Addendum to Rezac Auditorium Lighting Rfp P1617-M-5

Addendum to Rezac Auditorium Lighting Rfp P1617-M-5

ADDENDUM TO REZAC AUDITORIUM LIGHTING RFP P1617-M-5 UNDER BASE BID PART 1. GENERAL 1.0 WORK INCLUDED – ADD THE FOLLOWING: o The Theatrical Contractor shall provide the materials and services of an electrical contractor for a turn-key installation under this contract. o The Theatrical Contractor must visit the site to ensure all items specified and provided in his bid will comply and work with the site conditions. o The Electrical Contractor, as part of this contract section, shall act as a sub contractor to the Theatrical Contractor. o The Electrical Contractor shall disconnect the old dimmer rack, demo existing low voltage control wire and stations, install new dimmer rack, pull new low voltage control wire (provided by the Theatrical Contractor) and test a complete lighting control system as specified herein, attached installation matrix and the circuit schedules. Existing equipment shall remain with the owner for final disposal. Provide and install all other incidental items necessary for the complete and proper operation. o The Electrical Contractor must visit the site to ensure all items specified and provided in his bid will comply and work with the site conditions. o The Electrical Contractor shall furnish all conduit, wire, connectors, hardware and other incidental items necessary for the complete and proper electrical operation of the lighting control system. o The Electrical Contractor shall coordinate all work described in this section with all other applicable specifications. UNDER BASE BID PART 1. GENERAL 2.16 DIMMER MODULES – DELETE THE FOLLOWING: o G. Provide the following: Power Control System to consist of: A. DR1 1 7141A1005-4 SR3-48 - Black Sensor3 48-Module Dimmer Rack - Designed for 3 phase 4 wire and ground operation at a maximum of 800A, 120/208V, 60Hz AC 1 7141A2006-4 SR3-48 DOOR - Black SR3-48 Locking Door with Filter 1 7140A1003 CEM3 - CEM3 Control Module 1 Custom Item Custom label for dimmer rack 48 7050A1031 D20E - Dual 20A Dimmer Module, 500µs rise time (96 Dimmers) Control System to consist of: o Existing Control Console o Equipment Rack 1 QUOTE-10031 RACK - Black 19" rack sized as job requires and to include: quad power box, and blank panels to fill 1 QUOTE-10032 DOOR - Door for Rack 1 7180A1013 ERN2-RM-120 - ERn2 Enclosure Rack-mount 100-120V 1 7180A1005 ERN-RPS - ERn Redundant Power Supply Module - Cannot be used with ERn- NET 1 7180A1009 P-ACP2 - Paradigm Architectural Control Processor 1 7182A1001 P-SPM - Paradigm Station Power Module - supports 32 stations and (1) 500m wire segment 1 2100A2008 PATCH PANEL 24X - 2U 19" rack-mount patch panel with 24 open slots 23 N2027 Cat5e Modular Jack for above Patch Panel 1 PJJ1002 UTP Pass through for patch panel 1 SGE1062 MAP BR2 - 2U Brush Grommet Panel 24 N4035 2' CAT5 Patch cable, black 1 SGN1129-M CISCO SG300-28PP - Cisco Switch - 24 RJ-45 ports of 10/100/1000 PoE+ (180W total allowance) - 2 RJ-45 ports of 10/100/1000 - 2 combo ports of RJ-45 or mini-GBIC/SFP 1 PJPS1012 MAP 1000R - 1000VA / 750W rack-mount UPS o Multi Box Type 1 (Booth) 1 ECPB N/N/N - ETCNet / ETCNet / ETCNet Station with: 2 - RJ-45 (568B) Connectors in XLR cases 1 1064A1039 ECPB PB3 - ETC 3-gang Surface Mount Back Box (3.5" deep) o Multi Box Type (SMP – Catwalk) 2 QUOTE-10024 ECPB DMX Out / NET / NET - DMX Out / Net / Net Control Plug-in Station with: 1 - XLR-5FDM3 DMX Out Connector(s) 2 - RJ-45 (568B) Connector in XLR case 2 1064A1040 ECPB PB4 - ETC 4-gang Surface Mount Back Box (3.5" deep) 1 7099A1050 -U - U-Bolt Pipe-mounting Assembly (1 pair) o Multi Box Type N-GIB (1st, 2nd, 3rd electrics) 3 Custom Item Net Grid Iron Junction Box with 75’ Proplex Net cable secured to existing SO cable to extend from grid iron to SR pipe batten end. (Plug into Portable gateway(s) listed below) o Multi Box Type 4 (Booth) 1 QUOTE-10024 ECPB DMX In / DMX IN / DMX IN - DMX Input / DMX Input / DMX Input Control Plug-in Station with: 3 - XLR-5MDM3 DMX In Connector(s) Labeled as DMX-In 1 Dimmer, DMX-In 2 Catwalk, DMX-In 3 SMP 1 1064A1039 ECPB PB3 - ETC 3-gang Surface Mount Back Box (3.5" deep) o Portable Gateways 4 4261A1103 N3T2G-2F - Portable (Touring) Net3 Only Two Port Output Gateway to Contain: 2 - XLR-D5F, 5-pin Female XLR connectors with hanger bracket for c-clamp or U-bolt Configure both connectors as “Outputs, DMX universe 1” Install in Catwalk, 1st, 2nd, 3rd Electrics with all necessary cables as required 4 7060A2009 400CC - Black C-Clamp 4 7060A1022 400SC - Safety Cable Black Architectural Control System to consist of: o Portable (Booth) 1 7184A1532 P-TS7-PE - Paradigm 7" Ethernet Portable Touchscreen Station to include: - 7" Black Portable Touchscreen - 10' Ethercon to RJ-45 cable 1 SGM76 25' Network Cable (Cat 5, Neutrik Ethercon to RJ45) o Entry Station (Replace as existing) 4 QUOTE-20005 UH10002-_Z - Standard Color (Color TBD) 1-gang faceplate assembly to include the following: 2 - Select Switch Standard nomenclature as On, Off, LED back light shall be illuminated Green when preset is in the Off state 4 7181B2004 UH10002 - 1-gang, 1-button electronics assembly w/IR Port 4 7081A2004-1 SBB1 - Unison 1-gang surface-mounted back box o LCD (SMP) 1 7184A1501-4 P-TS7-4 - Paradigm 7" Touchscreen Station to include: - 7" Black Touchscreen Assembly - Mounting Collar - LinkConnect/ Ethernet termination kit 1 7184A1503 P-LCD-SBB - Paradigm surface mount touchscreen back box Accessories 1 Portable Uninterruptable Power Supply capable of powering existing control console and monitors for up to 1-hour. - Install in booth for existing control console 1 Low Voltage control cable as necessary for all DMX, Paradigm and Network System(s) - Provide and terminate as necessary -Installation by the Electrical Contractor Option 1 1 4250A1022 NET3-RFR - Net3 Radio Focus Remote Universal Frequency to Include: 1 - Base Station with: 1 - USB Port to connect to Console 1 - Ethercon Ethernet Port to connect to Lighting Network 1 - Hand Held Transmitter with: 1 - 24 button Backlit keypad 2 - Encoder wheels 1 - Mini USB port for Recharging Battery 1 - ON/Off Switch 1 - USB A to B Cable 1 - USB A to Mini B Cable Wall-Wart Power Supply Belt Clip End BOM UNDER BASE BID PART 1. GENERAL INSERT THE FOLLOWING AFTER SECTION 2.16, F.1 2.17 ColorSource PAR Wash fixture A. General 1. The fixture shall be a color-mixing high-intensity LED illuminator with DMX control of intensity and color. The fixture shall be a ColorSource Par as manufactured by Electronic Theatre Controls, Inc. or approved equal. 2. All LED fixtures shall be provided by a single manufacturer to ensure compatibility 3. The fixture shall be UL 1573 listed for stage and studio use 4. The fixture shall comply with the USITT DMX-512 A standard B. Physical 1. The fixture shall be contained in a rugged all-metal die-cast housing, free of burrs and pits 2. The housing shall have a rugged black powdercoat finish a. White or silver/gray powdercoat finishes shall be available as color options b. Other powdercoat color options shall be available on request 3. Power supply, cooling and electronics shall be integral to each unit. 4. Fixture housing shall provide two easy-access slots for secondary lenses and other accessories a. Slots shall be equipped with locking retaining clip 5. The unit shall ship with a. Theatrical-style hanging yoke as standard b. 5' power lead with Edison connector as standard 6. Available options shall include but not be limited to: a. Floor stand conversion Kit b. Bare-end, Stage-Pin or Twist-lock type-equipped power leads c. PowerCon to PowerCon cables for fixture power linking d. Multiple secondary lens options to include multiple angles in the following patterns: 1. Linear 2. Round 3. Oblong 7. Light output shall be via a round aperture a. Aperture and accessory slots shall accommodate standard 7.5" accessories such as used in other similar-sized fixtures b. Accessories available as options shall include but not be limited to: 1. Gel/diffusion frames 2. Top hats 3. Barndoors 4. Egg crate louvers 5. Concentric ring louvers 6. Multiple secondary lensing options C. ENVIRONMENTAL AND AGENCY COMPLIANCE 1. The fixture shall be UL and cUL LISTED and/or CE rated, and shall be so labeled when delivered to the job site. 2. The fixture shall be UL LISTED to the UL1573 standard for stage and studio use 3. The fixture shall be rated for IP-20 dry location use. D. THERMAL 1. The fixture shall be cooled with a variable speed fan. 2. The fixture shall utilize advanced thermal management systems to maintain LED life to an average of 70% intensity after 20,000 hours of use a. Thermal management shall include multiple temperature sensors within the housing to include: 1. The LED array 2. The control board 3. The fixture shall operate in an ambient temperature range of 0°C (32°F) minimum, to 40° C (104°F) maximum ambient temperature. E. ELECTRICAL 1. The fixture shall be equipped with 100V to 240V 50/60 Hz internal power supply 2. The fixture shall support power in and thru operation a. Power in shall be via Neutrik® PowerCon™ input connector b. Power thru shall be via Neutrik ® PowerCon ™ output connector c. Fixture power wiring and accessory power cables shall be rated to support linking of multiple fixtures up to the capacity of a 15A breaker 3.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    30 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us