Wessex LTPP Route Study Guildford – Station Capacity Pre-GRIP Feasibility Report - Addendum

Wessex LTPP Route Study Guildford – Station Capacity Pre-GRIP Feasibility Report - Addendum

Wessex LTPP Route Study Guildford – Station Capacity Pre-GRIP Feasibility Report - Addendum 29 November 2016 Issue 2.6 Addendum Contents 1. Executive Summary .............................................................................................................. 7 2. Background ........................................................................................................................... 8 2.1 Future Train Service Aspirations ................................................................................... 9 3. Methodology ........................................................................................................................ 12 4. Constraints .......................................................................................................................... 13 4.1 Existing Station Overview ............................................................................................ 13 4.2 Flooding Risk ............................................................................................................... 14 4.3 Buried/Other Services .................................................................................................. 15 4.4 Land Ownership/Development .................................................................................... 15 4.5 Environmental/Heritage considerations ....................................................................... 18 4.6 Ground Conditions ....................................................................................................... 18 4.7 Threats & Opportunities ............................................................................................... 18 4.7.1 Solum Development ....................................................................................... 18 4.7.2 Farnham Road Bridge .................................................................................... 20 4.7.3 North Downs Line Electrification .................................................................... 21 5. Addendum Options for Increasing Guildford Station Capacity ...................................... 22 5.1 Options Overview ........................................................................................................ 22 5.1.1 Option 1 – New bay platform P0 to east ........................................................ 22 5.1.2 Option 2 – New island platform to east .......................................................... 22 5.1.3 Option 3 – New viaduct .................................................................................. 22 5.1.4 Option 4 – Terminating platform at Guildford’s London Road Station ........... 23 5.1.5 Option 5 – Extend platform P2 to the south and construct a new island platform to the north ....................................................................................... 23 5.1.6 Option 6 – Construct a raised platform P0 above existing platforms P1 & P2 on the east side of the station. ....................................................................... 23 5.1.7 Option 7 – Track re-configuration to north and a new side platform P0 ........ 23 5.2 Options Summary ........................................................................................................ 25 5.3 Option 1 – New bay platform P0 to East ...................................................................... 26 5.3.1 Option 1A – New bay platform P0 to east with reduced platform P1/P2 width26 5.3.2 Construction Considerations .......................................................................... 26 5.3.3 Permanent Way Considerations .................................................................... 27 5.3.4 General Items ................................................................................................ 27 5.3.5 Bill of Quantities ............................................................................................. 27 5.4 Option 2 ....................................................................................................................... 31 5.4.1 Option 2A ....................................................................................................... 31 5.4.2 Construction Considerations .......................................................................... 32 5.4.3 Permanent Way Considerations .................................................................... 32 5.4.4 General Items ................................................................................................ 32 5.4.5 Bill of Quantities ............................................................................................. 33 Guildford Station – Station Capacity – Addendum version 2.6 29th November 2016 Network Rail Infrastructure Projects - Strictly Private and Confidential 5.5 Option 3 ....................................................................................................................... 36 5.5.1 Construction Considerations .......................................................................... 36 5.5.2 Permanent Way Considerations .................................................................... 37 5.5.3 General Items ................................................................................................ 37 5.5.4 Bill of Quantities ............................................................................................. 38 5.6 Option 4 ....................................................................................................................... 41 5.7 Option 5 ....................................................................................................................... 41 5.8 Option 6 ....................................................................................................................... 41 5.9 Option 7 ....................................................................................................................... 42 5.9.1 Construction Considerations .......................................................................... 43 5.9.2 Permanent Way Considerations .................................................................... 43 5.9.3 General Items ................................................................................................ 44 5.9.4 Bill of Quantities ............................................................................................. 44 6. General Construction Considerations for all options ..................................................... 47 6.1 Construction Methodology ........................................................................................... 47 6.2 Construction Programme ............................................................................................. 47 7. Electrical System ................................................................................................................ 49 7.1 Background .................................................................................................................. 49 7.2 Intervention .................................................................................................................. 49 7.3 25kV OLE Electrification .............................................................................................. 49 7.4 750V DC Electrification ................................................................................................ 51 7.5 Specific Areas to Note ................................................................................................. 52 7.5.1 Guildford ........................................................................................................ 52 7.6 Power Supply ............................................................................................................... 52 7.6.1 Security of Power Supply ............................................................................... 53 7.7 Options 1 and 2 Specific DC Electrification Issues ...................................................... 54 7.8 Option 3 Specific DC Electrification Issues .................................................................. 54 7.9 Options 4 to 7 Specific DC Electrification Issues ......................................................... 55 7.10 Signalling ..................................................................................................................... 56 7.10.1 Operational Requirements Specification ........................................................ 56 7.10.2 SSI Interlocking capacity ................................................................................ 56 7.10.3 Ergonomics .................................................................................................... 56 7.10.4 Layout, Signal Positioning and Sighting ......................................................... 56 7.10.5 Train Dispatch ................................................................................................ 56 7.10.6 DC Immunity and EMC .................................................................................. 56 7.10.7 Train Detection ............................................................................................... 56 7.10.8 Point Operating Equipment ............................................................................ 57 7.10.9 Train Protection and Warning System (TPWS) ............................................. 57 7.10.10 Signalling Maintenance and “PRAMS” ........................................................... 57 7.10.11 Summary .......................................................................................................

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    61 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us