![LSS Depthed Underground Services](https://data.docslib.org/img/3a60ab92a6e30910dab9bd827208bcff-1.webp)
<p> Transport Services Division GEOSPATIAL SERVICES Standards & Operational Procedures</p><p>LOCATING SEQUENTIAL STRINGS – Underground Services</p><p>CODE As Shown DESCRIPTION As Shown MODEL SERVICES * TINEABLE NO DIRECTIONAL NO LOCATION INFORMATION Located at natural surface with null level COMMENTS Text to be displayed in associated Services Model</p><p>Glossary of Code Service Standard Text Display Common Examples of Description Classifications DT DPTI ‘O/F’ (If relevant); ‘Description’; ‘D’; ‘Indicative depth’ (If O/F Optic Fibre O/F D 1.2m App Requested, to be suffixed by App [Approximate]) P/L Public Lighting T/S D S/L Street Lighting S/L D T/S Traffic Signal</p><p>EL ETSA ‘O/F’ (If relevant); ‘HV’ or’LV’; ‘Voltage’ (If HV); ‘E’; O/F Optic Fibre HV 11kv E 1.2 m App ‘Indicative depth’ (If requested, to be suffixed by App HV High Voltage HV E [Approximate]) LV Low Voltage LV E SL Street Lighting SL E (Council Owned) O/F E DEAD E</p><p>K-Net Doc: 5829403 UNCONTROLLED COPY WHEN PRINTED Version No.: 1 Issue Date: 28/09/2011 Doc. Owner: Sen. Surveyor Engineering Page 1 of 3 Transport Services Division GEOSPATIAL SERVICES Standards & Operational Procedures</p><p>Glossary of Code Service Standard Text Display Common Examples of Description Classifications Envestra 100 mm SP HPGM 2.8m GA Gas ‘Asset Owner’ (If not APA); ‘Diameter’; Classification; GM –Gas Main App ‘G’; ‘Indicative depth’ (If requested, to be suffixed by App HP – High Pressure 300mm HP SP G [Approximate]) LP – Low Pressure 40mm SP G SP – Steel Pipe 300mm HP SP G CI – Cast Iron MAIN G POLY – Polycarbonate 100mm CI G Tubing</p><p>RX Rail ‘O/F’ (If relevant); ‘HV’ or’LV’; ‘Voltage’ (If HV); ‘RX’; HV High Voltage HV 11kv RX 1.5m App ‘Indicative depth’ (If requested, to be suffixed by App LV Low Voltage LV RX [Approximate]) SE Sewer PVCU Poly Vinly Chloride ‘Diameter’; Classification; ‘S’; ‘Indicative depth’ 225mm CI S 1.2m App Unplasticised (If requested, to be suffixed by App [Approximate]) CL Concrete Lined 150mm PVCU S CI Cast Iron 400mm MSCL PUMP S PE Poly Etheline PUMP Pumping Main GRAV Gravity Main UNK Unknown </p><p>D* Stormwater ‘Diameter’; Classification; ‘SS’; ‘Indicative depth’ RC Reinforced Concrete 375mm RCP SS C* (If requested, to be suffixed by App [Approximate]) BC Box Culvert 375*225mm RCBC SS MS Mild Steel 450mm RCP SS CL Concrete Lined</p><p>K-Net Doc: 5829403 UNCONTROLLED COPY WHEN PRINTED Version No.: 1 Issue Date: 28/09/2011 Doc. Owner: Sen. Surveyor Engineering Page 2 of 3 Transport Services Division GEOSPATIAL SERVICES Standards & Operational Procedures</p><p>TE Comms ‘Asset Owner’; ‘O/F’ (If exists); ‘T’ O/F Optic Fibre TELSTRA O/F T OPTUS O/F T DEAD T OPTUS O/F NOT LOC AMCOM O/F T</p><p>Glossary of Code Service Standard Text Display Common Examples of Description Classifications WA Water ‘Diameter’; Classification; ‘W’; ‘Indicative depth’ CL Concrete Lined 375mm AC W 1.2m App (If requested, to be suffixed by App [Approximate]) AC Asbestos Cement 750mm MSCL W MS Mild Steel 375mm DICL W CI Cast Iron 150mm CICL W 200mm UNKNOWN W</p><p>WR Reclaimed ‘Diameter’; Classification; ‘RW’; ‘Indicative depth’ CL Concrete Lined 375mm MS RW Water (If requested, to be suffixed by App [Approximate]) MS Mild Steel</p><p>US Unknown ‘Diameter’; Classification; ‘U’; ‘Indicative depth’ 150mm CICL U (If requested, to be suffixed by App [Approximate])</p><p>K-Net Doc: 5829403 UNCONTROLLED COPY WHEN PRINTED Version No.: 1 Issue Date: 28/09/2011 Doc. Owner: Sen. Surveyor Engineering Page 3 of 3</p>
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages3 Page
-
File Size-