Field Inspection Checklist

Field Inspection Checklist

<p> Residential Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments Climate Zone 3</p><p>Building ID: Date: Name of Evaluator(s): </p><p>Building Contact: Name: Phone: Email: </p><p>Building Name & Address: </p><p>Subdivision: Lot #: Conditioned Floor Area: ft 2</p><p>State: County: Jurisdiction: </p><p>Compliance Approach (check all that apply): Prescriptive Trade-Off Performance </p><p>Compliance Software Used: Green Building/Above-Code Program: </p><p>Building Type: 1- and 2-Family, Detached: Single Family Modular Townhouse</p><p>Multifamily: Apartment Condominium</p><p>Project Type: New Building Existing Building Addition Existing Building Renovation</p><p>IECC Verified Complies Comments/Assumptions Section # Foundation Inspection Code Value Value Y N N/O N/A 402.1.1 Slab edge insulation R-value. Unheated: R- [FO1]1 R-0 Unheated Heated: R-5 Heated 303.2, Slab edge insulation installed 402.2.8 per manufacturer’s instructions. [FO2]1 402.1.1 Slab edge insulation Heated: 2 ft. ft. [FO3]1 depth/length. 402.1.1 Basement wall exterior Continuous: R- [FO4]1 insulation R-value1. R-5 303.2 Basement wall exterior [FO5]1 insulation installed per manufacturer’s instructions. 402.2.7 Basement wall exterior 10 ft. or to ft. [FO6]1 insulation depth. basement floor 402.2.9 Crawl space wall insulation Continuous: [FO7]1 R-value. R-5 R- Cavity: R-13 R- 303.2 Crawl space wall insulation [FO8]1 installed per manufacturer’s instructions. 402.2.9 Crawl space continuous vapor [FO9]1 retarder installed with joints overlapped by 6” and sealed, and extending at least 6” up the stem wall. 303.2.1 Exposed foundation insulation [FO10]2 protection. 403.8 Snow melt controls. [FO11]2</p><p>Additional Comments/Assumptions: </p><p>1 Basement insulation is not required in warm-humid locations. 10/29/2010 Page 1 General building information only required if different than above Building ID: </p><p>Date: Name of Evaluator(s): </p><p>Building Name & Address: Conditioned Floor Area: ft 2</p><p>Building Contact: Name: Phone: Email: </p><p>Compliance Approach (check all that apply): Prescriptive Trade-Off Performance </p><p>Compliance Software Used: Green Building/Above-Code Program: </p><p>IECC Code Verified Complies Comments/Assumptions Section # Framing / Rough-In Inspection Value Value Y N N/O N/A 402.1.1, Door U-factor. 2 U-0.50 U- 402.3.4 [FR1]1 402.1.1, Glazing U-factor (area-weighted U-0.50 U- 402.3.1, average). 3 Impact Rated: 402.3.3, 402.5 U-0.65 [FR2]1 402.1.1, Glazing SHGC value, including SHGC: 0.30 SHGC: 402.3.2, sunrooms (area-weighted (0.50 max)4 402.3.3 average). 4 [FR3]1 303.1.3 Glazing labeled for U-factor (or [FR4]1 default values used). 402.1.1, Skylight U-factor. 4 U-0.65 U- 402.3.3, 402.5 [FR5]1 402.1.1, Skylight SHGC value.4 SHGC: 0.30 SHGC: 402.3.3 (0.50 max)5 [FR6]1 303.1.3 Skylights labeled for U-factor (or [FR7]1 default values used). 402.3.5 Sunroom glazing U-factor. U-0.50 U- [FR8]1 Impact Rated: U-0.65 402.3.5 Sunroom skylight U-factor. U-0.65 U- [FR9]1 402.1.1 Mass wall exterior insulation R- R-55 R- [FR10]1 value. 303.2 Mass wall exterior insulation [FR11]1 installed per manufacturer’s instructions. 403.2.1 Duct insulation outside of building Attic Supply: R- [FR12]1 thermal envelope R-8 Other: R- R-6 403.2.4 Ducts sealed with mastic.. [FR13]1 403.2.3 Building cavities NOT used for [FR15]1 supply or return ducts. 402.4.5 Air-tight IC-rated recessed lighting [FR16]2 fixtures meet infiltration criteria. 403.3 HVAC piping insulation. R-3 R- [FR17]2</p><p>2 One side-hinged door up to 24 ft2 can be exempted from the prescriptive door U-factor requirements. Exemption cannot be applied to attic access. 3 Up to 15 ft2 of glazed fenestration, including skylights, may be exempted from U-factor and SHGC requirements under the prescriptive approach. 4 SHGC mandatory maximum using trade-offs. 5 If more than ½ the insulation is on the interior, mass wall interior insulation requirement applies (R-8). 10/29/2010 Page 2 403.4 Circulating hot-water piping R-2 R- [FR18]2 insulation. 403.5 Dampers installed on all outdoor [FR19]2 intake and exhaust openings. 402.4.4 Glazed fenestration air leakage. 0.3 cfm/ft2 [FR20]3 cfm/ ft2</p><p>402.4.4 Swinging door air leakage. 0.5 cfm/ft2 [FR21]3 cfm/ ft2 402.4.4 Fenestration and doors labeled for [FR22]3 air leakage. </p><p>Additional Comments/Assumptions: </p><p>10/29/2010 Page 3 General building information only required if different than above Building ID: </p><p>Date: Name of Evaluator(s): </p><p>Building Name & Address: Conditioned Floor Area: ft 2</p><p>Building Contact: Name: Phone: Email: </p><p>Compliance Approach (check all that apply): Prescriptive Trade-Off Performance </p><p>Compliance Software Used: Green Building/Above-Code Program: </p><p>IECC Code Verified Complies Comments/Assumptions Section # Insulation Inspection Value Value Y N N/O N/A 402.1.1, Floor insulation R-value. Wood: R- 402.2.5, R-19 Wood 6 402.2.6 Steel: Steel [IN1]1 See footnote 303.2, Floor insulation installed per 402.2.6 manufacturer’s instructions, and in [IN2]1 permanent continuous contact with the underside of the subfloor decking. 402.1.1 Wall insulation R-value. Wood: R- 402.2.5 R-13 Wood 7 402.2.4 Mass: Mass 1 [IN3] R-8 Steel Steel:8 See footnote 303.2 Wall insulation installed per [IN4]1 manufacturer’s instructions. 402.1.1 Basement wall interior insulation R- Continuous: [IN5]1 value. R-5 R- Cavity: R-13 R- 303.2 Basement wall interior insulation [IN6]1 installed per manufacturer’s Instructions. 402.2.7 Basement wall interior insulation 10 ft or to ft [IN7]1 depth. basement floor 402.2.11 Sunroom wall insulation R-value. R-13 R- [IN8]1 303.2 Sunroom wall insulation installed per [IN9]1 manufacturer’s Instructions. 402.2.11 Sunroom ceiling insulation R-value. R-19 R- [IN10]1 303.2 Sunroom ceiling insulation installed [IN11]1 per manufacturer’s instructions. 303.1 All installed insulation labeled or [IN13]2 installed R-value provided. 402.4.1, Air sealing of all openings and 402.4.2 penetrations: [IN14]3  Site-built fenestration  Window/door openings  Utility penetrations  Attic access openings</p><p>6 Floor steel frame equivalent: R-19+R-6 in 2x6 or R-19+R-12 in 2x8 or 2x10 7 If more than ½ the insulation is on the exterior, mass wall exterior insulation requirement applies (R-5). 8 Wall steel frame equivalent: R-13+R-5; R-15+R-4; R-21+R-3; R-0+R-10 10/29/2010 Page 4 402.4.1, Air sealing of all envelope joints and 402.4.2 seams: [IN15]3  Dropped ceilings  Knee walls  Assemblies separating garage  Tubs and showers  Common walls between units  Rim joist junctions</p><p>402.4.1, Air sealing of all other sources of 402.4.2 infiltration, including air barrier.. [IN16]3</p><p>Additional Comments/Assumptions: </p><p>10/29/2010 Page 5 General building information only required if different than above Building ID: </p><p>Date: Name of Evaluator(s): </p><p>Building Name & Address: Conditioned Floor Area: ft 2</p><p>Building Contact: Name: Phone: Email: </p><p>Compliance Approach (check all that apply): Prescriptive Trade-Off Performance </p><p>Compliance Software Used: Green Building/Above-Code Program: </p><p>IECC Verified Complied Comments/Assumptions Section # Final Inspection Provisions Code Value Value Y N N/O N/A 402.1.1, Ceiling insulation R-value. Wood: R- 402.2.1, R-30 Wood 9 402.2.2 Steel Truss Steel [FI1]1 Steel Joist10 303.1.1.1, Ceiling insulation installed per 303.2 manufacturer’s instructions. [FI2]1 Blown insulation marked every 300 ft2. 402.2.3 Access hatch and door insulation Hole cover: R- [FI3]1 and weatherstripping. R-19 Vertical doors/stairs: R-5 402.1.1 Attic kneewall insulation R-value R-18 R- [FI13ga] 1 with attic-side air barrier. 402.2.1.1 Wind wash baffle and dam for air- [FI14ga] 1 permeable insulation. 403.2.2 Duct tightness test complies with Rough-in Total % [FI4]1 thresholds. Results posted on Leakage, RIT: 6% compliance certificate. If all ducts Post- and equipment inside envelope, construction test not required and noted on Total Leakage, certificate. PCT: 12 % Post- Construction Leakage to Outdoors, PCO: 8 % 403.6 Heating and cooling equipment [FI5]1 type and efficiency on compliance certificate. </p><p>. 403.6.1 Electric-resistance heat NOT [FI15ga] 1 used as the primary heat source. 404.1 Lighting - 50% of lamps are high [FI6]1 efficacy or controlled via an occupancy or vacancy sensor. 402.4.2, Envelope tightness complies with ACH 50 < 7 ACH 50 = 402.4.2.1 sealing requirements via blower [IN12]1 door test. Results posted on compliance certificate. If multifamily (R-2 occupancy), verification via visual inspection instead of blower door test is allowed. 401.3 Compliance certificate posted at [FI7]2 electrical panel or air handler. 403.6 HVAC loads calculations and air kBtu: </p><p>9 Steel truss equivalent: R-38; R-30+R-3; R-26+R-5. 10 Steel joist equivalent: R-38 in 2x4 or 2x6 or 2x8; R-49 in any framing. 10/29/2010 Page 6 [PR2]2 handler cfm on compliance certificate: kBtu: Heating system size(s): Cooling system size(s): cfm:</p><p>402.4.3 Site built masonry wood burning [FI8]2 fireplace - gasketed doors and outdoor air for combustion. 403.1.1 Programmable thermostats [FI9]2 installed on forced air furnaces. 403..1.2 Heat pump thermostat or lockout [FI10]2 device installed on heat pumps. 403.4 Circulating hot water systems [FI11]2 have automatic or accessible manual controls. 403.9 Pool heaters, covers, and [FI12]2 automatic or accessible manual controls. 403.10 Power attic ventilators NOT [FI16ga]2 connected to the electric grid.</p><p>Additional Comments/Assumptions: </p><p>KEY 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)</p><p>10/29/2010 Page 7</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    7 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us