Integrating Inverter- Based Resources into Low Short Circuit Strength Systems Reliability Guideline December 2017 NERC | Report Title | Report Date I Table of Contents Preface ...................................................................................................................................................................... iv Preamble .................................................................................................................................................................... v Acknowledgements ................................................................................................................................................... vi Executive Summary .................................................................................................................................................. vii Introduction .............................................................................................................................................................. ix Qualitative Description of System Strength ........................................................................................................... x Variable Energy Resources ..................................................................................................................................... x Wind Turbine Generator Technologies ............................................................................................................. xi Solar Photovoltaic Generator Technologies .................................................................................................... xiii Chapter 1: Qualifying a Weak power System ............................................................................................................ 1 Short Circuit Ratio (SCR) ......................................................................................................................................... 1 Other SCR-Based Metrics ....................................................................................................................................... 2 Weighted Short Circuit Ratio (WSCR) ................................................................................................................. 2 Composite Short Circuit Ratio (CSCR) ................................................................................................................. 2 Short Circuit Ratio with Interaction Factors (SCRIF) ........................................................................................... 2 Application of Metrics using MW vs. MVA ............................................................................................................. 3 Comparison of SCR Methods .................................................................................................................................. 4 Limitations of Screening Metrics ............................................................................................................................ 5 Appropriate use of SCR-based metrics ................................................................................................................... 5 Chapter 2: Issues Associated with Weak Systems ..................................................................................................... 6 Classical Voltage Stability in Weak Grids ................................................................................................................ 6 Control Interactions and Control Instability ........................................................................................................... 7 Control Instability ............................................................................................................................................... 8 Other Modes of Control Instability ..................................................................................................................... 9 Disturbance Ride-Through Capability ................................................................................................................... 11 Ride-Through Requirements ............................................................................................................................. 11 Phase Lock Loop Stability .................................................................................................................................. 13 Chapter 3: Planning Study Considerations ............................................................................................................... 15 Transient Stability Limitations .............................................................................................................................. 15 Electromagnetic Transient Models....................................................................................................................... 16 Study Model Recommendations .......................................................................................................................... 17 Chapter 4: Coordination and Potential Solution Options ........................................................................................ 19 Manufacturer Involvement .................................................................................................................................. 19 NERC | Integrating Inverter-Based Resources into Low Short Circuit Strength Systems | December 2017 ii Table of Contents Potential Solution Options ................................................................................................................................... 20 Chapter 5: Conclusion .............................................................................................................................................. 22 Appendix A: Requirements for EMT Modeling ........................................................................................................ 23 Model Accuracy Features ..................................................................................................................................... 23 Model Usability Features...................................................................................................................................... 23 Appendix B: Challenges with Weak Grid Issues ....................................................................................................... 25 High Penetration of Wind in West Texas ............................................................................................................. 25 Synchronous Condenser and Wind Farm Interactions ......................................................................................... 26 Weak Grid Voltage Stability Issues Interconnecting on Weak Circuits ................................................................ 27 Transformer Energization in Weak Grids ............................................................................................................. 30 Appendix C: References ........................................................................................................................................... 32 Appendix D: List Of Acronyms .................................................................................................................................. 33 NERC | Integrating Inverter-Based Resources into Low Short Circuit Strength Systems | December 2017 iii Preface The North American Electric Reliability Corporation (NERC) is a not-for-profit international regulatory authority whose mission is to assure the reliability and security of the bulk power system (BPS) in North America. NERC develops and enforces Reliability Standards; annually assesses seasonal and long-term reliability; monitors the BPS through system awareness; and educates, trains, and certifies industry personnel. NERC’s area of responsibility spans the continental United States, Canada, and the northern portion of Baja California, Mexico. NERC is the Electric Reliability Organization (ERO) for North America, subject to oversight by the Federal Energy Regulatory Commission (FERC) and governmental authorities in Canada. NERC’s jurisdiction includes users, owners, and operators of the BPS, which serves more than 334 million people. The North American BPS is divided into eight Regional Entity (RE) boundaries as shown in the map and corresponding table below. The North American BPS is divided into eight RE boundaries. The highlighted areas denote overlap as some load-serving entities participate in one Region while associated transmission owners/operators participate in another. FRCC Florida Reliability Coordinating Council MRO Midwest Reliability Organization NPCC Northeast Power Coordinating Council RF ReliabilityFirst SERC SERC Reliability Corporation SPP RE Southwest Power Pool Regional Entity Texas RE Texas Reliability Entity WECC Western Electricity Coordinating Council NERC | Integrating Inverter-Based Resources into Low Short Circuit Strength Systems | December 2017 iv Preamble NERC, as the FERC-certified Electric Reliability Organization (ERO),1 is responsible for the reliability of the Bulk Electric System (BES) and has a suite of tools to accomplish this responsibility, including but not limited to the following: lessons learned, reliability and security guidelines, assessments and reports, the Event Analysis program, the Compliance Monitoring and Enforcement Program, and Reliability Standards. Each entity, as registered in the NERC compliance registry, is responsible
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages47 Page
-
File Size-