LSS Depthed Underground Services

Total Page:16

File Type:pdf, Size:1020Kb

LSS Depthed Underground Services

Transport Services Division GEOSPATIAL SERVICES Standards & Operational Procedures

LOCATING SEQUENTIAL STRINGS – Underground Services

CODE As Shown DESCRIPTION As Shown MODEL SERVICES * TINEABLE NO DIRECTIONAL NO LOCATION INFORMATION Located at natural surface with null level COMMENTS Text to be displayed in associated Services Model

Glossary of Code Service Standard Text Display Common Examples of Description Classifications DT DPTI ‘O/F’ (If relevant); ‘Description’; ‘D’; ‘Indicative depth’ (If O/F Optic Fibre O/F D 1.2m App Requested, to be suffixed by App [Approximate]) P/L Public Lighting T/S D S/L Street Lighting S/L D T/S Traffic Signal

EL ETSA ‘O/F’ (If relevant); ‘HV’ or’LV’; ‘Voltage’ (If HV); ‘E’; O/F Optic Fibre HV 11kv E 1.2 m App ‘Indicative depth’ (If requested, to be suffixed by App HV High Voltage HV E [Approximate]) LV Low Voltage LV E SL Street Lighting SL E (Council Owned) O/F E DEAD E

K-Net Doc: 5829403 UNCONTROLLED COPY WHEN PRINTED Version No.: 1 Issue Date: 28/09/2011 Doc. Owner: Sen. Surveyor Engineering Page 1 of 3 Transport Services Division GEOSPATIAL SERVICES Standards & Operational Procedures

Glossary of Code Service Standard Text Display Common Examples of Description Classifications Envestra 100 mm SP HPGM 2.8m GA Gas ‘Asset Owner’ (If not APA); ‘Diameter’; Classification; GM –Gas Main App ‘G’; ‘Indicative depth’ (If requested, to be suffixed by App HP – High Pressure 300mm HP SP G [Approximate]) LP – Low Pressure 40mm SP G SP – Steel Pipe 300mm HP SP G CI – Cast Iron MAIN G POLY – Polycarbonate 100mm CI G Tubing

RX Rail ‘O/F’ (If relevant); ‘HV’ or’LV’; ‘Voltage’ (If HV); ‘RX’; HV High Voltage HV 11kv RX 1.5m App ‘Indicative depth’ (If requested, to be suffixed by App LV Low Voltage LV RX [Approximate]) SE Sewer PVCU Poly Vinly Chloride ‘Diameter’; Classification; ‘S’; ‘Indicative depth’ 225mm CI S 1.2m App Unplasticised (If requested, to be suffixed by App [Approximate]) CL Concrete Lined 150mm PVCU S CI Cast Iron 400mm MSCL PUMP S PE Poly Etheline PUMP Pumping Main GRAV Gravity Main UNK Unknown

D* Stormwater ‘Diameter’; Classification; ‘SS’; ‘Indicative depth’ RC Reinforced Concrete 375mm RCP SS C* (If requested, to be suffixed by App [Approximate]) BC Box Culvert 375*225mm RCBC SS MS Mild Steel 450mm RCP SS CL Concrete Lined

K-Net Doc: 5829403 UNCONTROLLED COPY WHEN PRINTED Version No.: 1 Issue Date: 28/09/2011 Doc. Owner: Sen. Surveyor Engineering Page 2 of 3 Transport Services Division GEOSPATIAL SERVICES Standards & Operational Procedures

TE Comms ‘Asset Owner’; ‘O/F’ (If exists); ‘T’ O/F Optic Fibre TELSTRA O/F T OPTUS O/F T DEAD T OPTUS O/F NOT LOC AMCOM O/F T

Glossary of Code Service Standard Text Display Common Examples of Description Classifications WA Water ‘Diameter’; Classification; ‘W’; ‘Indicative depth’ CL Concrete Lined 375mm AC W 1.2m App (If requested, to be suffixed by App [Approximate]) AC Asbestos Cement 750mm MSCL W MS Mild Steel 375mm DICL W CI Cast Iron 150mm CICL W 200mm UNKNOWN W

WR Reclaimed ‘Diameter’; Classification; ‘RW’; ‘Indicative depth’ CL Concrete Lined 375mm MS RW Water (If requested, to be suffixed by App [Approximate]) MS Mild Steel

US Unknown ‘Diameter’; Classification; ‘U’; ‘Indicative depth’ 150mm CICL U (If requested, to be suffixed by App [Approximate])

K-Net Doc: 5829403 UNCONTROLLED COPY WHEN PRINTED Version No.: 1 Issue Date: 28/09/2011 Doc. Owner: Sen. Surveyor Engineering Page 3 of 3