<p> Appendix EQ, Test Equipment Recommendations and Calibration</p><p>Appendix EQ Test Equipment Recommendations & Calibration a) Clothes Washer</p><p>Figure EQ-1, The Clothes Washer</p><p>Type: Fisher and Paykal top loading clothes washer Model: GWL 11 US Serial: UKN627345 Input Voltage: 110 ~ 120 V, 60 Hz, 7 Amps</p><p>Created by Phie Theng Lee 37 Michigan Technological University Appendix EQ, Test Equipment Recommendations and Calibration b) Clothes Dryer Type: Kenmore front loading clothes dryer Model: prototype Input Voltage: 220 ~ 240 V, 60 Hz</p><p>The following list contains the specifications and calibration factors of the test equipment. The calibration factors were verified using known sources and were calculated according to the following:</p><p>Calfac = Refval / Outvol in Engineering Units per Volt</p><p>Calfac Transducer sensitivity</p><p>Refval reference value of the calibration source</p><p>Outvol output voltage of the transducer c) Apparatus to use with Clothes Washer PCB Laser Tachometer Measurement Range up to 30,000 rpm with 1 pulse per revolution Operating Range 90 degree incidence (60 inches apart) 60 degree incidence (15 inches apart) Excitation Voltage 18 to 30 VDC Temperature Range 14 ~ 122 degree F Mounting Thread 5/8-18 UNF 2A Weight 0.85 oz</p><p>PCB Tri-axial accelerometer Model # 356A15, Serial # 33675, 33363 and 33664 Sensitivity 100 mV/g Measurement Range +/- 50 g peak Output Bias Voltage 8 ~ 12 VDC Frequency Range 2 ~ 5000 Hz +/- 5% or 1.4 ~ 6500 Hz +/- 10% Temperature Range -65 ~ 250 degree F Resonant Frequency >= 25 kHz Settling Time < 5 sec within 10% of bias Spectral Noise 5 micro g / Hz @ 100 Hz Mounting Thread 10-32 female Weight 0.37 oz Calibration Factors Serial # 33675 (at bottom of wash tub), X = 85.071 g/V, Y = 86.785 g/V, Z = 83.799 g/V Serial # 33363 (at top of wash tub), X = 168.45 g/V, Y = 170.96 g/V, Z = 165.59 g/V Serial # 33664 (at the cabinet), X = 171.41 g/V, Y = 170.47 g/V, Z = 173.72 g/V</p><p>Created by Phie Theng Lee 38 Michigan Technological University Appendix EQ, Test Equipment Recommendations and Calibration</p><p>PCB Load Cell Model # 208A03, Sensitivity 10 mV/lb Measurement Range 500 lb compression or tension Output Bias Voltage 8 ~ 14 VDC Frequency Range 0.0003 ~ 36000 Hz - 5% Temperature Range -65 ~ 250 degree F Spectral Noise 38.7 micro lb / Hz @ 100 Hz Mounting thread 10-32 female Weight 0.80 oz Calibration Factor Serial # 5316 126.256 lbf/V Serial # 1909 115.422 lbf/V</p><p>Model # 208A02, Serial # 9212 Sensitivity 50 mV/lb Measurement Range 100 lb compression or tension Output Bias Voltage 8 ~ 14 VDC Frequency Range 0.001 ~ 36000 Hz - 5% Temperature Range -65 ~ 250 degree F Spectral Noise 9.6 micro lb / Hz @ 100 Hz Mounting thread 10-32 female Weight 0.80 oz Calibration Factor 27.894 lbf/V</p><p>Model # 208M164, Serial # 17199 Sensitivity Measurement Range Output Bias Voltage Frequency Range Temperature Range Spectral Noise 5 micro g / Hz @ 100 Hz Mounting thread 10-32 female Weight 0.37 oz Calibration Factor 32.295 lbf/V</p><p>PCB Pressure Sensor Model # 1505M13, Serial # 163 (at Hot Water Inlet) Sensitivity 0.008 V/psi Measurement Range 0 ~ 500 psi Test Sensor Output 1 ~ 5 V Zero Output 0.988 V Zero Output Error 0.3% FS Output @ Full Scale 5.007 V Full Scale Output 4.019 V Full Scale Output Error 0.5% FS</p><p>Created by Phie Theng Lee 39 Michigan Technological University Appendix EQ, Test Equipment Recommendations and Calibration</p><p>Calibration Factor 100 psi/V</p><p>Model # 1505M14, Serial # 164 (at Cold Water Inlet) Sensitivity 0.008 V/psi Measurement Range 0 ~ 500 psi Test Sensor Output 1 ~ 5 V Zero Output 0.994 V Zero Output Error 0.2% FS Output @ Full Scale 5.011 V Full Scale Output 4.017 V Full Scale Output Error 0.4% FS Calibration Factor 100 psi/V</p><p>Omega Fast Response T-type Thermocouples with Self-Adhesive Backing Model # SA1-T-72 Maximum Temperature 350 degree F Minimum Temperature -75 degree F Wire 30 AWG PFA Teflon coated</p><p>Omega T-type signal conditioner Model # CCT-24-0/200C, Linearized, 0.3% accuracy Outputs 0 ~ 10 V Overvoltage 75 Vdc Error 0.05 degree C @ 25 degree C ambient typical Measurement Range 0 ~ 200 degree C d) Apparatus to use with Clothes Dryer Omega Fast Response T-type Thermocouples with Self-Adhesive Backing Model # SA1-T-72 Maximum Temperature 350 degree F Minimum Temperature -75 degree F Wire 30 AWG PFA Teflon coated</p><p>Omega T-type signal conditioner Model # CCT-24-0/200C, Linearized, 0.3% accuracy Outputs 0 ~ 10 V Overvoltage 75 Vdc Error 0.05 degree C @ 25 degree C ambient typical Measurement Range 0 ~ 200 degree C</p><p>Created by Phie Theng Lee 40 Michigan Technological University Appendix EQ, Test Equipment Recommendations and Calibration e) Data Acquisition Device</p><p>Figure EQ-2, HP model 35655A (front end) capable of connecting or acquiring data up to 32 channels.</p><p>Created by Phie Theng Lee 41 Michigan Technological University</p>
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages5 Page
-
File Size-