Low Voltage Switchboards and Switchgear 1.0 CMP Switchboards ................................................................................1-3 1 Standards and Certifications .................................................................................. 1-4 Product Selection ................................................................................................... 1-4 Technical Data and Specifications .......................................................................... 1-5 Layouts and Dimensions ........................................................................................ 1-6 2.0 Pow-R-Line CS Switchboards ...............................................................2-9 2 Standards and Certifications .................................................................................. 2-10 Product Selection and Specifications ..................................................................... 2-10 Layouts and Dimensions ........................................................................................ 2-14 3.0 Pow-R-Line C Switchboards .................................................................3-19 3 Standards and Certifications .................................................................................. 3-21 Product Selection ................................................................................................... 3-22 Technical Data and Specifications .......................................................................... 3-25 4.0 Commercial Metering Switchboards ...................................................4-29 4 Standards and Certifications .................................................................................. 4-30 Product Selection ................................................................................................... 4-30 Dimensions ............................................................................................................ 4-30 5.0 Integrated Facility Switchboards .........................................................5-31 5 Features, Benefits and Functions........................................................................... 5-32 Options .................................................................................................................. 5-32 Standards and Certifications .................................................................................. 5-32 Product Selection ................................................................................................... 5-33 Technical Data and Specifications .......................................................................... 5-41 6.0 Pow-R-Line C Switchboards with 6 Drawout Moulded-Case Circuit Breaker ..............................................6-43 Standards and Certifications .................................................................................. 6-44 Product Selection ................................................................................................... 6-45 Technical Data and Specifications .......................................................................... 6-45 Dimensions ............................................................................................................ 6-45 7.0 Generator Connection Assemblies 7 Generator Quick Connect Switchboards ...........................................7-48 Standards and Certifications .................................................................................. 7-49 Product Selection ................................................................................................... 7-49 Technical Data and Specifications .......................................................................... 7-49 Dimensions ............................................................................................................ 7-49 Customer Service Termination Enclosure ..........................................7-50 Roll-Up Generator Quick Connect Assembly ....................................7-52 8.0 Pow-R-Line C Switchgear .....................................................................8-55 8 Standards and Certifications .................................................................................. 8-58 Optional Breaker Accessories ................................................................................ 8-58 Dimensions ............................................................................................................ 8-60 9.0 Switchboard Accessories and Modifications ......................................9-61 9 Moulded-Case Circuit Breakers Magnum Power Circuit Breakers ........................................................................... 9-64 Trip Units ................................................................................................................ 9-65 Fusible Switches .................................................................................................... 9-71 Surge Protection Devices ...................................................................................... 9-75 Metering ................................................................................................................ 9-76 Low Voltage Switchboards and Switchgear CA015002EN—August 2019 www.eatoncanada.ca 1-1 Low Voltage Switchboards and Switchgear CMP Switchboards CMP-A1 Switchboard CMP-A2 Switchboard Contents 1 Description Page Standards and Certifications ................................... 1-4 2 Product Selection ................................................... 1-4 Technical Data and Specifications ........................... 1-5 3 Layouts and Dimensions ........................................ 1-6 4 5 6 7 8 9 1 CMP Switchboards 1 Product Description Features, Benefits sprinklerproof, & components totally front 1 Eaton’s CMP switchboard and Functions NEMA 3R optional accessible to enable the combines all three The service entrance • Sealing screws, knurled panel to be installed against 1 components of a service panel is CSA® approved thumb screws and the wall. Freestanding option entrance application into a and completely factory padlock hasp is available for 18" deep enclosure. 1 single cell, including a main assembled. Barriers are • Utility ground stud service compartment, a provided to isolate the • Hydro stubs are available All covers are painted 1 utility metering section and main disconnect, the utility • Distribution cell ANSI 61 grey. the distribution feeders, metering compartment accommodates Eaton’s providing the most flexible Busbar System 1 and the distribution Series C and Series G and compact footprint for section into three separate breakers, fusible switches • Tin-plated aluminum the entire service entrance compartments. The design (FDPW), metered switches 1 switchboard. • allows for the assembly up to 200A (FSMC) Silver-flashed copper to be reversed in the field and chassis-mounted • Tin-plated copper 1 Application Description without modification and panelboards to accommodate either top Eaton's CMP switchboard is or bottom entry of service • User metering (refer to Tab Main Breaker 1 ideally suited to commercial entrance cables. 9-Components, or contact Eaton type main breaker, and industrial applications Eaton for more information) maximum 800A (CMP-A1) 1 such as: • Freestanding (18"D Only) • Surge protection devices or 1200A (CMP-A2) with • Light Commercial • Compact and (refer to Tab 9-Components, standard thermal-magnetic or 1 space-efficient or contact Eaton for more solid-state trip units available. • Retail • Top or bottom entry information) The trip unit on the standard 1 • Shopping Plaza • Meets the provincial • Door-Over-Distribution thermal-magnetic breaker and municipal metering • Special Colours may be changed; however, 1 • Shopping Centers requirements all power to the switchboard must be disconnected prior to • Accommodates a variety • Institutions / Schools Enclosure removal of the breaker cover. 1 of utility CTs and PTs • Agricultural The service entrance • CSA approved up to switchboard is standard CSA The main breaker section 1 • Small buildings 800A (CMP-A1) and Type 1 & sprinklerproof, and comes complete with 1200A (CMP-A2) at NEMA 3R is optional. The provisions for padlocking • Sports and entertainment 1 600 Vac CSA Type 1 & sprinkerproof the main breaker and the facilities • Main breaker maximum options are fabricated sealing screws on the front 800A (CMP-A1) and from code gauge formed cover. Grounding is supplied 1 1200A (CMP-A2) galvanized steel, complete with a removable disconnect link to ground the neutral, • Breakers are padlockable with flat covers to form a rigid 1 the service conduit and the to ensure maximum deadfront totally enclosed system ground. security structure. 1 • Standard enclosure All compartments are ratings of CSA Type 1 & designed to make 1 Low Voltage Switchboards and Switchgear CA015002EN—August 2019 www.eatoncanada.ca 1-3 Low Voltage Switchboards and Switchgear CMP Switchboards 1 Utility Metering Compartment Distribution Section Standards and Certifications Product Selection The utility metering The distribution section • CSA C22.2 No. 31 Description Type compartment is designed accepts the installation • CSA C22.2 No. 244 2 to meet the provincial of circuit breakers on a 800A maximum at 600 Vac CMP-A1 • CSA C22.2 No. 229 and municipal utility Pow-R-Line 4 type interior. 1200A maximum at 600 Vac CMP-A2 3 requirements. It is bussed A flat cover is supplied and and pre-drilled to accept any space not occupied by Breaker Accessories
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages82 Page
-
File Size-