User Manual All Metal Detector

User Manual All Metal Detector

User Manual Combo of Metal Detector & Check Weigher Model:CMC Series Notes:Please read this manual carefully before using the machine and keep it for later reference. Please read chapters about Safe Instructions of this manual carefully before operating the machine. Baumann CMC Series Table Contents Basic Operations Ⅰ. Metal Detector part operations 1. Language Options……………………………………………………………………4 2. Metal Detecting………………………………………………………………………6 3. Performance Testing………………………………………………………… …… 8 4. Product Study………………………………… ………………………… ……… …10 5. Log……………………………………………………………………………………… 12 6. Product Default Settings……………………… ………………………………… 14 7. Product Edit……………………… …………………………………………………16 8. Rejecting Settings…………………………………………………………… … …19 9. Function Options……………………………………………………………………21 10. Clock……………………………………………………………………………………23 11. Touchscreen…………………………………………………………………………25 12. Password………………………………………………………………………………28 13. System Information…………………………………………………………………31 Ⅱ. Check Weigher part operations 1. Language selection…………………………………………………………………33 2. Weight Calibration…………………………………………………………………34 3. Sorting Config………………………………………………………………………36 4. Optimization…………………………………………………………………………38 5. Balance…………………………………………………………………………………40 1 6. Product editing………………………………………………………………………41 7. Weight sorting………………………………………………………………………43 8. Report output…………………………………………………………………………45 9. Function config………………………………………………………………………46 10. Time setup……………………………………………………………………………48 11. Touch screen calibration…………………………………………………………50 12. Password changing…………………………………………………………………52 Ⅲ. Contact information……………………………………………………..………55 Ⅳ. Maintenance…………………………………………………………..………………56 2 Baumann CMC Series Safe Instructions Attention: Before operating this machine, please carefully read this instruction so as to avoid possible damage. This instruction should be well saved. To operate this machine safely and conveniently, the rules specified as below should be followed: ! Don not use this machine in dangerous areas. ! Confirm the marked voltage value to be the same as local voltage value. — The only way to cut off electricity of this machine is to pull the plug. — Only can the accessories and options specially designed for this type by Bofeng Electronics Company be used. — Keep the transformer and display control unit away from liquid. — Do not let liquid soak into the display when cleaning it. Only use wet cotton fabric to clean the monitor. 3 Baumann CMC Series Language Options 1. Language Options 1.1 Operating Steps: Startup Language Options 1.2 Interface Indication: Startup screen. System initialization . 4 Baumann CMC Series Language Options Click here Click here to choose to choose Chinese. English. 1.3 Operating Guidance: Please click language choice box on touch screen. 1.4 Function Descriptions: System offers two operating language options to users: Chinese and English. If one of them is chosen, the following whole system operating processes will take it as operating language. The language of printer report will be in accordance with the chosen operating language. 5 Baumann CMC Series Metal Detecting 2. Metal Detecting 2.1 Operating Steps: Function Options Metal Detecting 2.2 Screen Instructions: Click this icon to enter ‘Metal Detecting’ function screen. The product name can be set by product edit Display current signal, signal range: 0.0%-99.9%. This screen offers some choice button boxes of common function. Click different function choice buttons to enter different functions. Click Exit button to enter main function screen. 6 Baumann CMC Series Metal Detecting 2.3 Operating guidance: Please click metal detecting icon on touch [Function Options] screen. On the screen please click ‘Start’ to start metal detecting. 2.4 Function Descriptions: Product name: The product name of metal to be tested. Sensitivity: Set by users. The higher sensitivity, the smaller metal will be tested. Detecting amount: All products’ amount of detected metal by current product name. 2.5 Notes: Current signal level should be refreshed in real time. Alarm when signal level reaches or exceeds 50% which means metal content of detected materials is over limit. 7 Baumann CMC Series Performance Testing 3. Performance Testing 3.1 Operating steps: Function Options Function Options 3.2 Screen instructions: Click this icon to enter ‘Testing’ functional screen Perform interference testing for ambient environment. Check if there are any foreign metal materials on conveyor belt. Click Start button to process testing orderly. 8 Baumann CMC Series Performance Testing 3.3 Operating guidance: Click performance testing icon on [Function options] screen to enter the function. Click ‘Start’ on the screen to perform machine performance testing. 3.4 Function Descriptions: This function is designed to detect if there is strong magnetic interference in ambient environment and foreign metal materials on conveyor belt. 3.5 Notes: When using the machine for first time in this function, user needs to perform performance testing. During the testing process man-made and exterior interferences are not permitted. If the testing can not be passed user is not able to perform metal detecting by this machine. 9 Baumann CMC Series Product Study 4. Product Study 4.1. Operating processes: Function Options Product Study 4.2 Screen Indication: Click this icon to enter ‘Product study’ functional screen Through self study system can save product characteristics After study click OK button to perform product characteristics storage 10 Baumann CMC Series Product Study 4.3. Operating guidance: Click product study icon on [Function options] screen to enter this function. Click ‘Start’ on the screen to start product self study. 4.4 Function Description: After starting the product self study function perform product self study for product under test according to different directions. If the same direction of product is put in self study the maximum sensitivity will be gained. But during the product detecting user also needs to put the same direction of product in metal detecting. 4.5 Notes: During the study of the product user should avoid large metal or magnetic material moving around. User should not knock the detector by hand or object. 11 Baumann CMC Series Log 5. Log 5.1 Operating steps: Function Options Log 5.2 Screen indication: Click this icon to enter ‘Log’ function screen. All detected product amount. Print function optional button. 12 Baumann CMC Series Log 5.3 Operating guidance: Click the log icon on [Function options] screen to enter the function. Click print current page on the screen and the current page log will be printed out by printing port. 5.4 Function descriptions: General log displays all products’ total and detailed log record. 5.5 Notes: Detailed log can only save 1000 pieces of recently detected records and the storage amount can be increased per user’s demand. 13 Baumann CMC Series Product Settings 6. Product Settings 6.1. Operating steps: Function Options Product settings 6.2 Screen indication: Click the icon to enter ‘Product default setting’ function screen. Choose relative product name according to user’s demand. 14 Baumann CMC Series Product Settings 6.3 Operating guidance: Please click the product default settings icon on touch [Function options] screen to enter [Product settings] screen. Click ‘OK’ will confirm and current user chooses the product name. 6.4 Function Description: Choose different product name according to detecting unused products. If there is no qualified product name on the screen, user can enter product edit screen to add new product. 6.5 Notes: After choosing the product please perform the product self study again if necessary. 15 Baumann CMC Series Product Edit 7. Product Edit 7.1 Operating steps: Function Options Product Edit 7.2 Screen indications: Click this icon to enter ‘ProductEdit’ function screen. Click the product name need to be edited. 16 Baumann CMC Series Product Edit 17 Baumann CMC Series Product Edit 7.3 Operating guidance: Please click product edit icon on LCD [Function menu] screen to enter product edit function screen. Click ‘Add’ on the screen to add a new product. Click ‘Delete’ to delete a product. Click ‘Modify’ to modify selected product. During operation user can operate according to status indication. 7.4 Notes: Sensitivity will be usually set at 85. It can also be set higher or lower but the product detection will be influenced. User must record a product name when deleting the product. After adding a new product user must enter product self study screen to perform product study once. Then user can use the product name to detect. Current maximum storage amount is 100 and it can be increased per user’s demand. 18 Baumann CMC Series Rejecting Settings 8. Rejecting Settings 8.1 Operating steps: Function Options Rejecting 8.2 Screen Indication: Settings Click this icon to enter ‘Rejecting Settings’function screen. Click up or down arrow to increase or decrease parameter values 19 Baumann CMC Series Rejecting Settings 8.3 Operating guidance: Please click the rejection icon on LCD [Function options] to enter deleting settings screen. 8.4 Function descriptions: Reject time: Rejector movement delay time and set delay time per user’s demand. Duration: Rejector movement duration time and set duration time per user’s demand. Rejected: It is the number of detected metal of the product. It can be reset to count from zero. 20 Baumann CMC Series Function Options 9. Function Options 9.1 Operating steps: Function Options Function Options 9.2 Screen indication:

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    60 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us