Symptom: Water Is Leaking from the Iron Like a Shower: S Range Only (S3, S4, I-S5, I-S6) s7

Symptom: Water Is Leaking from the Iron Like a Shower: S Range Only (S3, S4, I-S5, I-S6) s7

<p> Bureau Technique</p><p>TECHNICAL Instruction 9650-0004 V4</p><p>First G1 (731), Steamax G2 (735), Steamup (745), Steamup i- G5 (740), Evolution G4 (746), Evolution i-G5 (741), Premium Product involved: S3 (760), Magic S4 (755), Magic i-S5 (750), Magic i-S6 (765), LauraStar X1 (766) 498.0008.750 iron for i-S5 230V/800W 497.0008.750 Cliick iron for i-S5 230V/800W 498.0608.750 iron for i-S5 120V/600W 497.0001.755 iron for S4-S3 230V/800W 496.0001.755 iron (OM 2008) for S4-S3 230V/800W 498.0601.755 iron for S4-S3 120V/600W Page: 8 498.0008.740 iron for i-G5 230V/800W 497.0008.740 Cliick iron for i-G5 230V/800W Items involved: 498.0608.740 iron for i-G5 120V/600W 497.0001.745 iron for G4 230V/800W 496.0001.745 iron (OM 2008) for G4 230V/800W 498.0601.745 iron for G4 120V/600W 497.0001.735 iron for G2 230V/800W 497.0001.731 iron for G1 230V/800W 498.0008.765 Liight iron for i-S6 and X1 230V/800W 120.0030.750 Water reservoir S range New items: none Part: iron Valid since appliance All appliance are involved Date: 26.05.2008 number: What to do when an iron makes a big jet of steam or Subject: is spitting drops of water Specific Tools: none Informative only</p><p>TO AVOID ELECTRICAL SHOCK, SWITCH THE ON/OFF SWITCH TO OFF AND PULL THE PLUG FROM RECEPTACLE BEFORE PERFORMING ANY SERVICE OR MAINTENANCE</p><p>PRESSURE MUST BE DRAIN AWAY BEFORE PERFORMING ANY MAINTENANCE ON BOILERS</p><p>1 Bureau Technique</p><p>Symptoms: what to do?</p><p>Symptom: water is leaking from the iron like a shower: S range only (S3, S4, i-S5, i-S6) and X1: </p><p>The customer is complaining because some water leaks from the iron like a shower even if he had rinsed regularly the generator as shown in the owner manual. The trouble happens only when the machine is switched off for a long period (more than ~8 hours) and he is re-used for a new ironing session. When the generator is ready (green light is on, indicating that the steam is ready), the customer activates the steam function for the first time and water leaks from the iron.</p><p>The problem disappears completely after several long jets of steam.</p><p>Leaks of water</p><p>Example of a big jet of steam associated with a leak of water like a shower</p><p>2 Bureau Technique</p><p> The water level in the boiler is too high (boiler must be filled with only 0.4liter of water). Trouble is coming from a leakage of the boiler due a bad waterproof of the tube of the self priming system when bonded at the bottom of the water reservoir. o Check the water reservoir: if there is a leak coming from the fitting as shown at the picture (please, see below), replace it by a new one (120.0030.750). o Drain away the pressure inside the boiler and rinse the boiler 2x with warm tap water only. Then, check the appliance before send it back to the customer.</p><p>Water leaks from the fitting between the self priming system of the pump and water reservoir</p><p>3 Bureau Technique</p><p>Symptom: big jet of steam (sometimes dirty)</p><p> The boiler is full of deposit and water is saturated of impurity (salt and/or mud) o Rinse 2x the boiler with warm tap water only</p><p> Temperature of the soleplate is too low o 1st Check power supply of the iron (wiring from generator to iron) o 2nd Or change iron’s thermostat</p><p>Example of a big jet of steam</p><p>Symptom: the iron is spitting drops of water (some small drops of water on clothes/cover)</p><p> Temperature of the soleplate is too low o 1st Check power supply of the iron (wiring from generator to iron) o 2nd Or change iron’s thermostat</p><p> Temperature of the soleplate is OK: the anti-calefaction layer inside the soleplate is damaged and out of order o Change the soleplate</p><p>Example of some drops of water on clothes/cover</p><p>4 Bureau Technique</p><p>Soleplate’s heating control to be measured when the iron control lever is on MIN, oo, ooo or Max position:</p><p>MIN: 130 to 150°C (266 to 302°F) oo 150 to 170°C (302 to 338°F) ooo 180 to 200°C (356 to 392°F) MAX 200 to 220°C (356 to 428°F)</p><p>Temperature measurement can be done with a “K” probe as shown:</p><p>5 Bureau Technique</p><p>Process for Premium S3 (760), Magic S4 (755), Magic i-S5 (760), Magic i-S6 (765), LauraStar X1 (766), Steamup G4 (745), Steamup i-G5 (740), Evolution G4 (746), Evolution i-G5 (741), First G1 (731), Steamax G2 (735) </p><p>A. Switch the appliance OFF.</p><p>B. For S3, S4, i-S5, i-S6 and X1 only: check the water reservoir. Does the reservoir have a leakage as shown in page 3? If yes, replace it by a new one (120.0030.750).</p><p>C. Rinse 2x the boiler with tap water only. Appliance must be cold before start to proceed.</p><p>D. Replace the drain cap and switch the appliance ON</p><p>E. Wait until appliance is ready and check if the iron is still spitting or doing drops of water. Does the problem have been solved? 1) If yes, problem is resolved and after a complete final checking, appliance can be send back to customer. 2) If no, check the temperature of the soleplate. </p><p>Soleplate’s temperature checking</p><p> i. If temperature is to low (or soleplate is cold), check if there is a disconnected wire along the wiring from generator to the 4 positions terminal block (425.0000.703) inside the iron. If the wiring is OK, change the iron thermostat (401.0000.750) Thermostat 0- 240°C.</p><p>6 Bureau Technique</p><p>What to do when the temperature of the soleplate is too low? 1) Check the plug of the iron inside the generator 2) Connectors must be together</p><p>3) Open the iron as shown 4) Check if the wires are well connected</p><p>If the connectors inside the generator and the wires on the 4 positions terminal block have been controlled but the soleplate still remains cold, change the iron’s thermostat Thermostat (401.0000.750) on soleplate Removing/substitution of the thermostat</p><p>3) If some spitting/drops of water after having check the wiring and changed thermostat are remaining, it means that the anti-calefaction layer inside the steam passage of the soleplate is damaged and can’t be repaired. In that case, it is possible to exchange the soleplate only or if required, to replace the complete iron by a new one. </p><p>F. After having exchanged the soleplate/iron, make a complete final checking of the appliance before to send it back to the customer.</p><p>7 Bureau Technique</p><p>Spare parts & article number</p><p>Water reservoir for S range 120.0030.750 Water reservoir S</p><p>Iron’s thermostat 401.0000.750 thermostat 0-240°C</p><p>Beta soleplates: 466.0000.765 Beta LIIGHT soleplate 800W 230V/50Hz 466.0600.765 Beta LIIGHT soleplate 600W 120V/60Hz 402.0000.750 Beta soleplate 800W 230V/50Hz 402.0600.750 Beta soleplate 600W 120V/60Hz</p><p>Beta irons: 498.0008.750 iron for i-S5 230V/800W 497.0008.750 Cliick iron for i-S5 230V/800W 498.0608.750 iron for i-S5 120V/600W 497.0001.755 iron for S4-S3 230V/800W 496.0001.755 iron (OM 2008) for S4-S3 230V/800W 498.0601.755 iron for S4-S3 120V/600W 498.0008.740 iron for i-G5 230V/800W 497.0008.740 Cliick iron for i-G5 230V/800W 498.0608.740 iron for i-G5 120V/600W 497.0001.745 iron for G4 230V/800W 496.0001.745 iron (OM 2008) for G4 230V/800W 498.0601.745 iron for G4 120V/600W 497.0001.735 iron for G2 230V/800W 497.0001.731 iron for G1 230V/800W 498.0008.765 Liight iron for i-S6 and X1 230V/800W</p><p>8</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    8 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us