Renovation General Notes Definitions & Terminology a a 9

Renovation General Notes Definitions & Terminology a a 9

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 B A U E R GENERAL NOTES RENOVATION GENERAL NOTES DEFINITIONS & TERMINOLOGY A A 9. BUILDING SYSTEMS: 18. PARTITIONS: 1. CONTRACTUAL OBLIGATION: THE GC SHALL COORDINATE THE LOCATION AND PARTITIONS EXTENDING TO THE STRUCTURE ABOVE SHALL BE 1. PROTECTION OF EXISTING TO REMAIN: 1. "TYPICAL": 6 1 5 THE GC SHALL ABIDE BY AND BE RESPONSIBLE FOR ALL INSTALLATION OF ALL BUILDING SYSTEMS AND EQUIPMENT. TIGHTLY SEALED. THE INTEGRITY OF RATED ASSEMBLIES AND THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR UNLESS NOTED OTHERWISE, MEANS IDENTICAL FOR ALL T 7 2 6 . 0 0 4 7 CONDITIONS, WHICH MATCH ORIGINAL CONDITION REQUIREMENTS STATED IN THE AIA DOCUMENT A201 - THE GC SHALL COORDINATE ALL BUILDING TRADES TO ASSURE SMOKE BARRIERS SHALL BE MAINTAINED AT CORNERS AND CARPET, FURNISHINGS, AND FINISHES IN EXISTING AREAS NOT F 7 2 6 . 4 8 9 1 INDICATED. GENERAL CONDITIONS (CURRENT ISSUE), UNLESS NOTED ALL REQUIRED CLEARANCES FOR OPERATION AND INTERSECTIONS OF LOWER PRIORITY PARTITIONS. ALL DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. THE 6 1 5 OTHERWISE. MAINTENANCE OF ALL EQUIPMENT AND SYSTEMS AS CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY HORIZONTAL AND VERTICAL FIRE AND/OR SMOKE BARRIERS, 2. "SIMILAR": REQUIRED BY CODE, THESE DOCUMENTS, OR INCLUDING ALL FLOOR STRUCTURES, SHALL BE CONTINUOUS DAMAGE CAUSED BY HIS WORK OR ANY SUBCONTRACTOR. 1 6 1 5 B IN PARTICULAR, THE CONTRACTOR SHALL MAINTAIN A DUST-FREE MEANS COMPARABLE CHARACTERISTICS FOR THE CONDITIONS B 2. GENERAL CONDITIONS: MANUFACTURER'S RECOMMENDATIONS ARE MET OR FROM OUTSIDE WALL TO OUTSIDE WALL, FROM ONE BARRIER ENVIRONMENT WITHIN THE MAGNET VAULT. NOTED. VERIFY DIMENSIONS AND ORIENTATION OF THE GC SHALL PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, EXCEEDED. LACK OF SPECIFIC DETAILS SHALL NOT BE AN TO ANOTHER, OR COMBINATION THEREOF. BARRIERS MUST CONDITIONS, WHICH VARY FROM TYPICAL OR SIMILAR TOOLS, UTILITIES, INSURANCE, TRANSPORTATION, AND PAY EXCUSE FOR IMPROPER INSTALLATION OF ANY MATERIAL, BE CONTINUOUS THROUGH CONCEALED SPACES AND 2. SCHEDULING CONDITION INDICATED. FOR ALL REQUIRED TAXES, PERMITS, AND SERVICES REQUIRED DEVICE, OR SYSTEM. WHERE DETAILS ARE NOT PROVIDED, THE INTERSTITIAL SPACES. SEAL COMPLETELY ALL OPENINGS WITH THE CONTRACTOR SHALL MEET WITH THE OWNER'S TO COMPLETE THE ENTIRE SCOPE OF WORK, WHETHER GC SHALL REFER TO THE PRINTED MANUFACTURER'S UL (OR OTHER TESTING AGENCY) APPROVED ASSEMBLIES AUTHORIZED REPRESENTATIVE WELL IN ADVANCE OF 3. "OPPOSITE HAND": TEMPORARY OR PERMANENT. ALL MATERIALS EXCEPT RECOMMENDATIONS FOR INSTALLATION GUIDLINES. ALL WHERE FIRE BARRIERS ARE PENETRATED OR ABUT OTHER FIRE CONSTRUCTION COMMENCEMENT TO: MEANS CONDITION IS MIRROR IMAGE OF DETAILED REFERENCED. 3 7 2 1 2 TEMPORARY FORMS ARE TO BE NEW, UNUSED AND OF THE INSTALLED SYSTEMS AND DEVICES ARE TO OPERATE QUIETLY BARRIERS, EXTERIOR WALLS, AND FLOORS ABOVE AND BELOW C C SPECIFIED QUALITY. THE GC SHALL MAINTAIN THE PROJECT AND WITHOUT EXCESSIVE VIBRATION. THIS INCLUDES BUT IS BARRIER. ALL FIRE BARRIERS ARE TO BE CONSTRUCTED A. SCHEDULE, SEQUENCE AND COORDINATE ALL WORK 4. "ALIGN": SITE IN A CLEAN AND ORDERLY FASHION. TOOLS AND NOT LIMITED TO THE FOLLOWING SYSTEMS; MECHANICAL, ACCORDING TO THE TESTING LABORATORY SPECIFICATIONS. MEANS ALIGNMENT OF SIMILAR COMPONENTS OF CONSTRUCTION (WALLS,JAMBS,ETC), WHICH ARE ADJACENT OR EQUIPMENT SHALL BE SECURED, AND ALL DEBRIS SHALL BE ELECTRICAL, LIGHTING, PLUMBING, AND TELEPHONE ALL SMOKE BARRIERS SHALL BE A MINIMUM OF 1-HOUR FIRE B. MAINTAIN EXITS AND EGRESS WIDTHS REQUIRED BY THE COMPONENTS SHALL BE IN LINE WITH EACH OTHER REMOVED DAILY. THE GC SHALL MAINTAIN A VISITORS LOG. EQUIPMENT. RESISTANT CONSTRUCTION. CORRIDOR PARTITIONS, SMOKE CODES DURING ALL PHASES OF CONSTRUCTION ACROSS VOIDS. DIMENSIONS ARE NOT ADJUSTABLE UNLESS ALL VISITORS SHALL BE REQUIRED TO SIGN SUCH LOG. DATES STOP PARTITIONS, HORIZONTAL EXIT PARTITIONS, EXIT NOTED WITH PLUS/MINUS TOLERANCE. AND TIMES OF ENTERING AND EXITING THE SITE FOR ALL 10. CLEARANCES: ENCLOSURES, AND ALL FIRE RATED WALLS SHALL BE 3. CLEARANCES VISITORS SHALL BE NOTED. GC TO SECURE PROJECT SITE THE CONTRACTOR SHALL COORDINATE WITH ALL BUILDING THE CONTRACTOR SHALL VERIFY THAT NEW CEILINGS CAN BE PERMANENTLY IDENTIFIED WITH STENCILING. SUCH 5. "O.F.O.I.": D INSTALLED IN EXISTING SPACES TO CLEAR DUCTWORK AND D FROM UNAUTHORIZED ENTRY AT ALL TIMES. COORDINATE TRADES INVOLVED IN THE PROJECT FOR PREPARATION OF IDENTIFICATION SHALL BE ABOVE ANY DECORATIVE CEILING OTHER CONSTRUCTED ITEMS AND MAINTAIN FLOOR TO CEILING MEANS "OWNER FURNISHED, OWNER INSTALLED" LOCATION OF BARRICADES OR TEMPORARY FENCING WITH COMPOSITE SHOP DRAWINGS FOR EACH FLOOR TO INSURE AND IN CONCEALED SPACES. STENCILING TO BE IN RED HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR THE DOCUMENTS AND OWNER. THE GC SHALL PROPER CLEARANCES FOR FIXTURES, DUCTS, CEILINGS, ETC, LETTERS, NO LESS THAN 4" TALL WITH A RED BAND EXTENDING DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT 6. "U.N.O.": PHOTOGRAPH THE PROJECT SITE AND EXISTING CONDITIONS WHILE MAINTAINING THE SPECIFIED CEILING HEIGHTS NOTED THE LENGTH OF THE PARTITION. STENCILED IDENTIFICATION BEFORE PROCEEDING. MEANS "UNLESS NOTED OTHERWISE" PRIOR TO THE BEGINNING OF THE WORK. PHOTOGRAPHS ON THE DRAWINGS. CLARIFY ANY CONFLICTS WITH TO READ "(X) HOUR RATED FIRE AND/OR SMOKE BARRIER, SHALL BE TAKEN OF THE PROGRESS OF THE WORK AT ARCHITECT. PROTECT ALL OPENINGS". STENCILED IDENTIFICATION TO BE 4. MATERIAL ALIGNMENT 7. "O.F.C.I.": INTERVALS NO GREATER THAN 7 CALENDAR DAYS. POSITIONED TO BE READILY VISIBLE FROM BOTH SIDES OF THE THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN MENAS "OWNER FURNISHED, CONTRACTOR INSTALLED" E PHOTOGRAPHS SHALL BE IN COLOR AND IDENTIFIED BY DATE 11. LOCATIONS: BARRIER AND SUCH THAT FROM ANY ACCESS POINT AT LEAST ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE E AND TIME OF DAY. MAINTAIN DIGITAL PHOTOGRAPH FILE ON ELECTRICAL PANELS, TELEPHONE EQUIPMENT, FIRE ONE IDENTIFICATION MARKER MAY BE READ. MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, 8. REFERENCES: SITE. DELIVER COMPLETED FILE TO THE ARCHITECT UPON EXTINGUISHERS, FIRE PULLS, LIGHTS/HORNS, SMOKE UNLESS NOTED OTHERWISE. ALL REFERENCES TO CONTRACTOR SHALL REFER TO GENERAL CONTRACTOR AND/OR SUB CONTRACTOR. ALL REFERENCES RECEIPT OF USE AND OCCUPANCY PERMIT. THE GC SHALL DETECTORS, THERMOSTATS, ETC, SHALL BE LOCATED IN 19. PENETRATIONS: TO THE OWNER SHALL MEAN THE OWNER OR THE OWNER'S MAINTAIN AN ON SITE STAGING AREA AND SHALL KEEP THE ACCORDANCE WITH REQUIREMENTS OF GOVERNING PENETRATIONS OF PIPES, TUBES, CONDUIT, WIRES, CABLES, 5. AS BUILT VERIFICATION AGENT. AGENCY APPROVED CONSTRUCTION DOCUMENTS, ALL AGENCIES. ANY LOCATION NOT SPECIFICALLY SHOWN DUCTS, VENTS, CABINETS, LIGHTING, AND OTHER FIXTURES THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT LICENSING INFORMATION, VISITORS LOG, PHOTOGRAPH FILE, SHALL BE VERIFIED WITH ARCHITECT PRIOR TO ROUGH-OUT THROUGH FIRE RATED ASSEMBLIES SHALL BE INSTALLED AND CONDITIONS, AND NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE F AND AT LEAST ONE SET OF REPRODUCIBLE CONSTRUCTION AND INSTALLATION. UNLESS OTHERWISE NOTED, THE ABOVE PROTECTED TO MAINTAIN FIRE RATING. F CONSTRUCTION DOCUMENTS IS BASED ON FIELD DOCUMENTS, TO BE MARKED CONCURRENTLY WITH THE PANELS AND/OR EQUIPMENT SHALL BE FULLY RECESSED & OBSERVATIONS AND/OR THE ORIGINAL CONSTRUCTION CONSTRUCTION, TO RECORD ACTUAL CONDITIONS OF THE SHALL MAINTAIN THE INTEGRITY OF WALL FIRE RATING 20. PROTECTION OF FLOOR SURFACES: DOCUMENTS OF THE FACILITY. CONSTRUCTION AND DEVICE INSTALLATIONS. DELIVER REQUIREMENTS. CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR COMPLETED REPRODUCIBLE RECORD SET TO THE ARCHITECT ALL FINISHED FLOOR SURFACES, EXISTING OR NEW 6. REMOVAL SURVEY UPON COMPLETION OF THE PROJECT. GC TO REMOVE AND 12. GOVERNING AGENCIES: INCLUDING BUT NOT LIMITED TO, CERAMIC TILE, VINYL TILE, THE CONTRACTOR SHALL SURVEY AND DETERMINE THE REMOVAL DISPOSE OF ALL WASTE AND DEBRIS FROM PROJECT SITE IN A THE GC AND ALL OF HIS FORCES SHALL COMPLY WITH ALL CONCRETE, ETC., THROUGHOUT THE CONSTRUCTION OF EXISTING CONSTRUCTION, EITHER WHOLE OR IN PART, AS LEGAL MANNER. UPON COMPLETION OF THE WORK, G REGULATIONS BY ANY GOVERNING AGENCY WITH PERIOD. REQUIRED FOR THE INSTALLATION OF THE NEW MECHANICAL, G PROVIDE PROFESSIONAL CLEANING SERVICE TO CLEAN THE JURISDICTION OVER THE PROJECT OR PROJECT SITE. PLUMBING AND ELECTRICAL WORK. PROJECT SITE, INTERIOR AND EXTERIOR, FOR FINAL 21. COMMUNICATION EQUIPMENT: OCCUPANCY. 13. PERMITS/INSPECTIONS: THE GC SHALL COORDINATE THE WORK HE IS RESPONSIBLE 7. CONSTRUCTION DEFECTS: UNLESS OTHERWISE PROVIDED IN THE CONTRACT FOR WITH THE OWNER'S COMMUNICATION SERVICE THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF 3. GRAPHICS: DOCUMENTS, THE CONTRACTOR SHALL SECURE AND PAY FOR PROVIDERS. COORDINATE THE LOCATION OF ALL SYSTEM ANY CONSTRUCTION DEFECTS FOUND IN UNCOVERING WORK EXISTING CONSTRUCTION (PARTITIONS , DOORS, PLUMBING THE BUILDING PERMIT AND OTHER PERMITS AND CONTOLS WITH THE ELECTRICAL SYSTEM INSTALLER, THE IN THE EXISTING CONSTRUCTION. FIXTURES, CASEWORK, EQUIPMENT, ETC.) IS INDICATED ON GOVERNMENTAL FEES, LICENSES AND INSPECTIONS OWNER, AND THE ARCHITECT PRIOR TO INSTALLATION. H 8. CORRECTING DEFECTIVE WORK H THE FLOOR PLANS, WITH LINES IN A LIGHTER SHADE NECESSARY FOR PROPER EXECUTION AND COMPLETION OF OWNER'S COMMUNICATION PROVIDER TO ASSURE THAT THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING (SCREENED). EXISTING WALLS TO REMAIN ARE POCHED. NEW

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    8 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us