PLOT Column Selection

PLOT Column Selection

Allen K. Vickers Applications Engineer Manager December 6, 2000 PLOT Column Selection (or How to Retain Your Gases) Telephone Number: 816-650-0621 Chair Person: Lisa Lloyd WCOT vs. PLOT Stationary Chromatographic Stationary Type Phase Process Phases WCOT Liquid or Gas / Liquid Polysiloxanes gum partition PEG PLOT Solid Gas solid Porous Polymers, adsorption Al2O3, Zeolites, etc. Dial 1-816-650-0621 for e-Seminar Audio Why Use PLOT Columns? • Enhanced retention • Enhanced selectivity • Permit higher initial oven temperatures than WCOT Dial 1-816-650-0621 for e-Seminar Audio PLOT Columns "Solid" Porous Layer Fused Silica Tubing Ideal for the analysis of gases due to their increased retention (k) and unique selectivity (α) compared to WCOT Dial 1-816-650-0621 for e-Seminar Audio WCOT Ethylene Analysis Dial 1-816-650-0621 for e-Seminar Audio PLOT Ethylene Analysis Dial 1-816-650-0621 for e-Seminar Audio Selectivity Interactions in PLOT Phases Shape / Size Surface Zeolites Al2O3 Porous Polymers Bonded Carbon Bonded Silica Molecular Sieves Dial 1-816-650-0621 for e-Seminar Audio J&W / Agilent PLOT Columns • GS-Alumina • HP-PLOT Al2O3 “M” • HP-PLOT Al2O3 “S” • HP-PLOT Al2O3 “KCl” • HP-PLOT MoleSieve • GS-CarbonPLOT • HP-PLOT Q • HP-PLOT U • GS-GasPro Dial 1-816-650-0621 for e-Seminar Audio Al2O3 PLOT Columns •GS-Alumina • HP-PLOT Al2O3 “M” • HP-PLOT Al2O3 “S” • HP-PLOT Al2O3 “KCl” •Different "polarities" due to different salt deactivation treatments Dial 1-816-650-0621 for e-Seminar Audio Surface Interactions in PLOT Columns + + + + + + + + + + + + + neutral δ- δ+ Gas Flow δ- δ+ + + + + + + + + + + + + + • Vapor pressure always plays a leading role in solute interactions Dial 1-816-650-0621 for e-Seminar Audio Dial 1-816-650-0621 for e-Seminar Audio Propylene Impurities Dial 1-816-650-0621 for e-Seminar Audio Crude 1,3-Butadiene Dial 1-816-650-0621 for e-Seminar Audio Extended HC Mixture Dial 1-816-650-0621 for e-Seminar Audio Al2O3 PLOT Column Dimensions Available • “M”, “S” and “KCl” • all available in 0.25, 0.32 and 0.53 mm ID • 15, 30 and 50 meter lengths (depending on ID) • GS-Alumina • available in 0.53 mm ID • 15, 30 and 50 meter lengths Dial 1-816-650-0621 for e-Seminar Audio 0.25 mm ID PLOT Al2O3 “S” Dial 1-816-650-0621 for e-Seminar Audio Al2O3 Column Considerations • Will adsorb water and CO2, affecting retention and resolution. • Recondition at 200°C to restore performance. • Not recommended for analysis of “polar” compounds such as alcohols, sulfurs, ketones, etc. • Upper temperature limit of 200ºC Dial 1-816-650-0621 for e-Seminar Audio Break Number 1 For Questions and Answers Press *1 on Your Phone to Ask a Question Dial 1-816-650-0621 for e-Seminar Audio Molecular Sieve PLOT Columns Size Selectivity )ORZ Zeolite "Backbone" *UDSKLFÃRIÃW\SHÃ.),ÃPROHFXODUÃVLHYH REWDLQHGÃIURPÃWKHÃ,QWHUQDWLRQDOÃ=HROLWH $VVRLFDWLRQÃZHEÃVLWHÃ ZZZL]RRQOLQHRUJ Dial 1-816-650-0621 for e-Seminar Audio Molecular Sieve PLOT Columns • 5Å zeolite for the analysis of fixed and permanent gases: H2, O2, N2, CO, CH4 He, Ne, Ar, Kr, Xe SF6 Dial 1-816-650-0621 for e-Seminar Audio Permanent Gases Dial 1-816-650-0621 for e-Seminar Audio Noble Gases Dial 1-816-650-0621 for e-Seminar Audio Sulfur Hexafluoride Dial 1-816-650-0621 for e-Seminar Audio HP-PLOT MoleSieve • 0.32 and 0.53 mm ID • 15 and 30 meter lengths • Both thin and thick films available • Choose thin film for standard permanent gas analysis • Choose thick film for resolution of argon from oxygen at 35ºC • Upper temperature limit of 350ºC Dial 1-816-650-0621 for e-Seminar Audio Molecular Sieve Column Considerations • Very high retention stationary phase • Can be easily fouled by high MW hydrocarbons and polar compounds • Use pre-column or backflush if necessary • Will adsorb water and CO2 • Columns can be reconditioned by holding at elevated temperature (350ºC) for several hours Dial 1-816-650-0621 for e-Seminar Audio GS-CarbonPLOT • Monolithic carbon layer • Unique selectivity • Phase formed in situ • No particle generation • Extended temperature limit of 360ºC • Not affected by water Dial 1-816-650-0621 for e-Seminar Audio GS-CarbonPLOT Applications • Light hydrocarbons (C1-C5) • Synthesis Gas •H2, CO, CO2, CH4, N2/O2, H2O • Trace CO, CO2 and acetylene in ethylene streams (simplification of ASTM D2505) • Great resolution of air, CO, CO2 and C1-C2 hydrocarbon isomers • Light solvents Dial 1-816-650-0621 for e-Seminar Audio C1 to C3 Hydrocarbons GS-CarbonPLOT 1. Methane 30 m x 0.32 mm I.D., 1.5 µm 2. Acetylene 7 Carrier: He @ 30 cm/s 3. Ethylene Oven: 125°C for 2 min 125°C to 225°C at 20°/min 4. Ethane Injector: Split 1:20, 250°C 5. Propyne Detector: MSD, SIM 6. Propylene 7. Propane 2 4 3 5 6 1 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 Dial 1-816-650-0621 for e-Seminar Audio Natural Gas Mixture GS-CarbonPLOT 1. Methane 30 m x 0.32 mm I.D., 1.5 µm 2. Acetylene Carrier: He @ 30 cm/s 3. Propane Oven: 125°C for 2 min 5 4. iso-Butane 125°C to 350°C at 20°/min 5. n-Butane Injector: Split 1:20, 250°C 3 Detector: MSD, SIM 6. iso-Pentane 7. n-Pentane 4 1 2 7 6 0 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 Dial 1-816-650-0621 for e-Seminar Audio Permanent Gases Column: GS-CarbonPLOT 30 m x 0.32 mm I.D. x 3.0 µm J&W P/N: 113-3133 Carrier: Helium at 27 cm/sec (calculated off N2 at 35°C) Oven: 35°C isothermal Injector: 185°C, 1:30 split, 250 µL injection volume Detector: TCD, 150°C 1 1. Nitrogen and Oxygen (5% each) 2. Carbon monoxide (5%) 2 3. Methane (4%) 4. Carbon dioxide (5%) 3 4 5 2.0 2.5 3.0 3.5 4.0 & Dial 1-816-650-0621 for e-Seminar Audio Solvents 1. Methylene Chloride GS-CarbonPLOT 2. Acetone 30 m x 0.32 mm I.D., 1.5 µm 3. Carbon Disulfide Carrier: He @ 30 cm/s 3 Oven: 125°C for 2 min 4. Ethyl Ether 125°C to 350°C at 20°/min 5. Ethyl Acetate Injector: Split 1:20, 250°C 6. Benzene Detector: MSD, SIM 6 5 1 2 4 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 Dial 1-816-650-0621 for e-Seminar Audio GS-CarbonPLOT • 0.32 and 0.53 mm ID • 15, 30 and 60 meters • 0.32 mm ID available in thin and thick film • Upper temperature limit of 350º/360ºC Dial 1-816-650-0621 for e-Seminar Audio Break Number 2 For Questions and Answers Press *1 on Your Phone to Ask a Question Dial 1-816-650-0621 for e-Seminar Audio Porous Polymer Phases • Retention is a combination of size and surface interactions between the analyte and the porous solid phase. • The polymers are generally homopolymers of divinylbenzene and divinyl-styrene. • N, R, Q, T, U phases Dial 1-816-650-0621 for e-Seminar Audio Agilent Porous Polymer PLOT Columns • HP PLOT-Q • Bonded polystyrene-divinylbenzene • HP PLOT-U • Bonded divinylbenzene/ethylene glycol dimethacrylate • More polar than “Q” Dial 1-816-650-0621 for e-Seminar Audio Dial 1-816-650-0621 for e-Seminar Audio Natural Gas on HP-PLOT Q Dial 1-816-650-0621 for e-Seminar Audio HP-PLOT Q Volatile Solvents Dial 1-816-650-0621 for e-Seminar Audio HP-PLOT Q Consecutive runs for up to 200 headspace injections of alcohol mixture. Excellent stability!! Dial 1-816-650-0621 for e-Seminar Audio HP-PLOT Q After 150 consecutive direct water injections Dial 1-816-650-0621 for e-Seminar Audio HP-PLOT U Volatile Solvents Dial 1-816-650-0621 for e-Seminar Audio HP-PLOT U Impurities in Acetic Acid Dial 1-816-650-0621 for e-Seminar Audio HP-PLOT U Volatile Primary Amines Dial 1-816-650-0621 for e-Seminar Audio Porous Polymer Column Dimensions Available • Both HP-PLOT Q and HP-PLOT U: • 0.32 and 0.53 mm ID • 15 and 30 meter lengths Dial 1-816-650-0621 for e-Seminar Audio GS-GasPro • Silica-based PLOT column • Bonded stationary phase • Unique selectivity • Highly inert to reactive compounds • Retention stability unaffected by water Dial 1-816-650-0621 for e-Seminar Audio GS-GasPro • Upper temperature limit of 260º/300ºC • No particle generation • Applications •CO, CO2 •C1 to C12 hydrocarbons • trace sulfur analysis • hydrides (arsine, phosphine, germane, etc.) • halocarbons • HCl, NH3 Dial 1-816-650-0621 for e-Seminar Audio Dial 1-816-650-0621 for e-Seminar Audio Dial 1-816-650-0621 for e-Seminar Audio Dial 1-816-650-0621 for e-Seminar Audio Dial 1-816-650-0621 for e-Seminar Audio Dial 1-816-650-0621 for e-Seminar Audio Dial 1-816-650-0621 for e-Seminar Audio Dial 1-816-650-0621 for e-Seminar Audio GS-GasPro Dimensions Available • Currently only available in 0.32 mm ID • 5, 15, 30 and 60 meter lengths Dial 1-816-650-0621 for e-Seminar Audio Considerations for PLOT Column Analysis • Inlet issues • split versus direct injection • gas sampling valves • low dead volume • column ID and flow rate • Detector issues • particle generation or “spiking”; particle traps • column ID and flow rate Dial 1-816-650-0621 for e-Seminar Audio Considerations for PLOT Column Analysis • Column issues • selectivity • capacity; overloaded peaks • inertness • temperature limits • Column contamination • efficiency loss; “ghost peaks”; increase in bleed • water, CO2, high molecular weight hydrocarbons? •Carrier gas purifiers Dial 1-816-650-0621 for e-Seminar Audio Wrap-up E-Seminar Questions Thank you for attending Agilent e-Seminars.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    57 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us