Fuel Gas Systems Knowledge Objectives(1 of 2) Knowledge

Fuel Gas Systems Knowledge Objectives(1 of 2) Knowledge

12/20/2013 7 7 Knowledge Objectives (1 of 2) • Explain the impact of fuel gases on fire and Fuel Gas explosion investigations. Systems • Discuss the characteristics of fuel gases. • Identify common fuel gas system components. • Discuss common piping for fuel gas systems in buildings. 7 7 Knowledge Objectives (2 of 2) Skills Objectives • Discuss common appliance and equipment • Conduct a fire and explosion investigation for requirements. fuel gas systems. • Identify fuel gas utilization equipment. • Describe how to investigate fuel gas systems. 7 7 Introduction Fuel Gas Systems (1 of 6) • During every investigation, presence and • Used to: condition of fuel gas systems must be: – Control indoor climate – Examined – Heat water – Documented – Cook • Fires and explosions often result from failures – Provide energy for manufacturing within these systems. 1 12/20/2013 7 7 Fuel Gas Systems (2 of 6) Fuel Gas Systems (3 of 6) • Most common: natural gas and commercial • Natural gas explosion scene. propane • Can act as: – Initial fuel source (escaped or “fugitive” gas) – Initial ignition source – Both fuel and ignition source 7 7 Fuel Gas Systems (4 of 6) Fuel Gas Systems (5 of 6) • Fuel sources • Ignition sources – Fuel involvement usually results from – Pilot lights and open flames from appliances compromised fuel delivery or containment served by fugitive gases systems. – Static arcs from appliances – Fuel that is escaped may be called “fugitive gas.” – Electrical arcs – Arcs from switches or contacts in appliances – Other electrical equipment 7 7 Fuel Gas Systems (6 of 6) Characteristics of Fuel Gases (1 of 4) • Both fuel and ignition source – Fuel gases can serve as both the first fuel and the fuel for the fire. – Fugitive fuel provides fuel for the fire to grow. • Additional fire spread – Fire can spread because of fugitive fuel gas. – Natural gas and propane are common residential fuels. 2 12/20/2013 7 7 Characteristics of Fuel Gases (2 of 4) Characteristics of Fuel Gases (3 of 4) • Natural gas • Commercial propane – Hydrocarbon gas composed primarily of methane – Recovered during the process of refining – Often recovered from underground pockets during petroleum drilling for crude petroleum – 95% propane and propylene and 5% other gases – Lighter than air – Heavier than air – Flammable range 3.9–15% – Flammable range 2.15–9.6% – Ignition temperature of 900°F to 1170°F (482°C to – Ignition temperature of 920°F to 1120°F (493°C to 632°C) 604°C). 7 7 Characteristics of Fuel Gases (4 of 4) Odorization • Other fuel gases • By law, odor is added to LP‐gas and – Commercial butane commercial natural gas. – Propane HD5 – Butyl mercaptan most often used in natural gas – Coke oven gas – Ethyl mercaptan or thiophane in LP‐gas – Hydrogen • Supply company adds it as a safety feature – Acetylene • Can often be smelled during fire investigation 7 7 Gas Systems Natural Gas Systems • Transport fuel gas directly into consumers’ • Transmitted (in this order) through: buildings and appliances – Transmission pipeline • Natural gas is supplied from central location – Main pipelines (mains) – Via underground supply service lines – Service mains or service laterals • LP‐gas is contained in bulk supply, often at consumer’s location. 3 12/20/2013 7 7 LP‐Gas Systems (1 of 5) LP‐Gas Systems (2 of 5) • Storage supply is often located at consumer’s • Tanks are larger than cylinders. site in tanks or cylinders – Cargo tanks are mounted on a chassis and used to • Alternatively, the gas may be in in bulk storage transport LP‐gas. locations offsite and piped underground, – Portable tanks transport LP‐gas, but are not on a similar to natural gas systems. chassis. 7 7 LP‐Gas Systems (3 of 5) LP‐Gas Systems (4 of 5) • Cylinders are upright and tend to be • Container appurtenances: smaller than tanks. – Pressure relief devices – Most frequently used in rural homes – Connections for flow control and businesses, mobile homes, – Liquid level gauging devices recreational vehicles, and for outdoor – Pressure gauges barbeques and motor fuel – Pressure regulators – Vaporizers 7 7 Common Fuel Gas System LP‐Gas Systems (5 of 5) Components (1 of 5) • A vaporizer is used when there is a demand • Pressure regulation (reduction) for large quantities or propane; it converts – e.g., gas meter liquid propane to gas. • Service piping systems – Delivers gas from the main lines to the user • Valves • Gas burners/pilot lights 4 12/20/2013 7 7 Common Fuel Gas System Common Fuel Gas System Components (2 of 5) Components (3 of 5) • A large natural gas meter. • A 20‐inch gas main pipeline. 7 7 Common Fuel Gas System Common Fuel Gas System Components (4 of 5) Components (5 of 5) • Furnace burners and gas control valve. • Water heater pilot line and gas control valve. 7 7 Common Piping in Buildings (1 of 2) Common Piping in Buildings (2 of 2) • Maintain evidentiary value of piping and its • The main shutoff valve components controls the flow of gas – Joints and fittings throughout the entire – Piping installation building. – Main shutoff valves • Prohibited locations per NFPA 54 and other codes – Such as air ducts, chimneys, elevator shafts • Electrical bonding and grounding 5 12/20/2013 7 7 Common Appliance and Equipment Common Appliance and Equipment Requirements (1 of 2) Requirements (2 of 2) • An appliance is compatible with only a certain • Venting and air supply type of gas; gases are not interchangeable. – Exhaust venting prevents buildup of combustion • Appliance installation products. – May need additional regulator – Fresh air from building exterior often necessary – Location where there is easy access and shutdown • Appliance controls – Sufficient clearance between appliance and – For temperature, ignition, and shutoff combustibles – Gas appliance pressure regulators – Gas flow control accessories 7 7 Fuel Gas Utilization Equipment Investigating Fuel Gas Systems • Investigator should be familiar with design • Should be done in systematic, thorough and operation of: manner – Water heaters • Determine whether, and to what extent, – Furnaces system failed – Clothes dryers • Interviews should touch on fuel gas system. – Ranges 7 7 Compliance with Codes and Standards Leakage Causes (1 of 2) • Investigator should determine that codes and • At pipe junctions standards were followed in: – Inadequate threading, improper join, improper – Design use of joint compound – Manufacture • Unlit pilot lights or burners – Construction – Sensing system malfunctions or auto‐shutoff valve – Installation does not operate and gas continues to flow • Additional expertise or resources may be • Uncapped pipes and outlets needed. 6 12/20/2013 7 7 Leakage Causes (2 of 2) Pressure Testing • Malfunctioning appliances and controls • Pressurize the system to isolate damaged – e.g., dirt or debris causes valves to leak sections of piping. • Gas pressure regulators • Gas meters can also be tested. – Failure within internal diaphragm or of seals – If it is safe to reintroduce gas into system – Plugged vents – The meter detects gas escaping from the system. • Corrosion • Physical damage to system 7 7 Locating Leaks (1 of 2) Locating Leaks (2 of 2) • Tests can locate leaks in fuel gas piping • Soap bubble solution test. – Soap bubble test – Use of gas detector survey (“sniffers”) 7 7 Testing Flow Rates and Pressures Underground Migration of Fuel Gases • Should be tested if gas system is suspected to • Gases can travel great distances underground, be involved in fire ignition through: • Can be done in field or at laboratory – Sewer lines • Conducted only by trained, knowledgeable – Electrical and telephone conduits personnel – Drain tiles • Potential ignition sources should be removed • Passing through soil can “scrub” the odorant during testing. out of the gas. 7 12/20/2013 7 7 Summary (1 of 4) Summary (2 of 4) • Fuel gas systems will likely be either natural • Both types of fuel gases will supply fuel to gas or LP‐gas. various appliances that may heat water and • Natural gas systems are generally supplied via the environment and be used for cooking or underground main lines, whereas LP‐gas is various other services. supplied by a consumer tank on the premises. 7 7 Summary (3 of 4) Summary (4 of 4) • Fuel gas systems are often damaged as a • When fuel gases escape underground, they result of other activities occurring in the can be deodorized as a result of the gas structure, allowing fuel gas to escape from the migrating through the ground. system. • Fuel gas system tests should be conducted by trained laboratory technicians. 8.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    8 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us