<p> NIGEL FORRESTER MCIOB ACCREDITED ENERGY ASSESSOR</p><p>SAP Energy Rating Survey Checklist</p><p>To complete a SAP calculation I need a set of building plans including floor plans, elevations, and sections and also a site plan indicating the orientation of the building in relation to north. I also need information relating to the items listed below, some of which may already be on the plans in which case there is no need to fill in those sections. Some of the information you may not know at the design stage.</p><p>If in any doubt please telephone and we can talk through the details.</p><p>If the project is at the design stage please indicate your preferred construction details</p><p>Project Details Site address…………………………………………………………………………………………………. ……………………………………………………………………………………………………………… ……………………………………………………………………………Post code………………………. Contact details Your name ………………………………………………………………………………………………… Your address ……………………………………………………………………………………………….. ……………………………………………………………………………………………………………… ……………………………………………………………………………Post code………………………. Telephone number………………………………………………………………………………………….. E mail address……………………………………………………………………………………………….</p><p>1. Ground floor construction Including insulation type and thickness </p><p>2. Main external wall construction Including insulation type and thickness</p><p>Ilett House, Smithy Bank, Alton, Staffordshire, ST10 4AD 3. Secondary walls. e.g. - stud walls in habitable roof space - walls adjacent to attached garage</p><p>4. Roof construction Including insulation type and thickness (Please state whether flat or sloping ceiling)</p><p>5. Window frames (please tick appropriate boxes)</p><p>UPVC Timber Metal</p><p>If known please state manufacturers declared U Value</p><p>6. External doors </p><p>UPVC Timber Metal</p><p>If known please state manufacturers declared U Value </p><p>7. Glazing</p><p>Single Double Triple Argon filled </p><p>Low ‘E’ soft coat Low ‘E’ hard coat </p><p>Air gap - 6mm 12mm 16mm 24mm 28mm</p><p>8. Mechanical ventilation - if applicable please give details of any mechanical ventilation (excluding standard extract fans fitted in kitchen, bathrooms, WC’s and utilities etc. </p><p>9. Heating system Briefly describe main heating system e.g. boiler and cylinder, combi boiler, wall or floor</p><p>Ilett House, Smithy Bank, Alton, Staffordshire, ST10 4AD mounted. If known give exact details of boiler including manufacturer, model number and efficiency etc. </p><p>Fuel Type </p><p>Underfloor heating - Yes No</p><p>10. Secondary heating Briefly describe any secondary heating e.g. wood burning stove, gas fire etc. If known give exact details including manufacturer, model number and efficiency etc. </p><p>Fuel type</p><p>11. Hot water</p><p>Is the hot water produced by the central heating boiler Yes No </p><p>Cylinder details if applicable</p><p>Capacity (litres) Insulation thickness</p><p>12. Renewables</p><p>Please give details of any additional energy systems proposed e.g. Solar Panels, Photovoltaic Panels, Wind turbines, Heat Pumps etc.</p><p>Ilett House, Smithy Bank, Alton, Staffordshire, ST10 4AD</p>
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages3 Page
-
File Size-