjaya Alam Murni Sdn. Bhd. (BAM) PTD1682, Jalan Bukit Tagar, Daerah Hulu Selangor, 45500 Bukit Tagar, Selangor Darul Ehsan. Report No: AMR.2019.BAM.EIA Revision: 00 Chapter 5 - Project Description 5-1 ENVIRONMENTAL IMPACT ASSESSMENT (EIA) October 2019 Proposed Development of Sustainable Scheduled Waste Treatment Center (SSWTC) at PT1682 Bukit Tagar Sanitary Landfill, Mukim Sungai Tinggi, Daerah Hulu Selangor, Selangor Darul Ehsan for Berjaya Alam Murni Sdn. Bhd. Sabak Bernam Hulu Selangor Proposed Kuala SSWTC Selangor Site Gombak 3°29'54.87"N 101°28'41.01"E Petaling Klang Hulu Langat Kuala Langat Sepang Selangor Map Figure 5.1: Location of the Proposed SSWTC Site The Proposed SSWTC will occupy 40 acres land within BTSL which occupies a landfill footprint of 700 acres with another 1,000 acres of buffer zone surrounding it. This means that the existing BTSL is adequately surrounded with 500 m distance of buffer zone along its boundary. The buffer zone has long been preserved ever since BTSL was established and currently it is forested and cultivated with palm oil plantation. There are several facilities currently in operation within the BTSL premise such as Leachate Treatment Plant (LTP) for Sanitary Landfill, AMITA Kub-Berjaya Kitar (AKBK) and Renewable Energy Centre. Figure 5.2 showed the location of the proposed SSWTC and the existing facilities available within the BTSL boundary. The state-of-the art sanitary landfill Leachate Treatment Plant (LTP) and a 10 MW Landfill Gas to Energy (LFGtE) plant are located to the west of the SSWTC project site. The LTP is equipped with advanced Supervisory Control and Data Acquisition (SCADA) System for continuous 24 hours active monitoring of the facility. Similarly, sustainable resource center of scheduled waste recycling facility, Amita KUB-Berjaya Kitar (AKBK) is located to the southwest side of the project site. AKBK recycled a total of fifteen (15) codes of scheduled wastes under the Environmental Quality (Scheduled Wastes) Regulation 2005. Report No: AMR.2019.BAM.EIA Revision: 00 Chapter 5 - Project Description 5-2 ENVIRONMENTAL IMPACT ASSESSMENT (EIA) October 2019 Proposed Development of Sustainable Scheduled Waste Treatment Center (SSWTC) at PT1682 Bukit Tagar Sanitary Landfill, Mukim Sungai Tinggi, Daerah Hulu Selangor, Selangor Darul Ehsan for Berjaya Alam Murni Sdn. Bhd. 1 From Bukit SSWTC Site From Jalan 2 Tagar Toll Exit Bukit Tagar Advance Cell 2 5 for Advance Cell Solar Sanitary LFGtE Buffer Landfill 1 40 acres Zone 3 3 AKBK 4 4 Phase 3 5 LTP for Legend: Sanitary LTP – Leachate Treatment Plant Landfill SSWTC – Sustainable Scheduled Waste Treatment Center AKBK – AMITA Kub-Berjaya Kitar (LFGtE) – Landfill Gas to Energy Figure 5.2: Location of SSWTC Site and the Existing Facilities/Services Within BTSL Boundary Report No: AMR.2019.BAM.EIA Revision: 00 Chapter 5 - Project Description 5-3 ENVIRONMENTAL IMPACT ASSESSMENT (EIA) October 2019 Proposed Development of Sustainable Scheduled Waste Treatment Center (SSWTC) at PT1682 Bukit Tagar Sanitary Landfill, Mukim Sungai Tinggi, Daerah Hulu Selangor, Selangor Darul Ehsan for Berjaya Alam Murni Sdn. Bhd. 5.2 SSWTC Main Treatment and Disposal Facilities SSWTC is propose to manages an integrated scheduled waste facility catering waste generated from all over the country particularly focusing in the central, northern and eastern region. The development of SSWTC is proposed by BAM in response to the shortage of scheduled waste treatment and disposal facilities in Peninsular Malaysia. The main intention of BAM is to construct and operate the proposed SSWTC which consist of the following main facilities that fall under the prescribed activity listed in the Environmental Quality (Environmental Impact Assessment) (Prescribed Activities) Order 2015: WTE THERMAL TREATMENT PLANT (Capacity: 20,000 tons/year or 70 MT/day) SECURE LANDFILL (Capacity: 350,000 m3 of airspace) 5.2.1 Associated Facilities In addition to the main thermal treatment and secure landfill, other five (5) associated scheduled waste management facilities will be considered in the SSWTC. These include: - Storage Facility (Capacity: 10,000 tons) Solidification Facility (Capacity: 8,000 tons/year) Oil Recovery Facility (Capacity: 4,000 tons/year) Leachate Treatment Plant (LTP) (Capacity: 150 m3/day) Surface Water Treatment Plant (SWTP) (Capacity: 250 m3/day) Report No: AMR.2019.BAM.EIA Revision: 00 Chapter 5 - Project Description 5-4 ENVIRONMENTAL IMPACT ASSESSMENT (EIA) October 2019 Proposed Development of Sustainable Scheduled Waste Treatment Center (SSWTC) at PT1682 Bukit Tagar Sanitary Landfill, Mukim Sungai Tinggi, Daerah Hulu Selangor, Selangor Darul Ehsan for Berjaya Alam Murni Sdn. Bhd. 5.2.2 Other Supporting Infrastructures Other supporting infrastructures will be built at SSWTC site in order to support the main operation are as follow; 1. Site preparation and earth works; 2. Gate and guard house at the main entrance to the property; 3. Logistic and security office, security fencing around the whole of the property and additional security fencing around areas/facilities with restricted access; 4. Internal access roads, including traffic routing and control facilities as well as visitor parking, fleet parking, landing area; 5. Weighbridge for incoming and outgoing trucks; 6. Administration building; 7. Service building: • Changing room and restroom; • Canteen; and • Truck or vehicle washing and sampling. 8. Laboratory for waste analysis and characterization, environmental monitoring; 9. Engineering workshop and spare part storage; 10. Waste receiving area and storage facility including cold room for clinical waste storage; 11. Centralized control room; 12. Tank farm and pre-treatment area; 13. Leachate pond, treated water tank and surface water tank; 14. Fire water tank, fire control and fire-fighting system and pump house; 15. Dryer building; 16. Utilities; • Re-fueling station; • TNB sub-station; • Water supply and storage; • Surface water and drainage system; and • Telecommunication facilities. Figure 5.3 shows the overall layout of SSWTC facility which covers the area of 40 acres within the BTSL site boundary. Report No: AMR.2019.BAM.EIA Revision: 00 Chapter 5 - Project Description 5-5 ENVIRONMENTAL IMPACT ASSESSMENT (EIA) October 2019 Proposed Development of Sustainable Scheduled Waste Treatment Center (SSWTC) at PT1682 Bukit Tagar Sanitary Landfill, Mukim Sungai Tinggi, Daerah Hulu Selangor, Selangor Darul Ehsan for Berjaya Alam Murni Sdn. Bhd. WTE Thermal Treatment Plant Oil Recovery Facility Surface Water Treatment Plant Secure Landfill Storage Facility Solidification Facility Leachate Treatment Plant Figure 5.3: Overall Layout of SSWTC Facility within the Area of 40 acres Report No: AMR.2019.BAM.EIA Revision: 00 Chapter 5 - Project Description 5-6 ENVIRONMENTAL IMPACT ASSESSMENT (EIA) October 2019 Proposed Development of Sustainable Scheduled Waste Treatment Center (SSWTC) at PT1682 Bukit Tagar Sanitary Landfill, Mukim Sungai Tinggi, Daerah Hulu Selangor, Selangor Darul Ehsan for Berjaya Alam Murni Sdn. Bhd. The SSWTC components showing its respective area size is shown in Table 5.1 which includes the main treatment and disposal facilities, the associated facilities as well as other supporting infrastructures. Table 5.1: SSWTC Components with its Area Size No. Building or Facilities Dimension Area Size (m2) Main Treatment and Disposal Facilities 1. WTE Thermal Treatment (80m x 70m) 5,600 Plant 2. Secure Landfill (100m x 100m) (Cell 1) 10,000 Overall: ≈ 20 acres ≈ 40,000 Associated Facilities 3. Storage Facility (55m [L] x 110m [W]) 6,050 4. Solidification Facility (30m [L] x 70m [W]) 2,100 5. Oil Recovery Facility (15m [L] x 10m [W] + 5m [W]) 225 6. 7. Leachate Treatment Plant (20m [L] x 60m [W]) 1,200 (LTP) 8. Surface Water Treatment (6m [L] x 12m [W]) 75 Plant (SWTP) Other Supporting Infrastructures 9. Logistic and Security Office (4.5m [L] x 10.5m [W]) 47.25 10. Administration and (13.37m [L] x 28.78m [W]) 348.72 Laboratory 11. Changing Room and Canteen (12m [L] x 24m [W]) 288 12.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages50 Page
-
File Size-