Notice to Tenderers

Notice to Tenderers

<p> NOTICE TO TENDERERS</p><p>Tender number: DBN/CAP (RTPC) 641/2</p><p>SUPPLY & INSTALL 2MVA 11KV / 400V TRANSFORMERS FOR PARCELS Tenders invited for: SUBSTATIONS FOR METRORAIL KZN</p><p>With effect from ______2017 and ______2017 the tender document (CD) may be collected at:</p><p>Address: Metrorail Regional Office 65 Masabalala Yengwa Avenue Durban Station</p><p>Office hours: Mondays to Fridays 08:00 to 15:30 (ONLY) where CD’s can also be obtained on payment of an amount of R 500.00 per disc which is not refundable. No cash or cheques will be accepted at PRASA offices – (Bank Deposit or Electronic Payments - allow for 1-day delay). Clearly indicate the Tender Number on the Deposit Slip or EFT document as reference.</p><p>BANKING DETAILS:-</p><p>Metrorail KZN, Standard Bank, Windermere, Branch Code: 042726, Account No.: 050832948</p><p>Confirmation of EFT payment must be e-mailed to the Senior Buyer PRIOR to collecting the CD or attending the Briefing Session. Failing to do so will result in you not being granted access to the Briefing Session.</p><p> Tenderers must arrange own transport and parking.  Tenderers failing to attend the compulsory tender briefing session will be disqualified.  PRASA reserves the right to only allow tenderers in possession of a valid tender document at the briefing.  A maximum of two representatives per company will be allowed to attend the briefing.  Tender documents (CD’s) are only available during the period stipulated above.</p><p>THE ONUS IS ON THE TENDERER TO PRINT THE DOCUMENT FROM THE CD DISC AND SUBMIT PRINTED TENDER DOCUMENTS WHEN SUBMITTING THEIR TENDERS. </p><p>NB: IT IS MANDATORY REQUIREMENT FOR PROSPECTIVE SUPPLIERS TO BE REGISTERED ON THE CSD IN ALL REQUESTS FOR PROCUREMENT OF GOODS AND / OR SERVICES.</p><p>BID ADVERTISEMENT FORM SPECIFICATION</p><p>SUPPLY AND INSTALL 2MVA 11KV/400V TRANSFORMERS FOR PARCELS SUBSTATIONS</p><p>1. PROJECT PURPOSE</p><p>The purpose of this project is to supply and install TWO 2MVA, 11KV/400V indoor oil cooled transformers as per attached bill of quantity. </p><p>2. ADDITIONAL WORKS</p><p>Any additional work not authorized by the Project manager, even if proven necessary for the successful completion of the project, will be tenderer’s own account.</p><p>3. PENALTIES</p><p>3.1 The contractor will be charged a penalty of R200.00 per day delayed after the project duration has expired. 3.2 The contractor shall also be charged R10 000.00 if found on site without proper site access from Metrorail.</p><p>4. REQUIREMENTS</p><p>4.1 The contractor must provide a qualified Electrician or Technician with a minimum of 2 -3 years of experience on Medium Voltage Cable Termination and 11KV Transformer Installation. 4.2 The contractor must have a traceable reference of the similar work.</p><p>5. SAFETY REQUIREMENTS</p><p>All work in this contract shall comply with the Occupational Safety Act, 1993 (Act No 85 of 1993). These items shall all be included in tendered rate. A copy of the act as well as an approved safety file shall be kept on site for the duration of the project.</p><p>6. SECURITY </p><p>The contractor shall be responsible for providing security on site until site is handed over to Metrorail</p><p>7. CLEARING OF SITE </p><p>All rubble which is left over as a direct result of work performed by the contractor shall be removed from site and disposed by the contractor. The substation floors and walls shall be left in a clean condition. All cables, wires and conductors cut-offs and surplus material shall be removed from site to Durban Electrical depot. </p><p>8. CIDB GRADING </p><p>CIDB grading is 3 EP.</p><p>9. DURATION </p><p>The project duration is eight (8) months.</p><p>10. TRANSPORTATION OF SCRAP </p><p>The contractor shall transport old equipment to Durban Electrical Depot</p><p>11. STANDARDS </p><p>BID ADVERTISEMENT FORM The transformers must comply with SANS780 standards.</p><p>BID ADVERTISEMENT FORM 12. TECHNICAL DETAILS</p><p>12.1 Transformer rating: 2000KVA 12.2 Phase: 3 12.3 Vector symbol: Dyn11 12.4 Impedance voltage: 4.69 12.5 Frequency: 50Hz 12.6 Cooling: ONAN 12.7 Core and windings: 3330Kg 12.8 Oil capacity: 1490 liters 12.9 Primary side voltage: 11000V 12.10 Secondary side voltage: 400V 12.11 Primary side current: 105A 12.12 Secondary side current: 2887.5A 12.13 Tap changer: On load tap changer 12.14 Color: machinery grey 12.15 Neutral point: YES</p><p>END OF SPECIFICATION</p><p>______DATE SUPPLIER</p><p>BID ADVERTISEMENT FORM</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    4 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us