Table 4: Sample Preparation, Instrumental Analysis, Validation Parameters and Application

Table 4: Sample Preparation, Instrumental Analysis, Validation Parameters and Application

<p>Table S4: Sample preparation, instrumental analysis, validation parameters and application of sent standard mixture for laboratory coded 4 </p><p>COMPOUND SAMPLE PREP INTRUM ANALYSIS VALIDATION PARAM Application of sent mixture Sample preparation Instrumental analysis Validation parameters a. Standard mixture was used for calibration (sample pre-treatment: pH adjustment, filter (operational parameters: (sensitivity, accuracy, pore size, material and trade name, extraction separation and detection recovery, reproducibility, b. Standard mixture was used method and conditions, additional clean-up, condition,…) repeatability,…) for check-up derivatisation, internal standard c.Standard mixture was not used</p><p>…) CP 1º) Filtration through 0.45 µm nylon membranes - Analysis by UPLC-MS/MS - Quantification by the Standard mixture was used for - Equipment: UPLC system isotope dilution method with calibration 2º) Addition of EDTA 0.1 M (Waters Corp.Milford, MA, calibration curves prepared USA) equipped with a binary in HPLC-water 3º) Concentration of water sample by SPE using solvent system (Milford, MA, - Linearity: 0.10–80 ng mL-1 the automatic extractor ASPECTM GX-271 USA) and a sample - Sensitivity: method limit of (Gilson, Villiers le Bel, France): sample volume, manager.UPLC coupled with quantification (s/n 10) = 3.6 ng L-1 in wastewater. 50 mL; cartridge, HLB Oasis cartridges a 5500QTRAP hybrid triple - Accuracy: relative recovery (200mg/6mL) from Waters. Washing with 5 mL quadrupole-linear ion trap mass spectrometer equipped (calculated with respect to of HPLC-water with a Turbo Ion Spray the IS, 100, 500, and 1,000 source from Applied ng L-1, n=5) = 73-96 %. 4º) After the elution with methanol, extracts Biosystems-Sciex (Foster - Repeatability: relative were evaporated to dryness City, California, USA). standard deviation (RSD, in - LC separation on a reversed- wastewater, spiking levels 5º) Reconstitution of the extract to 0.5mL of phase column Acquity HSS 100, 500, and -1 methanol–water (10:90, v/v). T3 column ( 50 mm×2,1 mm 1,000 ng L , n=5) = 1.3 %. </p><p>-1 i.d. 1,7 μm particle size; 6º) 5 μL of Internal standard (10 ng μL ) was Waters Corp. Milford, MA, added: Cyclophosphamide isotopically labelled USA) at flow rate of 0.4 mL min-1. The column was kept at 25 °. Ultrapure water 0.1 % formic acid (A) and acetonitrile (B), were employed as mobile phase (flow-rate 0.4 mL min-1). LC gradient : 0 min, 5 % of B: 0.1–4 min, 5-100% B; 4.0– 4.5 min, 100 % B; 4.5–5.0 min, 100–5 % B; 5.0 min, 5 % B during 0.5 min. Sample injection volume 5 μL - MS/MS conditions: positive ESI; SRM quantification transition, 261.1 > 140.0; SRM confirmation transition, 261.1 > 106.0; collision energy, 31 eV and 25 eV, respectively; declustering potential, 101 V.</p><p>ETO 1º) Filtration through 0.45 µm nylon membranes - Analysis by UPLC-MS/MS - Quantification by the Standard mixture was used for - Equipment: UPLC system isotope dilution method with calibration 2º) Addition of EDTA 0.1 M (Waters Corp.Milford, MA, calibration curves prepared USA) equipped with a binary in HPLC-water 3º) Concentration of water sample by SPE using solvent system (Milford, MA, - Linearity: 0.10–80 ng mL-1 the automatic extractor ASPECTM GX-271 USA) and a sample - Sensitivity: method limit of (Gilson, Villiers le Bel, France): sample volume, manager.UPLC coupled with quantification (s/n 10) = 80 ng L-1 in wastewater. 50 mL; cartridge, HLB Oasis cartridges a 5500QTRAP hybrid triple - Accuracy: relative recovery (200mg/6mL) from Waters. Washing with 5 mL quadrupole-linear ion trap mass spectrometer equipped (calculated with respect to of HPLC-water with a Turbo Ion Spray the IS, 100, 500, and 1,000 source from Applied ng L-1, n=5) = 47-73 %. 4º) After the elution with methanol, extracts Biosystems-Sciex (Foster - Repeatability: relative were evaporated to dryness City, California, USA). standard deviation (RSD, in - LC separation on a reversed- wastewater, spiking levels 5º) Reconstitution of the extract to 0.5mL of phase column Acquity HSS 100, 500, and -1 methanol–water (10:90, v/v). T3 column ( 50 mm×2,1 mm 1,000 ng L , n=5) = 10.9 %. </p><p>-1 i.d. 1,7 μm particle size; 6º) 5 μL of Internal standard (10 ng μL ) was Waters Corp. Milford, MA, added: Etoposide isotopically labelled USA) at flow rate of 0.4 mL min-1. The column was kept at 25 °. Ultrapure water 0.1 % formic acid (A) and acetonitrile (B), were employed as mobile phase (flow-rate 0.4 mL min-1). LC gradient : 0 min, 5 % of B: 0.1–4 min, 5-100% B; 4.0– 4.5 min, 100 % B; 4.5–5.0 min, 100–5 % B; 5.0 min, 5 % B during 0.5 min. Sample injection volume 5 μL - MS/MS conditions: positive ESI; SRM quantification transition, 589>185 collision energy, 75 eV; declustering potential, 56 V.</p><p>IF 1º) Filtration through 0.45 µm nylon membranes - Analysis by UPLC-MS/MS - Quantification by the Standard mixture was used for - Equipment: UPLC system isotope dilution method with calibration 2º) Addition of EDTA 0.1 M (Waters Corp.Milford, MA, calibration curves prepared USA) equipped with a binary in HPLC-water 3º) Concentration of water sample by SPE using solvent system (Milford, MA, - Linearity: 0.10–80 ng mL-1 the automatic extractor ASPECTM GX-271 USA) and a sample - Sensitivity: method limit of (Gilson, Villiers le Bel, France): sample volume, manager.UPLC coupled with quantification (s/n 10) = 5.8 ng L-1 in wastewater. 50 mL; cartridge, HLB Oasis cartridges a 5500QTRAP hybrid triple - Accuracy: relative recovery (200mg/6mL) from Waters. Washing with 5 mL quadrupole-linear ion trap mass spectrometer equipped (calculated with respect to of HPLC-water with a Turbo Ion Spray the IS, 100, 500, and 1,000 source from Applied ng L-1, n=5) = 74-90 %. 4º) After the elution with methanol, extracts Biosystems-Sciex (Foster - Repeatability: relative were evaporated to dryness City, California, USA). standard deviation (RSD, in - LC separation on a reversed- wastewater, spiking levels 5º) Reconstitution of the extract to 0.5mL of phase column Acquity HSS 100, 500, and -1 methanol–water (10:90, v/v). T3 column ( 50 mm×2,1 mm 1,000 ng L , n=5) = 3.7 %. </p><p>-1 i.d. 1,7 μm particle size; 6º) 5 μL of Internal standard (10 ng μL ) was Waters Corp. Milford, MA, added: Ifosfamide isotopically labelled USA) at flow rate of 0.4 mL min-1. The column was kept at 25 °. Ultrapure water 0.1 % formic acid (A) and acetonitrile (B), were employed as mobile phase (flow-rate 0.4 mL min-1). LC gradient : 0 min, 5 % of B: 0.1–4 min, 5-100% B; 4.0– 4.5 min, 100 % B; 4.5–5.0 min, 100–5 % B; 5.0 min, 5 % B during 0.5 min. Sample injection volume 5 μL - MS/MS conditions: positive ESI; SRM quantification transition, 261>154; SRM confirmation transition, 261 > 92; collision energy, 31 eV and 33 eV, respectively; declustering potential, 76 V.</p><p>MTX 1º) Filtration through 0.45 µm nylon membranes - Analysis by UPLC-MS/MS - Quantification by the Standard mixture was used for - Equipment: UPLC system isotope dilution method with calibration 2º) Addition of EDTA 0.1 M (Waters Corp.Milford, MA, calibration curves prepared USA) equipped with a binary in HPLC-water 3º) Concentration of water sample by SPE using solvent system (Milford, MA, - Linearity: 0.10–80 ng mL-1 the automatic extractor ASPECTM GX-271 USA) and a sample - Sensitivity: method limit of (Gilson, Villiers le Bel, France): sample volume, manager.UPLC coupled with quantification (s/n 10) = 5.9 ng L-1 in wastewater. 50 mL; cartridge, HLB Oasis cartridges a 5500QTRAP hybrid triple - Accuracy: relative recovery (200mg/6mL) from Waters. Washing with 5 mL quadrupole-linear ion trap mass spectrometer equipped (calculated with respect to of HPLC-water with a Turbo Ion Spray the IS, 100, 500, and 1,000 source from Applied ng L-1, n=5) = 82-87 %. 4º) After the elution with methanol, extracts Biosystems-Sciex (Foster - Repeatability: relative were evaporated to dryness City, California, USA). standard deviation (RSD, in - LC separation on a reversed- wastewater, spiking levels 5º) Reconstitution of the extract to 0.5mL of phase column Acquity HSS 100, 500, and -1 methanol–water (10:90, v/v). T3 column ( 50 mm×2,1 mm 1,000 ng L , n=5) = 3.0 %. </p><p>-1 i.d. 1,7 μm particle size; 6º) 5 μL of Internal standard (10 ng μL ) was Waters Corp. Milford, MA, added: Methotrexate isotopically labelled USA) at flow rate of 0.4 mL min-1. The column was kept at 25 °. Ultrapure water 0.1 % formic acid (A) and acetonitrile (B), were employed as mobile phase (flow-rate 0.4 mL min-1). LC gradient : 0 min, 5 % of B: 0.1–4 min, 5-100% B; 4.0– 4.5 min, 100 % B; 4.5–5.0 min, 100–5 % B; 5.0 min, 5 % B during 0.5 min. Sample injection volume 5 μL - MS/MS conditions: positive ESI; SRM quantification transition, 455>308; SRM confirmation transition, 455>175 ; collision energy, 27 eV and 57 eV, respectively; declustering potential, 131 V.</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    5 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us