An Element for Your Success Unabhängige,Independent consultantsberatende and und planning planende engineers Ingenieure for water, waste water, solid waste and environmental für Wasser-, Abwassertechnologies-, Abfall- und Umwelttechnik Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt COD Determination Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt Quick COD (LAR) Measurement Method: • Thermal combustion at 1200°C which guarantees the complete oxidation of the sample without reagents. • Then measured with an NDIR detector Reliability: • High reliability – 98% availability Sensitivity: Measurement range: • 10-150 mg/l COD • 100-2,000 mg/l COD • 500-5,000 mg/l COD • 1,000-8,000 mg/l COD • 20,000-250,000 mg/l COD • More ranges on request Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt Quick COD (LAR) Calibration: • Not specified Performance: Feautures and accessories: • Catalyst-free technique • Reagent-free analysis • No filtration necessary • No memory effects • Very low maintenance and operational costs • Auto start option • Analyser available minimum 98% • Multi stream measurement (optional) • Monitors up to six streams Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt Quick COD (LAR) Equipment Configuration: • Designed for wall mounting, outdoors or indoors. Rail- and stand-mounting options are available. • weatherproof, and lockable. Dimensions • Width 700 x height 1,020 x depth 520 mm Weight • 115 kg (standard) Sample Volume: 10-600 microliter small Sample Preparation • Maintenance- free particle cutter • Optional homogeniser for the continuous homogenisation of samples Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt Quick COD (LAR) Response Time: • 1-2 minutes Particle Tolerance: • Max. 0.8mm according to ISO 8245 Measurement interval • 1 – 3 minutes - depending on the application Reagent Consumption • Only distilled water and a small amount of inexpensive acid required Reagent consumption: • No reagent Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt CAA- Continuous Auto Analyzer (PAI) Measurement Method: • Real continuous automatic monitoring of a wide range of parameters in liquid sample using these analytical techniques: • Potentiometry • Conductivity • Photometry • Fluorimetry Reliability: • Not specified Sensitivity: • not specified. Calibration • Manual/automatic (optional) Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt CAA- Continuous Auto Analyzer (PAI) Performance: Feautures and accessories: Accessories • Not specified Special features • Contrary to other techniques which analyze different samples, analyse the same sample continuously. • Cacluation of contaminant loads even if rapid changes in concentration may occur. Sample Condition: • Pressure: 0 bar with sample pump. Higher pressures on demand • Flow rate: application dependant • Temperature: >0-50 º C (application dependant) Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt CAA- Continuous Auto Analyzer (PAI) Equipment configuration: • Layout of CAA for ethylone oyide in glycol/water mixtures Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt CAA- Continuous Auto Analyzer (PAI) Dimensions: • Housing: wall mounting, stainless steel and plastic • Width ±400 mm x depth: 270 mm x heigt: 910 mm • Weight: approximately 30 kg Information transfer: • Transmitting results to process control an analog output ( (0)4- 20 mA) is used. Equipment safety: • Two separated housings to protect the electronics from any hazardous vapour and liquids. Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt CAA- Continuous Auto Analyzer (PAI) Operation : Inbuilt toch screen for manual control of CAA analyser . • Results are displayed in numerical or graphical presentation Operation Notification and Failure: • System fault: in case of system failure the alarm contact is triggered. • Threshold alarm (optional): relays for threshold alarm are available. • Response Time: • Not specified Particle Tolerance: • Not specified Measurement interval • continuous Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt Liquiline System CA 80 (EH) Measurement Method: • Established COD dichromate method directly comparable to laboratory results. Reliability: ± 10 % according to potassium hydrogen phthalate test Sensitivity: • 10-5,000 mg/l COD • 40-20,000 mg/l COD Calibration • Automatic calibration and cleaning User-configurable measuring, cleaning and calibration intervals • Zero standard: 500 ml per month given a calibration interval of 48 h. (no dilution module) • Standard 1: approx. 90 ml per month given a calibration interval of 48 h (no dilution module) Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt Liquiline System CA 80 (EH) Calibration Interval: • 1 h to 90 days, depending on the application and ambient condition Performance: Features and accessories: Accessories – Kit CA8x/CAT860: wall mounting – Kit CA8x/CAT860: housing bottom – Kit CA8x: door with window – … Sample Characteristics: • Volume: 8 ml per measurement • Temperature: 4 to 40 °C (39 to 104 °F) • Consistency: Low solids content, aqueous, homogenized Measuring interval: • Continuous (approx. 55 min), adjustable 30 min to 24 h Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt Liquiline System CA 80 (EH) Equipment Safety: Electrical safety • According to EN/IEC 61010-1:2010, Class I equipment • Low voltage: overvoltage category II • For installations up to 2000 m (6500 ft) above MSL Information Transfer: • Not specified Particle Tolerance: • Not specified Detection Limit: • Not specified Ambient temperature range • 5 to 40 °C (41 to 104 °F) • Humidity 10 to 95%, not condensing Hannover ∙ Hannover Erfurt ∙ Oldenburg Bremen Erfurt Comparison LAR PAI EH +++ + +++ Reliability + ++ +++ Sensitivity +++ ++ ++ Performance .
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages15 Page
-
File Size-