INSTALLATION INSTRUCTIONS EMPIRE AND OWNER'S MANUAL Comfort Systems Vented/Vent-Free Burner UNVENTED GAS LOG HEATER OR INTERMITTENT MODELS VFSE-(18,24,30)-1 VARIABLE MODELS VFSV-(16,18,24,30)-4 VENTED DECORATIVE APPLIANCE VARIABLE MODELS VFSV-(16,18,24,30)-4 GAS-FIRED This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, Installer: Leave this manual with the appliance. where not prohibited by local codes. Consumer: Retain this manual for future reference. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury This is an unvented gas-fired heater. It uses air (oxy- or loss of life. gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be — Do not store or use gasoline or other flammable provided. Refer to page 6. vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS WARNING: If not installed, operated and maintained • Do not try to light any appliance. in accordance with the manufacturer's instructions, • Do not touch any electrical switch; do not use this product could expose you to substances in fuel any phone in your building. or from fuel combustion which can cause death or • Immediately call your gas supplier from a serious illness. neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM fire department. HEATERS — Installation and service must be performed by a Water vapor is a by-product of gas combustion. An qualified installer, service agency or the gas sup- unvented room heater produces approximately one (1) plier. ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour. Refer to page 44. Page 1 BEFORE YOU START 1. Read the safety information on Page 41. 2. If located in the Commonwealth of Massachusetts, please note the special requirements on page 44. 3. Install the gas lines. See page 12. 4. Fireplace sizing, see page 7. 5. Install the burner. See page 11. 6. Air shutter setting, see page 5. 7. Install the remote system. VFSE, see page 15, VFSV, see page 33. 8. Install the logs and embers. See page 13. 9. Light the burner. VFSE, see page 14. VFSV, see page 32. 10. Troubleshooting. VFSE, see page 23. VFSV, see page 40. 11. Show the homeowner how to operate the burner. VFSE, see page 15. VFSV, see page 33. 12. Show the homeowner how to do the basic maintenance. VFSE, see page 28. VFSV, see page 36. Page 2 28092-8-0614 TABLE OF CONTENTS SECTION PAGE Introduction ..............................................................................................................4 Product Specifications ..............................................................................................5 Accessories ..............................................................................................................5 Provisions for Adequate Combustion & Ventilation Air .............................................6 Clearances ............................................................................................................7-8 Combustible Material ...............................................................................................9 Fireplace Preparation .............................................................................................10 Installing as a Vented Appliance ............................................................................11 Before Fully Installing the Appliance ......................................................................11 Gas Supply .............................................................................................................12 Placement of Glowing Embers and Lava Rock ......................................................13 Operation Instructions/Flame Appearance .............................................................13 VFSE-(18,24,30) Lighting Instructions ...................................................................14 VFSE Remote Electronic Ignition and Control System .....................................15-22 Intermittant Troubleshooting ..............................................................................23-27 Cleaning and Servicing ..........................................................................................28 Pilot Flame Characteristitcs ...................................................................................29 VFSE Parts View ....................................................................................................30 VFSE Parts List ......................................................................................................31 VFSV-(16,18,24,30) Lighting Instructions ..............................................................32 VFSV Remote Control Instructions ...................................................................33-34 Pilot Flame Characteristitcs ...................................................................................35 Cleaning and Servicing ..........................................................................................36 VFSV Parts View ....................................................................................................38 VFSV Parts List ......................................................................................................39 Troubleshooting ......................................................................................................40 Important Safety Information ..................................................................................41 Safety Information for Users of LP-Gas .................................................................42 Requirements for Canada ......................................................................................43 General Information ...............................................................................................44 Water Vapor: A By-Product of Unvented Room Heaters ........................................44 Master Parts Distributor List ...................................................................................45 How To Order Repair Parts ....................................................................................45 Warranty .................................................................................................................46 Appliance Service History ......................................................................................47 28092-8-0614 Page 3 INTRODUCTION IMPORTANT: Read all instructions carefully before starting Important installation. Failure to follow these installation instructions may All correspondence should refer to complete Model Number, Serial result in a possible fire hazard and will void the warranty. Number and type of gas. Save this manual for future reference. Attention: During initial use of log you will detect an odor as Please read this manual before installing and using the the log is cured. appliance. Notice: During initial firing of this unit, its paint will bake out, and Instructions to Installer smoke will occur. To prevent triggering of smoke alarms, ventilate 1. Installer must leave instruction manual with owner after the room in which the unit is installed. installation. WARNING: This appliance is for installation only in a solid-fuel 2. Installer must have owner fill out and mail warranty card supplied burning masonry or UL 127 factory-built fireplace or in a listed with unvented room heater/vented decorative appliance. ventless firebox enclosure. It has been design certified for 3. Installer should show owner how to start and operate unvented these installations. Exception: DO NOT install this appliance room heater/vented decorative appliance. in a factory-built fireplace that includes instructions stating Always consult your local Building Department regarding regulations, it has not been tested or should not be used with unvented codes or ordinances which apply to the installation of an unvented gas logs. room heater/vented decorative appliance. This appliance may be installed in an aftermarket* manufactured WARNING: Any modification to this unvented gas heater or (mobile) home, where not prohibited by state or local codes. its controls can be dangerous. Improper installation or use *Aftermarket: Completion of sale, not for purpose of resale, from of the heater can cause serious injury or death from fire, the manufacturer. burns, explosion or carbon monoxide poisoning. This appliance is only for use with the type of gas indicated on the Well Head Gas Installations rating plate. This appliance is not convertible for use with other Some natural gas utilities use "well head" gas. This may affect the gases. Btu output of the unit. Contact the gas company for the heating value. New Installation Contact the manufacturer or your gas company before changing Solid-fuels shall not be burned in a fireplace where a vented decorative spud/orifice size. appliance is installed. A vented decorative appliance must be installed only in a solid- fuel burning fireplace with a working flue and constructed of noncombustible material. Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages48 Page
-
File Size-