
EXO-26 Balanced Regulator Full Face Mask User Guide Part #: 100-131 Kirby Morgan Dive Systems, Inc. 1430 Jason Way Santa Maria, CA 93455, USA Telephone (805) 928-7772 FAX (805) 928-0342 E-Mail: [email protected] Web Site: www.KirbyMorgan.com © ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. This manual is made available for the express use of owner of this Kirby Morgan® product. No part of this manual may be reproduced, stored in any retrieval system, or transmit- ted, or used in any form or by any means, whether graphic, electronic, mechani- cal, photocopy, or otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc. EXO® is a Registered Trademark of Kirby Morgan Document # 120613002 Warranty Information Kirby Morgan Dive Systems, Inc. warrants every new mask, helmet, or KMAC Air Control System to be free from defects in workmanship for a period of three hundred sixty five (365) days from date of purchase. This warranty covers all metal, fiberglass, and plastic parts. This warranty does NOT cover rubber parts, communications components, or head cushions. In addition, due to the electrolytic nature of underwater cutting and welding, chrome plating cannot be warranted when the diver engages in these activities. Should any part become defective, contact the nearest autho- rized KMDSI dealer. If there is no dealer in your area, contact KMDSI directly at (805) 928-7772. You must have a return authorization from KMDSI prior to the return of any item, Upon approval from KMDSI, return the defective part, freight prepaid, to the KMDSI plant. The part will be repaired or replaced at no charge as deemed necessary by KMDSI. This warranty becomes null and void if: 1) The product is not registered with KMDSI within ten (10) days of purchase. 2) The product has not been properly serviced and/or main- tained according to the appropriate KMDSI manual. In addition, the user is responsible to ensure that all product updates as recommended by KMDSI have been performed. 3) Unauthorized modifications have been made to the prod- uct. 4) The product has been abused or subjected to conditions which are unusual or exceed the product’s intended service. NOTE: Be sure to complete the enclosed warranty card and return it to KMDSI immediately. No warranty claims will be honored without a satisfactorily completed warranty card on file at KMDSI. 2 © ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613002 Definition of Signal Words Used in this Manual For your protection, pay particular attention to items identified by signal words in this manual. These terms are identified as, CAU- TION, WARNING and DANGER. It is especially important for you to read and understand these sections. B DANGER This word indicates an imminently hazardous situation, which if not avoided, could result in death or serious injury. B WARNING This word indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury. B CAUTION This word indicates a potentially hazardous situation, which if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. NOTICE This word is used to address practices not related to personal injury. © ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613002 3 Table Of Contents Warranty Information ������������������������������������������ 2 Definition of Signal Words Used in this Manual �������������� 3 Chapter 1 EXO-26 Balanced Regulator Full Face Mask ����� 10 1.1 Introduction ����������������������������������������������� 10 1.2 Design Purpose ������������������������������������������� 12 1.3 Specifications ��������������������������������������������� 13 Chapter 2 Operating Instructions ���������������������������� 14 2.1 Receiving The Mask �������������������������������������� 14 2.2 Before You Dive! ������������������������������������������ 14 2.3 Visual Inspection ������������������������������������������ 14 2.4 Clean The Face Port �������������������������������������� 15 2.5 Adjusting The Equalizer ���������������������������������� 15 2.6 Checking Regulator Functions And Preparing The Mask For Use ������������������������������������������������������� 15 2.7 First Stage Regulator ������������������������������������� 17 2.8 Overpressure Relief Valve �������������������������������� 17 2.9 Recommendations For Donning Or Removing The Exo-26 ................................................................. 18 2.10 Donning The Mask ��������������������������������������� 18 2.11 Removing The Mask ������������������������������������� 19 2.12 Proper Hood Fit ������������������������������������������ 19 Chapter 3 In Water Operations ������������������������������� 21 3.1 Introduction ����������������������������������������������� 21 3.2 Water Entry ������������������������������������������������ 21 3.3 Regulator Adjustment ������������������������������������� 21 3.4 Spider Adjustment ���������������������������������������� 21 3.5 Purging Water From The Mask ��������������������������� 22 Chapter 4 Post Dive Procedures ����������������������������� 23 4.1 Post Dive Rinse ������������������������������������������� 23 4.2 Reassembly Of The Mask ��������������������������������� 23 4.3 Periodical Maintenance Of The Mask �������������������� 24 Chapter 5 Communications ���������������������������������� 25 4 © ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613002 B WARNING Follow all the instructions in this manual carefully and heed all safety precautions. Improper use of this diving mask could result in serious injury or death. B WARNING Diving is a life threatening occupation. Even if you do ev- erything right you can still be killed or injured. None of the models of Kirby Morgan helmets or masks can prevent acci- dents, injuries or death due to improper training, poor-health, improper supervision, improper job requirements, improper maintenance or acts of God. If you have any questions concerning this manual, contact KMDSI (805) 928- 7772 or by Email at [email protected] or Dive Lab Inc. (850) 235-2715 or at [email protected] B CAUTION Kirby Morgan Dive Systems, Inc. declines all responsibility for accidents due to an incomplete understanding of the equip- ment. B CAUTION This mask should be used only with breathing air meeting requirements of EN132 standard, Appendix A. NOTICE This mask should be used only with equipment and accesso- ries which are approved according to EN250. B CAUTION This mask should be used only with equipment using open circuit compressed air. The use of an oxygen enriched atmo- sphere is dangerous and not allowed © ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613002 5 NOTICE In accordance with the EN250 standard, the maximum ap- proved depth for the use of the equipment is 50 meters (164 feet). B CAUTION Never use a solvent to clean the mask. Never use aerosol sprays on or around the mask as certain solvents and propul- sion agents attack and damage rubber and certain plastics. B CAUTION In order to use this mask it is ABSOLUTELY NECESSARY that you follow a training course and RECEIVE CERTIFICATION, issued by a competent training organization, confirming your ability to dive. Use of a mask by untrained and unqualified per- sonnel is DANGEROUS and could lead to serious accidents, and/or death. Use of this equipment by a person who does not possess certification issued by an appropriate organization renders void any guarantee, express or implied, on this prod- uct. This mask, as supplied, is intended to be used for Scuba diving. Before each use the mask should be carefully checked and submitted to the operational tests. NEVER DIVE with a mask showing any signs of deterioration or which has a below nor- mal performance. NOTICE The hoses fitted to the EXO-26 Full Face Mask, and supplied by KMDSI, meet the requirements of the EN250 standard concerning the connection of components. Only origional Kirby Morgan hoses should be used as replacements. - HP thread 7/1 6" - 20 UNF - MP thread 3/8" - 24 UNF Always allow pressure to build up slowly in the regulator by turning on the cylinder valve SLOWLY. 6 © ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613002 Use only silicone grease on the rubber components. Never grease the parts of your mask with a lubricant containing hydrocarbons, household oil, or motor oil. Before diving in cold water (water temperature below 10°C / 50°F), you should first obtain specialized training and certification in the appropriate techniques from a competent organization. You should also use equipment intended for this purpose. The use of a CE approved first stage regulator with a silicone oil chamber will reduce the possibility of first stage icing causing failure. Also, the diver should have been trained and have mastered the techniques of cold water diving so as to be able to take all precautions necessary to avoid freezing of the regulator. All of this is included in the training programs of organizations offering courses in diving in cold water or under ice. In order to reduce the risks of regulator freezing when diving in cold water (below 10°C), consider doing the following: 1 - Protect your regulators from any accidental ingress of water into the first or second stages. 2 -Protect your equipment from cold before the dive. More precisely, keep your mask and all its accessories in a warm dry place. 3 - Carry out all
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages27 Page
-
File Size-